Executive Engineer, Public Health W Division, Jetpur
Working Survey, Design, Build & Operate Contract for Providing, Supplying, Laying DI/PVC Pipe Line, Testing Commissioning of WTP, U/G Sump, Pump House and Pumping Machinery for Bhadara Regional Augmentation Water Supply Scheme including Comprehensive Operation & Preventive maintenance for supply of water (Incl Fofal RWSS) for 120 months. Taluka: Jamkandorna, Jetpur, Dist:Rajkot
292418
03/2025-2026
Open
Civil Works - Water Works
Works
Rajkot
6 documents required · 6 mandatory
₹24,000
Executive Engineer Public Health Work Division Jetpur
₹31.7 L
1 Apr 2026
1 Apr 2026
1 Apr 2026
30 Apr 2026
1 Apr 2026
Name of Work: Bid documents for Working Survey, Design, Build & Operate Contract for Providing,
Supplying, Laying DI/PVC Pipe Line, Testing Commissioning of WTP, U/G Sump, Pump House and
Pumping Machinery for Bhadara Regional Augmentation Water Supply Scheme including Comprehensive
Operation & Preventive maintenance for supply of water for 120 months. Taluka: Jamkandorna, Jetpur,
1) The bidder shall quote his firm and fixed price for the entire work under this Contract, defined in
more details in various sections of this bid document
2) The rates and prices shall be submitted in the electronic formats given by n-procure which is
called Schedule-B. Rates and prices received in any other formats will be rejected and the Bids will
be disqualified.
3) It will be entirely at the discretion of the Employer to accept or reject the bidder's proposal,
without giving any reasons whatsoever and the bidder shall not be permitted to withdraw his bid on
from the by client
5) In Schedule-B the Bidder shall quote prices for the items on % tage rate of overall work / lump
sum / unit rate as called for against the BOQ item
tentative quantities of the work there of for the guidance of the bidder. For any excess over tender
quantities, Extra items and variations in quantities, Refer Clause No 14 of Volume IB-General
Conditions of Contract
7) The total of the item prices in Schedule B1, Schedule B2 shall be equal to the price quoted by
except for items under-price variation clause. In case of any discrepancy noted in the various price
schedules, those in Schedule B will be considered and binding on the Contractor. The prices in
Schedule B1 Schedule B2 of the successful bidder shall be corrected accordingly.
8) The bidder is not required to quote their prices in Schedule C O&M prices. The rates mentioned
in the Schedule C for O&M are fixed and will be the basis for payment during O&M as per tender
terms and conditions. The Amount of Schedule-C shall not be carried forward to Schedule B for
comparison and evaluation. But it shall be added to schedule) B (After rebate, if any) for overall
cost of tender & shall form a part of the Contract Agreement.
9) Wherever for a particular item the quantities have been specified payment shall be on unit rate
basis and unit Variation in quantity will be paid with pro rata basis.
10) Each item is to be individually/ Overall work is to be % tage base priced online and the
Schedules of prices shall be left blank except where the item description requires the item to be
priced on "as applicable" basis. The item shall not be priced if it is "not applicable to the bidder's
design, in which case the bidder shall add the words "NOT APPLICABLE. The wording in the item
Volume-III, PRICE BID AUG. OF Bhadara RWSS
description is for subject matter guidance only, clause references are indicative only and all other
relevant clauses shall also be referred to. The prices shall allow for all the works covered under the
bid and all liabilities and contractual obligations whether separately specified or not. Items against
which no prices are quoted shall not be separately paid for and the bidder shall be deemed to have
covered the cost of execution of such items (according to the requirements of the bid document) in
the prices quoted for other items.
working/safety of the system as specified, will not be separately paid for by the Employer when
executed and shall be deemed to be already covered by other items and rates listed in the price
sheets No extra payment shall be given for any item which is required to complete and perform the
12) Bidder shall not to quote for O&M in Schedule-C. In case of any discrepancy noted in the
13) Schedule 'D gives the basis of interim payment for construction of civil works
considered for financial evaluation of the bid.
15) The bidder shall be deemed to have allowed in his price for provision, maintenance and final
removal of all temporary works of whatsoever nature required for construction including temporary
bunds, diverting water, pumping, de-watering etc. for the proper execution of works. The rates shall
also be deemed to include any works and setting out that may be required to be carried out for
laying out of all the works involved.
16) Prices shall be filled online only.
Specifications and other sections of these bid documents and these documents are to be taken as
mutually explanatory of one another.
18) The bidder shall interpret the data furnished and carry out any additional survey work, or
investigation work required at his own cost.
19) The prices quoted shall also include the cost of materials utilized for testing.
20) The bidder should acquaint himself with the site conditions including the access to Work site.
The successful bidder shall have to make suitable access to work sites at his own cost. These
accesses will be used by the other contractors working for GWSSB.
shall include all the equipment / materials / accessories and services required as per the
22) 1% of the value of work will be deducted from the Running bill against labour cess which is
non-refundable.
23) Third Party Inspection / CSC agency will be deployed by GWSSB and charges of the same will
be borne by GWSSB
Volume-III, PRICE BID AUG. OF Bhadara RWSS
24) Any expenditure incurred by inspection/ CSC agency for the work misinformed by the
contractor and charges of inspection/ CSC agency without any work due to misinformation shall be
recovered from the contractor
25) The prices shall be quoted prices shall be quoted exclusive of GST, but inclusive of all other
taxes, royalties and duties prevailing at the time of submission of the bids. Statutory variation if any
during the currency of contract shall have to borne by the agency which shall be not reimbursed by
26) The rates quoted shall be the approved tender rates and tender conditions of price variations
GST shall be paid as per prevailing rates at the time of payment. The TDS shall be deducted at
source as per provision of IT rules and GWSSB policy.
27) The rates should be quoted exclusive of GST but inclusive of all other taxes as per Volume -1
(B), General conditions of Contract, Clause No.
28) The Bidders shall have to quote the rates in this tender keeping in view of the GST. The
Complete responsibility of taxes, duties, levies rests with the Contractor/Agency only.
29) The process requires that the bidder shall quote his price for the work components contained in
period of performance of the contract except price variation allowed for supply of MS/DI/PVC/GI
pipe as per Volume-1 (B) Clause No. 59. General Conditions of Contract
30) Payment shall be made for the components for which lump sum prices are quoted, as per the
schedule of payment. Total cost will be worked out on the basis of work done of individual items
and rates quoted against those particular items only.
31) Royalties. The contractor shall be liable to pay the royalty of the quarried materials/ minerals
used in the construction of works at the rates specified in the Narmada Water Resources, Water
Supply & Kalpasar Dept. Resolution No. GEN-2010-595- (6)- M.I.Cell (K-1) Dt. 29-4-2011,
(Gujarati Version Copy enclosed) and shall be recovered from the running bills of the work from
time to time and remaining amount if any shall be recovered from the final bill before releasing the
security deposit of the work. The contractor shall furnish the statement showing the quantity of
quarried materials / minerals from whom purchased (with full address of the seller) and copies of
the bills for purchase to the Executive Engineer of the in charge of the work. The contractor shall
also furnish such additional information as regards royalty payment to the competent authority
32) Agency shall have to take Insurance policy and intimate to GWSSB along with the evidence
within time limit. In case of noncompliance entire responsibility shall be rest with the agency and
required amount shall be recovered from any due amount of the agency.
33) GWSSB can recover penalty amount from the agency for not taking the insurance. Though the
penalty amount is recovered, responsibility of the agency for taking insurance shall be continued
and will not be escaped from the responsibility.
34) If There is provision for dismantling & buyback of old pumping machinery HSCF/HMSM pump
set with co-ordinated mechanical accessories, Electrical equipment’s etc. The details of buy back
items with quantity is shown in schedule-E of price bid. The buyback amount is considered as per
abstract sheet of buyback and will be deducted from agency bill.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
35) The agency shall be procure & supply 1 Color Printer and 7 sets Personal computer system
with multi- Function Printer free of cost within 1 month from date of Work order to sub Division
office Dhoraji Sub Division office as per instruction by Engineer-in-Charge.
The configuration of computer system/Printer is as under.
Computer Operating System Windows 10 or latest edition.
CPU Model with Intel processor Core i5 – 11th generation @2.60 GHz
Brand HP or Lenovo
Screen Size 21 Inch And Above
Hard Drive Size 1 TB & Above
Ram Size 8 GB & Above
SD 500 GB & Above
Printer Brother L2541 dw Multifunction All in One Printer with Fax,scanner , Networking &
Color Printer Epson EcoTANK l6270 a4 Wifi Duplex Ink Tank Printer
Signature of contractor Executive Engineer
P.H. Works Dn., G.W.S.S.B
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Bidders are required to fill up all the blank spaces in this Bid Form.
THE EXECUTIVE ENGINEER,
PUBLIC HEALTH WORKS DIVISION,
SUB: Bid documents for Working Survey, Design, Build & Operate Contract for Providing, Supplying, Laying
DI/PVC Pipe Line, Testing Commissioning of WTP, U/G Sump, Pump House and Pumping Machinery for
Bhadara Regional Augmentation Water Supply Scheme including Comprehensive Operation & Preventive
maintenance for supply of water (Incl Fofal RWSS) for 120 months. Taluka: Jamkandorna, Jetpur,
1. Having visited the site and examined the Bid Documents, Drawings, Conditions of Contract,
including Addenda/Amendments to the above, for the execution of the above Contract, we the
undersigned offer to design, Engineer, procure, construct, complete, commission, operate and
maintain the whole of the said works for 5 years from the date of commissioning including
defects liability period as given in Conditions of Contract and in conformity with the drawings,
Documents, including Addenda Nos.__________ (insert numbers) for Lump sum fixed price of
Construction including free trial run for three months or such other sum as may be ascertained
in accordance with the conditions.
2. I/We agree that
a) If we fail to provide required facilities to the Employer’s representative or any other
person/Agency by the Employer to perform on his behalf for carrying out the inspection and
testing of materials and workmanship.
b) If we incorporate into the Works, materials before they are tested and approved by the
Engineer’s representative.
c) If we fail to deliver pure water of required quantity according to the
conditions/stipulations of the Contract, the Engineer will be at liberty to take any action
including termination of Contract and impose at his absolute discretion any penalties, and/or
reject the work.
3. We undertake, if our Bid is accepted, to complete and deliver the works in accordance with
the Contract within _________ months, inclusive of monsoons, from the date or receipt of
Letter of Acceptance issued to us by you.
4. We agree to abide by this Bid for a period of 180 days from the Last date of submission of the
bill and it shall remain binding upon us and may be accepted at any time before the expiry of
5. In the event of our Bid being accepted, we agree to enter into a formal Contract Agreement
with you incorporating the conditions of Contract there to annex but until such agreement is
Volume-III, PRICE BID AUG. OF Bhadara RWSS
prepared this Bid together with your written acceptance thereof shall constitute a binding
Contract between us.
6. We agree, if our Bid is accepted, to furnish performance /Security in the forms and of value
specified in the Clause 1 of Volume-IB, “General Conditions of Contract”.
7. We have independently considered the amounts of liquidated damages shown in Appendix to
Bid and agree that they represent a fair estimate of the damages likely to be suffered by you
in the event of the work not being completed by us in time.
8. We understand that you are not bound to accept the lowest or any Bid you may receive.
(Name of the Person)
Company Seal _____________________
Duly authorized to sign Bid for and on behalf of (fill in block capitals)
Witness Signature ___________________________
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Augumentation of Bhadara Regional Water Supply Scheme "
Taluka- Jamkandorna, Jetpur Dist-Rajkot
Name of Work- Working Survey, Design, Build & Operate Contract for Providing, Supplying, Laying
DI/PVC Pipe Line, Testing Commissioning of WTP, U/G Sump, Pump House and Pumping Machinery for
Bhadara Regional Augmentation Water Supply Scheme including Comprehensive Operation & Preventive
maintenance for supply of water (Incl Fofal RWSS) for 120 months. Taluka: Jamkandorna, Jetpur,
Schedule showing the material to be supplied to the contractor by GWSSB from store
specified below during the project execution work and during the M&R period after
commissioning the project.
Sr.No. Details of material Qty Rate Unit where material
Pipes and Valves for
Lowering, Laying and
(A) Nil Nil Nil Nil
Jointing during project
execution of work
Required pipes & Valves
(B) during the M&R period after Nil Nil Nil Nil
commissioning the project.
Necessary Bleaching powder
and PAC solution during the Department's
(C) M&R period after NA store anywhere
commissioning the project in Rajkot District
1. Materials not included in “Schedule – A” but required for the work shall be provided by the contractor
at his own cost.
2. Any materials required for items other than labour charges items mentioned in “Schedule – B” and
materials not included in “Schedule – A” but available with dept. will be issued on request of the
contractor at departmental issued rate or market rate whichever is more.
3. The contractor shall provide his own arrangement for loading, unloading and transporting the materials
issued by the dept. from store to site at his own cost. Contractor will be responsible for damages
whatsoever during transfer.
4. The unused materials issued by the department for this work shall be returned to the department in
good and acceptable condition by the contractors. Any such unused materials not returned by the
contractor in time or issued will be recovered at Double of (As per issue rate + 3% storage charge or
Board RC + 3% storage charges) whichever is more.
5. All materials such as Specials, Fittings, Spares, etc. shall be brought by Agency / Contractor at site of
6. The material which requires to be procured by contractor and same as available with the department
the same can be issued to the contractor after prior approval from the competent authority and
charged for the same will be at the current market rate or issue rate fixed by the department
whichever is higher. The contractor shall have to deposit total cost of materials issued or shall be
recovered from the running account bill.
7. The materials issued for the above work shall be used in the above O&M work only. If any of materials
issued for this work and found used in other works shall be charged at the double rate.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
8. As per the instructions of the competent authority and availability of materials, if needed contractor
have to transport the same from the other store to ………Scheme for which no extra carting, loading,
unloading will be paid.
9. The materials issued free of cost to the contractor is to be transported to the site of work in good
condition by the contractor for which no extra payment will be made.
10. The materials to be brought/purchase by the contractor shall be got approval from the EIC before using
Signature of contractor Executive Engineer
P.H.Works Dn., G.W.S.S.B
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Augumentation of Bhadara Regional Water Supply Scheme "
Taluka- Jamkandorna, Jetpur Dist-Rajkot
SCHEDULE:-B : ABSTRACT
(A) Civil Section
B1 Schedule:- B1- Rising Main and Gravity Main Pipeline including
B2 Schedule:- B2: Conventional Water Treatment Plant
B3 Schedule:- B3: Construction of R.C.C. Sump
B4 Schedule:- B4- Constuction of PUMP HOUSE (Positive/Negative
B5 Schedule:- B5 Compound Wall
B6 Schedule:- B6 Repairing of Existing ESR of 5.0 LL at Ujala SHW
(B) Mechanical Section
B7.1 Schedule:- B7.1 Pumping Machinery for Canal Intake Head Work
B7.2 Schedule:- B7.2 Pumping Machinery for Dam site WTP Head
B7.3 Schedule:- B7.5 Pumping Machinery for Head Work : Ujala SHW
Capital Work:Total Amount Rs.
Capital Work:Total Amount Rs.
( C) Operation and maintance (Excluding Village level Storage & Its
Ancilliary work)
C-A SCHEDULE C- O & M WORK (Part:A-Regular O&M)
C-B SCHEDULE C- O & M WORK (Part:B-Periodic Maintanance)
O&M 10 for years :Total Amount Rs.
O&M 10 for years :Total Amount Rs.
Grand Total for Overall work Rs.
Grand Total for Overall work Rs.
I/We am/are willing to carry out the work at __________% above/below _____________ percentage
(should be written in figure & words) above/below the estimated rates mentioned above/below
amount of my/our tender worked out as under :-
Estimated Amount put to tender Estimated Amount put to tender.
(In words Rupees________________ (In words Rupees________________
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
SCHEDULE-B1 to B6
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B1- Rising Main and Gravity Main Pipeline including Crossings etc
Quantity UNIT Amount
Item Description (only (upto 50 ( Upto
(upto 200 ( Upto
figures) characters) Decimals )
characters) Decimals )
1.1 Providing and supplying in standard length ISI mark rigid unplasticised PVC
pipes suitable for potable water with ring fit joint including cost of rings, as per
IS specification no. 4985/1988 including all local and central taxes,
transportation,freight charges, octroi, inspection charges, loading, unloading,
conveyance to the departmental stores and including cost of jointing meterial
200 mm Dia PVC pipe 6 kg/cm2 4830.00 Rmt 665.00
1.2 160 mm Dia PVC pipe 6 kg/cm2 17420.00 Rmt 420.00
1.3 140 mm Dia PVC pipe 6 kg/cm2 4389.00 Rmt 326.00
1.4 110 mm Dia PVC pipe 6 kg/cm2 2699.00 Rmt 199.00
2.1 Providing and supplying D.I. K-7/K-9 grade pipes for following nominal bore
diameter with internal cement mortar lining including all taxes, insurance
transportation, freight charges , octroi, inspection charges, loading, unloading
,conveyance to department stores,stacking etc complete (IS8329-2000).
500 mm dia D.I. K-7 Pipe 62.00 Rmt 6505.00
2.2 400 mm dia D.I. K-7 Pipe 153.00 Rmt 4583.00
2.3 300 mm dia D.I. K-9 Pipe 102.00 Rmt 3788.00
2.4 200 mm dia D.I. K-9 Pipe 204.00 Rmt 2239.00
3.1 Providing and supplying ISI mark CI D/F Sluice Valves as per IS:14846
(Latest Edition) of following class and diameter including all taxes, insurance,
transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking etc. complete.PN-1 With hand
wheel /cap operated (PD type short body)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
4.1 Providing and supplying C. I. Temper proof Air valves with SS 304 Float gun
metal- nozzle of approved make & quality of following class and diameter
including all taxes, insurance, transportation, freight charges, octroi,
inspection charges, loading, unloading, conveyance to departmental stores,
stacking etc. complete
50 MM Temper Proof Air valves with Isolating Sluice Valve PN 1.0 61.00 No 11221.00
4.2 80 MM Temper Proof Air valves with Isolating Sluice Valve PN 1.0 1.00 No 13789.00
5.1 Manufacture, supply & Delivery of Ductile iron Flange Socket spigot bends,
tees, reducers or any other specials as per BS-EN-545/1995 Class-A series
K12 suitable for use with D.I. Pipes manufactured as per IS: 8329/1994
delivery of specials is to be made to GWSSB store or site of works any where
in Gujarat including all taxes, loading, unloading, carting, stacking, insurance,
inspection charges, octroi etc. complete.
Socket & Spigot Type 80 to 300 mm Dia 110.00 Kg 148.00
5.2 Socket & Spigot Type 300 mm Dia & Above 140.00 Kg 151.00
5.3 Flanged Type 80 to 300 mm Dia 110.00 Kg 155.00
5.4 Flanged Type 300 mm Dia & Above 140.00 Kg 158.00
6.1 Excavation for pipe line trenches for water supply, sewerage line, manhole
etc. all with shoring and struting if required as per required gradient and line
including safety provisions using site rails and stacking excavated stuff
including up to all required lead cleaning the site etc. complete for all lifts and
strata as specified. (A) Upto 1.50 mt depth1) In all sorts of soil and soft
murrum 5218.00 Cum 89.00
6.2 2) In Hard murrum, boulders,inlc Macadam Road 5218.00 Cum 135.00
6.3 3) in soft Rock and / or masonary in C.M. or L.M.or Lime Concrete. 5218.00 Cum 163.00
6.4 4) in Hard Rock and / or in C.C.1:2:4 or R.C.C.With blasting and Chiseling or
by Chiseling only 5218.00 Cum 372.00
7 Providing bedding incl. ramming, watering,levelling, consolidating etc.
complete. As per standard and instruction of engineer incharge
As above with selected excavated earth available near site 2581.00 Cum 60.00
8.1 L, L & J PVC/uPVC/cPVC pipes and specials
Lowering, laying, fixing and jointing PVC/uPVC/cPVC pipes and specials of
following class and diameter including cost of conveyance from stores to site
of works including cost of labour, material, cement solvent, giving satisfactory
hydraulic testing as per ISI code. including providing and supplying and fixing
of all type PVC/MS specials and fittings suitable to PVC pipe required for LLJ
incl. freigtht, loading,unloading stacking insurance and all taxes etc complete.
Including additional Job connections to the existing pipeline or structure with
all required materials and manpower required for commissioning of
pipeline/Structure as per actual site situation.
200 MM PVC pipeline 6 kg/cm2/ / 8 kg/cm2 4600.00 Rmt 37.00
8.2 160 mm Dia PVC pipeline 6 kg/cm2 / 8 kg/cm2 16590.00 Rmt 28.00
Volume-III, PRICE BID AUG. OF Bhadara RWSS
8.3 140 mm Dia PVC pipeline 6 kg/cm2 / 8 kg/cm2 4180.00 Rmt 23.00
8.4 110 mm Dia PVC pipeline 6 kg/cm2 / 8 kg/cm2 2570.00 Rmt 19.00
9.1 Lowring, laying and jointing C.I. S & S spun pipes suitable for Tyton joints /
Mortar lined D.I. K-7 Pipes of various classes with CI / MS specials of
following diameters in proper position ,grade and alingnment as directed by
engineer in charge including hydraulic testing etc. comp.
500 mm dia D.I. K-7/K-9 Pipe 60.00 Rmt 312.00
9.2 400 mm dia D.I. K-7/K-9 Pipe 150.00 Rmt 225.00
9.3 300 mm dia D.I. K-7/K-9 Pipe 100.00 Rmt 155.00
9.4 200 mm dia D.I. K-7/K-9 Pipe 200.00 Rmt 99.00
10.1 Lowering, laying and jointing in position following C. I. / D/F Reflux valves,
Butterfly valves, Sluice valves and Air valves including cost of all labour,
jointing material, including nut bolts and giving satisfactory hydraulic testing,
A) Sluice Valves
10.8 B) Air Valves:
1) 50 MM Temper Proof Air valves with Isolating Sluice Valve PN 1.0 61.00 No 757.00
10.9 2) 80 MM Temper Proof Air valves with Isolating Sluice Valve PN 1.0 1.00 No 811.00
11.1 Erection of air valve Riser by installing new M.S. pipe of 6mm thick and
mt length with necessary fittings such as flange of appropriate size, nut, bolts
and embedded the pipe in R CC M;15 with offset of 10 cm around the pipe
with necessary steel etc complete.
1) For For Air valve 80 MM Dia & MS Pipe 2.00 No 4350.00
11.2 3) For Air valve 50 MM Dia & MS Pipe 61.00 No 3112.00
12.1 Construction of valves chambers in brick or bela stone masonry, locally
available in C. M. 1:6. Foundation concrete 150 mm thick in C. C. 1:4:8 of
trap metal size 25 mm to 40 mm thick, inside cement plaster in C. M. 1:3 and
cement pointing outside in C. M. 1:3 and top cover of precast RCC slab
mm thick (with key hole in two parts, each with handles or MS Bar etc.
complete as given size) Upto 1 Mt. depth from G. L. to pipe invert level incl.
complete civil works but excl. cost of excavation and refilling, with cast in situ
RCC slab in one single piece with fixing of CI-MH Frame and cover (excl.
cost of CI-MH Frame and cover) with 23 mm thick brick masonry wall in
C.M.1:6 With precast slab in two parts 15 mm 2.00 No 11351.00
Volume-III, PRICE BID AUG. OF Bhadara RWSS
(1) For Valve size 300/250 MM
1.1) Size of 1.30 m x 1.30 m and 1.0 m deep
12.2 1.2) For 1 Mtr. Extra Depth for Size of 1.30 m x 1.30 m and 1.0 m deep 1.00 Rmt 6084.00
12.3 (2) For Valve size 200 MM To 80 MM
2.1) Size of 0.90 m x 0.90 m and 1.0 m deep 11.00 No 7738.00
12.4 2.2) For 1 Mtr. Extra Depth for Size of 0.90 m x 0.90 m and 1.0 m deep 4.95 Rmt 4479.00
13 Providing CC M 100 for encasing pipes using trap metal size 12 mm to
mm incl. form work curing consolidation etc complete for various location on
pipe line. Using trap metal 20mm nominal size 290.00 Cum 4113.80
14 Providing and casting in situ C.C. in grade M-15 (approx. corresp. to prop.
1:2:4) (proportions as per mix design or as per Table 9 of IS456 2000 in
masses by weigh batching ) using granite, quartzite trap metal of size 6 mm
to 20 mm for RCC work, including scaffolding centering, form work, needle
vibrated consolidation, curing comp. up to 6 meter depth or height (excluding
cost of reinforcement and neat finishing) with centering and shuttering/
deshuttering etc. comp. for structure for otherthan water retaining. upto
Footing or foundation (with form work) 192.00 Cum 4906.00
15 Supplying cutting, bending, binding and placing in position steel as per plan
and design and as per ISS 2502 including cost of steel and binding wire for
reservoirs/structures only including lift up to 6 meter height or depth below
G.L. For all diameters
Do-Thermo mechanically treated (TMT)bars Fe-415 grade for all diameters. 4800.00 Kg 73.208
16.1 Refilling the pipeline trenches incl. ramming, watering, consolidating
desposal of surplus stuff as directed within a radius of 3 km.
1) With selected soil brought from outside incl all lead. 1924.00 Cum 175.00
16.2 2) Refilling as directed. (From selected excavated stuff) 15654.00 Cum 22.00
17.1 Labour charges for Extra work for Job Connections for connecting of existing
structures or pipeline with proposed structure or pipeline in time bound
schedule incl. procuring of all types of tools and plants required for the job,
excavation, dewatering, cutting of all types pipe, required welding, installation
of all type of required specials, Hydraulic testing, refilling etc comp. excl.
pipeline material.required for connection
For Major size 300 MM Dia DI Pipeline 3.00 No 1500.00
Volume-III, PRICE BID AUG. OF Bhadara RWSS
17.3 For Major size 200 MM Dia DI Pipeline 3.00 No 1000.00
17.4 For Major size 200 MM Dia PVC Pipeline 1.00 No 625.00
17.5 For Major size160/140/110 MM Dia PVC Pipeline 4.00 No 375.00
18.1 Drilling of Horizontal bore hole for water main pipeline under the
Railway / Road tracks in all strata with required length including fixing
of M.S.(or as specified by Railway / Road authority) casing pipe of
suitable size and Thickness. Rate includes the cost of Drilling of bore
hole , Casing pipe & welding pushing etc complete but excluding the
cost of water main, valves and other items. Entire work should be as
per Approved Drawing and as per instruction of Railway / Road
authority for Following diameter of Bore hole. for MS pipe
Horizontal Drilling-600:& MS Casing Pipe-500 thick:8 25.00 Rmt 9166.00
18.2 Horizontal Drilling 500 & MS Casing pipe-400 thick 6 75.00 Rmt 6439.00
18.3 Horizontal Drilling 250 & MS Casing pipe-200 thick 5 50.00 Rmt 2148.00
19 To carry out survey work Co-Ordination liasation for "Standing crop
compensation"in land for laying water supply pipeline along the
alignment of Augmentation of Bhadara Regional Water Supply
Scheme including shifting of center line marking it on village map and
hissa to be taken for Standing crop compensation and submission of
drawing in 4 sets drawn in the scale of 1 cm=25 mt.along with original
tracing showing and marking their own survey numbers with CD
nos. etc. and defining Standing crop compensation strip of 15.00 m.
along the cross country in width on the map and showing revenue
survey number wise area and other details as per detailed
specifications. For Job work for legal formalities including getting
copy of 7/12, 6-A,form of perticular land non judicial Stamp paper, &
all required activities with all documents. For Job work for legal
formalities including getting 7/12, 6-A, non judicial Stamp paper, & all
required activities with all documents. 337 Nos 435.00
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B2: Conventional Water Treatment Plant
Quantity (upto Tender Rate Amount
Item Description (only 50 ( Upto 2 ( Upto
figures) charact Decimals ) Decimals )
1.1 Designing (hydraulic, process, structural and aesthetic),constructing and commissioning
Conventional Water Treatment Plant consisting of all Civil, Mechanical and Electrical
components of various sub- works as given below including necessary hydraulic testing,
structural testing, equipment testing, trial run for 3 months, etc. complete as directed by
Engineer-in-charge (turn-key job). The design shall conform to IS / CPHEEO Manual.
2.1)Aeration Fountain/Casecade Aerator.
2.2) Ventury Flume / Partialflume With necessary flow measuring devices/meter consisting of
mechanical/digital indicator.
2.3) Flash Mixer: Rapid mixing device design confirming to IS : 7090 of 1985.Detenion time
60second, velocity gradient 300-400 sec-1 with fans gear and motor assembly as per design.
2.4) Flocculator : Design confirming to IS : 7208 – 1974 (Type-C) .Detention period 30miutes
with flocculator paddles with gear and motor assembly as per design .
2.5) Clarifier : Circular tank with horizontal flow pattern, detention period 2.5 hours, overflow rate
30 cubic meter per square meter per day (to be specified), Weir oading not more than 300 cubic
meter per meter per day, with mechanical sludge scraper confirming to IS : 10313 – 1982 and
bridge as per design with gear and motor assemblies.
2.6) Rapid Sand Filters and Filter House : Filter designed for filtration rate of 6,000 liters per
square meter per hour, minimum 2 beds for plant up to 10 MLD, for larger plants as specified,
pipe gallery and platform minimum 5.5 meter in width.
a) Filter Media Effective size of filter sand 0.45 to 0.70 mm, uniformity coefficient not more than
1.7 nor less than 1.3, depth of filter 0.75 M, free board 50 cm, gravel 0.45 M in depth, sand and
gravel conforming to IS : 8491 (i) – 77, backwash by air wash(if specified) and hard wash by
water, standard appurtenances (to be specified), rate of flow controller, filter gauge, sand
expansion gauge,etc.
(b) Wash water tank : Wash water tanks of capacity equal to 2% of designed quantity of filtered
water in a day (+) 10% with 8 to 10 m head (as specified) Wash water tank shall be constructed 1 No. 16106832.00
Volume-III, PRICE BID AUG. OF Bhadara RWSS
on RCC column/slabs only.
(c) Wash Water Pumps : Capacity to fill water tank in 1 hour with 100% standby.
(d) Air Blowers : Capable of delivering 600 LMP per square meter of free air, of filter area with
pressure@ 0.4 kg/square cm at the underdrains (100% standby).
(e) Valves/gates :Inlet, outlet, wash water inlet –outlet and all types and sizes of valves/ gates as
per design. (MOC of gate shall be CI)
(f) Gauges/meters : All types gauges and meters required for filter operations and backwashing
etc. asper design of specified make/brand.
2.7) Chemical House in Two Stories (floor wise area as specified) RCC framed structure with
brick masonry infill walls .ground floor and first flour area as per data/specifications shall be
provided. Minimum clear head room for doors, passages, galleries etc. shall be 2.10 m. It shall
be 2.40 m in case of Alum dosingtank.Ground floor to accommodate 90 days alum requirements
a) Sundrystorage
b) First floor to accommodate alum and lime tanks,etc.
c) SolutionTanks
Minimum 3 tanks (one for preparation, second for dosing and third as standby), each tank
capable of giving 8 hours maximum dose without terruption,minimum free board 0.30 M, trays
for dissolving, level indicator, mechanical agitation devices, solution feed and drain lines,
solution feed device constant head device, strength of solution up to 10% only) confirming to IS :
2.8) Store House (area as specified) : Suitable for alum storage of three months requirement in
monsoon with 10% extra capacity for other sundry articles.
2.9) Vacuum feed type Chlorinators – make to be specified and approved by GWSSB.
a) conforming to IS : 10533 – A Part –2/1983.
b) Rate of withdrawal shall be as per clause 6.1Table-1 confirming to IS 10553 (2)-1983
c) Chlorinator equipment and container room to confirm to IS: 10533 Part – 1/1983.
d) 100% standby shall beprovided. Chlorinator equipment and container room to confirm to
(d) 100% standby shall be provided.
2.10) By pass arrangements – C.I. or M.S. pipes (as specified) of size as per design Drainage
arrangements – RCC pipes up to plot boundary (as specified ) diameter as per design.Drainage
arrangements – RCC pipes up to plot boundary (as specified ) diameter as per design.
(Backwash drain with RCC pipe to plant boundery Or to recirculation sump),
(Clarifloculatorsludgeremoving drain with RCC pipe)
2.11) Electric installation : Both internal and external including entire plant area (as specified).
2.12) Laboratory equipments : As per requirement (to be specified during tendering).
2.13) Sanitary blocks : Carpet area – 15 square meter minimum up to 25 MLD and 25 square
meter above 25 MLD (or as specified).
2.14) Administrative block and internal roads : To accommodate office room, chlorine room,
laboratory room, panel board room, blower room etc. and asphalt road to connect all units from
main gate of plot.
2.15) Dewatering during entire work using any technique:Necessary Instrumentation and control
as per specifications (for ≥10 MLD WTP).
Volume-III, PRICE BID AUG. OF Bhadara RWSS
2.16) The plant shall be provided with required instrumentation equipment for measurement &
control functions, indicated below as a minimum, but not limited to the following:
Rate of Flow (ROF) Measurement at WTP Inlet Parshall Flume and at each Filter Bed Outlet.
Flow Meter shall be Ultrasonic type with remote display to indicate level and
corresponding/proportionate Flow values on field.
Torque switch at Clariflocculator for alarm of Overload and Trip function of Clariflocculator
Loss of Head (LOH) Measurement across each Filters. LOH Meter shall be Ultrasonic type with
remote display to indicate level values and Head Difference on field.
Level measurement at each Sump/ Tank/ ESR. Level Indicator shall be Float & board type to
indicate level values on field. Level switch shall be Displacer/Float type with Low & High set
point to start/ stop respective pumps.
Float & Horizontal Scale type level gauge at Chemical dosing tanks to indicate level values on
Pressure Gauges at each pump/ blower delivery line and at common header.
Constant Head Flow Measurement at Alum dosing tanks with Float operated flow meter. All
alarm/indications shall be provided in instrument chamber of MCC.pH indicator cum Transmitter
(Online Analyzer) to measure, display & transmit pH Value of Raw Water (Location: WTP
InletParshall Flume) and Clear Water (Location: CCT Outlet).Turbidity Indicator cum Transmitter
(Online Analyzer) to measure, display & transmit Turbidity Value of Raw Water (Location: WTP
Inlet Parshall Flume), settled water (Location: Clariflocculator outlet) and Clear Water (Location:
CCTOutlet).Chlorine Indicator cum Transmitter (Online Analyzer) to measure, display & transmit
Residual Chlorine Value of clear water (Location: CCT Outlet) and Chlorine Leak Detector at
Chlorination Room.Sampling Pump for Sampling to Laboratory at Raw Water Channel,At Inlet to
Filter & Outlet to FilterPLC based control panel with SCADA system shall be provided in central
control room of treatment plant for monitoring, control, recording, and logging etc. Necessary
alarms, status signals along with the measurements of process parameters etc. shall be
displayed in SCADASystem.Additional instruments & control equipments if any for safe, reliable
& efficient operation of treatment process.
Following conditions shall form a part and parcel of thetender
Filter house tiles should be glazed vitrified mat finish and tile on wall up to window sill. Around
valve area granite flooring to be provided.
All channels should be with inside china mosaic/epoxy coated.
All railing should be SS railing (SS 304) as per latest IS standard.
External paint should be of weather proof coating with primer and 3 coat paint
Opening of window & door should be framed with granite.
All platform for kitchen/laboratory shall be of granite and fixed in sandwich with bottom of
kota/white marble.
All Window shall be of Anodised Aluminum section (1.2mm guage section) with wired glasses,
also provided with grill / jaali/aluminium weldmesh to prevent birds entry.
Doors shall be of anodised aluminum section(1.2mm guage of section) partial glazed and partial
panel with 4mm backelite sheet. Main entry door should be 2.0meter wide with 3.0mtr entry
Roof top of all unit of the WTP is approchable through staircase. All staircase of entire WTP
Volume-III, PRICE BID AUG. OF Bhadara RWSS
should be RCC only.(No MS ladder or No MS Staircase)
Bathroom should have shower facilities.
Chlorination neutralized pits(Lime pit) shall be made and mock drill practice for leakage
neutralization to be carried out while commissioning Fire safety equipment with Safety kit.
At chlorination room safety mask and hand gloves, gum bootsetc.should be available.
All vehicle access roads shall be of RCC and balance of Paver block type
Proper arrangement shall be made for storage of PAC solution and Alum with arrangment of
vertical lifting of platform through guide rails operated by motors.
Proper sludge disposal arrangement shall be made with sludge drying beds
All building terrace shall be finished with high quality water proofing like china mosaic flooring
with proper slope and drainage for rain water
Minimum plinth height of filter house shall be 0.6 m. Also outlet channel RL shall be at plinth
Clear walkway excluding column and valve operating valves shall be 1 meter.
Air blower shall be placed on ground floor Pipe gallery shall be embedded in flooring Inlet pipe
from flash-mixture to Clariflocculator shall be epoxy coated.
Flooring of Loading area like tonner/alum store etc. shall be of Polished Kota stone flooring and
open/other space shall be of paver block pitching.
(1) Conditions from Sr. No. 2 to 2.16 shall from a part and parcle of the tender and must be
incorporated in draft tender papers of conventional treatment plants.
(2) Aerator must be provided.
(3) Hydraulic design criteria approved by Technical committee shall be referred and item
description shall be modified accordingly
(4) Structural design criteria approved by technical committee shall be applicable for design.
(5) Design flow shall be specified in M^3/hour in data sheet considering 22 hours WTP run time
in a day to treat requirement water quantity of a day (i.e.24 hours) of population to be served
with design rate of water supply. No separate overloading provision shall be kept in any tender
(6) All other details shall be as per design criteria and detail specifications
(7)The following rates are for sites falling in relevent seismic zone.
(8) The rates includes excavation ,refilling and throwing away extra stuff to lead up to 50 m.
(9) All Civil Structural shall be Designed For Considering Seismic Zone 3 of RajkotDistrict
(10) The following rates are for preliminary or rapid estimate of WTP.
1) At Proposed Fofal Dam site HW-13 MLD
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B3: Construction of R.C.C. Sump
Quantity Tender Rate Amount
Item Description (only ( Upto 2 ( Upto
(upto 200 characte
figures) Decimals ) Decimals )
characters) rs)
1.1 Const. of RCC HGLR/Sump in cocrete Grade Preparing structural design of RCC Under Ground /
Partially under ground / above high ground level Reservoir of required capacity as per relevant
I.S.s and constructing the same, including excavation in all types of soil strata (including rock)
including shoring strutting if required, for loose soil / to protect from collapse due to near by traffic
load, casting 100 mm thick P.C.C. leveling course in M-15, Refilling the pit with proper soil and
disposing of the surplus stuff within a lead of 50 meters. Including cement plaster in CM 1:2 with
approved water proofing compound to inside water touching surface to container. Including all
types of labour and material charges of lowering, laying, erecting / hosting and jointing of pipe
assembly to inlet, outlet overflow, washout and bye pass arrangement as per hydraulic design.
Providing and fixing accessories like MS / GI Ladder, CI Manhole frame and cover, water level
indicator, adequate cowl type ventilators or lantern type ventilator with stainless steel jail.
W.S.Bella Masonry chambers for valves. Providing and applying three coats of cement paint /
snowcem to the out side face of structure. It also includes satisfactory water tightness test as per
relevant I.S. code and painting name of scheme and capacity on the tank as per direction of
engineer in charge. List of Indian Standards for Design of GSR / SUMP:- The structural design of
GSR shall be in accordance with provisions relevant I.Ss. (1) I.S. 3370, Part – 1 to 4, 2009 or
latest revised IS 3370-2009. (1.1) I.S. 3370 parr iii & IV 1965 or latest Revised (2) I.S. 456 –
2000 or latest revised. (3) I.S. 1893 – 2000 – 1984 or latest revised. (4) I.S. 875, Part – 1 to
1987 or latest revised. General Specifications:- (1) Water depth in container shall be adopted as
per data of tender. Capacity shall be calculated excluding free board of the reservoir. If water
depth is not specified, the suitable water depth / acceptable to field engineer in accordance with
hydraulic. (2) Shape of container (in plan) specified by in data shall be adopted in absence circular
shape shall be adopted. (3) Size shall be fixed as per availability of space (land area) at site /
acceptable engineer in charge. (4) Effect of overlapping of pressure bulbs on soil due near by
structure and proposed sump should be considered. (5) Care shall be taken that no damage
should occur to nearby existing structure. Compensation shall be paid for the same by agency. (6)
The minimum concrete grade for RCC shall be M-30. (7) HYSD Fe 415 / 500 grade reinforcing
bars confirming to I.S. 1786 / 1139 shall be considered in design. CRS / TMT bars shall be
provided. In saline atmosphere corrosion resistance stainless steel / HCR rebar shall be provided.
Any other steel can be used with approval of C.E./ in situation of non availability in market without
extra cost. (8) Minimum size (or thickness) of various components shall be provided as per tender
criteria / specifications in absence as per I.S./ Std. practice of G.W.S.S.B. Minimum dimensions
specified for various components in tender data / specifications shall be provided without fail. (9)
The safe bearing capacity (SBC) shall be referred from SBC test report. In absence of report it
shall be referred from data sheet. If poor soil is found / water table is met with during excavation
SBC shall be scientifically ascertained and design shall be revise. No extra shall be paid for
increase in quantity. (10) DI pipes and special shall only be used if type is not specified in tender.
(11) The rate shall include cost of dewatering during excavation making all arrangement when
water table meets within depth. (12) The structure shall be designed properly to resist uplift due to
ground water table specified in data or actual ground water table meets with during excavation. If 1.00 No 8706083.04
Volume-III, PRICE BID AUG. OF Bhadara RWSS
GWT / Uplift is mentioned in tender and during excavation it dose not meet 7.5% rate shall be
reduced. (13) SS pipes railing shall be provided over sump perifery when sump height is grater
than equl to 1.5 meter above ground level. (14.a) RCC staircase/RCC Steps should be provided
from GL to sump top slab based on the height of the GSR above/below the ground. 14.(b) RCC
Staircase with SS railing to be provided inside reservoir container. BB Masonry staircabin to be
provided to cover the same with MS safety door having locking arrangement to be provided for
GSR,Sump and HGLR of capacity more than 7.50 Lakh liter with top slab. if dome is constructed
as top slab then provide minimum opening of 900 mm X 2000 mm with curbing & SS railing
around. (15) Appearance of structure should be aesthetically good looking acceptable to
authority. (16) Any change in size, shape, depth below GL, height above GL, water depth, F.B.,
size of member etc can be permitted in exceptional case due to site condition or hydraulic design
requirement by C.E. No extra shall be paid for change. (17) Any change in data, dimensions,
shape, water depth, reduction in size if permitted by competent authority and if it reduces quantity
then payment shall be reduced prorate. (18) When capacity of GSR / Sump is grater than 20 lakh
litres two or suitable compartments acceptable to executive engineer shall be designed and
provided. (19) Agency shall engage qualified (at least graduate) consulting engineer for designing
the structure and he / she shall visit the site for guidance of work. (20) 75% part rate shall be
payable for concrete, reinforcement and plastering items of container until satisfactory hydraulic
testing for water tightness is performed as per tender condition. Till the work shall be treated as
incomplete. Above conditions / general specifications Sr. No. 1 to 20 are part and parcel of tender
(contact) and prevail over other provisions in tender. All Civil Structural Design for SUMPS shall
be Designed For Considering Seismic Zone 3 of Rajkot District
1) At Proposed Fofal HW-40 Lac Litre
As above rectangular Sump without water table (Sub soil water level below foundation)
1.2 2) At Existing HGLR of Zone-1: 2.0 Lac Litre
As above Circular HGLR without water table (Sub soil water level below foundation) 1.00 No 684691.70
1.3 3) At Canal Intake RW-15 Lac Liter
As above Rectangular Sump with water table (Sub soil water level below foundation)
The sump size (LXB) should be kept as per the limited land available. Also, the depth (D)
should be kept as per the hydraulics to get sufficient water from the canal at the sump inlet
and as per the turbine pump operating in the pump house to be constructed above the
sump itself. 1.00 No 4195721.43
1.4 4) At Ujala SHW of Fofal 1-2-10 Lac litre
As above circular Sump without water table (Sub soil water level below foundation) 1.00 No 2726737.77
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B4- Constuction of PUMP HOUSE (Positive/Negative Suction)
Quantity UNIT Tender Rate Amount
Item Description (only (upto 50 ( Upto 2 ( Upto
figures) characters) Decimals ) Decimals )
1.1 Item No.1: Designing (aesthetically) and constructing R.C.C frame
structure of pump room with positive suction (up to 6 mtr. Height Plinth
level to Top slab beam bottom) with gantry structure
1. Minimum 15 % opening for ventilation shouldbe provided.
2. Pump room rolling shutter, door and windows
should be provided (Included in Cost).
3. Plinth level of Pump house should be min.1 meter above GL.
4.Cost does not include foundation for pumping
1) At Proposed Fofal Dam site HW for CW Sump
36 Mt X 12 Mt X 6 Mt Positive Suction with Gantry Structure 432.00 Sqm 15301.72
1.2 2) At Canal Intake over RW Sump
12 Mt X 8 Mt X 6 Mt with gantry Structure (Min.4.5 M) upto 6.0 M (Plinth
to top Slab beam bottom Turbine Suction 96.00 Sqm 15301.72
1.3 3) At Ujala SHW of Fofal 1-2 Scheme
15 Mt X 8 Mt X 6 Mt Positive Suction with Gantry Structure 120.00 Sqm 15301.72
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B5 Compound Wall
Quantity UNIT Amount
Item Description (only (upto 50 ( Upto
(upto 200 ( Upto
figures) characters) Decimals )
characters) Decimals )
1 Item No.1: Construction of compound wall in B.B. Masonary in C.M. 1:6 with R.C.C. 620.00 RMT 6658.00
columns at 2.5 m c/c & R.C.C. Beam at G.L. ( Including reinforecement) with 20 mm
thick Cement plaster to all exposed concrete and masonary structure and 0.6 mt high
barbared wire fancing at 2.5 mt c/c on top of compound wall including excavation in all
strata, P.C.C., form work for R.C.C. work, plastering, colour washing and painting to
fencing and clearing the site etc. complete as per the detailed drawing attached.
1) At proposed Fofal Dam site HW-480 Rmt
2) At Ujala SHW of Fofal 1-2 Scheme-140 Rmt
2 Item No.2: Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and 2.00 Set 61973.00
diagonal braces of 40 x 40 x 6 mm angle iron, 3.15 mm M.S. gusset plates at Junctions
and corners 25 mm dia. pulley, 40 x 40 x 6mm angle and T-iron guide rail at top and
bottom respactively with handles, stoppers and locking agangement etc, including
applying a priming coat of red lead paint. and painting two coats (excluding priming
coat) on new steel and other metal surface with synthatic enamel paint, brushing to
give an even shade,including cleaning the surface of all dirt, dust and other foreign
matter.for compound wall of required size & specification as per the drawings with 3 No
of R.C.C. column size 0.45 x 0.45 m ( including reinforcement) with 20 mm thick
cement plaster to all exposed surface including excavation in all strata, P.C.C., form
work for R.C.C. work , painting to all Iron exposed surfaces( incl. brusing , cleaning &
priming coat ) and cleaning the site etc. the site etc. complete as per the detailed
drawing attached.
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B6 Repairing of Existing ESR of 5.0 LL at Ujala SHW
Quantity UNIT Amount
Item Description (only (upto 50 ( Upto
(upto 200 ( Upto
figures) characters) Decimals )
characters) Decimals )
Demolition including stacking of serviceable aterilas and disposal of unserviceable
materials with all lead and lift. (i) R.C.C. work For RCC Spiral Stair case 3.60 Cum 1020.6
2 Item No-2 RCC Spiral Staircase
RCC circular spiral staircase with central circular in M-20 as per design including M.S.
reinforcement, centering, shuttering, form work , scaffolding ,finishing and curing
including providing and fixing balusters of 1.0 m (work below G.L. for column and footing
will be paid extra) for 1m radius and 20 cms rise .For Approx 20 Mt staging ht+5 Mt
container Ht 125.00 Steps 1000
3 Item No-3 D.I. Specials
Manufacture, Supply & Delivery of Ductile Iron Flange socket spigot bends, tees,
reducers or any other specials as per BS-EN-545/1995 Class-A series K12 suitable for
use with D.I. Pipes manufactured as per IS:8329/1994 delivery of specials is to be made
to GWSSB store or site of works any where in Gujarat including all taxes, loading,
unloading, carting, stacking, insurance, inspection charges, octroi etc. complete.Flanged
ended 80 to 300mm dia : 150 MM Duck Foot Bend 27.00 Kg 155
4 Item No-4 DIDF pipes for ESR / Reservoir
Providing and fixing flanged D.I.D.F. / Class K-9 pipes vertically for RCC. Reservoir incl.
providing clamps at every 3 mt incl. jointing materials such as nuts, bolts, rubber
packing, hydraulic testing and necessary scaffolding etc. complete. 150 MM Dia outlet
Pipe 26.00 Rmt 3421
5 Item No-5 M.S. Pipe Railing
Providing an fixing 25 mm x 5.2 mm MS railing with three horizontal rows and posts of
angle iron of size 65 mm x 65 mm x 8 mm RCC 150 mm and 1.15 meter height and
placed at 1.85 mt / c/c including painting two coats and anchorage in CC etc complete At
Roof of ESR 622.00 Kg 77
6 Item No-6 Gunniting exterior surface for Civil Structures only
Gunniting the surface in CM 1:2 having thickness of 40 mm to 50 mm (Ave.) for beam,
braces, column and container slab incl. chiselling and scraping loose concrete cleaning
the surface with water and air under pressure and including providing and fixing in
position steel wires square mesh 75 mm x 75 mm as per IS:1966-1982 3.15 mm
Wt/Sq.Mt. 1.64 Kg. with spot welding wherever necessary with main reinforcement incl.
tying binding with wire incl. scaffolding centering staging all equipment and materials etc.
complete incl. labour and testing of the container. At Outside of ESR Container 248.00 Sqm 594.64
Volume-III, PRICE BID AUG. OF Bhadara RWSS
7 Item No-7 Cement Paint to ESR
Applying any approve quality of cement paint in three coats including cleaning washing
etc. complete for E.S.R. only.
-do- for Existing ESR Incl. Scaffolding At Outside Surface of ESR 688.00 Sqm 79
8 Item No-8 Copper Lightning Arrestor
Providing and fixing copper lightning arrestor incl. copper strip and earthing plate etc.
complete (incl. cost of excavation for earthing plate etc. rate per kgs of copper). For ESR 42.00 Kg 787
9 Item No-9 Water Level Indicator / Depth Gauge
Providing and fixing Water Level Indicator or depth gauge painted on TW plank 25 mm /
MS plate 4 mm thick float, level indicator sliding wire on standard pulleys incl. necessary
arrangement to prevent the swinging etc. complete with calibration up to 5 mt height.For
ESR 1.00 No 5520
10 Item No: 10 Providing and fixing 1mm thick M.S. sheet sliding shutters with frame and
diagonal braces of 40 x 40 x 6 mm angle iron, 3.15 mm M.S. gusset plates at Junctions
and corners 25 mm dia. pulley, 40 x 40 x 6mm angle and T-iron guide rail at top and
bottom respactively with handles, stoppers and locking agangement etc, including
applying a priming coat of red lead paint.For ESR 2.70 Sqm 3652.12
11 Item No.11 Painting letters
Painting letters for "Capacity of tank" the size of letters will be 45 cm height and 50 mm
width. Painting letters 45 Cm Ht. 19.00 No 34
12 Item No: 12 M.S. Ladder(Without safety cage)
Providing and fixing 50 cm wide M.S. Ladder fabricated from M.S. Flats 10 mm x 75 mm
with 20 mm dia steel bar steps in double rows, @ 30 cm C/C. The include stays of
mm x 50 mm flats fixed at 3 meter C/C with welding anchoring and 3 coats anticorrosive
paint. Inside Container of ESR 7.00 Rmt 2950
13 Item No 13 P.C.C. M-10 levelling Course
Providing and casting in situ mass cement concrete in grade M-10 (approx. corresp. to
prop. 1:3:6) using granite quartzite trap metal of size 12 mm to 25 mm incl.consolidation
curing etc. complete.
Without Forms Work 23.00 Cum 3662
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
MECHANICAL SECTION
SCHEDULE-B7.1 to B7.2
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B7.1 Pumping Machinery for Canal Intake Head Work Site
Duty Point : (1) Canal Intake HW : Proposed Canal Intake to proposed Dam site WTP HW - 250M3/Hr, 16 Mtr. Head & 18.5 kW (2 Working +
Stand By) - 04 Sets
Quantity UNIT Rate Amount
Item Description (only (upto 50 ( Upto 2 ( Upto
figures) characters) Decimals Decimals )
(A) MECHANICAL ITEMS:
VERTICAL TURBINE PUMPSET: Supply, installation,Testing &
Commissioning of Vertical Turbine pump motor set of specified duty
parameters & guaranteed efficiency of following MOC with specified capacity
horizontal flange mounted TEFC squirrel cage induction motor, working on
three phase AC supply with 50 Hz ± 3%, 415 V ± 10%, rated speed 1450/1000
RPM along with column and bowl assembly, discharge head, base
channel/RSJ etc. complete as per relevant IS.M.O.C.: Impeller & Sealing
Rings: CF8M, Bowl & Suction Bell: Cast Steel WCB , Shaft with coupling: SS
410, Column Pipe: M.S. Mechanical Seal (above 30kW),ERW, , Base Plate:
MS, Line Bearing: Thordon type, Suction Strainer: S.S.As per detail
specification as per Site Requirements. Minimum Motor rating: 18.5 KW,
Capacity:250 m3/hr, Head:16 mtrs Efficiency: 83% (2W+2S) (Per KW
DPCV: Supply, installation, painting, testing & commissioning of non-slam,
spring action, flanged Dual plate check valve confirming to API 594 & 598 PN
2.0 1.6 with C.I. body, spring steel spring, S.S. seating with all carbon steel 4 NOS 13742.00
hardware’s and other accessories as per data sheet and specification. Size:200
mm NB PN-1.0 Rating -Manually operated (on delivery side)
2.1 Size:400 mm NB PN-1.0 Rating -Manually operated (on header side) 1 NOS 96311.00
EXPANSION BELLOWS:Supply, installation, testing and commissioning of
flanged metallic S.S. expansion bellows confirming to EJMA standard with PN
1.0 rating & all necessary carbon steel hardware’s as per data sheet.
Size: 200 mm NB- (on Delivery Side)
3.1 Size: 400 mm NB- (on Header Side valve and for Flow Meter) 2 NOS 16500.00
BUTTERFLY VALVE:Supply, installation, testing & commissioning of double
flanged Cast iron Butterfly valve on delivery line of pumps as per IS 13095 of of
Volume-III, PRICE BID AUG. OF Bhadara RWSS
PN 1.0 Size: 200 mm NB-Manually operated (on delivery)
4.1 Size: 400 mm NB-Manually operated (on header) 1 NOS 33775.00
AIR VALVE: SITC of CI Tempor proof Flanged double acting kinetic Air Valve
with Isolation Sluice Valve as per IS 14845 PN-1.6 &IS-14846 PN-1.0
respectively with SS304 float, gun metal nozzle, complete hardware's, bolts,
5.0 nuts & washers, gaskets etc. including all taxes, Insurance, Transportation, 1 NO 16758.00
freight charges, Inspection charges, loading, unloading, conveyance to
departmental stores, stacking, security etc. as per IS and Specification. Size:
100 mm NB - PN 1.0 (on Header line outside the Pump house)
M.S. PIPE : Manufacture, Supply & Delivery of Electric Resistance Welded (Up
to 400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled
ends plate or coil conforming to IS-3589-2001 or its latest revision/
ammendment for following thickness outside diameter at GWSSB store or site
anywhere in Gujarat State including all taxes, insurance,transportation, freight
charges, octroi, inspection charges, loading, unloading conveyance to
Departmental stores,stacking etc. all complete.Size: 200 mm NB-6.3 mm thick
(on Delivery side)-As per site requirement
6.1 Size: 400 mm NB-6.3 mm thick (on Header side)-As per site requirement 18 MTR 5306.00
Supply, installation, testing and commissioning of MS fabricated specials with
both side flanges like Blind flange, Elbow, Eccentric/Cocentric tapers, bends, Y
7.0 Joints, Flanges, ductfoot bend, Puddle pipe, Bell mouth, Tee joint, Reducers, 430.00 KG 98.00
Nut-Bolt, Gaskets Etc of required size & in required quantities as per relevant
IS for dilevery & suction line.
E.O.T CRANE: Providing & erecting Single girder type fully electrically
operated E.O.T. crane with electrically operated hoist, class II duty, geared
travelling trolley with seven meter lift complete with long travel rail track (40 mm
sq. bar), moving or cross girder, all three motions electrically operated by
suitable rating motor IP 54, control panel & down pendant control block, brake,
safety device, cables form motor to starter panel & other required accessories
& tested as per IS Specifications. Capacity:2 Ton,span,long traveling and lift as
per site requirement (Span- 9.0Mtr X 12Mtr., Long Travel -12 Mtr., )
PRESSURE GAUGE: Design, Supply, Installation, Testing, Commissioning of
Bourdon Type Pressure Gauge, ±1% accuracy, Direct bottom 1/2" NPT (M)
process connection, IP 67, Glycerine filled, SS304 Case with Bayonet Type
9.0 Bezel, SS316 L Bourdon Tube, SS316 Movement material, Aluminium dial with 5 NOS 1412.00
black graduation on white background, Micro Zero adjustable pointer, neoprene
gasket, Blow out disc, shatter proof glass, SS tag plate etc as per IS 3624. (VT
Pump delivery & header). Range : 0 - 20 kg/sq.cm.and 150 mm dia
Volume-III, PRICE BID AUG. OF Bhadara RWSS
FLOW METER (PN - 1.6): Supply, Installation, Testing, Commissioning of Full
Bore Electromagnetic flow meter with factory calibrated, Regular Power
Operated, flanged connection, Flow sensor, Indicator, transmitter and totaliser
with all accessories viz. surge arrestor, associated cables, cabinets, hardwares,
etc complete as per following specifications:
Flow Meter/ Sensor: DC pulsed type, IP 68 Protection, Flanged process
connection as per IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow
Tube, SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/
Inbuilt Grounding Electrode, Neoprene/ Polyurethane/ Hard Rubber/ Rilsan
lining, SS304/ Die Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil
Housing with Junction Box, CS flanges.
Flow Transmitter/ Converter ( Remote Field Mounted): Microprocessor
based, Modular design, 2 line LCD for indication of actual flow rate, forward,
reverse, sum totaliser display, ±0.5% accuracy at 0.3 to 4 m/sec velocity, 4 to
20 mA with HART/Modbus output, one scalable pulse, one status output, IP
protection, Die cast aluminium/ polycarbonate/ SS316 with Anticorrosive Paint/
PU finish with glass window enclosure, Inbuilt EEPROM and Data Logger,
meters cable length for sensor to transmitter communication etc. alongwith wall
mounted/ stand mounted cabinet.
The Scope also include make cable trench, provide and laying power and
signal cable of type as specified in tender and of required length between
Instrument / transmitter and PLC Panel and double compression weather proof
Ni-Brass cable glands and termination of all applicable cable at instrument side
and panel side. and shall have following size. Meter Size :400 mm (At header)
Providing, erecting, fabricating the MS structure as per requirement on site
incorporating proper size of MS angels, flats, bars, channels, section complete
with cutting, welding, grinding and finishing duly painted with one coat of red
oxide with erection on site as per direction of engineer incharge with necessary
11.0 grouting, cementing, plastering and finishing completed. to prevent the entry of 100.00 Kg. 107.80
birds and proper vantilation in pump house for door.& Window the design and
drawings of the gate shall be approved by the engineer in charge prior to
purchase and manufacturing of the gate. For support of Chequered plate with C-
Section MS Channel.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Breaking, Cutting of Existing Thrust Block / Pump Foundation / Piping and
Removing the Same outside the pump House and Removing the same outside
the pump room and disposing/stacking of material outside pump house as per
instruction of engineer in charge including providing of necessary machinery
equipments for the work. RCC/Brick Retaining Walls, Incerting the Pudder
Pipes, Common Header Pipes Out Side the Pump House breaking Of Existing
motor Pump Foundation Required with breaking cutting tools machinery
acessories and Refilling the Wall Opening by Cement Concrete, Quick Setting
Cement, Water Proofing Chemicals etc. and Making the Water Proof Joints as
per Site Requirement.
Providing & laying reinforced cement concrete in Thrust Block/Pipe/Valves
Supports etc. with tar steel black trap kapchi as coarse aggregate for raft,
grillage footing inclusive providing binding necessary size TMT steel bar with 2 Cu. Mtr. 8566.00
centering form work, with Foam work by adding Tar Steel, bara 50 Kg. CuM
for all duty point.
Supplying & fixing Steel Chequered Plate having 10 mm thickness, duly painted
with two coats of black Japan colour. (Average Wt. 84.6 kg/ Sq.Mtr.) for fabrication of
Ladder and walkway over common header pipe for approaching to pumping
machinaries for operation and maintenance purposes.
Dismentaling and transportation of Pump Motor Set with all valves, Suction,
Delivry header Pipes, Panels, cables, and other misc. acceessories as per
14.0 instruction of Incharge engineer from intake well HW to Rajkot Departmental 1.00 Job 26945.94
store including loading, transporatation,unloading etc including provoding
bracker, gas cutter, labour, hydra crane etc complete.as per Rate analysis
1.0 (B) ELECRICAL ITEMS :
MCCB BOX :Providing and erecting Approved make Four pole moulded case
circuit breaker having breaking capacity ICU of 50 KA. at 415 V. having normal
current rating 200A. with Fixed Microprocessor release suitable to work on
A.C.supply 50 c/s. with all internal connections & complete erected in New
G.M.S. housing. 200 A Cat III
Volume-III, PRICE BID AUG. OF Bhadara RWSS
2.0 LV MCC PANEL BOARD: S.I.T.C of LV MCC Panel totally enclosed, dust & bermin
proof, indoor type, minimum degree of protection - IP 52 as per IS: 2147, operation on
3- Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded, with instrumentation
compartments accomodating LED type indicating lamps, control contactors as per IS:
13947, CT of accuracy class- I as per IS: 2705, relays, meters & control MCBs, air
insulated electrolitic grade Aluminum busbar for three phase & neutral system with
incomming microprocessor based air break fixed type MCCB with trip free mechanism,
current limiting type as per IS: 8828, Motor Contractor (as per type -2 coordination),
Overload Relay with built-in single phasing prevention feature & auxiliary feeders as
per SLD drawings, momentary contact type push buttons, equipment fittings, bus bars,
cable boxes, cable gland, incoming & ougoing cable connection for 1100V grade,
Aluminium/ Copper conductor XLPE/ PVC insulated & PVC sheathed armoured cable,
10% spare terminals, power wiring using 1100V grade, FRLS insulated copper
conductor wires conforming to IS: 694 & 8130, cable compartments/ alleys of minimum
300 mm size, GI earth bus bar for entire length. MCC shall be fabricated from cold 1 Set 147588.35
rolled, coled annealed (CRCA) sheet steel & minimum thickness of various members
shall be as follows: Base Frame/ Channel/ Gland Plate - 3 mm, Load Bearing
Members/ Doors - 2 mm and Internal Partitions - 1.6 mm. complete in all respects as
per SLD, Specification, IS.
1 Nos. 200 A, FP, 35 KA, Microprocessor based MCCB
Out Going Feeder
4 nos. 63A ,TP, 25 KA, MCCB 18.5 KW (2W+2S) Auto Transformer Starter with
MCCB, Contactor, O/L relay, cast resin type CT, Digital MFM, Analogue Ammeter,
SPP, Timer etc.
2 nos 32A MCB TP for Lighting & spare,
1 no. 40A MCB TP for EOT.
10 KVAR X 4 Nos. Panel = 40 KVAR APP Type Capacitor with control MCB rated
for rated for 440 V AC, 3 Phase, 50 Hz as per IS: 13585 Part-1.
3.0 Lighting Distribution Board (LDB) as under: Providing and erecting Sheet
Steel powder coated MCB distribution board - flush / surface mounted fitted
with busbar, neutral link, earth bar and DIN rail, Conforms to IS 8623-1 &
IEC 61439-1 & 3 without MCB to house appropriate nos. of MCBs.(The DBs
should be used of same company of MCB to be used) suitable for Three phase 1 NOS 5769.00
incoming and single phase horizontal type outgoing Per phase isolation type
(PPI) single door 6 way Prewired Lighting Distribution Board Suitable to house :
Incoming: 25A FP, ELMCB (30mA), Cat-III Outgoing: 20A SP MCB (6 nos.),
16A SP MCB (6 nos.)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
4.0 MEDIUM VOLTAGE CABLES: Supply, laying, testing & commissioning 1.1 kV
grade, XLPE insulated, stranded Aluminium conductor, galvanised steel flat
strip / round wire armoured, extruded PVC type ST2 sheathed, heavy duty
cable (to be laid on wall surface with necessary clamps / in existing cable
trench / cable trays / conduit / pipe sleeves at road crossing or floor as per site
requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) of following
sizes:2 Run 3.5 c X 50 Sq.mmAL XLPE Armoured (For Incomer to MCCB
4.1 3 c X 16 Sq.mm AL XLPE Armoured cable (For 18.5 KW Motors) 60 MTR 91.00
4.2 4 c X 4 Sq.mm Cu XLPE Armoured (For EOT, LDB) 50 MTR 141.00
5.0 CABLE END TERMINATION AND CONNECTION : Providing & fitting heavy
duty brass cable glands (nickel-plated) with washers & rubber ring conforming
to IS, suitable for 3, 3½ & 4 core cables of following type & sizes:Double 4 NOS 240.00
Compression Brass Cable Glands 3.5 c X 50 Sq.mmAL XLPE Armoured
((For Incomer to MCCB BOX to Panel).
5.1 3 c X 16 Sq.mm AL XLPE Armoured cable (For 18.5 KW Motors) 8 Nos 154.00
5.2 4 c X 4 Sq.mm Cu XLPE Armoured (For EOT, LDB) 4 NOS 107.00
6.0 CABLE LUGS Providing & fitting crimping type Cable Terminals (Lugs)
conforming to IS of following types and sizes
Aluminium Tubular Terminals (in Sq.mm.) 3.5 c X 50 Sq.mmAL XLPE
Armoured (For Incomer to MCCB BOX to Panel).
6.1 3 c X 16 Sq.mm AL XLPE Armoured cable (For 18.5 KW Motors) 24 Nos 2.00
6.2 4 c X 4 Sq.mm Cu XLPE Armoured (For EOT, LDB) 16 NOS 7.00
7.0 Maintenance free Chemical Earthing: Supplying & erecting earth pit of
minimum bore dia.150mm size approved make Earthing Electrode consisting
Pipe-in-Pipe Technology as per IS 3043-1987 made of corrosion free hot
dipped G.I.Pipes having Outer pipe dia of 50mm having 80-200 Micron
galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by
highly conductive compound with high charge dissipation suitable for following
type of applications with chamber and heavy duty cover.(approved make OEM 2 Nos 4546.00
has to submit test certificate) & having back filling compound of (B) Inner
chemical (CCM Compound)- Resistivity:- 0.2 W/ meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:-
<2%(C) Back fill Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted. For Electrical
installation up to 440V in normal soil. Length of Pipe : 1.00 mtrs Back filling
Compound :1 no. Bag of 15 Kg..(1 Nos. for LT panel, 1 Nos. for Motor)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
7.1 G.I. Earth Strip: Supply, laying and erection of 50mm(w) x 6mm(T) etc. sizes
as required, HOT deep GI Strip including supply & fixing using GI spacers,
saddles when laid inside the building and inclusive of excavation & refilling of
earth when laid outside the building & interconnection with earth pit & all
electro-mechanical equipments. (for panel) (25X6 G.I Strip, 2.4 Kg/m,
8.0 INTERNAL WIRING:- Mains with 1.1kV grade FRLS PVC insulated ISI marked
stranded copper conductor wire in following type of pipe to be erected
concealed in /flushed on wall/ ceiling with 1.5 sq. mm copper conductor FRLS
PVC insulated stranded wire of green colour for earth continuity of following
size.with medium class Rigid PVC pipe and accessories Main wiring with 3 wire
8.1 Supply,Installation,Testing and Commissioning of Main wiring with 3 wire
sq. mm as per tender specification / IS
8.2 Point wiring for Light/ Bell with 2-1.5 sq. mm & earthwire of 1.5 sq.mm (Green)
both are of ISI marked 1.1kV grade FRLS PVC insulated multistrand copper
wires, in following type of pipe to be erected concealed in/ on surface on wall/
ceiling complete with 6A Modular type switch/ bell push & accessories and
earth continuity of following type, erected on PVC/ Metallic box, single 8 NOS 445.00
mounting base frame covered with textured/ metallic front plate modules
erected on/ in wall/ ceiling as per pipe erected, with necessary Lamp holder/
ceiling rose/ H.D.Connector as directed. with medium class Rigid PVC pipe and
accessories-cat.III
8.3 Point wiring for Individual Plug with earthwire of 1.5 sq.mm (Green) both are of
ISI marked 1.1kV grade FRLS PVC insulated multistrand copper wires, in
following type of to be erected concealed in/ on surface of wall/ ceiling
complete with Modular type switch & 5 pin Plug erected on PVC/ Metallic box 2 NOS 471.00
covered with appropriate front plate modules erected on/ in wall/ ceiling as per
pipe erected with following type of accessories.For 6A Plug with 2-1.5 sq.mm
Cu. Wire with medium class Rigid PVC pipe and accessories.
8.4 Point wiring for Individual Plug with earthwire of 1.5 sq.mm (Green) both are of
ISI marked 1.1kV grade FRLS PVC insulated multistrand copper wires, in
following type of to be erected concealed in/ on surface of wall/ ceiling
complete with Modular type switch & 5 pin Plug erected on PVC/ Metallic box 2 NOS 704.00
covered with appropriate front plate modules erected on/ in wall/ ceiling as per
pipe erected with following type of accessories.For 16A Plug with 2-2.5 sq.mm
Cu. Wire with medium class Rigid PVC pipe and accessories.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
9.0 LED LIGHT FIXTURES: Supplying and erecting LED indoor fittings with LEDs
of wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB, with housing
used as a heat sink shall be made of thick sheet Steel conforming to IS:
513/CRCA/ aluminium die cast powder coated and high U.V. & corrosion
resistance with diffuser with company mark/name 120 to 300 V,Power Factor
more than 0.9, THD < 15 %, CCT 3000 K to 6500K, Luminaire efficacy>
lumens/watt ,LED efficiency-110 lumens/watt LED driver efficiency > 85 %
CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/Bridgelux make LED
used for luminaire. ( fitting required LM-79 & LM-80 Certificates) Tube Light
with integral/ nonintegral driver 22-24 Watts, Surge - 2KV,IP-20, 4 feet, Cat-III
9.1 Providing and erecting Approved make Ceiling fan with double ball bearing ISI
mark with condenser A.C. 23OV.50 c/s.1200 mm. sweep complete, canopy
erected on existing hook or clamp with earthing. [Make shall be approved by
Engineer in charge]
9.2 EXTERNAL LIGHTING: Supplying and erecting LED street light / Flood light
fittings with High power White LEDs wattage of 1Watt and above assembled on
single MCPCB, efficiency more than 130 lm/w and corrosion free High pressure
die cast aluminum housing with smooth finish powder coated and heat sink
extruded aluminium with diffuser and Polycarbonate optics/ lenses with
company mark/name engraved or embossed 120 to 300 V,Power Factor more
than 0.95, THD < 10 %, CCT 3000 K to 5700K, Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency > 85 %.CREE /
OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/ BridgeLux (U.S.A.) make LED
used for luminaire. ( fittings required LM-79 & LM-80 certificates) Flood Light
(IP-65), Surge -4KV,Light must have 440VAC line supply protection. It should
withstand 48 hours for 440VAC line supply. above 60 to 90 Watts, Cat-III
9.3 BRAKET: B' class galvanised iron pipe 32 mm outside dia 45 cms long duly
welded on 20 cms x 20 cms x 3 mm thick M.S. base plate, erected on wall or
corner for mounting luminaire with necessary hardware materials duly painted.
For wall mounting indoor & Outdoor Flood light Fixtures on wall of Buiding.
10.0 SAFETY ACCESSORIES: Supplying & erecting ABC powder type 'Ceasefire'
type Fire extinguisher as per IS 13849 or 1 Kg capacity with necessary clamp 2 NOS 840.00
for erection on wall. (for 2no. LT Room)
10.1 Supplying stand first AID box with antiseptic cream, medicine for use on
wounds due burn, crepe bandage, gauge bandage, medicated ready to use
bandage (Band-aid) adhesive tape for medicinal user, Scissors, anti-septic 2 NOS 297.00
solution (savlon or similar) etc. (All above contents shall be of standard makes)
(For Pump house / LT Room)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
10.2 Providing printed instruction Chart both in English and Gujarati and duly framed
with front glasses, for treatment of person suffering from electric shock. (1no. 1 NOS 129.00
10.3 Supplying 4 mm rubber matting of following thickness as per IS:15652/IEC
4 Sq.Mtr 1017.00
61111 (for LT Panel)
10.4 Supplying & erecting FIRE bucket round bottom of 9 lit. capacity made out of
24 gauge GI sheet with extra handle at bottom duly painted white inside & red
out side with fire mark filled with dry sand & kept on exsisting stand provided or
hund on wall hook
10.5 Suppying & erecting floor mounting stand for keeping 4 nos of fire buckets
comprising 1500 mm in length & 900 mm height made out of
30mmX30mmX4mm angle iron with cross supports for lags welded with 4 1 Each 933.00
hooks & duly painted with one coat of red lead & two coats of approved
enammeled silver paint
10.6 Supply of pair of rubber Hand gloves suitable for working on 11/22 kV power
10.7 Supplu of Steel Cup board 3 selves - 20 Gauge . Size - 50 X 30 X 18 as per
Instruction of Engineer Incharge.
10.8 Supply of Steel Table 3 Door -18 Gauge. Size-48 X 24 X 30 as per Instruction
of Engineer Incharge.
10.9 Supply of Steel Perforated Chair powdercoated -16 Gauge. Standard size as
per Instruction of Engineer Incharge.
10.1 Providing and erecting metallic vitrified danger notice board as per language
suggested by engineer incharge for MEDIUM VOLTAGE installation to be 4.00 Each 80.00
erected as per IS-2551.
10.1 Providing & Erecting 3mm thick Polycarbonate (PC) sheet for Painting and
lettering of Name of RWSS, Name of H.W./S.H.W., Pump type, Discharge,
Head, KW/HP,No. of pump set. Year of installation etc. as per instruction of 2000.00 Sq. Inch 3.00
Engineer In-charge on pvc display board of various size as per Sq. Inch. , and
Fixing of the same on wall with necessary fixture. Size- 24' x 18' / 12' x 12'
10.1 Supplying & erecting approved make Digital time switch having lithium cell
years operative and operate battery backup 1 channel day clock with
memory programme, suitable to operate on 240V +5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD display. Also 1 Each 3137.00
comprise dpermanent ON/OFF switching. Programming switches & housed in
fire proof thermoplastic enclosure & transparent cover erected as required with
necessary connection erected as directed.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B7.2 Pumping Machinery for Dam site WTP Head Work
Duty Point : (1) Fofal Dam HW to Ext HGLR near Mota Bhadra - 12 LPS, 88 Mtr. Head & 22 kW (2 Working + 2 Stand By) - 04 Sets
(2) Fofal Dam HW to Ext ESR near Dudhivadar - 14 LPS, 60 Mtr. Head & 18.5 kW (2 Working + 2 Stand By) - 04 Sets
(3) Fofal Dam HW to Ext Sump at Kapeldhar HW of Fofal-1-2 - 56 LPS, 74 Mtr. Head & 75 kW (2 Working + 2 Stand By) - 04 Sets
(4) Fofal Dam HW to connecting point of Ext pipeline of Lunivav village- SM Cat, 440 LPM, 52 Mtr. Head & 15 HP (1 W +1 SB)- 2 Sets
Head Work : Fofal Proposed HW
Quantity UNIT Rate Amount
Item Description (only (upto 50 ( Upto 2 ( Upto
figures) characters) Decimals Decimals )
(A) MECHANICAL EQUIPMENTS SECTION
Supply, installation, testing & commissioning of Horizontal Split Casing Centrifugal
Pump / Horizontal Multistage Pump Motor set of specified duty parameters &
guaranteed efficiency of following MOC with specified capacity, horizontal foot mounted
TEFC squirrel cage induction motor (with minimum IE-3 efficiency class), working on
three phase AC supply with 50 Hz ± 3%, 415 V ± 10%, rated speed 1450 RPM along
with fabricated MS base frame, coupling, coupling guard, foundation bolts etc. as per
M.O.C.: Impeller & Wearing Rings: CF8M, Casing: Cast Steel WCB , Shaft: SS
Shaft Sleeve: SS 410, Mechanical Seal (Above 30 kW), Base Frame: MS.
Duty Parameter: 12 LPS, 88 Mtr. Head & 22 kW, Min. Efficiency: 58%, Pump kW
(12x88/102/0.58= 17.84 KW x 1.15 Margin = 20.52 kW - Next Manu. Range Selected
- 22 kW) (Fofan Dam HW to Ext HGLR near Mota Bhadra)
Duty Parameter: 14 LPS, 60 Mtr. Head & 18.5 kW, Min. Efficiency: 60%, Pump kW
1.2 (14x60/102/0.6= 13.72 KW x 1.2 Margin = 16.47 kW - Next Manu. Range Selected - 4 Set 174933.00
18.5 kW) - (Fofan Dam HW to Ext ESR near Dudhivadar)
Duty Parameter: 56 LPS, 74 Mtr. Head & 75 kW, Min. Efficiency: 75%, Pump kW
1.3 (56x74/102/0.75= 54.16 KW x 1.15 Margin = 62.29 kW - Next Manu. Range Selected 4 Set 627950.00
- 75 kW) - (Fofan Dam HW to Ext Sump at Kapeldhar HW of Fofal-1-2)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Monoset sub. pump 3 phase 400/440 vott, 50 c/s. A.C. Supply & 2900 RPM , as per
MOC : Casing: CI-FG260, Impeller : Bronze & Shaft : SS:41 & Lowering of openwell
1.4 Horizontal Submersible pump sets/bore well pump sets in Well/Sump with HDPE 2 No. 26143.00
pipe/GI/MS column pipe by means of chain pulley block/fixture & jointing the cable with
fuse unit / Control panel board including fitting accessories & making it in working
condition including satisfactory testing. SM - (440 LPM x 52 Mtr x 15 HP) (1 W + 1 S)
M.S. PIPE :Manufacture, Supply & Delivery of Electric Resistance Welded (Up to
400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled ends plate
or coil conforming to IS-3589-2001 or its latest revision/ ammendment for following
thickness outside diameter at GWSSB store or site anywhere in Gujarat State including
all taxes, insurance,transportation, freight charges, octroi, inspection charges, loading, 54 Mtr 980.66
unloading conveyance to Departmental stores,stacking etc. all complete. Size: 100 mm
NB-4.0 mm thick (on Suction side and Delivery Side - Fofan Dam HW to Ext HGLR
near Mota Bhadra and Fofan Dam HW to Ext ESR near Dudhivadar section , fofal
WTP to Lunagara)-As per site requirement
……Do……..Size: 200 mm NB-4.0 mm thick (on Header side - Fofan Dam HW to
Ext HGLR near Mota Bhadra and Fofan Dam HW to Ext ESR near Dudhivadar
section And on Suction side and Delivery Side Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)-As per site requirement
Size: 400 mm NB-6.3 mm thick (on Header side Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2 )-As per site requirement 36 Mtr 5306.00
Size: 600 mm NB-6.3 mm thick (on Common Suction Header side )-As per site
Size: 250 mm NB-5.0 mm thick (on Sump to Common Suction Header side for
Mota Bhadra and Dudhivadar HW )-As per site requirement 8 Mtr 2884.00
Size: 500 mm NB-6.3 mm thick (on Sump to Common Suction Header side for for
Kapeldhar HW )-As per site requirement 4 Mtr 6637.00
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Supply, installation, testing and commissioning of MS fabricated specials with both side
flanges like Blind flange, Elbow, Eccentric/Cocentric tapers, bends, Y Joints, Flanges,
ductfoot bend, Tee joint, Reducers, Nut-Bolt, Gaskets Etc of required size & in required
quantities as per relevant IS for dilevery, common header & suction line.
1. Suction Side: 100 mm dia., Delivery Side: 100 mm dia. & Header Side: 200 mm
dia. - (Fofan Dam HW to Ext HGLR near Mota Bhadra)
2. Suction Side: 100 mm dia., Delivery Side: 100 mm dia. & Header Side: 200 mm
dia. - (Fofan Dam HW to Ext ESR near Dudhivadar)
3. Suction Side: 200 mm dia., Delivery Side: 200 mm dia. & Header Side: 400 mm
dia. - (Fofan Dam HW to Ext Sump at Kapeldhar HW of Fofal-1-2) And
4. Common Suction Pipe - 600 mm dia.
5. Individual Suction Pipe - 500 mm / 250 mm dia.
6. By-pass Pipe - 80 mm / 100 mm dia.
Supply, installation, testing & commissioning of double flanged cast iron 100 mm Dia.
Butterfly Valve as per IS
PN 1.6 rating to be installed on Delivery Side Pipe as per specifications. - (Fofan Dam
HW to Ext HGLR near Mota Bhadra)
Size: 200 mm Dia. PN - 1.6 - Header Side - (Fofan Dam HW to Ext HGLR near Mota
Size: 100 mm Dia. PN - 1.6 - Delivery Side - (Fofan Dam HW to Ext ESR near
Size: 200 mm Dia. PN - 1.6 - Header Side - (Fofan Dam HW to Ext ESR near
Size: 200 mm Dia. PN - 1.6 - Delivery Side - (Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)
Size: 400 mm Dia. PN - 1.6 - Header Side - (Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)
Supply, installation, painting, testing & commissioning of non-slam, spring action,
flanged 100 mm Dia. Dual Plate Check Valve confirming to API 594 & 598 with C.I.
body, spring steel spring, S.S. seating with all carbon steel hardware’s and other
accessories as per data sheet and specification. PN 1.6 rating to be installed on
Header Side Pipe as per specifications. - (Fofan Dam HW to Ext HGLR near Mota
Size: 200 mm Dia. PN - 1.6 - Header Side - (Fofan Dam HW to Ext HGLR near Mota
Size: 100 mm Dia. PN - 1.6 - Delivery Side - (Fofan Dam HW to Ext ESR near
4.4 Size: 200 mm Dia. PN - 1.6 - Header Side - (Fofan Dam HW to Ext ESR near 1 No. 15042.00
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Size: 200 mm Dia. PN - 1.6 - Delivery Side - (Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)
Size: 400 mm Dia. PN - 1.6 - Header Side - (Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)
SITC of ISI marked CI D/F refflux valve as per IS 5312 (Latest Ediation) of PN
Class and 80 mm Dia. Including all taxes insurance transportation, freight
5.1 charges, octroi, inspection charges, loading, unloading, conveyance to 2 No. 4346.00
departmental stores, stacking etc. complete. for Delivery Side of fofal WTP to
Lunagara Section.
Size: 100 mm Dia. PN - 1.0 - Common Delivery Header Side - (Fofan WTP to
Supply at site, storage,Erection, installation, testing & commissioning of ISI mark
mm Dia. CI D/F Sluice Valves PD type short body with hand wheel as per IS:14846
(Latest Edition) of following class and diameter including all taxes, insurance,
6.1 transportation, freight charges, octroi, inspection charges, loading, unloading, 4 Nos. 4037.00
conveyance to departmental stores, stacking etc. complete.PN 1.6 rating to be installed
on Suction Side Pipe as per specifications. - (Fofal Dam HW to Ext HGLR near Mota
Size: 100 mm Dia. CI D/F Sluice Valve - PN - 1.6 - Suction Side - (Fofan Dam HW to
6.2 Ext ESR near Dudhivadar) - 4 Nos. & 100 mm By-pass - 1 Nos. @ 5 Nos. 5 Nos. 4037.00
Size: 100 mm Dia. CI D/F Sluice Valve - PN - 1.0 Common Delivery Header Side -
(Fofal WTP to Lunagara)
Size: 200 mm Dia. CI D/F Sluice Valve - PN - 1.6 - Suction Side - (Fofal Dam HW to
6.3 Ext Sump at Kapeldhar HW of Fofal-1-2) 4 Nos. 11037.00
6.4 Size: 80 mm Dia. CI D/F Sluice Valve - PN - 1.6 - For By-pass Pipe 2 Nos. 3079.00
Size: 80 mm Dia. CI D/F Sluice Valve - PN - 1.0 - Delivery Side - (Fofal WTP to
Supply, installation, testing and commissioning of flanged metallic S.S. 100 mm Dia.
Expansion Bellows confirming to EJMA standard with all necessary carbon steel
hardware’s as per data sheet.
PN 1.6 rating to be installed on Suction Side Pipe as per specifications. - (Fofal Dam
HW to Ext HGLR near Mota Bhadra)
(Parallel Rates of Elec.Mech-GWSSB-SOR 2022-23, Sr. No.: 14.A Page No.: 39)
7.2 Size: 100 mm Dia. PN - 1.6 - Delivery Side - (Fofan Dam HW to Ext HGLR near
Size: 200 mm Dia. PN - 1.6 - Header Side+Flow Meter - (Fofan Dam HW to Ext
HGLR near Mota Bhadra)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
7.4 Size: 100 mm Dia. PN - 1.6 - Suction Side - (Fofan Dam HW to Ext ESR near
Size: 100 mm Dia. PN - 1.6 - Delivery Side - (Fofan Dam HW to Ext ESR near
7.6 Size: 200 mm Dia. PN - 1.6 - Header Side+Flow Meter - (Fofan Dam HW to Ext ESR
near Dudhivadar)
Size: 200 mm Dia. PN - 1.6 - Suction Side - (Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)
7.8 Size: 200 mm Dia. PN - 1.6 - Delivery Side - (Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)
Size: 400 mm Dia. PN - 1.0 - Header Side+Flow Meter - (Fofan Dam HW to Ext
7.9 Sump at Kapeldhar HW of Fofal-1-2) 2 No. 17640.00
SITC of CI 50 mm Dia. Tempor Proof Flanged Air Valve with Isolation Sluice Valve
as per IS 14845 respectively with SS304 float, gun metal nozzle, complete hardware's,
bolts, nuts & washers, gaskets etc. including all taxes, Insurance, Transportation, freight
8.1 charges, Inspection charges, loading, unloading, conveyance to departmental stores, 1 No. 12766.00
stacking, security etc. as per IS and Specification. PN 1.6 rating to be installed on
Header line outside the Pump house as per specifications. - (Fofan Dam HW to Ext
HGLR near Mota Bhadra)
8.2 Size : 50 mm Dia., PN 1.6 rating (Fofan Dam HW to Ext ESR near Dudhivadar) 1 No. 12766.00
8.3 Size : 50 mm Dia., PN 1.0 rating (Fofan WTP to Lunagara) 1 No. 11600.00
Size : 100 mm Dia., PN 1.6 rating (Fofan Dam HW to Ext Sump at Kapeldhar HW of
Supply, installation, testing & commissioning single girder type fully electrically
operated EOT crane with electrically operated hoist, class II duty, geared travelling
trolley with seven meter lift complete with long travel rail track (40 mm sq. bar), moving
9.1 or cross girder, all three motions electrically operated by suitable rating motor IP 54, 1 No. 506250.00
control panel & down pendant control block, brake, safety device, cables form motor to
starter panel & other required accessories & tested as per IS Specifications. Range:
m - 12 m, Lift: 6 - 10 Meter, Long Travel = 12 meter Capacity: 3 TON
Design, Supply at site, storage, installation, testing & commissioning of Bourdon type
glycerin filled pressure gauge, +/- 1% accuracy, direct bottom 1/2" NPT(M) process
connection, IP 67, SS 304 case with Bayonet type Bazel, SS 316 L Bourdon Tube, SS
316 movement material, Aluminium dial with black gradution on white background,
10.0 micro zero adjustable pointer, neoprene gasket, blow out disk, shatter proof glass, SS 18 No. 1412.00
tag plate ets as per IS 3624 complete with siphon tube with isolating cock having range
of 0 to 20 Kg/cm2 (1.5 times rated head) 150 mm Ø dial - (Fofan Dam HW to Ext
HGLR near Mota Bhadra) , (Fofan Dam HW to Ext ESR near Dudhivadar) & (Fofan
Dam HW to Ext Sump at Kapeldhar HW of Fofal-1-2), (Fofal WTP to Lunagara)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Supply, Installation, Testing, Commissioning of Full Bore Electromagnetic flow meter
with factory calibrated, Regular Power Operated, flanged connection, Flow
sensorIndicator, transmitter and totaliser with all accessories viz. surge arrestor,
associated cables, cabinets, hardwares, etc complete as per following
specifications:Flow Meter/ Sensor:DC pulsed type, IP 68 Protection, Flanged process
connection as per IS 1538 or equivalent standard, SS304/ Metallic Alloy Flow Tube,
SS316/ SS 316 L/ Hastelloy Sensor, SS316/ Hastelloy Grounding Ring/ Inbuilt
Grounding Electrode, Neoprene/ Polyurethane/ Hard Rubber/ Rilsan lining, SS304/ Die
11.0 Cast Aluminium/ Carbon steel with Anticorrosive Paint Coil Housing with Junction Box, 1 No. 116653.90
CS flanges.Flow Transmitter/ Converter ( Remote Field Mounted):Microprocessor
based, Modular design, 2 line LCD for indication of actual flow rate, forward, reverse,
sum totaliser display, ±0.5% accuracy at 0.3 to 4 m/sec velocity, 4 to 20 mA with
HART/Modbus output, IP 67 protection, Die cast aluminium/ polycarbonate/ SS316 with
Anticorrosive Paint/ PU finish with glass window enclosure, Inbuilt EEPROM and Data
Logger, 30 meters cable length for sensor to transmitter communication etc.alongwith
wall mounted/ stand mounted cabinet.Meter Size: 200 mm PN - 1.6 - Header Side -
(Fofan Dam HW to Ext HGLR near Mota Bhadra)
Meter Size: 200 mm PN - 1.6 - Header Side - (Fofan Dam HW to Ext ESR near
Meter Size: 400 mm PN - 1.6 - Header Side - (Fofan Dam HW to Ext Sump at
Kapeldhar HW of Fofal-1-2)
Providing & laying reinforced cement concrete in Thrust Block/Pipe/Valves Supports
etc. with tar steel black trap kapchi as coarse aggregate for raft, grillage footing inclusive
12.0 providing binding necessary size TMT steel bar with centering form work, consolidating 20 Cu. Mtr. 8566.40
as per directive in 1:2:4 ratio. with Foam work by adding Tar Steel, bara 50 Kg. CuM
for all duty point.
13.0 Providing, erecting, fabricating the MS structure as per requirement on site incorporating
proper size of MS angels, flats, bars, channels, section complete with cutting, welding,
grinding and finishing duly painted with one coat of red oxide with erection on site as
per direction of engineer incharge with necessary grouting, cementing, plastering and 250.00 Kg. 107.80
finishing completed. to prevent the entry of birds and proper vantilation in pump house
for door.& Window the design and drawings of the gate shall be approved by the
engineer in charge prior to purchase and manufacturing of the gate.
14.0 Excavation for pipe line trenches for water supply, sewerage line, manhole etc. all with
shoring and struting if required as per required gradient and line including safety
provisions using site rails and stacking excavated stuff including up to all required lead
cleaning the site etc. complete for all lifts and strata as specified.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Breaking, Cutting of Existing Thrust Block / Pump Foundation / Piping and Removing
the Same outside the pump House and Removing the same outside the pump room and
disposing/stacking of material outside pump house as per instruction of engineer in
charge including providing of necessary machinery equipments for the work. RCC/Brick
15.0 Retaining Walls, Incerting the Pudder Pipes, Common Header Pipes Out Side the Pump 5 Job 2460.00
House breaking Of Existing motor Pump Foundation Required with breaking cutting
tools machinery acessories and Refilling the Wall Opening by Cement Concrete, Quick
Setting Cement, Water Proofing Chemicals etc. and Making the Water Proof Joints as
per Site Requirement.
Vacumm Pump: Providing, Supplying, Erecting approved make coupled Vacumm
Pump Set (1W+1S) 7.5 HP with horizontal foot mounted TEFC squirrel cage motor
having under mentioned capacity working on three phase 50Hz , 415 V + 10% with base
16.0 plate, DOL starter, cable , GI medium duty suction pipes-10 mtr. long, specials, valves,
PVC tank of 250 litres capacity etc. complete.
MOC:Impeller-SS CF8M, Casing-CI FG260, Shaft-SS
18.0 Providing and supplying water hammer control device ISI mark Class 15 of 250 mm
dia. with cast iron body including all taxes, insurance, transportation,freight
charges,octroi,inspection charges, loading,unloading,conveyance to departmental
stores,stacking etc.Complete.
Zero Velocity valve with Bypass Arrangement upto 300 mm Dia. with CI Body Class
200 MM Dia for proposed WTP to Mota Bhadara Section - 1 Nos & proposed
WTP to Dudhivadar ESR - 1 Nos. @ 2 Nos.
19.0 Providing and supplying water hammer control device ISI mark Class 15 of 250 mm
dia. with cast iron body including all taxes, insurance, transportation,freight
charges,octroi,inspection charges, loading,unloading,conveyance to departmental
stores,stacking etc.Complete. 1.00 No 126335.00
Zero Velocity valve with Bypass Arrangement upto 300 mm Dia. with MS Body Class
400 MM Dia Rating for Pipardi to Gundasari HGLR - 1 Nos.
Providing and erecting Portable Diesel driven self priming Horizontal mono pump
set (Dewatering Set) with four wheel trolley, GI medium duty delivery pipes, Specials,
20.0 Suction Strainer etc. Complete set 12-30 LPS ,6-12 Mtrs Head, MOC: Impeller-
Bronze, Casing- C.I, Shaft-Carbon Steel
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Drain Pump / Dewatering Pump : Supply of horizontal mono submersible pump set
(Drain Pump) as per IS:14220/ 1994 & its latest ammendments of flow rate of 10 M3/
Hr @ 10 meters head with suitable submersible motor as per IS: 9283 / 1994 & its
21.0 latest ammendments working on with minimum with suitable submersible motor working 2 No. 15840.00
on 3 phase, 415 + - 10%, 50 + - 3% Hz power supply ,rated speed 2900 RPM of
following duty capacity, Material of Construction : Impeller- High TEnsile Brass / LTB II,
Casing: CI FG 260 , Pump & motor Shaft: SS 304; Bearing Bush - LTB complete.
(B) ELECTRICAL EQUIPMENTS SECTION
11 kV Two Pole Structure Assembly: SITC of 11 kV double pole 9 mtr. high structure made of
6" X 3" 'I" section girder, 4" X 2" channels, clamps, nuts, bolts, stay wires including earthing
system with following accessories duly connected with ACSR conductors as per approved
drawing & in compliance with requirement of IEC.
(a) 11 kV, 200 A drop out fuses with Synthetic Resin Bonded Paper (SRBP) tubes: 1 Set (01
piece per phase).
(b) 11 kV, 400 A G.O.D. switch complete with earth switch, insulators, operating handle with
galvanised pipe, square bar: 1 Set.
(c) 11 kV lightning arrestor with clamps: 3 Nos.
(d) 11 kV Disc Insulators (70KN): 3 Nos.
(e) 11 kV Pin Insulators (5KN): 3 Nos.
(f) 20 mm dia. GI. Stay Sets Complete: 2 Set.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
HT INDOOR Switch Gear Panel:Supply, installation, testing & commissioning both side
extensible, Indoor type HV Switchgear panel confirming to IS-3427, IS-2516 (Part-I & II.sec.1 ) &
IEC-60056 & IEC-62271-100/200 for use on 3phase, 50 Hz, unearthed AC supply system and
having breaking/ ruptuing capacity of 500 MVA (26.3 kA for 3sec) complete with spring charged
mechanism, ON-OFF mechanical push button, operation counters, Breaker TNC switch, Breaker
L/R switch, necessary auxiliary switches, closing coil, shunt trip, protection relays & Indicators
etc., complete.The panel shall comprise of air insulated busbars provided with heat shrinkable
PVC sleeves. The VCB trolley shall comprise of three vacuum interrupters with epoxy support
insulators and self aligning finger type isolating contacts and necessary mechanical interlocks,
safety shutters, isolating plugs. Enclosure shall be openable from front as well as rear end.The
breaker shall be Manual cum motorised mechanism with following accessories.a) 96 x 96 mm
square flush mounting type Ammeter & Volt meter with selector switchesb) Multi function meterc)
2.0 Double core, cast resin type current transofrmer having ratio as per requirement, one core for 1 Nos. 994714.00
metering & one core for protection having required class of accuracy.d) Instantaneous under
voltage relay & Temperature rise tripping Relay,e) Triple pole IDMTL two over current and one
earth fault relay with current setting range 50-200% and 10-40%f) Electrical closing. coil & shunt
trip coil operating on 110 V DC.g) Auxiliary relay for anti pumping device. h) Three limb, drawout
type, feeder connected, cast resin insulated, three phase Potential transformer having ratio &
burden as per reqirement & Class 0.5 accuracy.i) Annunciator Windows, Common Hooter /
Alarm bell operating on 230 AC/ 110 V DCj) Cable boxes suitable to terminate 3 core XLPE
cable of required size (As per design).k) 230V A.C. to 110 V D.C.power pack for closing &
tripping circuit common.l) Breaker ON-OFF, Auto trip and spring charged indicators.m) Phase
indicating & panel illumination lamps with plug socket. n) Space Heater with Thermostat. -
Comprising of 800 A Vacuum circuit breaker for 1no. Incomer, 2no. O / G feeders for 11/0.433kV
distribution transformers
H.T. XLPE CABLES:Supply, laying, testing & commissioning 11 / 11 kV (UE) grade, XLPE
insulated, stranded Aluminium conductor, galvanised steel flat strip/ round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary
3.0 clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as 100 MTR 1445.00
per site requirement) conforming to IS:7098 (Part-2) & IEC:60502(Part-2), of following sizes:
3 core x 300 sq.mm, XLPE (UE) cable including all accessories,supports etc. as per relevant IS
and tender Specifications
Cable Terminations / Jointing Kits for 11 kV (UE) grade XLPE Cable: Supply & connection of
4.0 the Heat shrinkable type indoor H.T.cable end terminations Kit suitable for 11 KV, 3c x 300 4 NOS 6985.00
sq.mm.XLPE (UE) armoured cable along with Cable Glands.
Cable Terminations / Jointing Kits for 11 kV (UE) grade XLPE Cable: Supply & connection of
4.1 the Heat shrinkable type Outdoor H.T.cable end terminations Kit suitable for 11 KV, 3c x 300 1 NOS 11487.00
sq.mm.XLPE (UE) armoured cable along with Cable Glands.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
DISTRIBUTION TRANSFORMER:SITC of outdoor type, three phase, oil immerged, distribution
transformer of required KVA & voltage ratio, copper double wound, vector group - Dyn11, HV
delta connected & LV star connected with neutral brought out connected to provide separate
earthing terminals, bushing / cable box on HV side and cable box on LV side suitable for cables
or bus duct as per requirement with standard fittings, conforming to IS: 1180 (Part-1) / 2014 with
its latest amendment including first fill of transformer oil & following accessories.(a) Oil
conservator with filling holes with cap and prismatic oil level gauge. (b) Silica Gel dehydrating
breather charged with silica gel (c) Oil drain cum sampling valve with plug (d) Oil filter valve (e)
Lifting Eyes / Hooks / Lugs (f) Two earthing terminal (g) Diagram and rating plate (h) Air release
plug (i) Explosion vent with diaphragm (j) Thermometer pocket (k) Four bi-directional plain roller
5.0 with base channel with hauling holes (l) Fixed / Separate type radiator banks (m) Off circuit 2 NOS 981864.00
externally operated tapping switch (For rating < 1000 kVA) (n) 100 mm stem type oil temperature
indicator (For rating < 500 kVA) (o) Bucholtz relay with shut off valve (For rating ≥ 500 KVA) (p)
150 mm dial type oil temperature indicator with Alarm / Trip contact (For rating ≥ 500 kVA) (q)
150 mm dial type winding temperature indicator with Alarm / Tip contact (For rating ≥ 1000 kVA)
(r) Marshalling box (For rating ≥ 500 kVA) (s) 150 mm dia. magnetic type oil gauge (For rating ≥
1600 kVA) (t) Inspection cover & Jacking lugs (For rating ≥ 1600 kVA) For transformer having oil
storage capacity for 2000 liters and higher, nitrogen injection fire protection system (NIFPS) is to
be provided. -With off circuit tap changer ± 10% in steps of 2.5%(11 / 0.433) kv, minimum
500 KVA plinth mounted ONAN outdoor type step-down transformer having Energy
Efficiency Level :-
Casting of transformer plinth / foundation including oil soak pit (where required) in situ reinforced
cement concrete in M 20 using granite, quartzite trap metal of size 6 mm to 20 mm for RCC work
including providing of 53 grade cement & Fe 415 grade TMT bars, scaffolding, centering, form
work, curing, etc. complete.
RCC plinth / foundation for transformer of capacity:- 500 KVA.
Plinth Dimensions (L x W x H) = (1500x1500x1500)
Chain Link Fencing (For DP Structure & Transformer Yard):
Providing and fixing 2 meter high fencing with 2.0 meter long M.S angle posts 40 mm x
40 mm x 6 mm and oil painting three coats, fixed at 2.50 meter C/C with five horizontal
7.0 lines and two diagonals of galvanised stell barbed wire weighing 9.38 Kg / 100 Rmt, 80.00 Rmt 386.00
strained and fixed to posts with G.I staples, including fixing the posts in ground with
meter x 0.50 meter x 0.50 meter block in C.C 1:5:10 etc. complete including laying of
gravels of suitable size in switchyard.
M.S. Gate (For DP Structure & Transformer Yard):
Providing and fixing M.S. gate made from M.S. angles, channels and flats including all
labour and material cost with painting and fixing at site of work including carting,
loading, unloading etc. complete with M.S. Gate 1 Mtr. x 2 Mtr. in structural steel
Volume-III, PRICE BID AUG. OF Bhadara RWSS
LV POWER CONTROL CENTER (PCC)SITC of 800 A LV POWER CONTROL
CENTER (PCC) SITC of LV Distribution Board (LVDB) totally enclosed, dust & vermin
proof, indoor type, fabricated from CRCA sheet steel with minimum thickness of 3 mm
for base frame/ channel/ gland plates, 2.0 mm for load bearing members/ doors &
mm for internal partitions, minimum degree of protection - IP 52 as per IS:
suitable for operation on 3-Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded,
with instrumentation compartments accomodating meters, aux / protective relays, LED
type indicating lamps & control MCBs as per IS: 13947, current & voltage transformers
as per IS: 2705, air insulated electrolitic grade Aluminum/ Copper busbar for three
phase & neutral system, GI earth bus for entire length, power/ control wiring using
1100V grade, FRLS insulated copper conductor wires conforming to IS: 694 &
equipment fittings, horizontally running busbar compartment height of minimum
mm, incoming & ougoing cable connections for 1100V grade, Aluminium/ Copper
conductor XLPE/ PVC insulated & PVC sheathed armoured cable. LVDB shall have
required incomming/ buscoupler/ outgoing modules of following type & ratings.(1)
Nos. of 800 A, 3 & 4 Pole, ACB (Draw-out Type) with Microprocessor release (O / C, S /
C & E / F) having breaking capacity Icu of 50 kA at 415V with 6NO+6NC potential feee
8.0 auxiliary contacts, secondary isolating contacts with all necessary Electro Mechanical 1.00 No 845746.00
protections & interlocks etc. ACB module shall have enclosure dimension: 2000 (H) x
800 (W) x 1000 (D) & following technical features. 4 pole, MDO with Microprocessor
Release (02 Nos. for Incomer 1 & Incomer 2 + 01 No. for Bus Coupler) Summation CT
shall be provided in Both Incomer for APFC Panel.
Outgoing feeders :- (1) 400 Amp. - 1 No (For 75 KW pump- Proposed WTP to
Kapeldhar HW) (2) 160 Amp. - 1 No (For 18.5 KW pump- Proposed WTP to Dudhivadar
ESR) (3) 160 Amp. - 1 No (For 22 KW pump- Proposed WTP to Mota Bhadra HGLR) (4)
400 Amp. - 1 No for APFCR panel(5) 250 Amp.- 1 No For Proposed WTP(6) 63 Amp -
4 No ( 2 No. For Fofal WTP to Lunagara, 1 No. Feeder for EOT & 1 No. Feeder for
Lighting Load) 4 Pole MCCB with Breaking Capacity of Icu=50 KA at 415V (Ics = 100%
of Icu), Microprocessor release - conforms to IS/ IEC 60947-2 with trip free mechanism,
current limiting type with Microprocessor release (O / C, S / C & E / F) with adjustable
settings & having minimum 2NO+2NC potential free auxiliary contacts with all necessary
Electro-Mechanical protections & interlocks etc. MCCB module, when used as
Outgoing(s), shall have enclosure dimensions - Minimum 600 (D) 3P and 2P MCB shall
be provided for spare (3) No Load Compansation KVAR banks (APP type) 25 kVAR -
Nos. for approx. 5% kVAR of 500 kVA Transformer etc. for both incomer Complete.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
MCC Panel with Microprocessor based soft Starter: 75 KW (1 Incomer and
Outgoing Feeder) Proposed WTP to Kapeldhar HW. Supply, installation, testing &
commissioning of . of LV MCC panel totally enclosed type as per IS : 2147, operation
on three phase,4 wire, 50Hz, neutral effectively grounded, IP 52, with instrument
compartments accomodating LED type indicating lamps, control contactors as per IS:
13947, CT of accuracy class I as per IS :2705, relays & control fuses, Air insulated Al
busbars for three phase & neutral system with Air circuit breakers, air break draw out
type MCCB with trip free mechanism, current limiting type MCB as per IS :
Digital type metering instruments - Smart Load Manager, momentary contact type push
buttons, equipment fittings, busbars, cable boxes, cable glands, incoming & outgoing
cable connection for sutable V grade, Al / Cu conductor PVC insulated & PVC sheathed,
armoured cable, 10% spare terminals, power wiring use of suitable V grade, FRLS
insulated copper conductor wires confirming to IS : 694 & 8130, Cable compartments of
minimum 300 mm size, GI earth busbar for entire length. with moisture sensor, thermal
over load protection, suitable KVAR APP type fixed capacitor bank for each outgoing
feeder with MCC shall be fabricated from cold rolled , coled base frame /channel /
Galnd This item also includes APP type suitable rating fixed capacitor bank for each
outgoing feeders. Indcluding hours meter. Encloser size Minimum 600 mm Depth
required (Height - 2175 mm)75 KW(1 Incomer and 4 Outgoing Feeder)
Microprocessor based Soft Starter with External by pass contactor, Semiconductor
Fuses, Harmonic Filters, cast resin type CT, Digital MFM, Analog Ammeter &
minimum 10 Channel Temperature Scanner with RS 485 communication port.-
No. Incomer and 03 Nos. of outgoing feeders suitable to 75 kW motor rating with
GI earth busbar for entire length of incomer
Volume-III, PRICE BID AUG. OF Bhadara RWSS
MCC Panel with ATS: 22 KW (1 Incomer and 4 Outgoing Feeder) Proposed WTP to Mota
Bhadara HGLR.SITC of LV MCC Panel totally enclosed, dust & bermin proof, indoor type,
minimum degree of protection - IP 52 as per IS: 2147, operationon 3-Phase, 4 Wire, 415V, 50Hz,
Neutral effectively grounded, with instrumentation compartments accomodating LED type
indicatinglamps, control contactors as per IS: 13947, CT of accuracy class- I as per IS:
relays, meters & control MCBs, air insulatedelectrolitic grade Aluminum bus bar for three phase
& neutral system with incomming breaker- microprocessor based Air CircuitBreakers
(electrically operated drawout type)/ air break fixed type MCCB with trip free mechanism,
current limiting type as per IS: 8828,Motor Contractor (as per type -2 coordination), Overload
Relay with built-in single phasing prevention feature & auxiliary feeders as perSLD drawings,
9.2 momentary contact type push buttons, equipment fittings, bus bars, cable boxes, cable gland, 1.0 Set 132517.00
incoming & ougoing cableconnection for 1100V grade, Aluminium/ Copper conductor XLPE /
PVC insulated & PVC sheathed armoured cable, 10% spare terminals,power wiring using 1100V
grade, FRLS insulated copper conductor wires conforming to IS: 694 & 8130, cable
compartments / alleys ofminimum 300 mm size, GI / Al earth bus bar for entire length. MCC
shall be fabricated from cold rolled, coled annealed (CRCA) sheetsteel & minimum thickness of
various members shall be as follows:Base Frame / Channel / Gland Plate: 3 mm, Load Bearing
Members / Doors: 2 mm and Internal Partitions: 1.6 mm.Encloser size Minimum 600 mm Depth
required (Height - 2175 mm)22 KWAuto Transformer Starter with MCCB, Contactor, O/L
relay, cast resin type CT, Digital MFM, Analogue Ammeter, SPP, Timer etc. (1 Incomer
and 4 Outgoing Feeder)For Soft strater(22 KW (3W+2SB)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
MCC Panel with ATS: 18.5 KW (1 Incomer and 4 Outgoing Feeder) Proposed WTP
to Dudhivadar ESR.SITC of LV MCC Panel totally enclosed, dust & bermin proof,
indoor type, minimum degree of protection - IP 52 as per IS: 2147, operationon 3-
Phase, 4 Wire, 415V, 50Hz, Neutral effectively grounded, with instrumentation
compartments accomodating LED type indicatinglamps, control contactors as per IS:
13947, CT of accuracy class- I as per IS: 2705, relays, meters & control MCBs, air
insulatedelectrolitic grade Aluminum bus bar for three phase & neutral system with
incomming breaker- microprocessor based Air CircuitBreakers (electrically operated
drawout type)/ air break fixed type MCCB with trip free mechanism, current limiting type
as per IS: 8828,Motor Contractor (as per type -2 coordination), Overload Relay with
built-in single phasing prevention feature & auxiliary feeders as perSLD drawings,
momentary contact type push buttons, equipment fittings, bus bars, cable boxes, cable
9.3 gland, incoming & ougoing cableconnection for 1100V grade, Aluminium/ Copper 1.0 Set 111434.75
conductor XLPE / PVC insulated & PVC sheathed armoured cable, 10% spare
terminals,power wiring using 1100V grade, FRLS insulated copper conductor wires
conforming to IS: 694 & 8130, cable compartments / alleys ofminimum 300 mm size, GI
/ Al earth bus bar for entire length. MCC shall be fabricated from cold rolled, coled
annealed (CRCA) sheetsteel & minimum thickness of various members shall be as
follows:Base Frame / Channel / Gland Plate: 3 mm, Load Bearing Members / Doors:
mm and Internal Partitions: 1.6 mm.Encloser size Minimum 600 mm Depth required
(Height - 2175 mm)18.5 KW Auto Transformer Starter with MCCB, Contactor, O/L
relay, cast resin type CT, Digital MFM, Analogue Ammeter, SPP, Timer etc. (1
Incomer and 4 Outgoing Feeder)For Soft strater(22 KW (3W+2SB) i.e. 1,59,209.00 -
Cubical Control Panel SITC of DOL/ Star delta Starter suitable for local & remote pump control
application consisting of MCCB/MPCB overload relay and contactors as per Type II coordination
10.1 including digital MFM with RS485 comunication port, analogue ammeter with selector switch, 2.0 No. 12230.90
run hour meter, required protective relays & control accessories. up to SD From11 to 15 HP as
per Detiled tech specification.(Fofal WTP to Lunagara)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
APFCR panel: 130 KVAR: APFC panel consisting following items.
Supply, installaton, testing & commissioning LV APFC panel consisting of required capacitor
banks for continuous duty to improve P.F 0.85 to 0.99 in required steps enclosed in dust &
vermin proof compartment, indoor type, fabricated from CRCA sheet steel with minimum
thickness of 3 mm for base frame / channel / gland plates, 2.0 mm for load bearing members /
doors & 1.6 mm for internal partitions, minimum degree of protection - IP 42, busbar chamber,
required size of Al bus bar / terminals, minimum 10 stage APFC relay, metering, indicating
lamps, push buttons complete as per IS: 16636-2017 with latest ammendment & detailed
technical specification and data sheet as under.
a) 400 A, 50 kA for 1sec. TP, TM based MCCB with spreader terminals & rotary handle b) 0-400
A range analogue ammeter of 96 x 96 mm size with selector switch c) 3nos. 400 / 5A, 10 VA CL-
1.0 cast resin type current transformer d) Suitable rating of MCCB / MCB & Contractors for each
capacitor bank e) Suitable rating APP type capacitor banks (vacuum impregnated with non-PCB
/ non toxic oil, internally delta connected with built in internal fuses complete with discharge
resistances & terminal cover) of approved make in required steps with well suited detuned
reactor is placed in series with each capacitor step. (e.g. 130 KVAR capacity will be provided in
steps of 2 nos x 5 KVAR, 2 nos x 15KVAR, 1 nos x 30 KVAR & 1 nos x 50 KVAR) f) Enclosure
dimensions: 2100 (H) x 1250 (W) x 600 (D)
Lighting Distribution Board (LDB) as under: Providing and erecting Sheet Steel powder
coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth bar
and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house appropriate
nos. of MCBs.(The DBs should be used of same company of MCB to be used) suitable for Three
phase incoming and single phase horizontal type outgoing Per phase isolation type (PPI) single
door 6 way Prewired Lighting Distribution Board Suitable to house :
Incoming: 25A FP, ELMCB (30mA), Cat-III Outgoing: 20A SP MCB (6 nos.), 16A SP MCB (6
Power Distribution Board (PDB) as under:
Providing and erecting Sheet Steel powder coated Vertical MCB distribution board (VTPN) - flush
/ surface mounted double door (IP54) fitted with copper insulated busbar, isolated neutral bar,
earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3, suitable for 63 AMP TPN
MCCB + RCCB as incomer and three phase outgoing as per following .(The DBs should be
used of same company of MCB to be used)
6 way outgoing , Power Distribution Board for Auxiliary accessories load power supply (For EOT
crane, Exaust fan, Welding recaptical & Sapre etc).
Incoming: 63A FP, MCB 'C' Curve Cat.iii
Outgoing: 8 nos. 32A FP MCB 'C' Curve Cat.iii
MEDIUM VOLTAGE CABLES: Supply, laying, testing & commissioning 1.1 kV grade, XLPE
insulated, stranded Aluminium conductor, galvanised steel flat strip / round wire armoured,
extruded PVC type ST2 sheathed, heavy duty cable (to be laid on wall surface with necessary
clamps / in existing cable trench / cable trays / conduit / pipe sleeves at road crossing or floor as
per site requirement) conforming to IS:7098 (Part-1) & IEC:60502 (Part-1) of following sizes:3
RUN 3.5 c x 240 sq.mm. AL XLPE Armoured (Transformer to MVDB panel)
2 Run 3.5 c x 150 sq.mm. AL XLPE Armoured (MVDB panel to 75 KW Panel) & 2 Run for
Volume-III, PRICE BID AUG. OF Bhadara RWSS
15.2 3.5 c x 50 sq.mm. AL XLPE Armoured (MVDB panel to 22 KW Panel & 18.5 KW) 50 MTR 211.00
15.3 3 c X 16 Sq.mm AL XLPE Armoured (For 22 KW /18.5 KW motors) 200 MTR 91.00
15.4 3 c X 95 Sq.mm AL XLPE Armoured (For 75 KW motors) 100 MTR 299.00
15.5 3 c X 10 Sq.mm AL XLPE Armoured (For 11 KW motors) PCC to Cubical Control Panel 20 MTR 86.00
15.6 4 C x 6 sq.mm. Cu XLPE (For LDB, PBD, EOT,etc.) 100 MTR 195.00
3 C x 2.5 Sq.mm CU XLPE Armoured (For TPN MCB at PMCC room & Pump house
maintenance floor, flow meter etc.)
PVC insulated flat / round submersible copper cables
PVC Insulated Flat Copper Submersible Cable for HMSM Pump as per detaild Technical
15.8 specification. Of R/C of GWSSB Confirming to IS 694 IEC 60227 / 60228 Size:- 1x 3 Core x 6 100 mtr 120.00
Sq.mm. comp with reqd. accessories. (Cubical Control panel To HMSM Pump- 11-15 HP
CABLE TRAY: Supply & laying GI perforated type cable trays with returned edge/
flange, fabricated from 2.0 mm thk sheet steel in the standard length of 2.5 mtrs, duly
hot dipped galvanized after fabrication as per IS 2629-1989 / IS 4759-1984 including
16.0 accessories such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers 60 MTR 251.00
and electro-galvanized hardware etc, erected on existing support as per specification
and instruction of engineer in charge.
150(W) x 50(H) x 2.0 mm Thick
Supply & laying GI perforated type cable trays with returned edge / flange, fabricated
from 2.0 mm thk sheet steel in the standard length of 2.5 mtrs, duly hot dipped
galvanized after fabrication as per IS 2629-1989 / IS 4759-1984 including accessories
such as coupler plates/ fish plates, bends, tees, reducers, elbows, covers and electro-
galvanized hardware etc, erected on existing support as per specification and instruction
of Engineer-in-charge. 300(W) x 50(H) x 2.0 mm Thick
Cable Trench, Laying & Installation of Cable: Making trench in soft soil of suitable
18.0 width of 90 cms deep for laying cable or locating the fault all over the run and backfilling 100 MTR 55.00
the same and making the surface as normal ground.
Cable Covering in Trench: Covering of cable with second class bricks or cement tiles
laid cover the cable crosswise & also on both sides with covering of 7. 5 Cms. layer of
sand above & below cable (16 bricks per meter) as per IS & Specification. (For HT & LT
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Maintenance free Chemical Earthing: Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per IS
3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm having
80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron galvanising,
connection terminal dia of 12mm with constant ohmic value surrounded by highly conductive
compound with high charge dissipation suitable for following type of applications with chamber
20.0 and heavy duty cover.(approved make OEM has to submit test certificate) & having back filling 7 Nos 5703.00
compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 W/ meter testing as per IEC
62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar content:- <2%(C) Back fill
Compound :- Earthing compound should be capable to retain moisture for long time Necessary
test report must be submitted.For Electrical installation up to 11 KV in normal soil. Length of Pipe
: 2.00 mtrs Back filling Compound :1 no. Bag of 25 Kg..(for 2 nos. for transformer body, 2 nos. for
transformer neutarl, 1 nos. for LT panel & APFC Panel , 1 nos. for HT panel, 1 nos. for Motor )
G.I. Earth Strip: Supply, laying and erection of 50mm(w) x 6mm(T) etc. sizes as required, HOT
deep GI Strip including supply & fixing using GI spacers, saddles when laid inside the building
20.1 and inclusive of excavation & refilling of earth when laid outside the building & interconnection 448.00 KG 77.00
with earth pit & all electro-mechanical equipments.as per detail specification. (25X6 G.I Strip,
Supply, laying and erection of 50mm(w) x 6mm(T) etc. sizes Copper Strip including supply &
fixing of bolts, saddles when laid inside the building and inclusive of excavation & refilling of earth
21.0 when laid outside the building & interconnection with earth pit & Tr. neutral. as per detail 67 Kg 787.00
(50X6 Cu. Strip, 2.68 Kg/m, 2.68 x 25Mt.=67Kg.)
INTERNAL WIRING:- Providing and erecting Mains with 1.1 KV grade FRLS PVC insulated ISI
marked stranded Copper conductor wire in following type of pipe to be erected concealed in
22.0 /flushed on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated stranded wire of 100 MTR 82.00
green colour for earth continuity of following size with medium class Rigid PVC pipe and
accessories Main wiring with 3 wire 1.5 Sq.mm
Supply,Installation,Testing and Commissioning of Main wiring with 3 wire 2.5 sq. mm as per
tender specification / IS
Point wiring for Light / Bell with 2-1.5 sq.mm & earth wire of 1.5 sq.mm (Green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length , in
below type of pipe erected with 6A Modular type switch / bell push & accessories and earth
continuity of following type, erected on PVC / Metallic/Wooden box, single mounting base frame
covered with textured/metallic/white front plate modules erected on / in wall / ceiling as per pipe
erected, with necessary Lamp holder/ceiling rose / H.D.Connector as directed.
(a) with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete.
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Point wiring for Individual Plug with & earth wire of 1.5 sq.mm (Green) both are of ISI marked
1.1 KV grade FRLS PVC insulated multi strand copper wires up to 10 mtr length, in below type of
pipe erected complete with Modular type switch & 5 pin Plug erected on PVC / Metallic/Wooden
22.3 box covered with appropriate front plate modules erected on / in wall / ceiling as per pipe erected 4 NOS 471.00
with following type of accessories.
For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board
with medium class Rigid PVC pipe and accessories erected flushed on wall/ceiling complete
Point wiring for Individual Plug with earthwire of 1.5 sq.mm (Green) both are of ISI marked 1.1kV
grade FRLS PVC insulated multistrand copper wires, in following type of to be erected concealed
in/ on surface of wall/ ceiling complete with Modular type switch & 5 pin Plug erected on PVC/
22.4 Metallic box covered with appropriate front plate modules erected on/ in wall/ ceiling as per pipe 4 NOS 704.00
erected with following type of accessories. For 16A Plug and 16 amp switch with 2-2.5 sq.mm
Cu. Wire from mcb db board. with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete
LED LIGHT FIXTURES: Supplying and erecting LED indoor fittings with LEDs of wattage
Watt to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink shall be made
of thick sheet Steel conforming to IS: 513/CRCA/ aluminium die cast powder coated and high
U.V. & corrosion resistance with diffuser with company mark/name 120 to 300 V,Power Factor
23.0 more than 0.9, THD < 10 %, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED 10 NOS 751.00
efficiency-110 lumens/watt LED driver efficiency > 85 % CREE / OSRAM / PHILIPS Lumileds /
NICHIA / SEOUL/Bridgelux make LED used for luminaire. ( fitting required LM-79 & LM-80
Certificates) Tube Light with integral/ nonintegral driver 22-24 Watts, Surge - 2KV,IP-20, 4 feet,
Providing and erecting Approved make 1200mm sweep ceiling fan, capacitor type, having double
ball bearing 450mm down rod, canopies, shackle, rubber bush, blades, electronic speed
regulator, suitable to operate on 230V,50Hz AC supply conforming to IS: 374/1979.Fan shall be
painted with white colour.
EXTERNAL LIGHTING: Supplying and erecting LED street light / Flood light fittings with High
power White LEDs wattage of 1Watt and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast aluminum housing with smooth finish
powder coated and heat sink extruded aluminium with diffuser and Polycarbonate optics/ lenses
with company mark/name engraved or embossed 120 to 300 V,Power Factor more than 0.95,
THD < 10 %, CCT 3000 K to 5700K, Uniformity ratio >0.45, Luminaire efficacy> 100 lumens/watt
. LED driver efficiency > 85 %.CREE / OSRAM / PHILIPS Lumileds / NICHIA / SEOUL/
BridgeLux (U.S.A.) make LED used for luminaire. ( fittings required LM-79 & LM-80 certificates)
Flood Light (IP-65), Surge -4KV,Light must have 440VAC line supply protection. It should
withstand 48 hours for 440VAC line supply. above 60 to 90 Watts, Cat-III
BRAKET: Supplying and erecting B class galvanised iron pipe 32 mm outside dia 45 cm long
23.3 duly welded on 20 cm x 20 cm x 3 mm thick M.S. base plate, erected on wall or corner for 6 NOS 340.00
mounting street light luminaire with necessary hardware materials duly painted.
SAFETY ACCESSORIES: Supplying & erecting ABC powder type 'Ceasefire' type Fire
24.0 extinguisher as per IS 13849 or 1 Kg capacity with necessary clamp for erection on wall. (for 6 NOS 840.00
2no. LT & HT Room)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Supplying stand first AID box with antiseptic cream, medicine for use on wounds due burn, crepe
bandage, gauge bandage, medicated ready to use bandage (Band-aid) adhesive tape for
24.1 medicinal user, Scissors, anti-septic solution (Savlon or similar) etc. (All above contents shall be 2 NOS 297.00
of standard makes) (For Pump house / LT Room)
Providing and fixing printed instruction chart both in English and Gujarati and duly framed with
front glasses, for treatment of person suffering from Electric shock with minimum 50" diagonally
24.2 size.. (1no. For LT Room and 1 no. for HT Room)
Supplying FIRE bucket round bottom of 9 litres capacity made out of 24 gauge G.I. sheet with
extra handle at bottom duly painted white inside and Red out side with FIRE mark, filled with
24.3 dry-sand and kept on existing stand provided or hung on wall hook. ( for HT Panel, Tr.1, Tr.2)
Suppying & erecting floor mounting stand for keeping 4 nos of fire buckets comprising
1500 mm in length & 900 mm height made out of 30mmX30mmX4mm angle iron with
cross supports for lags welded with 4 hooks & duly painted with one coat of red lead &
two coats of approved enammeled silver paint
Supplying 12 mm rubber matting of following thickness as per IS:15652/IEC 61111 (for HT
5 SQ.MTR 3051.00
26.1 Supplying 4 mm rubber matting of following thickness as per IS:15652/IEC 61111 (for LT Panel) 20 SQ.MTR 1017.00
Providing and erecting metallic vitrified danger notice board as per language suggested
27.0 by engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. 4.00 Each 80.00
Providing and erecting metallic vitrified danger notice board as per language suggested
27.1 by engineer incharge for HIGH VOLTAGE installation to be erected as per IS-2551. 2.00 Each 95.00
Providing & Erecting 3mm thick Polycarbonate (PC) sheet for Painting and lettering of
Name of RWSS, Name of H.W./S.H.W., Pump type, Discharge, Head, KW/HP,No. of
pump set. Year of installation etc. as per instruction of Engineer In-charge on pvc
display board of various size as per Sq. Inch. , and Fixing of the same on wall with
necessary fixture. Size- 24' x 18' / 12' x 12'
Supplying & erecting approved make Digital time switch having lithium cell 6 years
operative and operate battery backup 1 channel day clock with 14 memory programme,
suitable to operate on 240V +5%, 16A with, floating contacts Minimum switching setup
29.0 time 1 minimum & LCD display. Also comprise dpermanent ON/OFF switching. 1 Each 3137.00
Programming switches & housed in fire proof thermoplastic enclosure & transparent
cover erected as required with necessary connection erected as directed.
Supplu of Steel Cup board 3 selves - 20 Gauge . Size - 50 X 30 X 18 as per
30.0 Instruction of Engineer Incharge. 1 No 7420.00
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Supply of Steel Table 3 Door -18 Gauge. Size-48 X 24 X 30 as per Instruction of
Engineer Incharge.
Supply of Steel Perforated Chair powdercoated -16 Gauge. Standard size as per
Instruction of Engineer Incharge.
Total of Section ( A+B) Rs.
Executive Engineer Dy. Executive Engineer
P. H. Mechanical Sub Dn No.2,
P. H. Mech DIVISION , Rajkot
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
Schedule:- B7.5 Pumping Machinery for Head Work : Ujala SHW
Duty Point : (1) Ujala SHW : Prop Sump to Ext ESR Section- 19 LPS, 39 Mtr. Head & 15 kW (2 Working + 2 Stand By) - 04 Sets
Quantity UNIT Amount
Item Description (only (upto 50 ( Upto
(upto 200 ( Upto
figures) characters) Decimals )
characters) Decimals )
MECHANICAL PART
1.0 HSCF /MULTISTAGE PUMPSET: Ujala SHW to Ujala ESR: Supply, installation, testing &
commissioning of Horizontal split casing centrifugal pump motor set of specified duty parameter and
guarnateed efficiency of following MOC with specified capacity and withhorizontal foot mounted TEFC
squirrel cage inducion motor ,working on three phase 50 Hz +/- 3%, 415 V +/- 10%, rated speed
RPM alongwith fabricated MS base frame, coupling with guard, foundation bolts etc. complete set as
per relevent IS M.O.C.: CF8M, Casing: Cast steel WCB, Shaft: SS 410, Shaft Sleeve: SS
Mechanical Seal (above 30 kW), Base Frame: MS. etc Complete. DUTY PARAMETERS: - 19 LPS x
Mtr Head, Minimum 15 kW Prime mover 1450 rpm (2W+2S) Minimum Pump Eff. - 65% Pump
KW :- 19 X 39 / 102 / 0.65 = 11.18 KW x 1.20 Margin 13.41 KW Next Manu. Range selected
Kw (Per KW=Rs.9118.00) (15 KWx9118.00) = Rs.
2.0 Drain Pump / Dewatering Pump : Supply of horizontal mono submersible pump set (Drain Pump) as
per IS:14220/ 1994 & its latest ammendments of flow rate of 10 M3/ Hr @ 10 meters head with
suitable submersible motor as per IS: 9283 / 1994 & its latest ammendments working on with minimum
with suitable submersible motor working on 3 phase, 415 + - 10%, 50 + - 3% Hz power supply ,rated
speed 2900 RPM of following duty capacity, Material of Construction : Impeller- High TEnsile Brass /
LTB II, Casing: CI FG 260 , Pump & motor Shaft: SS 304; Bearing Bush - LTB complete.
M.S. PIPE : Manufacture, Supply & Delivery of Electric Resistance Welded (Up to
400mm)/Submerged Arc Welded(Above 400mm) M.S.Pipe having beveled ends plate
or coil conforming to IS-3589-2001 or its latest revision/ ammendment for following
thickness outside diameter at GWSSB store or site anywhere in Gujarat State
including all taxes, insurance,transportation, freight charges, octroi, inspection
charges, loading, unloading conveyance to Departmental stores,stacking etc. all
Size: 150 mm NB-4.5 mm thick (Suction Side )-As per site requirement
Size: 250 mm NB-5.0 mm thick (Header Side )-As per site requirement 18 Mtr 2884.00
Size: 100 mm NB-4.0 mm thick (Delivery side )-As per site requirement 20 MTR 980.66
Volume-III, PRICE BID AUG. OF Bhadara RWSS
SITC of M.S.Specials fabricated from MS pipes/ plates of required thickness
confirming to relevent IS including all taxes, duties, insurance, transformation, freight,
octoroi, inspection, loading, unloading,convey to site, stacking, etc. Complete Up to
4.0 Supply, testing & Commissioning of flange ends Expansion Bellow as per EJMA standards of overall
length of minimum 300 mm , designed for 15 mm axial compression and 5 mm axial extension with tie
rods etc of follwoing MOC and pressure ratings.MOC: Bellows SA 240 Gr 304 ; Internal Sleeve SA 240 4.00 No. 3420.00
Gr 304 ; Weldends : IS 2062 Gr B: ( Drilling as per IS 1538 IS 6392 ) & limit Rods & nuts : CS - IS
1367. Size :-100 MM Dia., PN 1.0 (On Delivery Ujala SHW to Ujala ESR)
4.1 --- do -- 150 MM Dia., PN 1.0 (On Suction Pipe Ujala SHW to Ujala ESR Section.) 4.00 No. 4656.00
4.2 --- do -250 MM Dia., PN 1.0 (On Header Pipe & Flowmeter forUjala SHW to Ujala ESR Section)) 2.00 No. 7745.00
5.0 SITC of CI Dual Plate Check Valve as per API-594/598 with lowering, laying and jointing in position
including cost of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing
etc. complete.on Delivery Pipe Size :- 100 MM Dia., PN 1.0 (On Delivery Pipe of Ujala SHW to
Ujala ESR Section
5.1 - do.. 250 MM Dia., PN 1.0 Rating (On Header Pipe Ujala SHW to Ujala ESR Section) 1.00 No. 25986.00
6.0 SITC of ISI mark Manually Gear Operated CI D/F Butterfly Valves as per IS 13095 (having ISI mark
embossed on the valve) with Sleeve of EPDM and disc., shaft & internal part of SS-410 including all
taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking with lowering, laying and jointing in position including cost
of all labour, jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete.
Size :- 100 MM Dia PN-1.0 Rating Ujala SHW to Ujala ESR Section on Delivery Pipe
6.1 --- do -- 250 MM Dia., PN 1.0 (On Header pipe Ujala SHW to Ujala ESR Section.) 1.00 No. 9509.00
7.0 SITC of ISI mark, Manually Hand Wheel Operated CI D/F Sluice Valves as per IS 14846 with Body,
Dome, Cover - CI, Seat & Face - Bronze, Spindle - SS410, Spinle Nut - Bronze, etc., including all taxes,
insurance, transportation,freight charges, octroi, inspection charges, loading, unloading, conveyance to
departmental stores, stacking with lowering, laying and jointing in position including cost of all labour,
jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. 50 mm Dia.,
PN 1.0 (On Bypass of Header pipeline Section)
7.1 --- do.. -150 MM Dia., PN 1.0 (On Suction of Ujala SHW to Ujala ESR Section) 4.00 No. 6433.00
8.0 Pressure Gauge with Accessories: Design , Supply, installation, testing & commissioning of Bourdon
type pressure gauge ,+-1% accuracy, Direct bottom 1/2" NPT (M) process connection ,IP
Glycerine filled ,SS304 Case with BAyonet Type Bezel,SS316 L Bourdon Tube, SS 316 Movement
material ,Aluminium Dial with black graduation on white background, Micro Zero adustable pointer
neoprene gasket ,Blow out disc ,shatter proof glass, SS tag plate etc as per IS 3624 of 150 mm dial size.
9.0 Single Girder E.O.T. Crane : Providing & erecting Single girder type fully electrically operated E.O.T.
crane with electrically operated hoist, class II duty, geared travelling trolley with seven meter lift
complete with long travel rail track (40 mm sq. bar), moving or cross girder, all three motions electrically
operated by suitable rating motor IP 54, control panel & down pendant control block, brake, safety
device, cables form motor to starter panel & other required accessories & tested as per IS Specifications
(12m long travel, 0 m -6 m span, 6 mt to 10 mt lift ) 1 Ton Capacity
Volume-III, PRICE BID AUG. OF Bhadara RWSS
10.0 SITC of C.I. Temper Proof Air Valve with SS304 float, gun metal nozzle of approved make and
quality of following class and diameter with Manually Hand Wheel Operated CI D/F Sluice Valves with
Body, Dome, Cover - CI, Seat & Face - Bronze, Spindle - SS410, Spinle Nut - Bronze, etc., including all
taxes, insurance, transportation, freight charges, octroi, inspection charges, loading, unloading,
conveyance to departmental stores, stacking, etc. complete.50 MM Dia PN -1.0 Rating for all Three
11.0 Full Bore Electromagnetic Flow Meter - Regular Power Operated : Design, supply, installation,
testing, commissioning of full bore electromegnatic flow meter with factory calibrated regulator power
operated, flanged connection, flow sensor, indicator, tranmittor and totaliser with all accessories viz.
surge arrestor, associated cables, hardwares, etc complete as per following conditions : Flow meter
sensor : DC pulsed type, IP 68 protection, Flanged process connection as per IS 1538 or equivalent
standard, SS304/mettallic alloy flow tube, SS316/ SS 316 L/ Hastelloy sensor, SS316/ Hastelloy
grounding ring/ inbuilt grounding electrode, neprene/ polyurethene/ hard rubber/ rilsen lining, SS304/Die
cast Aluminium/ carbon steel with Anticorrosive paint coil housing with junction box, CS flanged. Flow 1.00 No. 117201.00
transmitter / converter (Remote Field Mounted) : Microprocessor based, Modular design, 2 line LSD for
indication of actual flow rate , forward, reverse, sum totaliser disply, +0.5% accuracy at 0.3 to 4 m/sec
velocity, 4 to 20 ma with HART/ modulas output, one status output, IP 67 protection, die cast
aluminimum/polycarbonate/SS316 with anticorrosive paint/ PU finish with glass window enclosure,
inbuild EEPROM, and data logger, 20 mtrs calbe length for sensor to transmitter communication etc
alongwith wall mounted/ stand mounted cabinet. PN 1.0 For Ujala SHW to Ujala ESR Section--250
12.0 RCC Work : Providing & casting in situ reinforced cement concrete in grade M 20 (Ratio 1:2:4) using
quartzite trap metal of size 6 mm to 12 mm for RCC work, including scaffolding centering, form work,
consolidating, curing etc. inclusive providing and binding necessary size TMT steel bars of Fe 415 grade 10.00 Cum 9180.40
with water proofing compound as per directives for pipe support / thrust blocks.
13.0 Breaking cutting of RCCC brick and retaining wall, incerting the Pudder suction pipes, common header
pipes out side the pump house and refilling wall opening by the cemant concret quick setiing cemant
water proffing chemicals etc. and making the water proof joints asa per site requirement rate for material 2.00 Job 2678.00
L.S. 1000 & for labor = semi skilled 3 labour for one day rs. 487+ 72.20 = 559.20*3 = Rs.1677.60 SAY
14.0 Providing, erecting, fabricating the MS structure as per requirement on site
incorporating proper size of MS angels, flats, bars, channels, section complete with
cutting, welding, grinding and finishing duly painted with one coat of red oxide with
erection on site as per direction of engineer incharge with necessary grouting, 100.00 Kg. 109.36
cementing, plastering and finishing completed. to prevent the entry of birds and proper
vantilation in pump house for door.& Window the design and drawings of the gate shall
be approved by the engineer in charge prior to purchase and manufacturing of the gate.
Providing and erecting Portable Diesel driven self priming Horizontal mono pump
set (Dewatering Set) with four wheel trolley, GI medium duty delivery pipes, Specials,
Suction Strainer etc. Complete set 12-30 LPS ,6-12 Mtrs Head, MOC: Impeller-
Bronze, Casing- C.I, Shaft-Carbon Steel
Volume-III, PRICE BID AUG. OF Bhadara RWSS
ELECTRICAL PART
MCCB with BOXProviding and erecting Approved make Four pole moulded case
circuit breaker having breaking capacity ICU of 50 KA. at 415 V. having normal
current rating up to 200A. with variable Microprocessor release suitable to work 1.00 No. 23788.51
on A.C.supply 50 c/s. with all internal connections spreader tinned copper &
complete erected in New 16 G.M.S. housing. 200 A Cat III
2.0 Supplying and erecting triple pole & neutral 440V/ 500V panel mounting Aluminium
Busbars Suitable For 200 A with four equal Nos. of bus having current density not
more than 0.8 Amp. / sq.mm (Rated current / cross section area) duly wrapped with
colour insulating tape for phase sequence of following current carrying capacity,
erected with necessary bus bar supports /insulators, main cable socket to each
busbar,erected in existing cubical panel with necessary connections.Suitable for 200 A
3.0 SITC of Star Delta starter suitable for local & remote pump control application consisting of MPCB,
overload relay and contactors as per Type II coordination including digital voltmeter, analogue ammeter
with selector switch, run hour meter, required protective relays & control accessories. S.D. from 16 to
4.0 1.1kV Grade Cable- Aluminium Conductor:
Supply, laying, testing & commissioning1.1 kVgrade, XLPE insulated ,stranded Aluminium conductor,
galvansised steel flat strip / round wire Armoured, exruded PVC type ST2 shealthed, heavy duty cable
with Aluminium Conductor conforming to IS 7098 (Part-I) & IEC 60502 / 1988 for 1100 Volts grade of
approved make with glanding and termination with suitable size lugs / bolts & nuts with all required
materials and labour. Cable shall be laid on wall surface with necessary clamps / in existing cable
trench/ CAble trays / conduit / pipe sleeves at road crossing or floor as per site requirement. Size :-
1X3.5X 25 SQ.MM ( GEB Mtr To MCCB to Panel )
4.2 ....Do... 1X3X 10 SQ MM. XLPE Cable For 15 KW Panel To Motor ( Ujala Sump to Ujala ESR
4.3 4 c X 4 Sq.mm Cu XLPE Armoured (For EOT, LDB) 30 mtr 141.00
5.0 Lighting Distribution Board (LDB) as under: Providing and erecting Sheet Steel powder
coated MCB distribution board - flush / surface mounted fitted with busbar, neutral link, earth
bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 & 3 without MCB to house
appropriate nos. of MCBs.(The DBs should be used of same company of MCB to be used)
suitable for Three phase incoming and single phase horizontal type outgoing Per phase isolation 1 NOS 5775.00
type (PPI) single door 6 way Prewired Lighting Distribution Board Suitable to house :
Incoming: 25A FP, ELMCB (30mA), Cat-III
Outgoing: 20A SP MCB (6 nos.), 16A SP MCB (6 nos.)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
6.0 Maintenance free Chemical Earthing: Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode consisting Pipe-in-Pipe Technology as per
IS 3043-1987 made of corrosion free hot dipped G.I.Pipes having Outer pipe dia of 50mm
having 80-200 Micron galvanising, Inner pipe dia of 25 mm having 200-250 Micron
galvanising, connection terminal dia of 12mm with constant ohmic value surrounded by highly
conductive compound with high charge dissipation suitable for following type of applications
with chamber and heavy duty cover.(approved make OEM has to submit test certificate) & 2.0 No. 4546.00
having back filling compound of (B) Inner chemical (CCM Compound)- Resistivity:- 0.2 W/
meter testing as per IEC 62561-2017, Voltage drop:- < 1 volt at no load & dry form, Sulphar
content:- <2%(C) Back fill Compound :- Earthing compound should be capable to retain
moisture for long time Necessary test report must be submitted. For Electrical installation up to
440V in normal soil. Length of Pipe : 1.00 mtrs Back filling Compound :1 no. Bag of 15 Kg..(1
Nos. for LT panel, 1 Nos. for Motor)
6.1 G.I. Earth Strip: Supply, laying and erection of 50mm(w) x 6mm(T) etc. sizes as required,
HOT deep GI Strip including supply & fixing using GI spacers, saddles when laid inside the
building and inclusive of excavation & refilling of earth when laid outside the building & 112 Kgs. 70.00
interconnection with earth pit & all electro-mechanical equipments. (for panel) (25X6 G.I Strip,
7.0 SITC of GI perforated type cable trays with returned edge/ flange, fabricated from 2.0 mm thk 30.00 mtr
sheet steel in the standard length of 2.5 mtrs, duly hot dipped galvanized after fabrication as per
IS 2629-1989 / IS 4759-1984 including accessories such as coupler plates/ fish plates, bends,
tees, reducers, elbows, covers and electro-galvanized hardware etc, erected on existing support
as per specification and instruction of engineer in charge. 150(W)x35(H)x2.0 mm Thick
8.0 Supplying and erecting 12 mm thick rubber mat as per IS 5424 for LT of required length &
breadth with good insuklation propoerty for 22KV. 6.00 Sq. m. 3051.00
Supplying of 12mm rubber matting of following thickness as per IS:15652 /IEC
9.0 Providing and erecting metallic vitrified danger notice board as per language suggested by
engineer incharge for MEDIUM VOLTAGE installation to be erected as per IS-2551. 2.00 Each 69.00
10.0 Providing & erecting Printed instruction chart both in English & Gujarati and duly frame with
front glasses ;for treatment of persion suffering from electric shock. 2.00 Each 129.00
11.0 Supplying stand First Aid Box with antiseptic cream, medicine for use on wounds due burn,
crepe bandage ,gaufe bandage ,medicated ready to use bandage adhesuve tape for medicinal 2.00 Each 297.00
user , Scissors, anti-septic solution tec- all the standard contents.
12.0 Supplying & erecting carbon dioxide (CO2) fire extinguisher user of following capacity with
necessary clamps made from 50 x 6 mm M.S. Flat with nut & bolts grouted in wall complete. 2.00 Each 8586.00
For 6.5 KG Capacity
Volume-III, PRICE BID AUG. OF Bhadara RWSS
13.0 Mains with 1.1kV grade FRLS PVC insulated ISI marked stranded copper conductor wire in
following type of pipe to be erected in/ on wall /ceiling with 2.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green colour for earth continuity of following size. With 30 mtr 111.00
medium class Rigid PVC pipe and accessories a. 2 wire 4 sq.mm (with 2.5 sq.mm earth wire)
14.0 Providing following type of Modular type accessories mounted with PVC/ metallic box, single
mounting base frame covered with textured/ metallic front plate, modules erected with
necessary connection as desired by Engineer In charge 6 Each 267.00
16A single Pole Modular MCB Switch, Cat. II (3 point of 30 Watt, 3 point of 70 Watt,)
15.0 Supplying and erecting LED indoor fittings with LEDs of wattage 0.2 Watt to 0.5 Watt
assemble don single MCPCB, with housing use dasa heat sink shall be made of thick sheet
Steel conforming to IS:513 / CRCA / aluminium pressure die cast powder coated and high U.V.
& corrosion resistance with diffuser house din aluminium casted body with company
mark/name 160 V to 270 V , Power Factor more than 0.95, THD < 15 %,CCT 3000 K to
6500K, Luminaire efficacy> 85 lumens/watt ,LED driver efficiency > 85 %(fitting required LM 6 Each 751.00
- 79 & LM -80 Certificates ) (NOTE: Below description have shown ranges of Wattage
capacity of LED fittings. The Engineer incharge may select any wattage capacity between the
ranges shown.) (A) Square / Circular shaped Surface / Recessed Mount Down light with
provision for spring loaded mounting clips complete.IP20 22-24 Watts, Surge - 2KV,IP-20,
16.0 Supplying and erecting LED streetlight/ Flood light fittings with High power White LEDs
wattage of 3 Watt and above assembled on single MCPCB, efficiency more than 130 lm/w and
corrosion free High pressure die cast aluminium housing with smooth finish powder coated and
heat sink extruded aluminium with diffuserand Polycarbonateoptics/ lenses with company mark
/name engraved or embossed160 to 270 V, Power Factor more than 0.95, THD < 10%, CCT
3000 K to 5700 K, Uniformity ratio > 0.45, Luminaire efficacy > 100 lumens/watt. LED driver 4 Each 3312.00
efficiency > 85%. (fittings required LM - 79 & LM-80 certificates) (NOTE: Below description
have shown ranges of Wattage capacity of LED fittings. The Engineer incharge may select any
wattage capacity between the ranges shown.)(A) Street Light (IP-65), Surge protection - 4 KV
integraland, Light must have 440 VAC line supply with over-voltage protection.36-48 Watts,
Surge - 2KV,IP-20, 4 feet, Cat-III
17.0 Providing and erecting Approved make Ceiling fan with double ball bearing ISI mark with
condenser A.C.23OV.50c/s.1200mm.sweep complete, can opyerected on existing hook or 2 Each 1581.00
clamp with earthing. [Make shall be approved by Engineer in charge]
18.0 Providing & erecting Switch board for Computer or electric apparatus consisting of following
items in single board erected on PVC / Metal/Wooden board concealed/open with 3 mm thick
PC (Polycarbonate) / Acrylic sheet erected as directed 1 no. 6A/16A universal plug-switch
combined. 3 nos. 6A Switch 3 nos. 6A 5 pin Plug
Volume-III, PRICE BID AUG. OF Bhadara RWSS
19.0 Supplu of Steel Cup board 3 selves - 20 Gauge . Size - 50 X 30 X 18 as per
Instruction of Engineer Incharge
58.0 Supply of Steel Table 3 Door -18 Gauge. Size-48 X 24 X 30 as per Instruction of
Engineer Incharge.
20.0 Supply of Steel Perforated Chair powdercoated -16 Gauge. Standard size as per
Instruction of Engineer Incharge 1 No 2160.00
Providing & Erecting 3mm thick Polycarbonate (PC) sheet for Painting and lettering of Name
of RWSS, Name of H.W./S.H.W., Pump type, Discharge, Head, KW/HP,No. of pump set. Year
of installation etc. as per instruction of Engineer In-charge on pvc display board of various size 2000.00 Sq. Inch 3.00
as per Sq. Inch. , and Fixing of the same on wall with necessary fixture. Size- 24' x 18' / 12' x
Supplying & erecting approved make Digital time switch having lithium cell 6 years operative
and operate battery backup 1 channel day clock with 14 memory programme, suitable to
operate on 240V +5%, 16A with, floating contacts Minimum switching setup time 1 minimum
& LCD display. Also comprise dpermanent ON/OFF switching. Programming switches & 1 Each 3137.00
housed in fire proof thermoplastic enclosure & transparent cover erected as required with
necessary connection erected as directed.
Total (A)+(B) - (Rs.)
Executive Engineer Dy. Executive Engineer
P. H. Mechanical Sub Dn No.2,
P. H. Mech DIVISION , Rajkot
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
SCHEDULE C1- COMPREHENSIVE O & M WORK :: PART A
Quantity UNIT Rate Amount
Item Description (only (upto 50 ( Upto 2 ( Upto
figures) characters) Decimals Decimals )
Comprehensive Operation and Maintenance of the project mainly Water Treatment Plant,
different class, type and diameter pipes, pump houses, Sumps, RCC ESR, H.G.L.R, Sluice
valves, Flow meters, Non-return valve, Pump, motor, capacitor, L.T. Panels, L.T. cables and
transformer installed at Headwork and Sub headwork. Work includes replacement of spares for
all equipment and maintenance of all civil structures and all electro-mechanical installation etc.
complete. Including submission of periodic MIS reports on software. Supply of potable water in
accordance, maintaining residual chlorine, and all consumables. All type operations, preventive
maintenance, overhauls and repair/ break down maintenance for civil / mechanical & electrical
works. Providing prescribed nos. of qualified and experienced staff for overall management of
O&M work as per detailed specification & obligatory requirement for 120 months. Excluding
electric power, raw water cost, chlorine, PAC and bleaching powder under Augmentation of
Bhadara Regional water supply schemes & Fofal 1-2 RWSS of Tal.- Jamkandorana,Jetpur,
Dist.- Rajkot as per tender.
Part A: Operation & Maintenance of Civil & Electromechanical assets as per this contract for the
Augmentation of Bhadara Regional water supply scheme + Fofal 1-2 RWSS, including
supply of <Required> MLD potable water to all the hamlets i.e. 12V+(38V+3P) villages for
months period. Taluka: Jamkandorana,Jetpur, Dist.- Rajkot based on Fofal Dam HW
Excluding supply of PAC, bleaching powder and chlorine gas.
1.1 First Year :with effect of 1st year DLP for new All components 12 Month 1254713
1.2 Second Year : with effect of 2nd year DLP for new All components 12 Month 1329996
1.3 Third Year : with effect of 3rd year DLP for new All components 12 Month 1409796
1.4 Forth Year : with effect of 4th year DLP for new Building components 12 Month 1591472
1.5 Fifth Year : 12 Month 1719939
1.6 Sixth Year : 12 Month 1823135
1.7 Seventh Year : 12 Month 1932523
1.8 Eighth Year : 12 Month 2048475
1.9 Ninth year : 12 Month 2171383
1.10 Tenth Year : 12 Month 2301666
Dy. Executive Engineer Executive Engineer
P.H.S.Sub Division P.H.Works Division
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Ribda Group Augumentation Water Supply Scheme
SCHEDULE C2- COMPREHENSIVE O & M WORK :: PART B
Item Description Qty (upto 50 ( Upto
(upto 200 ( Upto
characters) Decimals )
characters) Decimals )
Comprehensive Operation and Maintenance of the project mainly Water Treatment Plant,
different class, type and diameter pipes, pump houses, Sumps, RCC ESR, H.G.L.R,
Sluice valves, Flow meters, Non-return valve, Pump, motor, capacitor, L.T. Panels, L.T.
cables and transformer installed at Headwork and Sub headwork. Work includes
replacement of spares for all equipment and maintenance of all civil structures and all
electro-mechanical installation etc. complete. Including submission of periodic MIS reports
on software. Supply of potable water in accordance, maintaining residual chlorine, and all
consumables. All type operations, preventive maintenance, overhauls and repair/ break
down maintenance for civil / mechanical & electrical works. Providing prescribed nos. of
qualified and experienced staff for overall management of O&M work as per detailed
1.2.0.0 specification & obligatory requirement for 120 months. Excluding electric power, raw water
cost, chlorine, PAC and bleaching powder under Augmentation of Bhadara Regional
water supply schemes & Fofal 1-2 RWSS of Tal.- Jamkandorana,Jetpur, Dist.- Rajkot
Part B : Maintenance activities, measured and paid separately, such as painting, cleaning
of reservoirs/ tanks, procurement and replacement of filter media etc complete as per this
tender document
Payment will be made in proportion to the change in actual quantity measured
against the fixed quantity indicated in the respective items.
1.2.3.1 Forth,Seventh & Tenth Year:PART B1(i):Painting Maintanance: at Mid of 4th year,
End of 7th Year, End of 10th Year of O&M Period
(i) Distempeing-2 Coat :Inside Painting to all Functional civil structures, as per schedule (3
time in the 10 Year period) for WTP-1N+PH-6N in a Lot
1.2.5.1 Forth,Seventh & Tenth Year:PART B1(ii):Painting Maintanance: at Mid of 4th year,
End of 7th Year, End of 10th Year of O&M Period
(ii) Weather proof exterior emulsion paint-2 Coat:Out side Painting to all Functional civil
structures, as per schedule (3 time in the 10 Year period) for WTP-1N+Sumps/HGLR-
13N+ESR-5N+PH-6N+C Wall-7Location in a Lot (3 time in the 10 Year period)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
1.2.3.2 Forth,Seventh & Tenth Year:PART B1(iii):Painting Maintanance: at Mid of 4th year,
End of 7th Year, End of 10th Year of O&M Period
(iii) Enamel paint-3 Coat: Oil paint colour: All type of doors, windows, ventilation, shutter,
pump, motor, all valves & equipment inside pump house, transformer yard, D.P. structure,
transformer etc in a Lot (3 time in the 10 Year period)
1.2.3.3 Forth,Seventh & Tenth Year:PART B1(iii):Painting Maintanance: at Mid of 4th year,
End of 7th Year, End of 10th Year of O&M Period(iv) Epoxy 2 Coats:Food Grade epoxy
coat: Inside of storage reservoir/ tanks for 13 Sump/HGLR +5 ESR ) (3 time in the
1.2.1.1 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=0.20ML(3 NoX20 Cycles) 60 2618.00 No
1.2.1.2 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=0.30ML (2NoX20 Cycles) 40 3414.00 No
1.2.1.3 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=0.50ML(2NoX20 Cycles) 40 5463.00 No
1.2.1.4 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=1.0ML(1NoX20Cycles) 20 9105.00 No
1.2.1.5 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=1.20ML(1NoX20Cycles) 20 10925.00 No
1.2.1.6 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=1.50ML(1NoX20Cycles) 40 13429.00 No
1.2.1.7 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=4.0ML(1NoX20Cycles) 20 34483.00 No
1.2.1.8 First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :Sump/HGLR Capacity=6.0ML(1NoX20Cycles) 20 50757.00 No
First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :ESR Capacity=0.07ML(1NoX20Cycles) 20 2503.00 No
First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :ESR Capacity=0.40ML(1NoX20Cycles) 20 3984.00 No
Volume-III, PRICE BID AUG. OF Bhadara RWSS
First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :ESR Capacity=0.50ML(1NoX20Cycles) 20 4466.00 No
First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :ESR Capacity=0.80ML(1NoX20Cycles) 20 6600.00 No
First Year to Tenth Year : PART B2: Cleaning of Storage (At the ending of 6th &
th Month of each year of O&M Period) every six months (20 times in the 10 Year
period) :ESR Capacity=0.90ML(1NoX20Cycles) 20 7056.00 No
1.2.1.2 First to Tenth Year : PART B3: Filling of filter media (At the ending of 6th & 12 th
Month of Each year of O&M Period) Lost media restoration for WTP (For 13 MLD
WTP:Approx 12M3/Cycle every six months (20 times in the 10 Year period) 240 1277.00 Cum
Executive Engineer
P.H.Works Division
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Taluka- Jamkandorna,Jetpur Dist-Rajkot
SCHEDULE C : COMPREHENSIVE O & M WORK (Civil & Electro Mechanical)
Comprehensive Operation and Maintenance of the project mainly Water Treatment Plant, different class, type and diameter pipes, pump houses, Sumps, RCC ESR,
H.G.L.R, Sluice valves, Flow meters, Non-return valve, Pump, motor, capacitor, L.T. Panels, L.T. cables and transformer installed at Headwork and Sub headwork.
Work includes replacement of spares for all equipment and maintenance of all civil structures and all electro-mechanical installation etc. complete. Including
submission of periodic MIS reports on software. Supply of potable water in accordance, maintaining residual chlorine, and all consumables. All type operations,
preventive maintenance, overhauls and repair/ break down maintenance for civil / mechanical & electrical works. Providing prescribed nos. of qualified and
experienced staff for overall management of O&M work as per detailed specification & obligatory requirement for 120 months. Excluding electric power, raw water
cost, chlorine, PAC and bleaching powder under Augmentation of Bhadara Regional water supply schemes & Fofal 1-2 RWSS of Tal.- Jamkandorana,Jetpur,
Dist.- Rajkot as per tender.
Part A: Operation & Maintenance of Civil & Electromechanical Part B : Maintenance activities, measured and paid
assets as per this contract for the Augmentation of Bhadara separately, such as painting, cleaning of reservoirs/ tanks,
Regional water supply scheme + Fofal 1-2 RWSS, including procurement and replacement of filter media etc complete
supply of <Required> MLD potable water to all the hamlets & as per this tender document
12V+(38V+3P) villages for 120 months period. Taluka:
Jamkandorana,Jetpur, Dist.- Rajkot based on Fofal Dam HW Grand Total
Jamkandorana,Jetpur, Dist.- Rajkot based on Fofal Dam HW Grand Total
Sr. Sequence of Excluding supply of PAC, bleaching powder and chlorine gas.
Rate per Month Amount per Year PartA+PartB
Total Amount For Proposed & Existing Civil-Mech
Total Amount For Proposed & Existing Civil-Mech
UNIT For Proposed & per Year for Amount of Amount of
Month Amount of Amount per
Existing Civil- Part A B2: B3: WTP
B1: Painting year for Part
Mech Cleaning of Sand
Total Cost for 10 Year Total Cost for 10 Year
Dy. Executive Engineer Executive Engineer
P.H.S.Sub Division No-2 P.H.Works Division
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Breakup of Part:A
COST CALCULATION for SCHEDULE C- Part-A : O & M WORK
O&M Cost Allocation/year for proposed & Existing components
O&M Year Inflation Cost of staff Cost for Cost for Cost for O&M of Total Annual Monthly
applied Esttablishment O&M of O&M of Proposed O&M Cost O&M
& Vehicle Existing Proposed Component Cost
Component Component (Building)
1 st Year 12,530,832 DLP DLP
2 Year 13,282,682 DLP DLP
3 rd Year 14,079,643 DLP DLP
4 Year 14,924,421 DLP
Total O&M for 10 years
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Establishments Requirement of Man Power during O&M Period
(For One year) For All components(Proposed & Existing)
Location Wise Nos. of Person requirement
ard Fofal Fofal Bhadra Dudhi Kap Pipar Ujala Cha Cha Gund D- Total
Sr. Asset Canal dam HGLR vadar eldh di SHW rel vand asari Netw
Designation Guidelines Requi
No. data Intak site ESR ar SHW ESR i HGL ork
t (nos) e HW SHW HW SH R Vega
Engineer (5 YoE)
Asst. Maintenance
3 subdivisio subdivis 1 1
Engineer (1 YoE)
4 Operators (1 YoE)
for filter plant and
a 2 per plant Plants: 2 2
for pumping 1 per
station PS/Shift
5 control centre: 0
station + 1 Total
6 Electrician (3 YoE) per PS: 6 + 1 1
category A 1 Cat A
7 1 per lab ory: 1 1 1
Chemist (1 YoE)
Volume-III, PRICE BID AUG. OF Bhadara RWSS
8 inspection, repair
and distribution
Pipe Fitter (0.5 1 per
Valve man (0.5 1 per 10
YoE) villages Village
for filter plant
b 2 per plant Plants: 2 2
d 1 per lab ory: 1 1 1
(sampling testing)
11 Sweeper 20,000 ns of < 2 1 1
sqft area 20000s
Outdoor campus premise
Total manpower 62 5 16 3 2 8 7 6 2 3 1 6
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Break up of Part: B
Name of Work- Design, Build and Operate contract for Augumentation of Bhadara Regional Water Supply Scheme
Calculation of Cost of Part B: for Specific Scheduled Maintanace required for O&M activity (Baseline year-2026)
Part B : For Proposed & Existing Work : Maintenance activities, measured and paid separately, such as painting, cleaning of reservoirs/ tanks, procurement and replacement
of filter media etc complete as per this tender document
Amoun Amoun Amoun Amoun Amoun Amoun Amoun
Amount Amount Amount
t for t for t for t for t for t for t for Total Amount
t for t for t for t for t for t for t for Total Amount
Base for 4th for 7th for 10th
Rate Year Year Year
Sr. Stat Year Year Year Year Year Year Year
Item Qty Unit (in Rs.)
Basic At Rate including 0% yearly inflation
Distempeing-2 Coat:Inside Painting to all Functional civil structures, as per schedule (3 time in the 10 Year period)
WTP- 10-15 MLD Sqm Per
Bha capacity (Inside all Pro No.X1
dra: Surface with pos 1 Time@ 63024 63024 63024 63024
HW Plastic Emulsion ed Rate
paint-3 Coat) Rs.62.4Per
+Ve Pump House- ~750 Sqm
415-435 Sqm Per No.X1
(Inside all Surface Time@
with Plastic Rate
Emulsion paint-3 Rs.62.4Per
VT Pump House- ~370 Sqm
90-110 Sqm Per No.X1
(Inside all Surface Time@
with Plastic Rate
Emulsion paint-3 Rs.62.4Per
+Ve Pump House- ~450 Sqm
140-160 Sqm Per No.X1
(Inside all Surface Exis Time@
with Plastic ting Rate
Emulsion paint-3 Rs.62.4Per
Volume-III, PRICE BID AUG. OF Bhadara RWSS
+Ve Pump House- ~410 Sqm
115-135 Sqm Per No.X1
(Inside all Surface Time@
with Plastic Rate
Emulsion paint-3 Rs.62.4Per
Weather proof exterior emulsion paint-2 Coat:Out side Painting to all Functional civil structures, as per schedule (3 time in the 10 Year period)
capacity (Outside
all Surface with
exterior emulsion
ESR 0.1-0.5ML ~420 Sqm
Capacity (Outside Per No.X1
all surface Exis Time@
Weather proof ting Rate
exterior emulsion Rs.120.93P
paint-2 Coat) er Sqm
ESR 0.5-1.0ML ~710 Sqm
Capacity (Outside Per No.X1
all surface Exis Time@
Weather proof ting Rate
exterior emulsion Rs.120.93P
paint-2 Coat) er Sqm
ESR 0.1-0.5ML ~420 Sqm
Fofa Capacity (Outside Per No.X1
l: all surface Exis Time@
Ujal Weather proof ting Rate
a exterior emulsion Rs.120.93P
paint-2 Coat) er Sqm
Sump 1-2ML ~510 Sqm
Capacity (Outside Per No.X1
all surface Time@
Weather proof Rate
exterior emulsion Rs.120.93P
paint-2 Coat) er Sqm
Sump 4-5ML ~1370
Capacity (Outside Sqm Per
all surface No.X1 .1
Weather proof Time@
Volume-III, PRICE BID AUG. OF Bhadara RWSS
exterior emulsion Rate
paint-2 Coat) Rs.120.93P
(Outside all Pro
surface Weather pos 1 29023.2 29023.2 29023.2
proof exterior ed
emulsion paint-2
dra: Exis Time@
surface Weather 2 58046.4 58046.4 58046.4
emulsion paint-2
nal+ 1MLCapacity
Kap (Outside all
el+ surface Weather 4 116092.8 116092.8 116092.8
Ch.. proof exterior
di+ emulsion paint-2
Fofa 1MLCapacity
l:Ca (Outside all Pro
nal+ surface Weather pos 1 29023.2 29023.2 29023.2
Ujal proof exterior ed
a emulsion paint-2
Sump 1-2ML ~240 Sqm
Capacity (Outside Per No.X1
all surface Exis Time@
Weather proof ting Rate
exterior emulsion Rs.120.93P
paint-2 Coat) er Sqm
Sump 5-6ML ~1610
Capacity (Outside Sqm Per
all surface Exis No.X1
Weather proof ting Time@ .3
exterior emulsion Rate
paint-2 Coat) Rs.120.93P
Volume-III, PRICE BID AUG. OF Bhadara RWSS
+Ve Pump House-
Bha (Outside all Pro
dra: Surface Weather pos 1 84651 84651 84651 84651
HW proof exterior ed
emulsion paint-2
Fofa (Outside all Pro
l:Ca Surface Weather pos 1 41116.2 41116.2 41116.2
nal proof exterior ed
emulsion paint-2
Fofa +Ve Pump House-
l:Ka 140-160 Sqm
pel+ (Outside all
Pipa Surface Weather 3 152371.8 152371.8 152371.8
rdi+ proof exterior
Dne emulsion paint-2
+Ve Pump House-
Fofa (Outside all Pro
l:Uja Surface Weather pos 1 47162.7 47162.7 47162.7
la proof exterior ed
emulsion paint-2
(Inside-Outside all ~4 Sqm
Surface with Per RmtX1
Outside all Time@
Surface Weather Rate
proof exterior Rs.120.93P
emulsion paint-2 er Sqm
Coat)):1 Locations
Volume-III, PRICE BID AUG. OF Bhadara RWSS
l:Ca Compound Wall
nal+ (Inside-Outside all ~4 Sqm
Kap Surface with Per RmtX1
el+ Outside all Exis 107 Time@
Pi.di Surface Weather ting 2 Rate
+Ch proof exterior Rs.120.93P
.di+ emulsion paint-2 er Sqm
Dne Coat)):5 Locations
(Inside-Outside all ~4 Sqm
Surface with Per RmtX1
Outside all Time@
Surface Weather Rate
proof exterior Rs.120.93P
emulsion paint-2 er Sqm
Coat)):1 Locations
B1 Enamel paint-3 Coat: Oil paint colour: All type of doors, windows, ventilation, shutter, pump, motor, all valves & equipment inside pump house, transformer yard, D.P.
(iii) structure, transformer etc (Three time in the 10 Year period)
All installation of
capacity having
Iron/steel like
Bha CLR Bridge Pro
dra: Assembly/All pos 1 17555 17555 17555 17555
HW Machinery/All ed
Arrangement/Door
Letters etc all
All installation of
dra: Iron/steel i.e All
Dud Piping/Railling/Do 1 3511 3511 3511 3511
hiva or/Window/Ventila
indicator/Ladders/
Capacity Letters
Volume-III, PRICE BID AUG. OF Bhadara RWSS
All installation of
1MLwith structural ~30 Sqm
Iron/steel i.e All Per No.X1
Piping/Railling/Do Exis Time@
or/Window/Ventila ting Rate
tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
All installation of
Iron/steel i.e All
Piping/Railling/Do 1 3511 3511 3511 3511
or/Window/Ventila
indicator/Ladders/
Capacity Letters
All installation of
having structural ~20 Sqm
Iron/steel i.e All Per No.X1
Piping/Railling/Do Time@
or/Window/Ventila Rate
tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
All installation of
having structural ~30 Sqm
Iron/steel i.e All Per No.X1
Piping/Railling/Do Time@
or/Window/Ventila Rate
tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
All installation of ~10 Sqm
Sump upto-1ML Pro Per No.X1
having structural pos 1 Time@ 1755.5 1755.5 1755.5 1755.5
Iron/steel i.e All ed Rate
Piping/Railling/Do Rs.175.55P
Volume-III, PRICE BID AUG. OF Bhadara RWSS
or/Window/Ventila er Sqm
indicator/Ladders/
Capacity Letters
All installation of
having structural ~10 Sqm
Bha Iron/steel i.e All Per No.X1
dra: Piping/Railling/Do Exis Time@
HG or/Window/Ventila ting Rate
LR tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
All installation of
having structural ~10 Sqm
Iron/steel i.e All Per No.X1
Piping/Railling/Do Exis Time@
or/Window/Ventila ting Rate
tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
All installation of
having structural ~10 Sqm
Iron/steel i.e All Per No.X1
Piping/Railling/Do Time@
or/Window/Ventila Rate
tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
All installation of
having structural ~20 Sqm
Iron/steel i.e All Per No.X1
Piping/Railling/Do Exis Time@
or/Window/Ventila ting Rate
tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
Volume-III, PRICE BID AUG. OF Bhadara RWSS
All installation of
having structural ~40 Sqm
Iron/steel i.e All Per No.X1
Piping/Railling/Do Exis Time@
or/Window/Ventila ting Rate
tor/WL Rs.175.55P
indicator/Ladders/ er Sqm
Capacity Letters
+Ve Pump House-
having structural
Bha Iron/steel i.e All Pro
dra: Machinery/Piping/ pos 1 8777.5 8777.5 8777.5 8777.5
HW Railling/Door/Win ed
dow/Ventilator/La
Letters etc all
having structural
Fofa Iron/steel i.e All Pro
l:Ca Machinery/Piping/ pos 1 5266.5 5266.5 5266.5 5266.5
nal Railling/Door/Win ed
dow/Ventilator/La
Letters etc all
+Ve Pump House-
Fofa 140-160 Sqm
l:Ka having structural
pel+ Iron/steel i.e All
Pipa Machinery/Piping/ 3 5266.5 15799.5 15799.5 15799.5
rdi+ Railling/Door/Win
Dne dow/Ventilator/La
Letters etc all
+Ve Pump House-
having structural
Fofa Iron/steel i.e All Pro
l:Uja Machinery/Piping/ pos 1 5266.5 5266.5 5266.5 5266.5
la Railling/Door/Win ed
dow/Ventilator/La
Letters etc all
Volume-III, PRICE BID AUG. OF Bhadara RWSS
having structural
Iron/steel i.e All
Bha Machinery/Piping/ Pro
dra: Railling/Door/ pos 1 3511 3511 3511 3511
Letters etc all
having structural
Iron/steel i.e All
Machinery/Piping/
Railling/Door/ 5 3511 17555 17555 17555
Pi.di ting Rate
Letters etc all
having structural
Iron/steel i.e All
Fofa Machinery/Piping/ Pro
l:Uja Railling/Door/ pos 1 3511 3511 3511 3511
Letters etc all
Epoxy 2 Coats:Food Grade epoxy coat: Inside of storage reservoir/ tanks as per schedule. (Three time in the 10 Year period)
Bha ESR 0.1-0.5 ML
dra: Capacity (Inside
Dud container wall 1 21340 21340 21340 21340
hiva surface with
dar epoxy -2 coat
l:Pip ESR 0.5-1 ML
ardi Capacity (Inside
+Ch container wall 3 39770 119310 119310 119310
rel+ surface with
Ch.. epoxy -2 coat
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Capacity (Inside
container wall 1 21340 21340 21340 21340
Fofa Capacity (Inside Pro
l:Ca container wall pos 1 69840 69840 69840 69840
nal surface with ed
Sump 4-5 ML Sqm Per
Bha Capacity (Inside Pro No.X1
dra: container wall pos 1 Time@ 162960 162960 162960 162960
HW surface with ed Rate
epoxy -2 coat Rs.97Per
Capacity (Inside Pro
container wall pos 1 33950 33950 33950 33950
surface with ed
Capacity (Inside
dra: Exis Time@
container wall 2 33950 67900 67900 67900
nal+ Sump upto-1 ML
Kap Capacity (Inside
el+ container wall 4 33950 135800 135800 135800
Ch.. surface with
di+ epoxy -2 coat
Fofa Sump upto-1 ML ~350 Sqm
l:Ca Capacity (Inside Pro Per No.X1
nal+ container wall pos 1 Time@ 33950 33950 33950 33950
Ujal surface with ed Rate
a epoxy -2 coat Rs.97Per
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Fofa Sump 1-2 ML
l:Ka Capacity (Inside
pel+ container wall 2 69840 139680 139680 139680
Pipa surface with
rdi epoxy -2 coat
Fofa Sump 5-6 ML Sqm Per
l:D- Capacity (Inside No.X1
Net container wall 1 Time@ 193030 193030 193030 193030
Veg surface with Rate
di epoxy -2 coat Rs.97Per
B2 Cleaning of Storage reservoir: UG sumps, ESR, HGLR/ GLCC and all village level sumps every six months (20 times in the 10 Year period)
dra: Exis Year@
dra: Exis Year@
Volume-III, PRICE BID AUG. OF Bhadara RWSS
l:Gu Exis Year@
Fofa 2 Time Per
Volume-III, PRICE BID AUG. OF Bhadara RWSS
l:Ch Exis Year@
Procurement & replacement of filter media: Effective size of filter sand 0.45 to 0.70 mm, uniformity coefficient not more than 1.7 nor less than 1.3, depth of filter 0.75 M,
B3 freeboard 50 cm, gravel 0.45 M in depth, sand and gravel conforming to IS: 8491 (i) – 77. (every six months)
WTP- 13 MLD 24Cum/2
capacity (Sand Pro Cycle in
per Cycle of 6 ed Rate
Months Rs.1277Per
Volume-III, PRICE BID AUG. OF Bhadara RWSS
Dy. Executive Engineer EXECUTIVE ENGINEER
P.H.S.Sub Division P. H. WORKS DIVISION
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
02 VOL 1 B GCC-Bhadra-R2.1(SD Clause Revised).pdf
03 VOL II A and D Extent of Work and DATA SHEET CIVIL-Bhadara_R2.1.pdf
04 VOL II B I TECH SPECI. CIVIL-Bhadara_R2.1.pdf
05 VOL II B II TECH. SPECIFIC. WTP-Bhadara_R2.1.pdf
06 Vol_IIC-1 Tech Spec and Data sheet Mech.-Bhadara_R2.1.pdf
07 Vol_IIC-2 Tech Spec and Data sheet Electrical -Bhadara_R2.1.pdf
08 Vol IV Comprehensive O and M Specification _Bhadara_R2.1.pdf
09 VOL III Price Bid-Bhadara-R2.1.pdf
10 DRG-1 Scheme layout_R2 (Combined).pdf
10 DRG-1 Scheme layout_R2.1 (Combined).pdf
11 DRG-3 GA DRG-Compound Wall.pdf
12 DRG-2 GA OF AIR VENT RISER.pdf
1. Ann shramyogi GR (1).pdf
2. Annexture 1.pdf
3. Annexture 5 Insurance.pdf
4. Badhakam Shramyogi-1.pdf
5. Chlorination.pdf
6. Hard Rock Circular 05.10.20.pdf
7. Hard rock Circular 26.12.18.pdf
8. Laghutam Vetan Paripatra Dtd 01.04.24.pdf
9. Letter for nCode Mobile App (1).pdf
10. Price variation and M and R Clause Change.pdf
11. Price Variation Paripatra 2023.pdf
12. Royalty 1.pdf
13. ROYALTY 2.pdf
14. SD EMD GR 25-26.pdf
15. SIGN BOARD-1.pdf
16. Vigilance Insurance Dt 19 03 12 GR.pdf
17. works contract with O and M.pdf
18. Annexture 4 Unbalance Rate.pdf
19. Badhakam Shramyogi.pdf
20. Circular GST 07-01-22.pdf
21. Circular of GST 10.7.17.pdf
22. Unbalance rate.pdf
22.1 Annexture 4 Unbalance Rate.pdf
23. standard bid small change in GCC clause no.1 Dt.3-5-2025.pdf
24. Correction in Technical bid clause Dt.28-8-2025.pdf
01 VOL IA Technical Bid-Bhadara_R2.1.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .