Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.7 LAccepted-AOC 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹32.7 L Quoted ₹34.0 L | L1 | Accepted-AOC The lowest and reasonable bidder |
| 2 | L2₹36.2 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹36.2 L | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹38.2 LRejected-Finance | ₹38.2 L | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹38.9 LRejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | ₹38.9 L | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹39.6 LRejected-Finance 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | ₹39.6 L | L5 | Rejected-Finance Not the lowest bidder |
| Sl No | Description | Qty | Unit | Sukhi Electricals L3 | JAYESH TRADING CORPORATION L2 | M/s SK Traders L1 | ARTI CONSTRUCTION L5 | BHAVNA IMPERIAL ENTERPRISE L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking out old U/S of LT cable of size 70/95 Sqmm 3.5 Core from trench complete all as specified and as directed. | 1,250 | RM | 4 ₹5,000 | 2 ₹2,500 | 5 ₹6,250 | 4 ₹5,000 | 4 ₹5,000 |
| 2.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95sq mm 3.5 core complete all as specified and as directed. | 500 | RM | 490 ₹2.5 L | 570 ₹2.9 L | 500 ₹2.5 L | 480 ₹2.4 L | 777 ₹3.9 L |
| 3.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70sq mm 3.5 core complete all as specified and as directed. | 500 | RM | 390 ₹1.9 L | 460 ₹2.3 L | 400 ₹2 L | 380 ₹1.9 L | 626 ₹3.1 L |
| 4.00 | Labour only for relaying of LT cable of size 70 Sqmm 3.5 Core to 95 Sqmm from trench for relaying/connecting to LT Panel complete all as specified and as directed.
Note : Old serviceable retrieved Items from serial item No 1.00 here-in-before shall be used under this item. | 250 | RM | 15 ₹3,750 | 5 ₹1,250 | 10 ₹2,500 | 16 ₹4,000 | 6 ₹1,500 |
| 5.00 | Supply, laying & testing cable XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) with stranded aluminium conductor, 11000 volts grade, of size 3 core 95 sqmm including taking out old U/S HT cable from trench complete all as specified and as directed complete all as specified and as directed.
Note SI Item NO 2, 3 & 5 :
(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
(ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.). | 1,180 | RM | 890 ₹10.5 L | 1,095 ₹12.9 L | 825 ₹9.7 L | 950 ₹11.2 L | 1,190 ₹14.0 L |
| 6.00 | Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, including taking out bricks/cable cover for protection removal to store for re-use or for credit etc complete all as specified and directed.
Note:
(i) Excavation for LT/ HT cable network shall be carried out manually | 700.11 | Cum | 190 ₹1.3 L | 249 ₹1.7 L | 200 ₹1.4 L | 230 ₹1.6 L | 290 ₹2.0 L |
| 7.00 | Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed. | 476.74 | Cum | 90 ₹42,906.60 | 80 ₹38,139.20 | 80 ₹38,139.20 | 110 ₹52,441.40 | 44 ₹20,976.56 |
| 8.00 | Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed. | 223.37 | Cum | 110 ₹24,570.70 | 90 ₹20,103.30 | 100 ₹22,337 | 120 ₹26,804.40 | 20 ₹4,467.40 |
| 9.00 | Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and as directed.
Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment. | 150.82 | Cum | 600 ₹90,492 | 1,000 ₹1.5 L | 500 ₹75,410 | 615 ₹92,754.30 | 700 ₹1.1 L |
| 10.00 | Supplying and laying in replacement for un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed | 5,000 | Each | 18 ₹90,000 | 18 ₹90,000 | 15 ₹75,000 | 19 ₹95,000 | 19 ₹95,000 |
Tender Value
₹38.4 L
EMD Value
₹76,800
Closing Date
20 Dec 2025, 6:00 pmClosed
CWE (AF) Jamnagar
CWE (AF) Jamnagar Air Force Jamnagar
SPECIAL REPAIR/REPLACEMENT OF LT UG CABLE FROM MAFI SOURCE TO DVOR, LOCALIZER, RVR-30 AND BASE OPS IN TECH AREA UNDER GE (AF) JAMNAGAR NO 01
2025_MES_741997_1
81266/E8
Open Tender
Electrical and Maintenance Works
180 days
Jamnagar
As per NIT
7 documents required · 7 mandatory
₹500
GE(AF) Jamnagar No 1
₹76,800
Yes
14 Jan 2026
28 Nov 2025
22 Dec 2025
28 Nov 2025
20 Dec 2025
13 Dec 2025
Amount
Taking out old U/S of LT cable of size 70/95 Sqmm 3.5 Core from trench complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95sq mm 3.5 core complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70sq mm 3.5 core complete all as specified and as directed.
Labour only for relaying of LT cable of size 70 Sqmm 3.5 Core to 95 Sqmm from trench for relaying/connecting to LT Panel complete all as specified and as directed. Note : Old serviceable retrieved Items from serial item No 1.00 here-in-before shall be used under this item.
Excavation in trenches in soft/loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc. and getting out, including taking out bricks/cable cover for protection removal to store for re-use or for credit etc complete all as specified and directed. Note: (i) Excavation for LT/ HT cable network shall be carried out manually
Returning, filling in trenches (soil), including spreading, leveling and well ramming in layers not exceeding 25 cm thick, complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50metre and depositing where directed at a level not exceeding 1.5metre above the starting point, complete all as specified and as directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and as directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supplying and laying in replacement for un-reinforced precast concrete cable cover, classLV, Type 1, flat, size 250 mm x 150mm x 40mm complete all as specified and as directed
Supply and laying in replacement for un-reinforced precast concrete cable cover, classHV, Type 1, flat, size 300 mm x 180mm x 40mm complete all as specified and as directed.
Supply and fix cable for jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material heat Shrink type and accessories suitable for 3 ½ / 4 core XLPE, armoured, Al conductor cable of size 70 to 95 sqmm, Indoor/Outdoor type omplete all as specified and as directed.
Supply and fix for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 Core omplete all as specified and as directed.
M & L in replacement for Bus bar chamber box outdoor type made out of mild steel CRCA sheet 3.15mm thick duly painted with synthatic enamal paint (internally and externally) over a coat of red oxide primer including aluminum bus bar four nos of capacity 250A and fixing with angle iron of size 40x40x5 mm of hight 1.2 M with painting including PCC foundation complete all as specified and directed
M & L in replacement for Bus bar chamber box outdoor type made out of mild steel CRCA sheet 3.15mm thick duly painted with synthatic enamal paint (internally and externally) over a coat of red oxide primer including aluminum bus bar four nos of capacity 250A and incomming MCCB 160A 4 Pole fixing with angle iron of size 40x40x5 mm of hight 1.2 M with painting including PCC foundation with complete all as specified and as directed
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1, including angle iron frame 50x50x5mm so that bottom of panel shall be 90cm from GL incl excavation earthwork painting finishing painting with power coated epoxy finish of approved colour over a coat of red oxide primer on frame surfaces platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer and and two coats of acrylic paint on PCC plateform and including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 320 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (vi) MCCB 63 Amps, 415V, 4 pole, 16 KA - 06 Nos (Out going) (vii) MCCB 100 Amps, 415V, 4 pole, 16 KA - 02 Nos (Out going)
Supply, installing, testing and commissioining in replacement of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1, including angle iron frame 50x50x5mm so that bottom of panel shall be 90cm from GL incl excavation earthwork painting finishing painting with power coated epoxy finish of approved colour over a coat of red oxide primer on frame surfaces platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer and and two coats of acrylic paint on PCC plateform and including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 200 Amps,415V, 4 Pole, 35 KA - 01 No (In coming) (vi) MCCB 63 Amps, 415V, 4 pole, 16 KA - 05Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1, including angle iron frame 50x50x5mm so that bottom of panel shall be 90cm from GL incl excavation earthwork painting finishing painting with power coated epoxy finish of approved colour over a coat of red oxide primer on frame surfaces platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer and and two coats of acrylic paint on PCC plateform and including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 600 Amps for phases and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 400 Amps,415V, 4 Pole, 50 KA - 01 No (In coming) (vi) MCCB 200 Amps, 415V, 4 pole,35 KA - 02Nos (Out going) (vii) MCCB 160 Amps, 415V, 4 pole, 25 KA - 03 Nos (Out going) (vii) MCCB 100 Amps, 415V, 4 pole, 25 KA - 02 Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1, including angle iron frame 50x50x5mm so that bottom of panel shall be 90cm from GL incl excavation earthwork painting finishing painting with power coated epoxy finish of approved colour over a coat of red oxide primer on frame surfaces platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer and and two coats of acrylic paint on PCC plateform and including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 600 Amps for phases and 300 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 320 Amps,415V, 4 Pole, 50 KA - 01 No (In coming) (vi) MCCB 250 Amps, 415V, 4 pole,35 KA - 01Nos (Out going) (vii) MCCB 100 Amps, 415V, 4 pole, 25 KA - 02Nos (Out going)
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1, including angle iron frame 50x50x5mm so that bottom of panel shall be 90cm from GL incl excavation earthwork painting finishing painting with power coated epoxy finish of approved colour over a coat of red oxide primer on frame surfaces platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer and and two coats of acrylic paint on PCC plateform and including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment.(ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches.(iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) Change over swich 250 Amps,415V, 4 Pole, (vi) MCCB 250 Amps, 415V, 4 pole,35 KA - 01Nos (vii) MCCB 100 Amps, 415V, 4 pole, 25 KA - 01 Nos (vii) MCCB 125 Amps, 415V, 4 pole, 25 KA - 02 Nos
Supply, installing, testing and commissioining of LT cubical panel board, 440 Volts, 50 Hz, 3 phase, 4 wire out door type weather vermin, dust proof front operated with adequate air ventilation at sides and back fabricated out of 3.15 mm thick CRCA sheet with double door shutter and locking arrangements, cable trays cable lugs etc including provision for taking out incoming and outgoing cables duly marked with relevetted letter plates of appropriate size for each feeder cables danger boards etc, suitable to accommodate and including the following mentioned fittings; floor mounted with PCC 1:2:4 type B1, including angle iron frame 50x50x5mm so that bottom of panel shall be 90cm from GL incl excavation earthwork painting finishing painting with power coated epoxy finish of approved colour over a coat of red oxide primer on frame surfaces platform; nut,bolts, washers etc for grouting and painting with powder coated epoxy finish of approved colour over a coat of red oxide primer and and two coats of acrylic paint on PCC plateform and including taking down old unserviceable existing LT Panel board with all accessories all as specified and as directed comprising the following:-
(i) Bus bar chamber consisting of four Nos aluminium bus bar duly sleeved of capacity 400 Amps for phases and 200 Amps for neutral duly insulated with PVC sleeves RYB, mounted on heavy duty epoxy insulation in separate compartment. (ii) LED type indicating lamps (RYB) with holders controlled by fuzes and switches. (iv) Panel board internal wiring with suitable rated PVC insulated copper conductors. (v) MCCB 315 Amps, 415V, 4 pole,50 KA - 01Nos (In coming) (vii) MCCB 160 Amps, 415V, 4 pole, 35 KA - 02 Nos (Outgoing) (vii) MCCB 125 Amps, 415V, 4 pole, 25 KA - 02 Nos (Outgoing)
JAYESH TRADING CORPORATION (BID ID -3503628)
Sukhi Electricals (BID ID -3501459)
BHAVNA IMPERIAL ENTERPRISE (BID ID -3503366)
ARTI CONSTRUCTION (BID ID -3502682)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.18 MB
BOQ_830865.xls
BOQ • 0.32 MB
81266Tender.pdf
Tender Documents • 0.45 MB
Download all tender documents and submit your bid