Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.5 LAccepted-AOC | L1 | Accepted-AOC Over all rates are reasonable and lowest. | |
| 2 | L2₹38.1 L+₹3.4 L (9.91%)Rejected-Finance | L2 | Rejected-Finance Over all rates are higher than L-1. | |
| 3 | L3₹39.6 L+₹4.9 L (14.0%)Rejected-Finance 129 A NICHLI CHOWKI DEVI NAGAR SECTOR 32 PANCHKULA HARYANA 134109 | PANCHKULA | HARYANA | 134109 | L3 | Rejected-Finance Over all rates are higher than L-1. |
Tender Value
₹45.5 L
EMD Value
₹91,100
Closing Date
2 Oct 2024, 6:00 pmClosed
GE (West) Bareilly
GE (West) Bareilly
SPECIAL REPAIR TO SOLAR WATER HEATERS, PROVISION OF HIGH MASTLIGHT AT TANK CHOWK, PROVN OF HIGH MAST LIGHT AT CLYDE BARRACK, PROVN OF AUTO ON/OFF SYSTEM FOR 250 KVA DG SETAT JLA, PROVN OF HIGH MAST LIGHT AT FAFA UNDER AGE E/M OF GE (WEST) BAREILLY.
2024_MES_671813_1
8230/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE (West) Bareilly
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE (West) Bareilly
₹91,100
Yes
16 Nov 2024
4 Sept 2024
4 Oct 2024
4 Sept 2024
2 Oct 2024
20 Sept 2024
Amount
Repair/maint of Solar water heating system by cleaning solar plate from outside with the help of soap/shampoo /washing detergent completely by removing dust and dirt. Cleaning the solar heating tank from inside with the help of suction pump removing dirt and dust from complete unit, and proper functionng, do minor repair if required complete all as specified and directed .
Supply,installing,testing & commissioning of MNRE approved and confirming to IS :12933 P-1,2,3,4,5 Flat Plate Collector including taking down old unservicable flat plate collector complete all as specified and directed.
Supply,installing,testing & commissioning of MNRE approved and confirming to IS :12933 P-1,2,3,4,5 Solar Hot water system 500LPD with insulation including taking down old unervicable hot water tank complete all as specified and directed.
Supply,installing,testing & commissioning of MNRE approved and confirming to IS :12933 P-1,2,3,4,5 Solar Hot water system 300LPD with insulation including taking down old unservicable hot water tank complete all as specified and directed.
Supply,installing,testing & commissioning of MNRE approved and confirming to IS :12933 P-1,2,3,4,5 Solar Hot water system 200LPD with insulation including taking down old unservicable hot water tank complete all as specified and directed.
Supply and fix heating element with thermostat 2 KW complete unit including taking down old unservicable heating element complete all as specified and directed.
Supply and fix heating element with thermostat 3 KW complete unit including taking down old unservicable heating element complete all as specified and directed.
S & Fix in repair glass wool and aluminium ,insulation complete all as specified and directed.
S & Fix 25 mm hose pipe including taking down old hose pipe complete all as specified and directed.
S & Fix in repair solar kit ( gasket ,nut bolt ,flange nipple ,end pug all accessories) as required complete all as specified and directed.
S & Fix in repair Gun metal globe, gate valve 20 mm dia with iron wheel head complete all as specified and directed.
M & L in replacement Sub main wiring concealed type with two single core cable PVC insulated cable with 4.0 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of copper conductor of size 4 Sqmm connected to common earth dolly and drawing into rigid PVC conduit with lock pattern incl. making good the disturbed surface complete all as specified and directed. (Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit).
M&L in repair for mild steel OHT cage ,bands,straps ,support or stay fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot, drilling holes for bolts, in any hape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all as specified and directed.
M & L for brazing /welding in any leakage in solar water heater complete unit all as specified and directed.
Excavation in trenches not exc 1.5 mtr width and not exce 1.5 mtr in depth in soft/loose soil and getting complete all as specified and directed.
Removal of excavated material to a disance n.exc 50 mtr and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Returning , filling in including spreading levelling watering and well ramming in layers n.exc 25 thick for soft/loose soil complete all as specified and directed.
Supply and Laying XLPE insulated, screened PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor cable, laid in trench or fixed to wall / passing through pipe/ pole complete of size 35 Sqmm 3.5 Core complete all as specified and directed.
M&L for sand cushioning /sand covering for underground cable protection and consolidated and compacted with clean dry sand complete all as specified and directed.
M&L bricks with sub class 'B' locally available laid in trenches above sand cushioning for cable protection complete all as specified and directed.
S&F of High galvanized mast light 16 meter height suitable for 6 to 9 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6 mm dia 97/19 guage and double drum winch with luminaire mounting arm, pully assembly, aviation obstruction light, lightning arrester spike including RCC foundation as per height complete all as specified and directed.
Supply and fixing LED flood light 210 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and directed.
Supply & fixing PVC insulated & sheathed stranded copper cable 5 core of cross sectional area 2.5 sq mm for proving necessary electrical connection from feeder pillar box to light fittings including with suitable size copper lugs complete all as specified and directed.
M&L for of Earthing with Galvanised Earth Plate Electrode 600x600x6mm thick burried directly in Ground (Earth Pit not less than 2.25 Metre below Ground Level) with Top edge of the Plate not less than 1.50 Metre below Ground Level, connected to galvanised earth Strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc. 150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) with Cast iron cover 10mm thick hinged, Cast Iron Frame, MS Rod 6mm, Funnel, GI Pipe 20mm medium grade all as shown in Electrical Plate No. 3 of MES Schedule Part-I including necessary Excavation in Soft/Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and and Testing on Completion, complete all as per specified and as directed.
M&L for Galvanised Steel Tubing Pipe 40 mm bore (dia), light grade with Bend, laid in Trenches or under Roads crossing/Flooring/Culverts/Footpath complete all as specified and as directed.
Supply, install, commissioning and testing cubical type outdoor type LT Panel box, made out of 3.15 mm thick mild steel sheet, of size not less than 600 mm x 500 mm x 300 mm with mild steel angle iron frame and legs (of length 400 mm) of section 40 mm x 40 mm x 6 mm thick, with front openable door (with locking arrangement) duly powder coat painted over a coat of red oxide primer, with provision of cable entry and exit at mid portion of the feeder pillar box (with cable gland), and providing one number Danger Notice Plate (of size 15 cm x 10 cm, suitable for LT line, made out of 0.6 mm thick mild steel sheet, vitreous enameled white, with letters, figures and conventional skull and bones in signal red colour, fixed with clamps and nuts-bolts of suitable size) and providing necessary foundation of the feeder pillar box in PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) complete all as directed by the Engr-in-Charge comprising of the following accessories :- (Contd.....)
S& fix for installation of retrofit machine devices on dg set to control Emission from DG Set 250 kva to control emission from DG set as per guide line including,necessary addition alteration in existing DG set,necesary jointing accessory like Nut ,bolt,washer /welding /breezing work etc for the following DG set as per directed to complete all as specified and directed.The device shall be single phase, including automated panel equipped with digital type indications such as automatic,temperature monitering sensor ,pressure monitoring sensor ,differential pressure monitoring sensor ,visible alarm system with suitable sensor ,equipped with cloud based online data availability to the end user of effectively monitor the efficiency of the device remotely. (Contd.....)
M&L for PCC work 1:2:4 as required at site for Foundation as specified by OEM and welding work incl loading unloading are included in quoted rate complete all as specified and directed.
S& F LT XLPE insulated ,armoured heavy duty electric cable with aluminium conductor ,1100 Volts grade ,cross sectional area 120 Sqmm 3.5 Core complete all as specified and directed.
Notes:- Tenderers may note that amount as given in schedule of credit will be deducted from the total amount to worked out the net contract sum at the time of Acceptance of tender.
LEEJA ENTERPRISES (BID ID -3113109)
SONI ENTERPRISES (BID ID -3125246)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .