| 1 | L1₹4.8 LAccepted-AOC LEKSHMI DHATHAM VP 4 132 A PEYAD VILAPPIL PANANGODE 695573 | PANANGODE | THIRUVANANTHAPURAM | KERALA | 695573 | L1 | Accepted-AOC l1 | |
| 2 | L2₹5.7 L+₹90,278.65 (18.9%)Rejected-AOC | L2 | Rejected-AOC l2 |
Tender Value
₹6.1 L
EMD Value
₹15,274
Closing Date
26 Dec 2024, 6:00 pmClosed
AEE
PWD Electrical Sub Division Tvpm
GENERAL-Running maintenance contract to Electrical Installations in the RHS Quarters at Melarannoor, Poojappura, Thiruvananthapuram -works-General Electrical Work
2024_PWD_718255_1
ESDT/ET_144/2024-25
Open Tender
Electrical Works
Item Rate
180 days
PWD Electrical Sub Division Tvpm
please refer tender documents
6 documents required · 6 mandatory
₹1,350
₹15,274
15 Feb 2025
20 Dec 2024
28 Dec 2024
20 Dec 2024
26 Dec 2024
20 Dec 2024
Amount
Maintenance and repair
1.8.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
1.10.1:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group A
OD105002/2023-2024:Dismantling existing damaged double side frame Fittings and renewing same place for fixing 1200 mm LED Tube light made of CRCA with 0.5mm thickness complete with all accessories and directly fixed on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.
OD105003/2023-2024:Dismantling existing ordinary type tube /choke from fittings and SITC of 1x18W LED pre-wired G13 base with extruded LED Tube poly carbonate body (cool white at 6500 K temperature ) 1200 mm, T8 I, 18 w with nominal system level lumen package of 2100 Lumen having efficacy of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. The light shall be made by Polycarbonate housing (IP20 protection) with minimum 3 KV surge protection. . The light should have minimum 70% of light at 40000 Hr life time as per LM 79 NABL Accreditation certification. LED used in this light should be from manufacturer of Lumileds/Osram/Cree/Nichia make
OD105005/2023-2024:Supply of 1200 mm LED Tube poly carbonate body 1200 mm, T8 I, 1X 18 w with nominal system level lumen package of 2100 Lumen having efficiency of minimum 115 lumen/watt, Inbuilt Driver with THD <10%, power factor >0.95, RoHS compliant, suitable for use 140~280V AC 50 HZ AC supply. etc. The light should have minimum 70% of light at 40000 Hr life time as per relevant NABL Accreditation certification, as required.
OD105009/2023-2024:Supply, conveyance, installation, testing and commissioning of cast aluminum stove enameled elliptical shaped BULK HEAD fittings suitable for B22 LED Bulb, fixed directly on wall including cutting necessary holes, giving connections with the extended original wiring, making good the damages, colour washing etc as required.
OD105011/2023-2024:Supply of 7W /9W LED Bulb suitable for B 22 type holder and 230/240 volt AC 50 Hz power supply( Philips or its Equivalent standard)
90.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
OD105026/2023-2024:Supply of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
1.17.3:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm
1.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.23.1:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.5/6 amps switch
1.23.3:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.15/16 amp switch
1.23.4:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.3 pin 5/6 amp socket outlet
1.23.5:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet
1.23.8:Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.Bell push
1.24.1:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.4:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.24.8:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.Bell push
1.38:Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
OD105038/2023-2024:<<br>Supply and renewing of Piano type Step socket type fan regulator in place of the existing faulty ordinary<br>regulator using mechanized cutting of holes in the existing hylem sheet and giving connections etc as<br>required
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
1.27.4:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mmX75mm)
90.10.1.3:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )3 module moulded plastic box on surface
90.10.1.5:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )6 module moulded plastic box on surface
1.28.2:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.3 Module
1.28.4:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.6 Module
1.28.5:Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required.8 Module
OD105045/2023-2024:Supply 2.5 mfd. Ceiling Fan Capacitor, ISI marked etc as required
OD105062/2023-2024:Supply and replacement of Rubber Shackle and Cotter pin for Ceiling Fan
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
OD105172/2023-2024:SITC of 32, HRC Fuse Base with HRC Fuse link
OD105202/2023-2024:Supply and fixing 20mm normal size 1way terminal rigid PVC junction box with lid etc as required
OD105235/2023-2024:Urgent maintenance of Electrical installation including attending petty repairs , cleaning, of light fittings ,ceiling fan and exhaust fan ,checking all electrical connection in the DB and switch board.
OD105082/2023-2024:Painting letters or figures of the follwing sizes with enamel paint as identfication mark to SB, DB, panel board etc as required
OD105083/2023-2024:Charges for Painting of Panel Board in installed position with one or more coats of paintingwith synthetic enamel paint of approved brand and Colour , including checking all switches , metes, fuses inter connections etc and tightening the connections, attending petty repairs etc., as required(measurement taken by whole sheet area )
OD105106/2023-2024:Charges for dismantling the existing EI, complete, making good the damages of walls and conveying the dismantled materials to section store.
P.Sreekumar P.S.Electricals (BID ID -2035436)
Bidder Name
CALL ON ELECTRICALS
P.Sreekumar P.S.Electricals
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1135150.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .