| 1 | L1₹9.2 LAccepted-AOC 894 NEAR 132 KV POWER HOUSE SINDHARI ROAD BALDEV NAGAR BARMER RAJ 344001 | BARMER | RAJASTHAN | 344001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.3 L+₹85,925 (9.06%)Rejected-Finance HOUSE NO 01 B JANANA DODI OPP AKSHAY HOTEL RAI KA BAGH JODHPUR RAJASTHAN 342010 | 342010 | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | L3₹10.9 L+₹1.4 L (15.0%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L3 | Rejected-Finance NOT LOWEST BIDDER | |
| 4 | L4₹11.4 L+₹1.9 L (20.1%)Rejected-Finance | L4 | Rejected-Finance NOT LOWEST BIDDER | |
| 5 | L5₹14.0 L+₹4.5 L (47.2%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST BIDDER |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
4 Oct 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Garrison Engineer Banar
Garrison Engineer Banar, Jodhpur-342027
REPAIR AND MAINT OF STREET AND GARDEN LIGHTS AND ITS CONNECTED ITEMS AT RALAWAS UNDER GE BANAR
2024_MES_672394_1
8824/35/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Banar
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Garrison Engineer Banar
₹30,000
Yes
23 Dec 2024
6 Sept 2024
11 Oct 2024
6 Sept 2024
4 Oct 2024
20 Sept 2024
Amount
M&L for checking/testing of street lights fittings any type, to detect the fault and repair on pole (if minor fault like remove carbon,lose connection etc) complete all as specified.
Strip opening and taking down carefully defective/non functional street light fittings of LED's from its existing position any capacity & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from junction box to driver/ control MCB not working in junction box) of the fitting if the fitting can not be repaired/functionable, the old U/s fitting to be deposite to MES store for reapair and re-assembling and testing complete all as specified. Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately. (b) Contractor provide Extendable wheel laddar or hydra also in above job
S&F LED street light fitting 90 watt 230V AC outdoor type with high pressure die cast aluminumhosing and heat resistant complete with driver,lamp bracket with impact and corrosion resistan including thermal management in multiple optics complete with IP-65/66 protection ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and all acessories complete all as specified.
All item as per Ser No 3.00 above but 60 watt.
Striping out and taking down carefully defective/non functional gate/garden light/post top lantern fittings of LED's from its existing position any capacity & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from control panel to driver) of the fitting if the fitting can not be repaired/functionable, the old fitting to be replaced by new fitting as per given in this sch complete all as specified. Note :- (a)other items i.e flexible cable, MCB to be measured and paid separately.
S&F Post top lantern LED type 20 watts 230V AC outdoor type with decorative post top for 360 degree indirect light IP-65 protection with impact and corrosion resistant complete with driver and lamp complete ll accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size and aii acessories complete all as specified.
Striping out and taking down carefully defective/non functional flood light/bldg security light for > 10m high bldgs of LED's from its existing position and capacity & refixing the same after checking of serviceability (the power supply can not be meet to driver/ flexible cable burnt from control panel/distribution box to driver/ control MCB not working in distribution box) of the fitting if the fitting can not be repaired/functionable, the old fitting to be replaced by new fitting and re-assembling and testing complete all as specified. Note :- (a) Any other items i.e MCB, flexible cable to be measured and paid separately.
Supply and fix MCB SP 6-32 Amps 230V 10KA 'C' curve and taking down existing unserviceable from its own position and taken as schedule of credit all as specified and directed by Engr-in-Charge.
Supply and fix in replacement of PVC insulated unsheathed flexible copper conductor flexible cable three core multi stranded 1.5 Sqmm and taking down existing from its own position and taken as credit all as specified and directed by Engr-in-Charge.
Taking down old and Supply and fix thermoplastic cable junction box IP 65 with plain walls of size 210x310x116mm and making suitable size hole for cable entry complete with cable terminals/connectors and other fittings fixed on poles with MS flat iron nut bolts, washers and double compressor metal glands of suitable sizes etc and disconnecting of existing junction box and taken as credit complete all as specified.
M&L painting of LT pole any type of size externaly above foundation and junction box including all MS work with one coat of aluminium paint after scraping /cleaning well the existing surface complete all as specified. Note :- The item included in the painting 3 Nos 30 cm wide bands black & Yellow synthetic enamel paint in alternate layer upto 1.0 mtr high above foundation and writing the pole No in 5 cm wide on base of yellow colour with LT complete all as specified.
Dismentling of old LT Cable and Supply and laying in trenches/on pole XLPE/PVC Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor cable of following sizes taking out from trench and again laid in trenches/duct/ pipes/ wall and open surfaces complete all as specified. Note :-(1) During the laying of cable minor accessories i.e lugs, nut-bolts and steel glands deemed to be fit inclusive in quoted rate. (a) 16 Sqmm 4 core
All items as per Ser No 12.00 above but 10 Sqmm 4 core
Rerouting cable of size 10/16 Sqmm 4 core in trenches/on pole XLPE/PVC Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor cable of following sizes taking out from trench and again laid in trenches/duct/ pipes/ wall and open surfacescomplete all as specified. Note :-(1) During the laying of cable minor accessories i.e lugs, nut-bolts and steel glands deemed to be fit inclusive in quoted rate.
Supply,fixing and testing in repair/replacement of LED 45/60W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire as specified as per directed by EIC
Supply,fixing and testing in repair/replacement of LED 75W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire complete all as specified.
Supply,fixing and testing in repair/replacement of LED 100W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire complete all as specified.
Supply,fixing and testing in repair/replacement of LED 150W driver with surge protection complete connection to LED Flood/street/highbay light fitting with suitable wire complete all as specified.
Supply and fixing in repair/replacement of LED PCB board for 45/60KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete all as specified.
Supply and fixing in repair/replacement of LED PCB board for 90/100KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete all as specified.
Supply and fixing in repair/replacement of LED PCB board for 150 KW light fitting board thickness 1.6mm for Flood/street/highbay light fitting complete all as specified.
Excavation in trenches n. exc 1.5 mtr in depth and not exc. 1.5 mtr in wide and getting out in soft/loose soil for laying of cables complete all as specified.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil complete all as specified.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point complete all as specified.
M&L for sand filling in trenches as cushioning to under ground cable provided with a layer of 8 cm deep before laying and 15 cm covering above the top edge of cable after laying complete all as specified. Note :- Punned thickness only shall be measured and paid.
Laying only old retrieved stone putty/brick/PCC cover on the cable abutting each other for the cable protection gap between two adjacent patties n.exc 10mm complete all as specified.
Material and labour for laying 40 to 50 mm thick quarry faced stone slab 25 to 30 cm wide and not exceeding 60 cm long laid dry abutting each other with gap between adjacent patties n.exc 10 mm for cable protection complete all as specified.
Taking out existing old/rusted GI tubing of any size from pole/ trenches for necessary and Supply and lay light grade GI pipe with all fittings complete laid in trench/ fixed to Wall / Poles etc with suitable clamp for any type of pole, nuts, bolts washers etc required at site for protection of cable of the following sizes:- (a) 25 mm dia
All item as per Ser No 28.00 above but 40 mm dia
All item as per Ser No 28.00 above but 50 mm dia
M&L PCC (1:4:8) type D-2 using 40mm graded aggregate as in foundation for filling in, mass concrete for pole and stay complete all as specified.
M&L PCC (1:3:6) type C-1 using 20mm graded aggregate as in coping of pole etc including form work complete all as specified.
Material and labour for re-fixing of danger notice/safety board above HT/LT steel tubular/ PCC pole and to be maintained a suitable ht from ground level with proper alignment with Digital printed on retro reflective sheet (letter should be not less than 5CM in Red Colour) in HIndi and english both language complete all as specified. Note :- Old two number of MS clamps suitable for steel tubular/PCC pole to be replaced by new one and including nut-bolts is inclusive in above quoted rate.
Supply and fix GI bracket of medium grade 40 mm bore GI tubing not less than 1.50 mtr long bend to required shape as in bracket for street light fittings fixed with two pair of MS flat iron clamp suitable for steel tubular/PCC pole as per site requirement with 4mm thick and including accessories i.e new nut-bolts and washers and other petty items required for fixing including painting with two coats of synthetic enamel paint over a coat of redoxide primer complete all as specified.
Supply and fix MCCB 4 Pole 100A Amps 415V 16KA and taking down existing unserviceable from its own position complete all as specified.
Trimming and cutting of tree branches coming across LT over head line, clearing the line around 1.5m and disposal of shrubs to a distance up to 500mtr distance and cleaning the site complete all as specified. Note :- (i) Length of span shall be 45 to 50m. (ii) Due care shall be given while trimming/cutting the tree branches that there shall be no damage to over head line conductor/pole. In case, due to any negligence, damage is caused, it shall be made good by the contractor and nothing extra shall be admissible. Note : All T&P shall be provoded by contractor
M & L for rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc., Supplied & fixed External dia in 20 mm, complete all as specified and as directed by the Engineer-in-Charge
M & L for earthing complete with galvanised steel earth plate electrode 60cmx60cmx 6.3mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion complete all as specified and as directed by the Engineer-in-Charge
M & L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire complete all as specified.
Dismantling & taking down of old/rusted/broken PCC pole from its existing position and Supply & fix steel tubular swaged poles complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified type 410 SP-31 (9.0 metres long) complete all as specified.
M&L for dismantling PCC for coping/base foundation of PCC/steel tubular pole complete all as specified.
S&F in reapir of cable lugs upto 25mm size properly fixing in junction box (incoming and outing boths cable ) properly tighting complete all as specified.
S&F in reapir of Connector three phase with netural upto 40Amp properly fixing in junction box suitable for incoming and outing cables properly tighting complete all as specified.
M&L for locking system at junction box with suitable clamps for fixing the box as site requirment complete all as specified.
M&L for Danger notice plate of 1.6mmthick mils steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal redcolour and fixed wih M.S clamps bolts and nuts of approved size for LT20x15cm size complete all as specified.
Supply only Surge Protector 10KV for street light fitting, Normal voltage input range : 170- 300 volt complete all as specified.
Supply and fixing in repair of 18 Amps Contactor MNX18 with 1 NO 3 Phase complete all as specified.
Nvimal Engineers and Contractor (BID ID -3116102)
Shri Electrical Enterprises (BID ID -3117202)
vinayandsons (BID ID -3116620)
LOKESH ELECTRICAL WORKS CONTRACTOR (BID ID -3128438)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .