Tender Value
₹2.8 Cr
EMD Value
₹5.6 L
Closing Date
17 Feb 2026, 4:00 pmClosed
Executive Engineer RnB Division Ganderbal
Executive Engineer RnB Division Ganderbal
Town Hall Upgrade and Extension for General Public
2026_PWDJK_302510_1
NIT No.100-2025-26
Open Tender
Civil Works
Percentage
365 days
Ganderbal
as per NIT and SBD
2 documents required · 2 mandatory
₹5,500
Executive Engineer RnB Division Ganderbal
₹5.6 L
Superintending Engineer RnB Circle Ganderbal
28 Feb 2026
7 Feb 2026
18 Feb 2026
7 Feb 2026
17 Feb 2026
7 Feb 2026
12 Feb 2026
Construction of Town Hall at Ganderbal
Earth work in bulk excavation by mechanical means (hydraulic excavator) over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 m2 on plan) including disposal of excavated earth lead upto 50 meters and lift upto 1.5 m, as directed by Engineer-in-Charge. All kinds of soil :
P/L, of dry stone soling in the excavated trenches duly hand packed for foundation and backfilling with ramming, dressing, and compacting all inclusive leads, lifts, loading, un-loading, cost and carriage of material involved complete finished work to be measured.
Supply & filling of nallah muck in plinth free from organic and deleterious material including ramming, compacting, all inclusive leads, lifts, loading, un-loading, cost and carriage of materials from approved nearest source to site of work complete.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) complete.
Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) incl. carriage complete.
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) all complete.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete.
Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with: 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) complete.
Centering and shuttering including strutting, propping etc. and removal of form work for: Foundations, footings, bases of columns etc. for mass concrete etc complete.
Centering and shuttering including strutting, propping etc. and removal of form work for: Suspended floors, roofs, landings, balconies and access platforms. etc complete.
Centering and shuttering including strutting, propping etc. and removal of form work for: Lintel, beams, plinth beams, girders, bressumers and cantilevers complete.
Centering and shuttering including strutting, propping etc. and removal of form work for: Columns, pillars, piers, abutments, posts and struts. complete.
Centering and shuttering including strutting, propping etc. and removal of form work for: Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc upto plinth level.
Centering and shuttering including strutting, propping etc. and removal of form work for: Stairs (excluding landings) except spiral staircases.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Dry random rubble masonry with hard stone in foundation and plinth: Without bond stone (Nallah) incl. all carriage/head load involved all complete.
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded
Reinforcement for RCC work including straightening ,cutting ,bending, placing in position and binding all complete (Thermo Mechanically treated bars) etc complete.
Providing/Fixing of CGI Colour coated (Hi-Rib) profile sheets for roofing including vertical/curved surface fixed with Polymer coated J or l hooks, bolts and nuts 8mm diameter with bitumen and G.I Limpet washers or with G.I Limpet washers filled with white lead, including overlapping of sheets complete (upto any pitch in horizantal/ vertical or curved surface) excluding the cost of purlins, rafters (0.50mm thick) etc incl ridges hips/ valleys 60cm vide of colour GI sheets sheets including cost of screws/ washers all complete and cost and carraiges of materials complete.
Providing and fixing of 10mm thick wooden knotted imported panelling fixed in soffits incl. underneath frame work of wooden jambs of size 50x25mm incl. wooden cornice of required size. The job shall also incl. scaffolding, finishing with coat of touch wood polishing etc all upto the satisfication of EIC complete.
Providing and fixing of plained eves boarding of 2nd class kail wood 250x32mm size all complete.
Carriage of material:- Stone Agg. For an avg. lead of 10 Kms
Sand for an avg. lead of 10 Kms
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in :Cement mortar 1:4 ( 1 cement : 4 coarse sand) all complete.
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Providing and laying chisel dressed Devri Stone of size 300x200 mm face with 150 mm depth in cement mortar 1: 6 (1 cement : 6 coarse sand) upto plinth level including curing. One face dressed Rough chisel dressed all complete.
Kota stone slab flooring 25 mm thick over 20mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing, polishing and curing complete with base of cement mortar 1:4 (1 cement : 4 coarse sand) all complete.
Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622 of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1cement :4 coarse sand) including grouting the joints with white cement and matching pigments etc. complete Size of tile 600x600 mm all complete.
Providing and fixing Ist quality ceramic glazed wall tiles of approved make, in all colours, shades(of 7-8 mm thick of different sizes) as approved by Engineer- in-Charge, in walls, skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 ( 1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg per sqm, including pointing in white cement mixed with pigment of matching shade incl. all carriages etc complete.
Providing and fixing of 8mm thick laminated wooden Flooring incl. 2mm thick foam including cost of nails/bolts and beadings as required all necessary fittings/fixtures all carriages etc complete as per directions of EIC.
Providing and fixing factory made uPVC white colour casement/ casement cum fixed glazed windows comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, stainless steel (SS 304 grade) friction hinges, zinc alloy (white powder coated) casement handles, G.I fasteners 100 x 8 mm size for fixing frame to finished wall, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealant shall be paid separately) Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement cum fixed panel window having both end single casement panel, middle fixed panels and at top completely fixed ventilator with S.S friction hinges (350 x 19 x 1.9) made of (big series) frame 67 x 60 mm , sash 67 x 80 mm &mullion 67 x 80 mm all having wall thickness of 2.3 ± 0.2 mm and single glazing bead/double glazing bead of appropriate dimension. (Area of window above 3.00 sqmu pto 5.00 sqm).
Providing and fixing factory made uPVC white colour casement/ Casement cum fixed glazed door comprising of uPVC multi-chambered frame, sash and mullion (where ever required) extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), uPVC extruded glazing beads of appropriate dimension, EPDM gasket, zinc alloy (white powder coated) 3D hinges and one handle on each side of panels along with zinc plated mild steel multi point locking having transmission gear, cylinder with keeps and one side key, G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws, etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, mullion (if required) shall be also fusion welded including drilling of holes for fixing hardware's and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes and silicon sealent shall be paid separately). Note: For uPVC frame, sash and mullion extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable. Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made. Casement door with 3D hinges made of (big series) frame 67 x 64 mm & sash 67 x 110 mm both having wall thickness of 2.3 ± 0.2 mm and single glazing bead / double glazing bead of appropriate dimension. (Area of door upto 2.00 sqm).
Supplying, fitting, and fixing ornamental/heritage/traditional features in second-class deodar wood, including Dajji Diwari (Dhajji Dewari style infill panels or similar ornamental work), crowns, bracings, beams, and columns, complete as per manufacturer's specifications or directions of the engineer-in-charge. Wood shall be well-seasoned, second-class deodar, dressed/planed as required, with necessary joinery, fixings, and finishing.
Finishing walls with 100% Premium acrylic emulsion paint havingVOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives. New work (Two or more coats applied @ 1.43 litre/10 sqm. Over & including priming coat of exterior primer applied @ 0.90 litre/10 sqm.
15mm Cement plaster on the rough side of single or half brick wall of mix: 1 : 4 ( 1 cement : 4 fine sand) all complete.
Providing and applying one coat of dust-resistant acrylic wall putty of approved make and amnufacture specially formulated for easy sanding and minimal dust genration on drying on new or prepared masonry/plaster substrates (Walls/ceiling) incl. filling cracks up to 2mm surface leveling, curing and sanding ready for subsequent finish coat all complete.
Providing & laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen & the like consisting of: (i) Ist course of applying cement slurry @ 4.4 kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. (ii) IInd course of 20 mm cement plaster 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. (iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 kg. Per sqm of area. (iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 kg/sqm).
Providing and laying flamed finish Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge : Flamed finish granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer M.S. tube all complete.
Ruled/flush pointing on white sand stone masonry surface with lime, surkhi and marble dust mortar in the ratio 1:1.5:1/2 one lime : 1.5 surkhi ( 50% red and 50% light yellow surkhi):1/2 marble dust ( the rate is inclusive of all materials and labours involved except scaffolding) all complete.
Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. NOTE:- To be used for maintenance work judicially necessary deduction for scaffolding in the existing item to be done
French spirit polishing, Two or more coats on new works including a coat of wood filler all complete.
Carriage of material:- Bricks For an avg. lead of 40 Kms
Sand for an avg. lead of 10 Kms
Providing and fixing 3 layer PP-R (Poly propylene Random copolymer) pipes conforming to IS: 15801, UV stabilized and anti-microbial fusion welded, having thermal stability for hot and cold water supply including all PP-R plain and brass threaded Polypropylene random fittings. This includes testing of joints complete as per direction of Engineer-in charge Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc PN-16 pipe , 25mm OD(SDR-7.4).
(External work incl. Trenching, reffling etc) PN-16 pipe , 25mm OD (SDR-7.4)
PN-16 pipe , 32mm OD (SDR-7.4)
PN-16 pipe, 40mm OD (SDR-7.4)
Providing and fixing PPR Unions PPR Union 20mm
PPR Union 25mm
PPR Union 32mm
PPR Union 40mm
Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) 50 mm dia. nominal bore
Laying and fitting of G.I. pipes (all classes) complete excluding cost of pipes, fittings and Earth work. 40 mm and 50 mm dia. G.I. pipes
Providing and fixing ball valve (brass heavy duty) of approved quality, High or low pressure, with plastic floats complete 25 mm nominal bore
32 mm nominal bore
40 mm nominal bore
50 mm nominal bore
Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank
Providing and fixing of PVC fittings for PVC pipes of approved quality and make( prince B type) with all fittings such as bends, tees, elbow, offset, clamps etc incl. cutting the floors, walls and making good the same in cement concrete 1:2:4 and cement mortar 1:4. the jointing to be completed with rubber ring joint/solvent weld joint as required 50mm dia nominal bore.
110mm dia Nominal bore
150mm dia Nominal bore
PVC Floor Trap 110mm
Constructing brick masonry road gully chamber of specified size with common burnt clay(non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4coarse sand) including precast R.C.C. horizontal grating with frame complete as per standard design: Chamber size 50x45x60 cm including precast R.C.C grating with frame 500x450 mm horizontal grating all complete.
Providing, fixing, Testing and commissioning of white viterous china wall mounted European water closet incl. and fixing CP bolts, nuts, fisher/ anchor bolts are required for hanging of WC, nuts, supporting arrangements, bakelite/poly propylene seat and cover with CP hinges and rubber buffers, WC pan connector (Straight/offset type macfit single body push fit type WC pan connector with factory supplied spring loaded seal guard of Mc alpine, UK with integral single mould sealing fins made of flexible EVa body, incl. bush/adaptor complete with all accessories incl. cutting and making good the wals and floors wherever required of approved brand al complete.
Providing, fixing, Testing and commissioning of concealed type cistern comprising of actuator button facia assembly including kombifix-designer line tool free series (Chair bracket, drainage pipe and wall mounting framing) brass/SS screws and washer complete, cutting and making good the walls floors whereever required of approved brand all complete.
Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer
Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings.
P/F of 32mm CP brass waste of approved brand and make complete.
P/F of 40mm CP brass waste of approved brand and make complete.
P/F of PVC waste pipe for sink or wash basin incl. all necessary fittings/fixtures all complete. 32mm dia flexible pipe
40mm dia flexible pipe
Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
Providing and fixing uplasticized PVC connection pipe with brass unions 15 mm nominal bore
P/F of CP brass Sink/Wall mixer of pproved brand and manufacture (Cera, Jaguar or equivalent brand) incl. all necessary fittings complete.
CP Brass 2 in 1 Bib Cock of pproved brand and manufacture (Cera, Jaguar or equivalent brand) incl. all necessary fittings complete.
Health Faucet with Hook and flexible tube 1 Mtr.
Angle Valve
Towel Rail 600mm long
Soap Case
Towel Ring
Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 610x460mm bowl depth 200mm
Electrification
Wiring for Light point/Exhaust point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Anchor/Salzer/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Supplying and Fixing of Indicator as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Wiring for Fan point with (P+N+E) 3x1.5 sq.mm FRLS-H/HFFR PVC insulated Multi strand Copper conductor single core cable (Polycab/Finolex/Salzer/Anchor/Havells Make) in existing surface/recessed Conduits (Including Cost of Conduit) laid in slabs with 01 No.of 6 Amp Modular Switch,Modular Plate,Cover in front & suitable GI box etc ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required,ISO/IEC Certified of Legrand(Myris)/ Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Wiring for Power Plug with (P+N+E) 3 x 4 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Anchor/Salzer/Havells Make)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required, ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.(Including Inverter Input/Output)
Wiring for 6Amp Plug(Computer Point) with (P+N+E) 3 x 2.5 sq.mm FRLS-H/HFFR PVC Insulated Multi strand Copper Conductor single core cable in surface/Recessed Conduit (Polycab/Finolex/Salzer/Paraflex Make)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including proving and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings), ISO/IEC Certified Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/Schneider(Zencelo)/Equivalent Make & shall be approved before execution of work.
Wiring for Sub main Wiring along with earth Wire with the following Sizes of FRLS-H/HFFR PVC insulated copper conductor, single core Cable in surface/Recessed medium class PVC conduit (Polycab/Anchor/Finolex/Salzer/Havells Make) & shall be approved before execution of work.
2x10 sq.mm+ 1x6 sq.mm (P+N+E) for Power point Sub main in One run from Main Panel to Distribution Boards.
2x6 sq.mm+ 1x6 sq.mm (P+N+E) for Lighting/Inverter/AC Point Sub main in One run from Main Panel to Distribution Boards.
2x2.5 sq.mm+ 1x2.5 sq.mm (P+N+E) for Lighting/Inverter Circuit in One run from switch boards to Distribution Boards.
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required of Havells(Crab-Tree)/ Legrand(Myris)/Anchor Rooma Plus/ Schneider(Zencelo)/Equivalent Make
Supply/Fixing/Testing and Commissioning of 6Amp to 32Amp Rating SP,240v,*C* Curve 10K, Miniature Circuit Breaker suitable for inductive load of following poles in existing MCB . DB Complete with connections.(L&T/Siemens/Legrand/ABB /Schneider/BCH Make)
Supply/Fixing/Testing and Commissioning of Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (L&T/Siemens /Legrand/ABB/Schneider/BCH Make)
Supplying and Fixing of MCB 6-Way (4+18) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make)
Supplying and Fixing of MCB 8-Way (4+24) horizontal typed , sheet steel, Double Door Distribution Board, TPN 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc, as required. (L&T/Siemens/Legrand/ ABB /Schneider/BCH Make)
ENVIRONMENTALLY SAFE MAINTENANCE FREE COPPER ROD EARTHING SYSTEM Necessary soil treatment is to be made by the contractor in order to improve the Pit resistance Value.Supply,Installation and Testing of 75 mm copper Pipe Filled with Crystalline conductive Mixture with Eco friendly GEM Backfill Compound 2No. Bags also having Earth pit chamber (300mm x 300mm) with man- hole cover for the above. Including cost of 20mm Wide copper strip as required in one run fitted with of brass nut bolt & spring washer from EARTHING ROD up to MAIN Control PANEL through suitable DWC High Density Poly ethylene Pipe having Corrugation complete job.
Supply and fixing of 18 Watt LED Powder coated die cast/Extruded aluminum Body including trim with Aluminum Reflector(System lumen efficacy ≥ 105 < 120 lm/Watt ) Recess/surface mounted (Commercial type) downlighter having following specficafications .The luminaire should have a colour temperature of 6500°K, CRI≥80 and SDCM≤5. Luminaire shall be designed to emit initial system lumen output of greater than 2520 lumens with minimum system efficacy of 140 lumen/watt .The downlighter shall be back-lit & not side-lit. The driver shall have THD≤10% (@full Load) and PF ≥ 0.95 (@full load). The luminaire housing /body should made of pressure die-cast aluminum. The fixture should comply with the parameters as per IS10322. The luminaire shall have impact resistance of IK02 & ingress protection of IP20. Luminaire manufacturer must have In-house NABL accredited lab to conduct LM79, Type test as per IS10322, "FAT" before dispatch as per IS 10322 & IK Test. The luminary shall have average life of 50000 hrs operating temperature -10 C to + 45 C The successful bidder must submit the NABL accreditation certificate for Luminaire manufacturer before supply of material. The LED Luminaire should be BIS registered. Successful bidder shall submit the following reports before supply of material for approvals: LM79 issued by NABL accredited lab, LM80 issued by LED manufacturer, Type Test Certificate for luminaire as issued by NABL accredited lab & BIS certificate for LED Luminaire & Driver. The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason. Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Endo/Regent /Trilux /Wipro make.
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft of 22 Watt (System lumen efficacy ≥120 <135 lm/Watt) of Powder coated Extruded aluminium/CRCA Body and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Endo/Regent /Trilux /Wipro make. (For Inverter Only)
Supplying, installation, Testing & Commissioning of Panel light 2x2 ft of 34-36 Watt(System lumen efficacy ≥120 <135 lm/Watt) of Powder coated Extruded aluminium/CRCA Body and construction as per IS : 10322 with driver as per the requirement with Driver efficiency >85%, Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection, THD < 10% , P. F.≥0.95, IP20, CRI >80, UGR (Unified Glare Rating) < 19, Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitry), of minimum 50000 Burning Hours with, 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K / 6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.) Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS,PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 3 year OEM warranty. System lumen efficacy ≥105<120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C).The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Endo/Regent /Trilux /Wipro make.
Supplying, installation, Testing & Commissioning of 100 Watt (System lumen efficacy ≥120 and <135 lm/Watt) Flood Light, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50 deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4-5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP-66,IK-10, CRI >80 , under voltage and over voltage protection, EMIEMC as per CISPR -15 , lenses for beam angle 30 deg-120deg as per the application and the project requirement deg., suitable tilt able fitting, life time (LED,Driver & electrical circuitary) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till life ends as per LM80 extrapolation IES TM-21-11 report, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy 105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). The Agency / firm must submit the Technical data sheet (TDS) on OEM letter head along with requisite certificates for approval by an officer from the department not below the rank of SDO ,prior to the supply of materials. The Job includes 2-years replacement warrenty from OEM for the entire lighting fixtures from the the date of sucessful handing over of site to intending department , covering any damage /mulfunctioning /burnt out what so ever reason. Approved Make: Signify (Philips)/Crompton/Lighting Techonology/Surya/Wipro make.
Supply/Installation/Testing and Commissioning of BLDC 1200 mm sweep, ceiling fan with 03 No. blades, 30 cm long down rod, 02 No. canopies, shackle kit, Power Factor not less than 0.9, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase Supply, etc. complete as required. USHA/Halonix/Polycab/Orient Make.(5-Star)
Supply/Installation/Testing and Commissioning of upto 400mm Shutter Typed,320 Cu.m/Hr.AC 220-240 Volts, 50 Hz Exhaust fan made out of ABS Plastic Material with inbuilt thermo cut-off Protection and Noise Level not exceeding 37dB o including connection etc USHA/Anchor/Polycab/Orient/Halonix Make.
Supply/Installation/Testing and Commissioning of ABC type Fire Extinguisher 4.Kg. Capacity ISI Mark(IS:15683) and dully certified.
Supply/Installation/Testing and Commissioning of CO2 Type Fire Extinguisher 4.5 Kg. Capacity ISI Mark(IS:15683)suitable for 'B' and 'C' class fires - inflammable liquids, gaseous fires like L.P.G,acetylene and electrical fires.
Supply and Fixing of single pole blanking plates on existing MCB boxes, excluding cost of Boxes.
Providing and fixing of bakelite hylam sheets of required size including cutting, filing with S/F screws etc.
Supply and Fixing of Modular 25-32Amp industrial Socket outlet having fitted with 32 Amps DP MCB and Top with Modular Plate,Cover in front & suitable GI box etc for AC Points of Legrand/Anchor/Seimens/L&T/ Equivalent Make.
Supply/Installation/Testing and Commissioning of 9-15 Watt. LED Mirror Light fitting with Aluminium Body of Philips/Bajaj/ Wipro/Jaguar/Panasonic/Havells/Equivalent Make including making of necessary connections including cost of Ceiling Rose,Silken wire also with round plates Etc complete.
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required of Legrand/Panasonic/Anchor/Schneider/Equivalent Make
Supply/Installation/Testing/Commissioning of 3.5-4KVA/48 V Pure Sinewave Solar Inverter With ISOT Technology, Intelligent Load Sharing & BIS Certified (with 2-Year Warranty), 04 No. of 200Ah,12V Tubular battery (with 36 Months Warranty) & Suitable Trolley Support for Inverter resting & resting of Tubular Battery etc Luminious/EXIDE/AMRON Make.(For Each Floor)
Supply/installation/testing and commissioning of CPRI-approved panel Wall/floor-mounted compartmentalized, 415 volts TPN MCCB Main Distribution panels, fabricated out of sheet steel of 16 gauge dust-protected, painted incl earth terminal with all necessary accessories as required for panel with internal wiring of panel. The Panel is to be provided and fitted with the following adjustable-type controlling/protection switchgear devices: 1. Normal Incoming: 250 Amp TPN MCCB with breaking capacity of 36 KA with extended thimbles of Legrand/Siemens/ABB//LK make = 1 No.,400 Amp Bus bar Al Strips(3+1) = 1 Set, MultiFunctional Meter =1 No., phase indicators =1 set 2. Generator Incomer: 100 Amp Four Pole Change over Switch of Legrand/Siemens/ABB//LK make = 1 No., 200 Amp Bus bar Al Strips(3+1) = 1 Set, Digital Voltmeter =1 No., Digital Ammeter = 1 No., CT coils for Ammeter 300 / 5A = 1 set, phase indicators =1 set 3. Bypass Switch: 100 Amp 4-Pole Bypass Switch for bypassing AVR Outgoing: (1) 63 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 10 No for normal heating sub main (2) 40 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 30 No for Sub main lighting/ACs (3) 32 Amp DP MCB (10 KA) of Legrand/Siemens/ ABB/Schinder /L&T make = 10 No for Sub main invertor The Panel manufacturing unit should be CPRI Registered and the Contractor has to submit the test certificate of main switch gear and Drawing of panel (Showing claerly dimensions of panel with spacing of switchgear as per IE Standards) is to be approved by Engineer Incharge before manufacturing.
Providing and Laying of shock proof rubber mats of 2mx1mx12mm thick in size of Standard Make.
Supply/Laying/Testing and Commissioning of 3.5- Core 120 mm sq. Al armored XLPE Insulated,PVC cable Havells/Polycab/RR Kabel/Paramount/KEI Make. Including Supply/Laying of HDPE Pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation where required and refilling the trench of standard make as approved.The cable shall include end termination lugs with its crimping /taping.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.15 MB
Tendernotice_2.pdf
PDF • 1.00 MB
BOQ_981741.xls
BOQ • 0.40 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .