Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC | ₹38.6 L Quoted ₹39.0 L | L1 | Accepted-AOC BEING L1 |
| 2 | L2₹43.5 L+₹4.5 L (11.5%)Rejected-Finance | ₹43.5 L+₹4.5 L (11.5%) | L2 | Rejected-Finance BEING L2 |
| 3 | L3₹44.9 L+₹5.9 L (15.1%)Rejected-Finance | ₹44.9 L+₹5.9 L (15.1%) | L3 | Rejected-Finance BEING L3 |
| 4 | L4₹46.1 L+₹7.1 L (18.2%)Rejected-Finance GANDHI NAGARI AIRPORT ROAD BHUJ KUTCH PIN 370 001 GUJARAT | KACHCHH | GUJARAT | 370001 | ₹46.1 L+₹7.1 L (18.2%) | L4 | Rejected-Finance BEING L4 |
| 5 | L5₹46.2 L+₹7.2 L (18.4%)Rejected-Finance | ₹46.2 L+₹7.2 L (18.4%) | L5 | Rejected-Finance BEING L5 |
Tender Value
₹42 L
EMD Value
₹84,000
Closing Date
12 Jan 2024, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
SPECIAL REPAIR TO WASHROOM OF CERTAIN BLDGS, ADDN / ALTN TO BLDG NO 191 AND PROVN OF TILING IN CERTAIN OMQs AT AFS VADODARA
2023_MES_632867_1
8859/E8
Open Tender
Civil Works
Item Rate
180 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
4 documents required · 4 mandatory
₹500
GE AF BARODA
₹84,000
Yes
7 Feb 2024
15 Dec 2023
19 Jan 2024
15 Dec 2023
12 Jan 2024
29 Dec 2023
16 Dec 2023 - 22 Dec 2023
Amount
Taking down Chowkats or frames with shutter (without taking off shutter from the frame) exc. 1.5 sq. m and n.exc 4.00 sqm each removing to store complete all as specified and directed.
Taking down Chowkats or frames with shutter (without taking off shutter from the frame) not exc. 1.5 sq. m each and removing to store complete all as specified and directed.
Taking down shutters of any description exc 1 Sqm & nexc 2 Sqm complete all as specified and directed.
Demolition of cement Concrete (unreinforced) of any description and in any position complete all as specified and directed.
Demolition of brickwork or stone/boulder masonry built in cement mortar incl all quoins, arches pillars etc but excluding ashlar facings complete all as specified and directed.
Dismantling structural steel work including doors, gates but excluding framed truss etc. complete all as specified and directed.
Taking down cement plaster of any description on brick or stone wall/ celling including raking out joint , hacking for key and scrubing with water etc complete all as specified and directed
Dismantling floor hearth or wall tilling including cement mortar bedding (but not backing) rubbish off the premises complete all as specified and directed
Demolition of cement Concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Taking up or down steel tubing and connections 15mm bore complete all as specified and directed
Taking up or down steel tubing and connections 20mm bore complete all as specified and directed
Taking up or down steel tubing and connections 25mm bore complete all as specified and directed
Dismantling water tanks and removing to store of capacity exc 250 & n exc 500 litre complete all as specified and directed.
Dismantling water tanks and removing to store of capacity exc 1000 & n exc 2000 litre complete all as specified and directed.
S&F Factory made flush shutters 35mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides as in CB shutter complete all as specified and directed
S&F 5mm thick tinted glass and glazing with glazing clip and powder coated aluminium beading in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying and fixing in opening complete all as specified and directed
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification drawing complete all as specified and directed
S&F 75 mm size butt hinges stainless steel medium weight complete all as specified and directed.
S&F 100mm long butt hinges medium weight, cold rolled mild steel and fixed to frame with screws or welding complete all as specified and directed
S&F 200mm long aluminium anodized barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F 150mm long aluminium anodized barrel tower bolts of extruded section and fixed complete all as specified and directed
S&F aluminium anodized sliding door bolt with haps and staple (bolt type) and fixing clip of sheet cast or extruted section or cast aluminium alloy and fixed length of bolt 300mm complete all as specified and directed
S&F 150 mm long aluminium handle cast type anodized complete all as specified and directed
S&F Powder coated aluminium work for door, windows and ventilators and and partition wall etc with one or more rebates fixed in position as per manufacturer's instruction including necessary joining cleat, glazing clips, rubber packing, beading ,plaster work on edges during fixing (if required) etc complete all as specified and directed. Note: Weight of aluminium section shall only be measured for payment.
M&L for Preparation of new wooden surface of any description not otherwise described over 10cm width or grith and applying two coats of synthetic enamel paint over and including one coat of pink primer complete all as specified and directed
M&L for providing cement concrete type B-0, 1:2:4 using 12.5mm graded aggregate laid to slope 1:30 in padding for WPT over roof slab,filling of pressed steel door frame complete all as specified and directed
Removing existing unserviceable water proofing treatment taking down cement plaster etc, of any description and cleaning of top surface of cement concrete flushing out junction of parapet walls & washing down with water to remove all dirt etc including preparation of surfaces to receive new treatment and removing the rubbish off premises complete all as specified and directed
M&L for applying cold bituminous primer @ 0.30 ltr/Sqm confirming to IS-3384 and laying APP polymer modified fiber glass reinforced membrane 3mm thick weight not less than 3.5kg/sqm (modified bituminous water proofing membrane ) with plain finish with polyester base reinforcement, sealing all over with lap of 100mm in length side and 150mm on width side of membrane by torching the same and including applying a coat of bituminous aluminium paint @ 100 gms/sqm all as per manufacturer instructions complete all as specified and directed .
M&L10 mm thick screed bed in CM 1:4 mixed with WPC 3% by weight of cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately under respective item of BOQ.
Supply only integral water proofing compound (Powder) complete all as specified and directed.
Disconnecting existing tanks, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including cleaning and removing all scale and dirt, etc, from tanks exc 250 and n.exc 500 ltr capacity and from mouths of circulating pipes, etc complete all as specified and directed.
M&L Brickwork with subclass 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed.
M&L rendering 15 mm thick cement plaster on fair faces of brick surface/concrete surfaces in CM 1:4 complete all as specified and directed.
M & L for framed work such as grills, gratings, etc with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors;ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed
M&L rendering 10 mm thick cement plaster on fair faces of brick surface/concrete surfaces in CM 1:6 complete all as specified and directed.
M&L for rendering 5mm thick on concrete surfaces of ceiling in CM 1:3 finishing the surface even and smooth without using extra cementcomplete all as specified and directed.
M&L for preparing newly plastered surfaces of wall and applying two coats of oil bound distemper over and including a coat of primer complete all as specified and directed.
M & L for preparation of new surfaces of steel or iron over 10cm width or girth and applying two coats of synthetic enamel paint over and including a coat of red oxide zinc chrome primer complete all as specified and directed
M&L for preparing newly plastered surfaces of wall and applying two coats of cement based paint over and including a coat of primer complete all as specified and directed.
M&L for preparing newly plastered or unplastered surfaces of ceiling and applying three coats of white wash complete all as specified and directed.
M&L for providing 100mm thick Plain cement concrete 1:2:4 Mix, type B-2 (using 40mm graded crushed stone aggregate) as in path finished surfaces even and fair without using extra cement complete all as specified and directed
M&L for PCC 1:3:6 type C2 (40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M&L for PCC 1:2:4 type B2 (40mm graded aggregate) as in foundation, filling and mass concrete complete all as specified and directed.
M& L for Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and directed.
M&L for sand filling under floor or in foundations including watering and consolidation in layers complete all as specified and directed.
M&L for cement concrete pre polished chequered paver tiles of size 305x305x20mm thick of approved colour and design, set and jointed in neat cement slurry and pointed in white/ coloured cement to match the shade of tiles complete all as specified and directed.
M&L for Non - skid Ceramic tiles 7 to 8 mm thick (square /rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm, confirming to IS: 15622:2006 grade B II matt superior finish, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 20 mm thick screed bed in CM 1:4 complete all as specified and directed.
M&L for Glazed ceramic coloured tiles in vertical surface such as dado/skirting etc of size 450X 300X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in CM 1:3 as backing coat complete all as specified and directed.
S&F 15mm bore Tubes, 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 20mm bore Tubes, 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F 25mm bore Tubes, 'Medium grade' galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 500 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks 2000 ltr capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I complete all as specified and directed.
S&F stainless steel bright finish 150 x150mm size fixed grating over floor trap in white or gray cement to match with existing floor complete all as specified and directed.
S&F 10 litres capacity PVC valveless symphonic action type, flushing cistern, low level, white, with inlet, ball valve float handle including brackets complete all as specified and directed
S&F in repairs Stop valves, cast copper alloy, chromium plated, fancy type screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for runions and fixed to 15mm bore pipe complete all as specified and directed
S&F in repairs Pillar taps, cast copper alloy, with capstan heads, chromium plated, fancy type, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed to 15mm bore pipe complete all as specified and directed
S&F in repairs vitreous China squatting pan, orissa pattern of size 580x440mm, white with integral foot rest (excluding flushing cistern and flush pipe) with CI P trap incl connection to trap & flushing pipe complete all as specified and directed
S&F vitreous china wash down water closet pen (pedestal pattern) white (excluding fixing both flushing cistern and flush pipe) including provn of plastic water closet seat with cover (White) closed pattern with flat bottom complete all as specified and directed
S & F in repair vitreous china wash hand basin, flat back, size 550x400mm with pedestal including waste pipe, waste coupling, PVC connection 450 mm long and brackets complete all as specified and directed
S&F in repair Vitreous China Urinal, Half stall type,white (excluding flushing cistern, flush pipe and waste pipe) including connections to flushing pipe and outgoing pipes complete all as specified and directed.
S&F in repair brass chromium plated 2 way angle cock fancy type suitable for 15 mm bore pipe complete all as specified and directed.
S&F Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position completein all respect as specified.
S&F PVC connection 15mm size with PTMT nuts of length 60 cm complete all as specified and directed
S & F 110 mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or in floor complete all as specified and directed.
Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of dia 150 mm complete all as specified and directed.
Excavation in trenches for not exc 1.5 mtr wide and not exc 1.5 mtr depth and getting out in soft/loose soil complete all as specified and directed.
M&L for concrete bed in cement concrete 1:3:6 type C-2 (Using 40 mm graded stone aggregate) to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm dia pipecomplete all as specified and directed
M&L for 150 mm dia RCC Hume pipe, class NP-2 ,ISI marked with collar laid and jointed in cement motar (1:1) complete including dismantling the existing drain/sewage pipe complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layers n.exc 25cm complete all as specified & directed.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position complete all as specified and directed
M&L for providing precast cement concrete 1:2:4 type B-1 (using 20mm graded aggregate) set in cement mortar 1:4 as in cover slab supported on wall complete all as specified and directed
M&L for TMT bars 6 to 8mm dia cut to length bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including MS wire (annealed) not less than 0.9mm dia complete all as specified and directed.
M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) fair finished surfaces of concrete flat complete all as specified and directed
S&F 4mm thick sheet glass, ordinary quality and glazing with glazing clip and powder coated aluminium beading in square n exc 0.5 sq. m in each pane complete all as specified and directed
S&F Stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.14mm and fixed with powder coated aluminium beading/ wooden beading complete all as specified and directed
M&L for Vitrified Ceramic tiles (light shade) 10 mm thick (square/ rectangular) polished (doubly charged), area of each tiles exceeding 0.09 sqm but not exceeding 0.36 Sqm in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thcik screed bed in CM 1:4 complete all as specified and directed.
M&L for Vitrified Ceramic tiles (light shade) 10 mm thick (square/ rectangular) polished (doubly charged), area of each tiles exceeding 0.09 sqm but not exceeding 0.36 Sqm as in vertical surfaces such as dado / skirting etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10mm thcik screed bed in CM 1:3 complete all as specified and directed.
M & L for pavement floor vitrified tiles of size exc 0.09 Sqm but not exc 0.36 sqm 10mm thick (Endura tiles of johnson or equivalent makes listed in list of makes) set jointed and pointed in neat cement slurry and pointed with grey cement and pigment to match the colour of tiles in floor including 20mm thcik screed bed in CM 1:4 completed all as specified and directed
M & L for 15 mm thick rendering in two layer 10mm thick backing coat in CM 1:6 and finishing coat 5mm in CM 1:4 mixed with and including water proofing compound in finishing coat on fair faces of brick masonary wall, finished even and smooth without using extra cement complete all as specified and directed
M&L for newly plastered surfaces of wall and applying two coats of exterior ACRYLIC Emulsion paint (Colour or shade as approved by GE) over and including a coat of primer as per manufacturers instruction complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed
M&L for old plastered surfaces of wall and applying one coat of exterior ACRYLIC Emulsion paint complete including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premise clean and tidy complete all as specified and directed
M&L for complete removal of existing treatment on wall surfaces by scraping down, rubbing down and washing with water to the satisfaction of Engineer-in-Charge and applying two coats of Oil Bound Emulsion distemper including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed .
M&L for preparing new/ old plastered surfaces of wall and applying 3 mm thick wall care putty complete all as specified and directed .
M&L for complete removal of existing treatment on wall surfaces by scraping down, rubbing down and washing with water to the satisfaction of Engineer-in-Charge and applying three coats of white was including cleaning window glasses, joinery, electric fittings, wiring etc of drops and splashes and cleaning premises clean and tidy complete all as specified and directed .
M&L for filling surface cracks not exc 5 mm to 7 mm wide with "Dr fixit" Cracks X power or equivalent polymer modified crack filler as per manufacturers instructions complete all as specified and directed.
S&F 12 mm thick glass shelf of size 600 mmx 250 mm with stainless steel brackets / rails of approved design / pattern complete all as specified and directed.
S&F factory made 18 (+/- 0.7) mm thick PVC sheet both side prelaminated sheet cabinet shutter and drawer boxes in cup board shape of density 600 Kg/ Cum bent at 90 degree and finished all edges at all levels for making edges lipping/ bedding or 0.5 mm thick PVC sheet lipping at all four edges using bonding tape including SS hinges and magnet, cup board knob, handles etc complete as per manufacturers instructions complete all as specified and directed.
M&L for providing false ceiling at all height using mineral fibre ceiling tiles of size 600 x 600 x 15 mm RH-99 type micro looks edge laid on super fine XL 15 exposed grid system with 15 mm wide T-section flanges. The frame work comprises of main runner of size 15 x 32 x 3000 mm spaced at 1200 mm centre securing fixed to the structural soffits by approved hangers at 1200 mm maximum centres. Hangers (GI wire 4.0 mm dia) to be fixed by approved roof plug , level adjusters and screws etc. The last hanger at the end of each main runner should not be greater than 450 mm from the adjacent wall flush fitting 1200 mm long cross Tee of size 15 x 26 x 1200 mm to be interlocked between main runners at 600 mm center to form a 1200 mm x 600 mm module. Cut cross Tee longer than that 600 mm to be supported independently. 600 mm x 600 mm modules to be formed by fitting 600 mm long flush fitting cross tee of size 15 x 26 x 600 mm centrally between the 1200 mm cross tees perimeter wall angle of size 19 x 19x 3000 mm secured to wall at 450 mm maximum centres. finally RH-99 mineral fibre tiles 15 mm thick micro look edge has to be laid on the 600 mm x 600 mm module complete all as specified and directed.
S&F 52mm thick PVC Partition consisting of 12mm thick plain solid PVC ply sheet reinforced with frame work made from 40mm x 20mm MS tubes. In between two MS tubes, 5mm thick Plain heat moulded 'C channel of size 75mmx50mm with feathered edges shall be fixed on the floor, wall and ceiling. Plastic ply opanel shall be inserted in the PVC 'C channel. The first & last MS tube should be errected such that it is inside a PVC 'C channel, in between adjoining plastic panel, 5mm thick x75mm width plain PVC sheet feathered at edges shall be stick on the front & back face using solvent cement complete all as specified and directed.
S&F Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing complete all as specified and directed.
S&F 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specification and drawing complete all as specified and directed.
Taking down carefully copper / Aluminium point wiring including (light, fan, socket or power complete fittings, such as switches, ceiling roses, pendant holders, Batten holders, shades conical fan regulators, light or power sockets etc) removing materials from site and making good disturbed surfaces of walls roofs etc complete all as specified and directed.
Material and labour for concealed point wiring with using 2 x 1.5 Sqmm (nominal area) stranded copper conductor single core, PVC insulated (FRLSH) & unsheathed cable, 1100 volts grade as per IS 694 for Phase and Neutral, 1x 1.5 Sq mm (nominal area) stranded copper conductor single core conductor, PVC insulated (In Green colour)& unsheathed cable as in earth wire connected to common earth dolly in concealed rigid PVC conduit size not less then 20mm dia as per site requirement of suitable size all as specified and directed with and including providing new SS sunken box incl all accessories complete all as specified and directed for the following :-
Note for item No 97.00 : (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
One light / fan/ exhaust fan point controlled by one, one way switch.
One 3 pin 5 Amps socket outlet on same board with other switch.
One light point controlled by one, one way switch on same board.
One 3 pin 5 Amps socket outlet on independent board with other switch
Description all as per item No.97.00 here-in-before but wiring with 2.5 sqmm multistranded copper conductor unsheathed and 2.5 sqmm copper conductor unsheathed cable as earth continuity conductor for one 3 pin 15 Amps socket outlet point on independent board. Note (i) The quoted rates shall be deemed to be inclusive for any cutting chases in brick walls/pillars etc for fixing of suncken boxes and flush it & making good the disturbed surface in cement mortar 1:4 including finishing the surface to match with existing surfaces and provision of covering modular sucken box and modular cover plate of any shape . (ii) Fittings like switches sockets regulators, lamp holders light fittings shall be measured and paid for separately under respective items of BOQ. (iii) The size of conduits shall be determined on permissible No of runs of wires as specified in SSR part I (2010) However minimum size of conduits shall be 20 mm dia (medium grade).
S&F MCB SP Isolator single pole, 5 to 30 Amps, 10 KA, 240 volts complete all as specified and directed
S&F MCB DB SPN double door, 230 volts, 4 way with IP-42 Protection complete with bus bar 200 amps capacity and neutral links complete all as specified and directed
S&F 4 way VTPN distribution box 415 Volts ( with 125 A FP MCCB and incommer and SP / TP MCB as outgoing complete all as specified and directed.
S&F MCB SPN 40 / 63 Amps, 10 KA,240 volts complete all as specified and directed
S&F round shape 12 Watt 220 Volts AC recessed type with high efficiency PMMA diffuser soft glaire free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size comple all as specified and directed.
S&F LED tube light 20 Watt, 230 Volts complete all as specified and directed.
S&F track wall light fitting COB 20 Watt round 6500 K TRCR20MB 60 230 Volts complete all as specified and directed. Make: PLTO101270 of Polycab or equivalent in ST700T LED 20 930PC PSU NB 1C WH IN of Philips or CDS-201-20-30-HL2-NBK of Crompton
S&F track wall light fitting COB 12 Watt round 6500 K TRCR12MB 60 230 Volts complete all as specified and directed. Make: PLTO101264 of Polycab or equivalent in ST700T LED 12 930PC PSU NB 1C WH IN of Philips or CDS-201-12-30-HL2-NBK of Crompton
S&F up down wall light fitting 10 Watt 230 Volts complete all as specified and directed.
Taking down and refixing of Air conditioner of any type and capacity after necessary servicing and top up of gas upto required level complete all as specified and directed.
M&L for sand cushioning with using clean dry and natural river sand including gently punning below/around cable complete all as specified and directed. Note: Depth of the sand shall be measured after punning.
M&L for Bricks; common burnt clay building bricks, sub-class designation of size 230mm x 115mm x 40mmclass for cable protection complete all as specified and directed.
S&F 50 mm dia tubes ‘Light grade’ galvanized with all fittings and fixed complete laid in trenches complete all as specified and directed.
Supplying, laying and testing of cable XLPE Insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, laid in trenches/duct or fied to wall/passing through pipe on pole with suitable size cable glands, crimping type cable lugs for stranded aluminium conductor of size 50 Sqmm, 4 Core, complete all as specified and directed. Notes : Earthwork, Sand and Covers shall be measured and paid separately.
M&L for Cutting existing 25 mm dia GI tubing for alterations or additions (Each cut measured) complete all as specified and direceted.
M&L for Cutting existing 20 mm dia GI tubing for alterations or additions (Each cut measured) complete all as specified and direceted.
M&L for Cutting existing 15 mm dia GI tubing for alterations or additions (Each cut measured) complete all as specified and direceted.
S&F 25mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 20mm Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 20 mm bore Ball brass valves, high pressure, with polythene float and fly nut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F Submersible pump 1 HP electric driven 220 V, 17-27 Meter Head, discharge 150-70 LPM, suitable for 25 mm dia outer diameter complete all as specified and directed.
S&F Submersible pump DOL starter suitable for 2 HP 220 V complete all as specified and directed.
S&F 20 mm Bib tap standard of PTMT any colour high pressure screwed for iron pipe and fixed (Minimum weight 15mm-90gms/20mm-125gms) complete all as specified and directed.
Supplying, laying and testing of cable PVC Insulated, PVC sheathed cable galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded copper conductor 1.5 Sqmm, 3 core, 1100 Volts grade complete all as specified and directed.
M & L for sub main wiring using two single core 10 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 10 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 10 sqmm and one run of 10 sqmm earth wire and one run of PVC conduit shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the quoted rate.
M & L for sub main wiring using two single core 4 Sqmm fire retardant PVC insulated and unsheathed cable with copper conductor 1100 volts grade ISI marked drawn through and including PVC Conduit or in existing concealed conduit (as required & directed by Engr-in-Charge) with accessories like bends, tee, etc fixed on wall and ceiling including 4 Sqmm earth wire, FR PVC insulated & unsheathed and connecting to earth dolly including taking down existing wiring complete all as specified and directed. Note: (i) Two runs of 4 sqmm and one run of 4 sqmm earth wire and one run of PVC conduit shall be measured as one unit. (ii) Necessary plastering to the disturbed surface of wall and distempering /white washing to match the existing colour shall deemed to be included in the quoted rate.
S&F Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 10 A complete all as specified and directed.
S&F switch piano Modular type single pole one way 6 Amp 240 Volts 1 Module complete all as specified and directed.
S&F socket 6 Amps 2 in 1 Socket with Shutter Modular type 240 Volt 2 Module complete all as specified and directed.
S&F switch piano Modular type single pole one way 16 Amp 240 Volts 1 Module complete all as specified and directed.
S&F socket 6/16 Amps 2 in 1 Socket with Shutter Modular type 240 Volt 2 Module complete all as specified and directed.
S&F ceiling rose PVC polycarbonate isolated body 65x50 mm three terminal complete all as specified and directed.
Taking down and refixing of ceiling fan of any description after painting and servicing complete all as specified and directed.
S&F indoor decorative box type fitting slim LED batten 18/20 Watt with Polycarbonate housing and diffuser AC 220-240 Volts, 50Hz and connecting with copper conductor flexible cable from ceiling rose to connector of light, fixed the same with two Nos PVC Square Box complete all as specified and directed.
S&F indoor decorative aesthetically designed Mirror Light provided with high output PMMA diffuser for glare free light including LED lamp (10 Watt) with provision of 2/3 core PVC copper conductor cable from ceiling rose to connector block, fixing the same with two number PVC Square Box complete all as specified and directed.
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable sizemcomplete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
Supply and Fixing exhaust fan, steel body heavy duty turboforce, AC single Phase. 230 V of size 450 mm sweep, 1200 RPM air delivery, 4 blades and frame and louvers gray colour, dust resistant including making hole on wall suitable for fixing of exhaust fan and making good disturbed surfaces of wall as per exisiting complete all as specified and directed.
Supply and Fixing LED security light luminaire 35 watt freedom , pressure die cast aluminum housing, heat resistant glass, IP66 protection, better optics for uniform distribtion complete with all accessories internally pre wired and including connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light including provn of bracket made out of 25 mm dia light grade GI pipe 1.0 M long incl fixing arrangements complete all as specified and directed
Material and labour for earthing complete with copper earth plate electrode 600mm X 600mm X 3.15mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to Galvanised Iron earth wire 4 mm dia by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed
shree nathji trading corporation
ASC CONSTRUCTION
OM SREE MAHADEV TRADERS
ABP CONSTRUCTION
JAI HANUMAN CONTRACTOR
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .