| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.7 LAccepted-AOC | ₹6.7 L Quoted ₹7.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.8 L+₹83,820 (12.0%)Rejected-Finance 108 MARUTI COMPLEX NEAR DIGVIJAY TIN FACTORY MILE STONE BUILDING KV ROAD JAMNAGAR 361001 | JAMNAGAR | JAMNAGAR | GUJARAT | 361001 | ₹7.8 L+₹83,820 (12.0%) | L2 | Rejected-Finance NOT L1 |
| 3 | L3₹8.0 L+₹98,886 (14.1%)Rejected-Finance 58 MODERN MARKET NEAR AMBER CINEMA JAMNAGAR | JAMNAGAR | ₹8.0 L+₹98,886 (14.1%) | L3 | Rejected-Finance NOT L1 |
| 4 | L4₹9.0 L+₹2.0 L (28.5%)Rejected-Finance | ₹9.0 L+₹2.0 L (28.5%) | L4 | Rejected-Finance NOT L1 |
| 5 | L5₹9.7 L+₹2.7 L (39.0%)Rejected-Finance 201 JITENDRA LODGE BUILDING 20 NEW JAGNATH PLOT RAJKOT | RAJKOT | RAJKOT | GUJARAT | ₹9.7 L+₹2.7 L (39.0%) | L5 | Rejected-Finance NOT L1 |
Tender Value
₹8.5 L
EMD Value
₹17,000
Closing Date
20 Jan 2020, 6:00 pmClosed
AGE I A Jamnagar
INFANTRY LINES JAMNAGAR
REPAIRS TO SUMMER APPLIANCES SUCH AS CEILING FANS, EXHAUST FANS, GEYSERS AND CONNECTED ITEMS AT MD ACCN AT MIL STN JAMNAGAR
2019_MES_303387_2
8685
Open Tender
Civil Works
Item Rate
120 days
Jamnagar
AS PER TENDER DOCUMENTS
6 documents required · 6 mandatory
₹500
₹17,000
Yes
19 Mar 2020
28 Dec 2019
21 Jan 2020
29 Dec 2019
20 Jan 2020
29 Dec 2019
Amount
Disconnecting/taking down and refixing of ceiling fans/exhaust fans electrically & mechanically for maint at site /store yard for cleaning of body along with cleaning & washing of blades externally, removing all type of dust and dirts, including servicing, checking of split pin, clutch, checknut,down rod, canopy existing size replacement of spare parts complete all as specified and directed by Engineer-in-Charge.
Repairs to ceiling fans including replacement of condenser 2.5 Mfd including dismantling of unserviceable condenser, reconnection and testing complete all as specified and directed by Engineer-in-Charge. Make: Havells/Tibcon/Seimens/Usha
Taking down and refixing at site ceiling fans/Exhaust fans/Air circulator including opening of fans and cutting down burnt winding and rewinding with new super enamelled copper winding of same guage as per existing winding, varnishing, drying etc reassembling the same including any type of lathe work,Bush to Bearing ,lubricating with approved lubricant, capacitor clamp, necessary transportation etc., complete for the following sizes of fans :-
(a) Ceiling fan of 1200mm sweep.
(b) Ceiling fan of 1400mm sweep.
(c) Exhaust fan of 230/300/325mm sweep.
(d) Exhaust fan of 380/400/450mm sweep.
Repairs to Exhaust fans of any size including removing of unserviceable condenser and replacement with new condenser 4 Mfd (+) or (-) 10% of approved make including connecting soldering complete all as specified and directed by Engineer-in-Charge. Make: Havells/ Seimens/TIBCON/Usha
Repairs to ceiling fans including dismantling, removing of unserviceable ball bearing and replacement with original size ball bearing of following sizes and approved make to suit the respective make including testing and commissioning complete all as specified and directed by Engineer-in-Charge. : Make:Tata
(a) Ball bearing No 6201
(b) Ball bearing No 6202
(c) Ball bearing No 6203
M&L for painting of complete ceiling fans, exhaust fans at site, with one coat of synthetic enamel paint (white/smoke grey) including writing of MES No. with black paint complete all as specified and directed by Engineer-in-Charge.
(a) Ceiling fan of 1200mm sweep.
(b) Ceiling fan of 1400mm sweep.
(c) Exhaust fan of 230/300/325mm sweep.
(d) Exhaust fan of 380/400/450mm sweep.
Supply & Fixng ceiling fan blades (set of three) suitable for any make and size as approved and directed by Engineer-in-Charge.
Supply & Fixing canopy suitable for ceiling fan of any make and size as approved and directed by Engineer-in-Charge.
Supply and fix in repairs Electronic fan regulator step type(5steps) 2module 100/120w ISI marked by removing old u/s resistance type fan regulator including necessary connection in existing laminated switch board by making necessary holes etc., complete all as specified and directed by Engineer-in-Charge.
Disconnecting electrically, mechanically and taking down defective electric water heater of any make and any capacity (15/25/50 Ltr) vertical or horizontal from site/store yard, cleaning of tank after opening of its upper & down assembly, cleaning of assembly pipe to avoid choke up, replacement of defective parts catered under the items s&f in repair here under including servicing of water heater and refixing complete all as specified and directed by Engineer-in-Charge.
Supply and fixing in repairs heating elements ISI marked of size 1.5/2 KW 230 Volts required for Geysers of 15/25 Ltrs capacity any maka as per existing
S&F in repairs thermostat ISI marked of 20 to 89 degree celcius suitable for electric geysercomplete all as specified and directed by Engineer-in-Charge.
S&F in repairs combined assembly of heating element and thermostat required for 15/25Ltrs Geyser Make:- Bajaj new shakti
S&F in repairs indicator lamp for Geyser of capacity 25 / 50 ltrs complete all as specified and directed by Engineer-in-Charge.
S&F in repairs non return valve ISI marked of size 15mm complete all as specified and directed by Engineer-in-Charge.
S&F in repairs PVC pipe connection 60cm long with brass nuts, washers heavy duty, treaded, suitable for inlet / outlet side of Geysers complete all as specified and directed by Engineer-in-Charge.
S&F in repairs DB sheet metal enclosure with socket and plug top with MCB SP 16 Amps C series 240 volts complete all as specified and directed by Engineer-in-Charge.
S & F in repairs to 2.5 Sq.mm 3 core copper conductor flexible cable haavy duty PVC insulated sheathed cable suitable for geyser / Exhaust fan/AC complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Clamp Heavy duty for hanging celing fan as per existing size including 2 No of Nuts bolts with lock pin rubber seal complete all as specified and directed by Engineer-in-Charge.
S & F in repairs Ceiling fan Down rods 30/45cm long complete as per existing size complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair Anchor bolt 6" length with nut and washers, suitable for fixing of water heater Geyser complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair medium grade 15mm dia GI X nipple suitable for connection of water heater Geyser complete all as specified and directed by Engineer-in-Charge.
Supply & fixing in repair Copper Flexible cable twisted 3core 1.00 Sqmm for fan connection complete all as specified and directed by Engineer-in-Charge.
S&F in repair plug top 3 pin, 15/16 Amps including taking down the existing defective plug top complete all as specified and directed by Engineer-in-Charge.Make: Anchor
S&F in repair switch socket outlet combination 5 Amps and 15 Amps multipurpose( 2 in 1, 3 pin, 5 and 15 Amp flush type universal) .
WINDOW/ SPLIT TYPE AC
Tracing out the leakage from suction line, discharge line, evaporation condenser, filter, capilary tube by suitable method including brazing, welding, replacement of filter Strainer charging line and filling of gas R-22 in window type AC capacity 1.5/2 TR
Tracing out the leakage from suction line, discharge line, evaporation condenser, filter, capilary tube by suitable method including brazing, welding, replacement of filter Strainer charging line and filling of gas R-22 split type A/C 1.5 /2.0 Ton capcity
Removing existing unserviceable compressor cut/uncut from window type/split A/C and S&F in replacement factory reconditioned clean compressor ( with 1 year replacement warranty), in exchange suitable for 1.5/2 ton capacity A/C including fixing in original position, with filling of gas R-22 and pressure testing including welding, brazing replacement of filter/Strainer made of copper capilary tube, complete all as specified and directed by Engineer-in-Charge.
S&F in replacement starting capacitor of 100/120 MFD, 230 Volt AC suitable for 1.5 TR/2.0TR capacity AC Make : Usha/Keltron/ BHEL /KEL/Texla
S&F in replacement running capacitor 50/4 mfd 230 Volt AC suitable for 1.5 Ton capacity AC .complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor, 6 MFD, 440 Volt AC suitable for condenser motor 1/6 HP 1350 RPM complete all as specified and directed by Engineer-in-Charge.
S&F in replacement overload protector AC suitable for 1.5 TR/2.0 TR capacity complete all as specified and directed by Engineer-in-Charge. Make : Usha /Shriram
S&F in replacement starting relay box type R-22 suitable for 1.5TR/2.0TR capacity A/C complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of fan blade for condenser motor of window /split type AC complete all as specified and directed by Engineer-in-Charge.
Removing of existing unserviceable burnt condenser motor from window/split type AC 1.5/2.0 ton capacity and S&F in replacement condenser motor of capacity 1/6 HP 1350 RPM as per existing single phase 230 V including fixing in original position with replacement rubber bush of motor mounting, testing complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of copper condenser in split type air conditioner outdoor unit complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of electronic circuit complete including controling unit ie (Remote ) all as per existing sample and suitable for 1.5 / 2.0 Ton capacity split type AC complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Copper pipe 1/4 with U Foam for 1.5/2 ton capacity split AC all as directed by Enrg-in-Charge
S&F in replacement of Copper pipe 5/8 with U Foam for 1/5/2 ton capacity split AC all as directed by Enrg-in-Charge
S&F in replacement of copper AC suction valve of size 5/16 all as directed by Engr-in -charge
S&F in replacement of copper AC suction valve of size 5/8 all as directed by Engr-in -charge
S&F in replacement of rubber pipe for waste water of 15mm complete all as specified and directed by Engineer-in-Charge.
REFRIGERATORS
M & L Tracing out the leakage from suction/ discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-134a, replacement of strainer, capilary tube, nut bolts of compressor of refrigerators of different capacities etc.complete all as specified and directed by Engineer-in-Charge.
Removing existing unserviceable compressor cut/uncut from Refrigerator capacity 286/310 ltrs and S&F in replacement factory reconditioned compressor ( with 1 year replacement warranty) clean exchange including fixing in original position charging of gas R-134a, replacement of strainer, capillary tube complete all as specified and directed by Engineer-in-Charge.
S&F in replacement thermostat defrost type for refrigerator. complete all as specified and directed by Engineer-in-Charge.
S&F in replacement condenser in outer side of refregerator complete all as specified and directed by Engineer-in-Charge.
S&F in replacement 15 Watt lamp screw/Pin type for refrigerator. Make : Phillips/Bajaj
S&F in replacement of Cooling coil with PVC freezer door complete with screw/nut bolt suitable for 286/310 ltrs capacity refrigerator.
S&F in replacement of over load relay suitable for 280/310 Ltrs capacity refrigirator as per existing complete all as specified and directed by Engineer-in-Charge..
WATER COOLER
Tracing out the leakage from suction/discharge line, condenser and alike by suitable method including brazing, welding, gas charging R-22, replacement of strainer, capilary tube, nut bolts of compressor of water cooler 40/80 ltrs capacity.complete all as specified and directed by Engineer-in-Charge.
M&L Removing of existing unserviceable compressor cut/uncut from water cooler 120/150 ltrs capacity and S&F in replacement factory reconditioned clean compressor ( with 1 year replacement warranty) suitable for existing water cooler 120/150 ltrs capacity including fixing in original position with filling R-22 gas charging and pressure testing ,brazing replacement of stainer, capilary tube cleaning of condenser coil etc complete all as specified and directed by Engineer-in-Charge.
M&L Removing existing unserviceable condenser motor and M&L for rewinding of existing condenser motor with super enameled copper wire as per existing size and gauge of capacity 1/30 HP single phase 1350 RPM including testing, refixing complete.complete all as specified and directed by Engineer-in-Charge.
S&F in replacement starting relay box type for 120/150 ltrs capacity Water Cooler including overload protector complete
S&F in replacement thermostat including knob, plate and screw suitable for 120/150 ltrs capacity storage type water cooler. complete all as specified and directed by Engineer-in-Charge.
S&F in replacement push cock, lifting cock 15mm size as per existing pattern for water cooler complete all as specified and directed by Engineer-in-Charge.
S&F in replacement PVC drain pipe approx 1.5 mtr long of 25mm dia for water cooler complete with clamp screws etc complete for drainout water from water cooler complete all as specified and directed by Engineer-in-Charge.
Supply & connect in replacement flexible wire 3 core 3 Mtr long of size 40/0.0076 PVC sheathed copper flexible cable to water cooler 120/150 ltrs capacity . complete all as specified and directed by Engineer-in-Charge.
S&F in replacement Float valve, chromium plated with polythene PVC ball for 15mm (1/2") bore size suitable for 40/80 ltrs capacity water cooler.complete all as specified and directed by Engineer-in-Charge.
S&F chromium plated drain pot suitable for collecting drain water from 120/150 ltrs water cooler, as per existing pattern complete all as specified and directed by Engineer-in-Charge.
Removing existing unserviceable condenser motor and S&F in replacement condenser motor 1/30 HP single phase 1350 RPM complete all as specified and directed by Engineer-in-Charge.
S&F in replacement capacitor 10 MFD, 440 Volt AC.complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of condenser fan blade aluminium suitable for motor 1/30 or 1/32 HP for water cooler 120/150 ltrs capacity. complete all as specified and directed by Engineer-in-Charge.
MAINTENANCE OF SERVICEABLE APPLIANCES
Removing window/Split type A/C unit 1.5/2.0 ton capacity from existing position (Indoor & Outdoor unit both in case of split AC) and washable servicing the same by complete cleaning & washing the dust by suitable blower machine method including supply and replacement of air filter, damaged wires with copper wire PVC insulated of same size, tightening of loose wire, nuts, bolts, servicing of condenser motor, by oiling, greasing, supply and replacement of bushes of condenser motor, damaged knobs, setting of grills alignment complete including refixing in original position including provision of thermocoal for air thightness, testing and commissioning to the entire satisfaction of Engineer-in-Charge.
Removing storage type water cooler 120/150 ltrs capacity from existing position and servicing the same by cleaning of water tank, cleaning other dusted parts, with hand blower and including supply and replacement of damaged aluminium hinges 2 Nos 100mm, nuts, bolts, screws, lockiing system, wiring with PVC insulated copper wire of same gauge, PVC drain pipe 25mm dia, 1.5 mtr long, servicing of condenser motor, supply & replacement of bushes, tightening of all loose parts, contacts, wiring, nuts, bolts, 15 Amps Plug top complete including refixing in original position, testing & commissioning, to the entire satisfaction of Engineer-in-Charge.
Removing refrigerator 286/310 ltrs capacity from existing position and complete servicing the same by cleaning internal & external surfaces, supply and replace of damaged knob of thermostat, Aluminum/Steel rods of indoor cabin, damaged wiring with PVC insulated copper wire of same gauge, lamps, door key, fixing all disconnected parts properly tightening of loose wires, nuts-bolts and making fully functional and refixing in original position, testing, complete all as directed by Engineer-in-Charge.
Supply and fix voltage stablizer in replacement for automatic operation, single phase designed for input variation between 150 Volt to 285 Volt with output Voltage stablized at 230 Volt with accuracy of + 2.5 % and of capacity of 4 KVA/12 Amp. complete all as specified and directed by Engineer-in-Charge. Make : VND 400 of V Guard, Servo
Supply and fixing in repairs Plastic body exhaust fan 250 mm sweep AC, 240 volts fixed as per manufacturer instruction, connecting with and including 1.5 Sqmm copper conductor, PVC insulated and PVC sheathed three core cable including provn of hole and aluminium frame etc for fixing the fan as required at site complete all as specified and directed by Engineer-in-Charge. Make :Orient / Crompton/ Havells/Bajaj
Rameshwar Enterprise
fakhrie apostrical
Dara Paras.D
Quick Building Service
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .