Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.6 LAccepted-AOC | L1 | Accepted-AOC ACCEPTED |
Tender Value
₹5.7 L
EMD Value
₹14,130
Closing Date
9 Aug 2024, 4:00 pmClosed
ASSISTANT EXECUTIVE ENGINEER
O/o AEE PWD ELECTRICAL SUB DIVISION KOLLAM
GENERAL GMC KLM 2021 22 Budget work Construction of disabled elderly friendly environment in Govt Medical College Kollam Providing AC unit Electrical AC Work
2024_PWD_677343_3
PWD/BLDG/EST/12663/2023
Open Tender
Electrical Works
Item Rate
150 days
Parippally
Please refer tender document
9 documents required · 9 mandatory
₹1,250
₹14,130
2 Nov 2024
1 Aug 2024
12 Aug 2024
1 Aug 2024
9 Aug 2024
1 Aug 2024
Amount
SITC of AC
OD33768/2024-2025:Supply, Installation,Testing and Commissioning of minimum 2 TR Split air conditioning unit minimum capacity Invertor Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 5 star rated as per BEE and with necessary supports vibration isolators for ODU as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports, necessary power/control cabling, suitably supported on trays/ split clamps etc., PVC condensate drain pipe (upto 5 m) 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, , first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete in all respects as per technical specification(Make:Bluestar/Daikin/Carrier/Voltas/Thoshiba/Mitsubishi/Hittachi/LG)
OD33870/2024-2025:Supply, Installation, Testing and Commissioning of minimum 1.5 TR Split air conditioning unit minimum capacity Invertor Hi wall Split air conditioning unit (Indoor and Outdoor Unit) complete with suitable capacity drive motor, air cooled condenser with all accessories, hermetically sealed scroll/rotary compressor, outdoor unit and hi wall units for single phase 230 V supply minimum 5 star rated as per BEE and with necessary supports vibration isolators for ODU as required as per manufacturers recommendation, suitably sized copper refrigerant piping as per relevant ASHRAE Standards (both suction and liquid piping) including 19 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth as per specification interconnecting indoor & outdoor units with required pipe fittings and accessories like bends, tees, reducers, supports, necessary power/control cabling, suitably supported on trays/ split clamps etc., PVC condensate drain pipe (up to 5 m) 6kg/sq.cm of suitable dia connecting the drain pan of the indoor units to nearest drain point with U-trap, insulated with 9 mm thick closed cell nitrile rubber insulation finished with 7 mils factory laminated treated fibre glass cloth, required pipe fittings and accessories like bends, tees, reducers, supports, clamps, , first charge refrigerant gas R32/R410A/R407C, cordless remote etc complete in all respects as per technical specification(Make:Bluestar/Daikin/Carrier/Voltas/Thoshiba/Mitsubishi/Hittachi/LG)
OD33770/2024-2025:Supply of 5 KVA automatic voltage stabilizer for A/C unit with input voltage 170 - 270 V and output 210 -230 V with overload protection (cut off), time delay, indicator, chord wire etc., as required.
OD33771/2024-2025:Supply of 4 KVA automatic voltage stabilizer for A/C unit with input voltage 170 - 270 V and output 210 -230 V with overload protection (cut off), time delay, indicator, chord wire etc., as required.
OD33871/2024-2025:Supply and installation of out door unit stand for single/three phase wall mounting split AC unit including nut bolt wall plug etc as required
OD37360/2024-2025:Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberised foam sleeve 10mm thick, brazing, leak testing etc. 9mm (3/8"), 16 mm (5/8") dia. 22 gauge
OD37472/2024-2025:Supply and providing following size soft drawn Copper pipe for extending pipe between out door and indoor units including insulating pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc. 1/4"(6.35mm) and 1/2"(12.7mm) 22 gauge-
OD37296/2024-2025:Supply and fixing of 25mm (10kg/sq.cm) PVC drain pipe along with all required accessories in surface/ recess including cutting the wall and making good the damages etc. as required-
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.9.2.1:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.100 x 50 mm CMS with base and lid
90.9.2.3:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.External angle 90 degree
90.9.2.8:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.End cap
90.9.2.10:Supply and fixing 100 x 50 mm PVC Cable Management System with base and lid along with the following accessories conforming to IEC 61084/ BS 476 & 4678 on surface / recess including cutting the wall and making good the damages in case of recessed installation as required.Joint cover
90.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
Bidder Name
GEEKEY COOLING SOLUTIONS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1063292.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .