| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹19.8 LAccepted-AOC DOOR NO 7 2 30 3 OPP APSEB SUB STATION OLD GAJUWAKA MARRIPALEM VISAKHAPATNAM 530026 | VISAKHAPATANAM | ANDHRA PRADESH | 530026 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹24.8 L+₹5.0 L (25.2%)Rejected-Finance 7 32 1 PRASANTHI NAGAR GOPALAPATNAM VISAKHAPATNAM 530 027 | VISAKHAPATANAM | ANDHRA PRADESH | 530027 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹26.7 L+₹6.9 L (34.9%)Rejected-Finance | L3 | Rejected-Finance Being not L1 |
Tender Value
₹28.9 L
EMD Value
₹57,720
Closing Date
13 Oct 2023, 6:00 pmClosed
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPAIR/REPLACEMENT OF U/S SPARES FOR AUTOMATIC FIRE DETECTION SYSTEM (AFDS) AND PERIODICAL TESTING OF AFDS INSTALLED AT VARIOUS BLDGS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2023_MES_619093_1
8894
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Naval Dockyard Visakhapatnam
As per tender documents
9 documents required · 9 mandatory
₹500
GE (I) DM Visakhapatnam
₹57,720
Yes
27 Dec 2023
15 Sept 2023
20 Oct 2023
15 Sept 2023
13 Oct 2023
29 Sept 2023
Amount
(iii) Microprocessor based Conventional type Fire Alarm / Detection Control Panel with Supply Unit, Heavy Duty Battery Charger and Allied Components (iv) Fire Hydrant Panel with Allied Components Note :- (i) The contractor shall employ minimum 02 Nos of Senior Technician / Senior Mechanic [Certificate holders from recognised ITI / NCT / VT in the Electrician / Fitter trade with 5 Years of relevant experience in the field] and 02 Nos. of Semi Skilled Helpers with 3 Years of relevant experience in the field for carrying out Comprehensive Maintenance and Repairs of Microprocessor Addressable / Microprocessor Conventional type Fire Alarm System / Fire Detection System / Internal fire fighting/ Internal fire hydrant system. The Comprehensive Maintenance and Repairs shall be carried out by under the guidance of the Service Engineer of the OEM for efficient operation of Fire Alarm / Fire Detection System Internal fire fighting/ Internal fire hydrant system.
(ii) All the manpower employed shall report to Office of AGE [E/M]/ Sub Station/ Complaint Cell for day to day maintenance and efficient functioning of Fire alarm and fire fighting systems including day to day checking of serviceability and all safety features and submission of daily progress of maintenance/ repairs/ checking and updating the details in the Registers. (iii) Contractor shall provide all Spare Parts / Accessories etc. and the rate quoted is deemed to be inclusive of supply and fixing of all Major and Minor Spares viz. Mechanical / Electrical / Electronic / LED lights etc. including Cables, SCR / IGBTs / High Pressure Braided Hoses of compatible make as specified by the OEM except Spares catered vide Serial Item No. 2 to 19 of BoQ as and when required for trouble free and smooth / efficient operation of Fire Alarm / Fire Detection System complete all as directed by the Engineer-in-Charge. All the safety measures shall be ensured for serviceable condition round the clock and cost of their spares, batteries etc. shall be deemed to be included in the rate quoted. Nothing extra shall be paid extra on these accounts.
(iv) Spares catered vide Serial Item No. 2 to 31 of BoQ shall be measured and paid separately as "Supply Only" wherever required and rate quoted for Serial Item No. 1 of BoQ shall be excluding the same. However, replacing, fixing, repairs and testing shall be deemed to be included in the rate quoted. (v) The contractor shall be solely responsible for efficient functioning of all the Panels / Systems during the entire contract period. Contractor shall provide necessary Testfire /Solo test kits for testing Multisensors /Testing Kit, Tools and Equipments at his own expense.
Supply Only Microprocessor based Addressable Networking type Fire Alarm Control Panel of one loop with supply unit Heavy Duty Battery Charger and also with complete set up of LCD Display, Mother Board, Cables, Battery, Charger all the spares etc., tested and proved functionally and testing and commissioning complete all as specified and as directed. Make: Notifier / Honeywell / Cooper Note: Appropriate existing make shall be provided to avoid any malfunctioning of the entire system. However Approval for different makes shall be submitted for approval of Engg-in-Charge prior to replacement.
Supply Only Microprocessor based Wireless Networking type Fire Alarm Control Panel of one loop with supply unit Heavy Duty Battery Charger and also with complete set up of LCD Display, Mother Board, Cables, Battery, Charger all the spares etc., tested and proved functionally and testing and commissioning complete all as specified and as directed. Make:PTS / Equ Note: Appropriate exisiting make shall be provided to avoid any malfunctioning of the entire system. However Approval for different makes shall be submitted for approval of Engg-in-Charge prior to replacement.
Supply Only Microprocessor based Conventional type Fire Alarm Control Panel of one loop with supply unit Heavy Duty Battery Charger and also with complete set up of LCD Display, Mother Board, Cables, Battery, Charger all the spares etc., tested and proved functionally and testing and commissioning complete all as specified and as directed. Make: Spencer Fire / Ravel/ Vertex Note: Appropriate exisiting make shall be provided to avoid any malfunctioning of the entire system. However Approval for different makes shall be submitted for approval of Engg-in-Charge prior to replacement.
Supply only Batteries [12V, 07/12AH ] with terminals and connections complete all as specified and as directed.
Supply only Detectors complying with and type certified to EN – 45, Analog/ Addressable type, Multi-Sensor Detector with Heat and Smoke combination and installation, testing and commissioning complete all as specified and as directed. Make: Apollo/ System Sensor/ Cooper
Supply only Wireless Detectors complying with and type certified to EN – 45, Analog/ Addressable type, Multi-Sensor Detector with Heat and Smoke combination and installation, testing and commissioning complete all as specified and as directed. Make: PTS / Equ
Supply only Manual Call Point Resettable type complete all as specified and as directed. Make: Spencer Fire / Notifier / Honeywell / Cooper
Supply only Wireless Manual Call Point Resettable type complete all as specified and as directed. Make: PTS /Equ
Supply only Addressable Electronic Hooters [Buzzers / Alarm Sounders] including suitable protection box complete all as specified and as directed. Make: Spencer Fire /Ravel/ Vertex/ Cooper
Supply only PVC insulated and sheathed Multistranded, Copper Conductor, industrial cable, 1100 Volt, conforming to IS 694 of size 2 X 1.5 Sq.mm with clamps for fixing on cable tray, fixed to walls, laid in trenches / on ground with all accessories as required complete all as specified and as directed.
Supply only DOL Starter, 415 Volts, AC, 50 Hz, suitable for Motors of Capacity upto 10 HP, in Sheet Steel Enclosure and connecting up complete all as specified and as directed.
Supply only Sluice Valve, Cast Iron body, Stainless Steel Spindle, Gun Metal Rings including Wheel for operation, Flanged and Drilled, 100 mm Dia, conforming to IS – 14846, Class PN –1.6, Long Body type including Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
Supply only Butterfly Valve, 80mm Bore, Class PN-1.6, Flanged and Drilled, Conforming to IS - 13095, Cast Iron Body, SGI [Nylon Coating] Disc, SS AISI 304 Disc Seal, CS Clamping Ring, SS AISI 410 Shaft with Hand Lever operated for manual operation including Rubber Gasket and Jointing Materials, Bolts, Nuts, Washer complete all as specified and as directed.
Supply only Hose Reel not less than 20 mm bore and 30 m long as per IS – 884 complete with Gun Metal Nozzle including complete all as specified and as directed.
Supply only 63mm dia 15 metre long CP (Controlled Percolating) Fire Hose conforming to IS – 8423 complete with Male and Female Coupling conforming to IS – 903 including all Joints and Jointing Materials complete all as specified and as directed.
Supply only bulb type Gum Metal sprinkler head pendant type set to operate at 68 degree celcius conforming to IS – 15105 including all Joints and Jointing Materials complete all as specified and as directed.
Supply only Sprinkler glass bulb type (Standard response ) set to operate at 68 degree celcius temparature rating side wall type conforming to IS – 15106 / TAC complete all as specified and as directed.
Supply only Fire Alarm Sounders / Sirens Electronic type horizontal single stage continous normal operation for atleast 50 minutes with sound level 65 DB to 120 DB measured at 1.5 Mtr with sound output variation of + 5 DB with a range of 1000 metres complete all as specified and as directed.
S & F in repair MS ERW Pipe, 80 mm bore, Heavy Grade, conforming to IS – 1239 including all fittings as in Riser and Sprinkler or laid in floors or fixed to walls and ceilings duly painted with two coats of synthetic enemal paint over one coat of zinc chrome primer including testing complete all as specified and as directed.
S & F in repair MS ERW Pipe, 50 mm bore, Heavy Grade, conforming to IS – 1239 including all fittings as in Riser and Sprinkler or laid in floors or fixed to walls and ceilings duly painted with two coats of synthetic enemal paint over one coat of zinc chrome primer including testing complete all as specified and as directed.
S & F Double Headed Fire Hydrant Landing Valve of Type B of size 63 mm dia conforming to IS – 5290 including all Joints and Jointing Materials complete including taking down existing Fire Hydrant of any description complete all as specified and as directed.
M & L for replacement of gate valve 80mm dia complete all as specified and as directed.
M & L for replacement of gate valve 50mm dia complete all as specified and as directed.
S & F Fire Hose Box / Cabinet made of 16 gauge MS Sheet 800mm X 600mm X 250mm with Double Door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red outside and brilliant white inside fixed to wall and suitable for fixing Two Hose Reel of 15 m long complete including taking down existing Fire Hose Box of any description complete all as specified and as directed.
M & L for carrying out repairs to MS Sheet fire hose box of size 800mm X 600mm X 250mm installed at any location by replacement of broken glass with new 4mm thick plain glass of suitable size and derusting, cleaning, denting, welding as required including preparation of all surfaces and painting with two coats of synthetic enemal paint over one coat of red oxide primer complete all as specified and as directed.
M & L for Point Wiring complete with 1100 Volts, FRLS Grade, 4 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor Cable, conforming to IS - 694 drawn through and including heavy duty PVC Conduit, 20 mm dia including all accessories concealed in Walls / Roofs / Floors / Ceiling etc. or surface type / semi concealed type and Modular Type Pressed Metal Flush Box made out of 2mm thick MS Sheet of suitable size and including Modular type Base / Grid Frame & Cover Frame for housing Modular Type Switches, Sockets and Regulators etc. concealed in walls, including 1100 Volts, FRLS Grade, 1.5 Sq.mm, Single Core, PVC Insulated, Unsheathed, Multistranded Copper Conductor cable as earth continuity conductor with colour coding and connecting to Earth Dolly for16 amps Power Point controlled by 16 Amps One Switch including taking down existing unserviceable point wiring of any description complete all as specified.
S & F in repair Socket Outlet, 3 pin, 16 Amps and 1 pin, 5 Amps, Modular Type, Two Modules, Multipurpose, 230 Volts complete all as specified and as directed.
S & F in repair Switch Modular type, one module, Single pole, one way, 16 Amps, 230 Volts complete all as specified and as directed.
M & L for Rewinding of fire booster pump Motor of capacity 7.5 to 10 HP Capacity using super enamelled copper conductor of suitable gauge including insulation, varnishing, packing and testing etc., cleaning, greasing etc. and testing including replacement of nuts and bolts for foundation etc. complete all as specified and as directed.
S & F in repair Heavy duty PVC Conduit, 20 mm dia concealed in Walls / Roofs / Floors / Ceiling etc. inclusive of boxes [Junction / Terminal but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
MVV Prasad
SHIKHARA PROJECTS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .