| 1 | L1₹7.0 LAccepted-AOC AT DUNGAMAL NH 5 POST NB CHILKA VIA BALUGAON DIST KHURDA ORISSA 752037 | KHORDHA | ODISHA | 752037 | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹8.2 L+₹1.2 L (17.1%)Rejected-Finance AT KHARIBANDHA PO BARKUL DIST KHORDHA ODISHA 752030 | KHORDHA | ODISHA | 752030 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹8.6 L+₹1.6 L (22.3%)Rejected-Finance AT AMRITPUR PO NB CHILKA VIA BALUGAON DIST KHURDA ODISHA 752037 | KHORDHA | ODISHA | 752037 | L3 | Rejected-Finance Being L3 |
Tender Value
₹7.2 L
EMD Value
₹14,500
Closing Date
18 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Akhileshwar Kumar IDSE GE
Garrison Engineer (I) (CG) Bhubaneswar Near NTPC Guest House Post Pokhariput Bhubaneswar 751020
COMPREHENSIVE MAINTENANCE OF BR EM AND MISC ITEMS
2020_MES_369305_1
8197/BBSR/06/E8
Open Tender
Miscellaneous Services
Item Rate
180 days
Gopalpur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE (I) (CG) Bhubaneswar
₹14,500
Yes
5 Dec 2020
14 Aug 2020
21 Sept 2020
14 Aug 2020
18 Sept 2020
29 Aug 2020
15 Aug 2020 - 22 Aug 2020
60 days
Amount
SCH 'A' PART-I (BUILDING PORTION) Taking down shutters of any description exc 1.0 Sqm but not exceeding 2.0 Sqm each and removing from site complete all as specified and directed. .
S&F in repairs 150 mm Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified and directed.
S&F in repairs PVC (SWR) pipes110mm single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S&F, solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, in opening as per specification and shown on drg in SSR Part-II 2004 complete all as specified and directed.
S&F, factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails, MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for styles and plain colour PVC sheets for top rails, lock rail and bottom rail on either side & as gap insert for top rail and bottom rail paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the styles and rails with suitable PVC sheet beading and jointed together with solvent cement, in the frame at site as per specification and shown on drawing in SSR Part-II (2004) complete all as specified and directed.
S & F 100 mm Butt hinges medium weight medium cold rolled mild steel complete all as specified and directed.
S&F of 100 mm size aluminium handles cast type anodised complete all as specified and directed.
S&F 150mm long aluminium anodised barrel tower bolts of extruded section complete all as specified and directed.
S&F 150mm long aluminium handle extruded alloy, fabricated type anodised complete all as specified and directed.
S&F stainless steel wire cloth 0.36 mm nominal dia of wire and average width of aperture 1.40 mm fixed with stainless steel wire staples fixed in repair complete all as specified and directed.
M&L for prepartion of old painted wooden surfaces of any description over 10cm width or girth and applying one coat of synthetic enamelled paint complete all as specified and directed.
Hacking out old broken glass (any thickness size quality in description from metal frame including punching or drilling old glazing/springs clips complete all as specified and directed.
M&L 5.50mm thick, plain sheet glass ordinary qualty and glazing with oil putty in square exc 0.50 sqm in each panes complete all as specified and directed.
Demolition of cement concrete in flooring, paving not exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L 40 mm thick plain cement concrete (1:2:4) type B1 finished even and smooth without using extra cement complete all as specified and directed.
M&L 50 mm thick plain cement concrete (1:3:6) type C-1 using 20mm graded stone aggregates as in plinth protection, concrete shall be laid in alternate bays not exc 3.0m in length, finished even and fair complete all as specified and directed.
M&L for 75mm thick cement concrete 1:4:8, type D2 using 40mm graded stone aggregates complete all as specified and directed.
M&L for 40mm thick PCC 1:2:4 type B1 using 20mm graded stone agg as in floors finishing floor even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of old surface and applying one coats of cement base paint complete all as specified and directed.
M&L for preparation of old plastered surfaces and applying one coat of white wash on ceiling complete all as specified and directed.
M&L for preparation of old plastered surfaces and applying one coat of white wash on wall complete all as specified and directed.
M&L for preparation of old plastered surfaces and applying one coats of oil bound distemper on walls complete all as specified and directed.
S&F in repair Chromium plated long body fancy type bib taps with wall flange, cast copper alloy with round operating knob screwed down high pressure, screwed for 15mm bore iron pipe complete all as specified and directed.
S&F for Pillar taps, cast copper alloy, 15 mm with capstan heads, chromium plated, screwed down high pressure, with or without lettered with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in repair 15mm bore stop valve,fancy type chromium plated with long shank and cup (concealed type)screwed both ends (externally threaded) for iron pipe or for union complete all as specified and directed.
S&F in repairs chromium plated shower roses with or without swivel joints, any size, including fixing to steel pipe or union complete all as specified and directed.
Cleaning and removing of tank exe 250 & n.exe 500 all scale and dirt etc from tank and from the mouth circulating pipes etc complete all as specified and directed.
All as per item No 27.00 hereinbefore but exc 500 lit n.exc 1000 liter
All as per item No 27.00 hereinbefore but exc 1000 lit n.exc 2000 liter
Taking down 20mm bore PPR water pipe with all fitting fixed complete to walls and ceiling or laid on floors complete all as specified and directed.
S&F in repair PVC over head water tank cover (ISI Marked) ,for 500/ 1000 ltr capacity water tank of approved make complete all as specified and directed.
S&F in repairs 20mm outer dia PP-R(Polypopylene random copolymer) three layer pipes SDR 7.4 & SDR 11 UV stablised and anti microbial fusion welded having thermal stability for hot and cold water supply including PP-R plain and brass threaded polypropylene random fittins complete concealed to wall and ceiling or laid in floors including testing etc complete all as specified and directed. (Note: The unit rate shall include the cost of short length with all pipe fittins and fixing accessories such as pipe hooks, screw, clamps etc.
S&F in repair vitreous china wash basin, angle back, size (550x400)mm including bracket, PVC waste pipe, chromium plated coupling 32mm and Pillar tape fancy type cast copper alloy chromium plated, 450mm long PVC connection etc complete all as specified and directed.
S&F in repairs 32 mm Waste coupling of PTMT(half or full threaded) (Minimum weight 32mm-45gms/40mm-60 gms) complete all as specified and directed.
S&F in repairs PVC Waste pipes 32 mm in size flexible for use in kitchen sink, WHB of approved make complete all as specified and directed.
S&F, vitreous china pedastal type water closet, white (excluding flushing cistern and flush pipe) but including connection to trap, and to flushing pipe, anti-syphonage pipe etc complete and making good to floor complete all as specified and directed.
S&F in repairs PVC low level flushing cistern, 10 litre capacity, symphonic action type, white inlet valve, float, handle, 20/25mm PVC connection 450mm long, 15mm cast copper alloy chromium plated stop valve and 32mm dia PVC & flushing pipe complete all as specified and directed.
S&F in repair, 450mm long, 15mm dia, PVC connection pipe, with brass unions on both ends, complete all as specified and directed.
S&F in repair ball brass valves,high pressure,with polythene float and flynut complete for 15 mm bore pipe,screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S&F MS holdfast of flat iron 25x3 conforming to Fe 290 Gde E-165 complete all as specified and directed.
Plain cement concrete (1:3:6) type CI using 20mm graded stone aggregate as in hold fasts complete all as specified and directed.
MISC ITEMS (BUILDING PORTION) Demolition of cement concrete (un-reinforced) in ground floors and paving n.exc 15cm thick (below or above ground level) complete all as specified and directed.
M&L for 100 mm thick cement concrete 1:4:8, type D2 using 40mm graded stone aggregates complete all as specified and directed.
M&L Machine pressed precast concrete interlocking paver block M-35 Grade 60mm thick, any shape and size in conforming to IS-15658-2006 Toping with white cement with pigment and glossy, Pattern & shape complete all as specified and directed.
M&L 50 mm thick sand cushion under interlocking paver tiles including watering and consolidation complete all as specified and directed.
M&L for preparation of old painted steel surfaces of any description over 10 cm width or grith and applying one coat of synthetic enamelled paint complete all as specified and directed.
Taking out carefully Precast RCC cover slab of septic tank excavating and taking out sludge including foul water in a closed container by mechanical process or manual process transporting to a distance exc 250 m but not exc 500 m and depositing the same in excavated earthen pit of suffiecent size and depth in any type of soil within the defence land, where directed to a distance exc 250m and n.exc. 500m returning, filling in earth into excavated pit after every disposal of sludge cleaning inspection pit, sludge chember inlet and outlet pipe cleaning MS rungs etc complete for septic tank capacity from 25 user to 500 users cleaning the septic tank with fresh water complete all as specified and directed.
Taking out carefully the cover slab of each manhole of depth from 1.0 metre to 2.00 metre and removing the sludge by mechanical process or manual process transporting to a distance exc 250 m but not exc 500 m and depositing the same in excavated earthen pit of sufficient size and depth of any type of soil within the defence land, where directed including returning, filling of earth in excavated pit after every disposal of sludge etc. and cleaning with fresh water, placing the cover slab in position complete all as specified and directed.
Cleaning/removal of blockage from Nahani trap, floor trap, gully trap, IWC, EWC including CI or/ UPVC pipe or any other type of pipe including its junction to out side of wall complete all as specified and directed.
Taking out carefully the cover slab of gulley traps of any size and shape ,depth and clearing the blockage by removing the sludge/any material to a distance exc. 250m and n.exc. 500m and cleaning with fresh water placing the cover slab / Grating in position complete all as specified and directed.
Cleaning of blockage sewage line manually and then with fresh water of pipe 100 mm dia / 150 mm dia or above in between man holes and passing rubber ball of suitable size through line to ensure all blockage perfectly clear to the entire satisfaction of Engineer-in-Charge complete all as specified and directed.
SCH 'A' PART-II (E/M PORTION) Taking down carefully by unscrewing from boards/outlet boxes,fittings and fixture such as switchs, socket, ceilling roses, lamp holder, brackets,ceilling fittings, bulk head fittings, light fittings etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately and and making good the disturbed surface of ealls, floor,etc complete all as specified and directed.
M&L in Repair/ Replacement of switch piano 5 Amp flush type one way single pole 230 Votls, 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
M&L in Repair/ Replacement celing rose surface backlite with 2-3 terminal 65x30mm 230 Votls, 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
M&L in replacement switch socket combination 5 Amp flush type 2 in 1 type, 3 pin, flush type 230 volt 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
M&L in replacement switch socket combination 5/16 Amps flush type universal 5 in 1 type, 5 pin, flush type 230 volt 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S & F for replacement Ding Dong type Bell, AC, 230V,50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S & F for replacement switch bell/Buzzer push,flush type 5 Amp, 230Volt, 50 Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
S&F for repaclement stepped type electronic fan regulator stepped socket type ,100W ,230V ,50Hz, AC complete all as specified and directed. ( Make - Anchor/ Havells or Equivalant)
M&L in repairs for Capacitor for ceilling fan 2.5 Mµ suitable for 1200 mm sweep complete all as specified and directed. ( Make - Bajaj / Crompton or Equivalant)
M&L in repairs Capacitor for Exhaust fan 4 Mµ suitable for 230 mm sweep complete all as specified and directed. ( Make - Bajaj / Crompton or Equivalant)
Taking down ceiling / Exhaust fan, sealing cable end, dismantling blades and removing fan and blades for repair and rewinding refixing the same complete all as specified and directed.
Material and labour for rewinding of ceiling fan of1200 mm sweep including taking down after re-winding, oiling, greasing and re-fixing complete all as specified and directed.
All as per Item No. 63.00 hereinbefore but for one exhaust fan of sweep 300 / 450 mm Sweep complete all as specified and directed.
S & F in replacement Bush / Ball bearing (type - Single row deep groove ball bearing) for ceiling fan 1200mm sweep bearing no -6201/ 6202 or as per sample complete all as specified and directed. (Make - TATA / SKF)
S & F in replacement of MCB SP 6 to 32 Amp, 10 Ka, C series , 230 Volts, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand).
S & F in replacement of MCB SPN 6 to 32 Amps, 10 Ka C series, 230 Volts, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand)
S & F in replacement of MCB TPN 10 Ka "C" series 415 Volt 40 to 63 Amps, AC complete all as specified and directed. (Make - Havells / L&T/ Legrand)
S & F for Pride Plus Spectra in 2000 lm in a compact batten (57.5 cm), decorative mushroom profile LeD lighting fitting of Cap 20Watt 6500K with extruded aluminium channel, environmental friendly, energy efficient including twin core twisted flexiable copper conductor cable of size 1 sq mm from connector to ceilling rose complete all as specified and directed. (Make:- Havells Cat No:- LHEXARP7IN1W020 or Equivalant / Crompton /Phillips / Bajaj/)
S&F for E-lite LED Pride plus Neo Decorative ultra slim square profile 10W LED 6500K LED lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready including twin core twisted flexiable copper conductor cable of size 1 sqmm from connector to ceilling rose complete all as specified and directed. (Make:- Havells Cat Part No. LHEXACP7IN1W010 or equivalent in Crompton / Bajaj/Phillps)
S&F for E-lite LED Pride plus Neo Decorative ultra slim square profile 5 W LED 6500K LeD lighting fixture with extruded polycarbonate, environmental friendly, energy efficient ready including twin core twisted flexiable copper conductor cable of size 1 sqmm from connector to ceilling rose complete all as specified and directed. Make:- Havells Cat Part No. LHEXBTP7IN1W005 or equivalent in Crompton / Bajaj/Phillps)
S&F for Endura cItylIte platinum plus sl 45W LED 757PASYTOPC energy saving and environmental friendly long life 35 Watt LED street light made up of pressure die cast aluminium housing with high power led as lighting source and lens embedded PC cover having iP65 protection and impact resistance of iK07 with 10KV Built-in surge Protection device including twin core flexiable copper conductor cable of size 1.5 sq mm from connector to light point complete all as specified and directed. Make:- Havells Code No:- HSN 9405 or equivalent in Crompton / Bajaj/Phillps)
Taking down of Street light fitting complete of Cap 35 / 40 Watt LED street light including repair and replacement of Electronic Driver as per required and refixing the same existing position complete all as specified and directed.
Supply and Laying inreplacement of XLPE LT UG cable PVC insulated , bedded armoured heavy duty electric cable 1100 volts grade with aluminum conductor of 25 Sq mm 3.5 core in trenches or fixed on wall/floor/poles complete all as specified and directed.
Excavation in trenches in soft/loose soil n.exc 1.5m wide and n. exc 1.5m depth getting out of soil for taking out or laying of pipe line etc complete all as specified and directedfor laying of cable, errection of poles, stay and pipe line, complete all as specified and directed.
Returning & filling including spreading, leveling watering and well ramming in layers n. exc 25 cm thick in any type of soil complete all as specified and directed.
Removal of surplus soil to a distance n. exc 50 m above the starting point complete all as specified and directed.
M & L for sand filling with clean dry fine sand unwashed including gently punning around cables in trenches for cable protection complete all as specified and directed.
Supplying & Laying Sub Class `B’ bricks, old size, kiln burnt, laid with axis of brick perpendicular to the axis of the cable, for protection of cable complete all as specified and directed.
Supply and fixing in replacement of MCCB 3 pole , 200 amp rating of 35 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. ( Make : Legrand or equivalent in ABB/Schnieder)
Taking up/down GI tubing from trenches , duct, wall, roof or in any position with all fittings for re-laying /refixing of serviceable pipes and removing the unserviceable pipes for 50 mm dia complete all as specified and directed.
All as per item No 81.00 hereinbefore but 25 sqmm dia complete all as specified and directed.
Supply and fixing in replacement of GI tubing medium grade of 25 mm dia fixed on wall/floor etc complete with necessary clamp, nut, bolts and washers and socket and making good the disturbed surface of wall , floor or roof etc complete all as specified and directed.
All as per item No 83.00 hereinbefore but 50 sqmm dia complete all as specified and directed.
Supply and fix Valves, Sluice, flanged of class 1.6 PN ,80 mm (3”)dia complete all as specified and directed.
Supply and fix Gun-metal, globe or gate valves 50 mm dia,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix Gun-metal, globe or gate valves 25 mm dia,with iron wheelhead, screwed both ends for iron pipe and fixed complete all as specified and directed.
Supply and fix Non Return Sluice Valve 50 mm dia of class 1.6 PN complete all as specified and directed.
Re-laying old serviceable GI tubing after throughly cleaned the inside of pipes and re-running the old screws threads as required and re-fixed/re-laying in trenches wall or roof etc complete for 50 mm dia complete all as specified and directed.
All as per item No 89.00 hereinbefore but 25 sqmm dia complete all as specified and directed.
Servicing of authorised agency "B" check in replacement of Lube oil(15W40). fuel filter, Oil filters, Coolant top up will be done. Under 'C' Check " B- Check activities will be done along with Air filters replacement,Tapped set replacement if required (Opening, adjusting, tightening of tappet cover complete by torque wrench by applying proper pressure , cleaning of complete sump from sludge of dirt, oil) etc and refitting for DG set including drain out (used) engine oil and filling new engine oil of Capacity 62.5 KVA Gen Set complete all as specified and directed. Note:- (a) Engine oil, Air Filter, Fuel Filter, Oil Filter to be measured and paid separately as supply only under respective items of schedule 'A'.
Supply only engine oil suitable for diesel generator set (Oil 15W/40) complete all as specified and directed. Make: Servo/ HP / Bharat Petroleum.
Supply only coolant suitable for radiater of DG sets complete all as specified and directed. Make: HP/TVS or Equivalent.
S&F in replacement of battery terminal brass(heavy duty)with nuts & bolts for battery (as per sample) complete all as specified and directed.
S&F Fuel Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
S&F Oil Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
S&F Air Filter as per sample as required at site complete all as specified and directed. Make:- Greaves, TVS or Equivalent.
Repair / Replacement of Self Starter 24 volts/12 volts DC, disconnecting and dismantling and repairing with replacement of bendex-01,Rewinding of armature, Field coil, Carbon Bush etc reassembling and refitted at its original position including testing of the complete self starter of Capacity 62.5 KVA Gen Set complete all as specified and directed.
Supply, heating and topping up transformer insulating oil EHV grade having dielectric strength not less than 60 KV (R.M.S) at 2.5 mm gap high viscosity confirming to IS – 335 of 1983 complete for replacement of unserviceable transformer oil or for toping up complete all as specified and directed.
M&L for complete routine test of transformer of Cap 160 KVA (as per IE rules) with authorised agency once in 6 month as per the dirction of Engr-in-Charge and submit the all routine test certificate by the authorised agency to Engr-in-Charge for maint of our record of any cpacity of trnasformer complete all as specified and directed.
Supply and Replacement of fresh silica Gel complete all as specified and directed.
S & F in replacement of electronic balast suitable for 28 T-5 Watt complete all as specified and directed. (Make :-Crompton Greaves/Phillips/Bajaj/)
Cleaning ,servicing ,painting ,writing SM.MES No including minor repair work if required and greasing of all moving parts i.e pump impeller , stainless steel shaft, bearing & rubber coppling etc for smooth running and replacement of packing gaskets, shaft sleeve, neck ringnut bolts and washers etc, with necessary oiling and greassing of 12.5 HP pump complete all as specified and directed.
Supply only ball bearing 6310-ZZ/C3 complete all as specified and directed. Make:- (SKF, TATA)
Supply only ball bearing 6206-ZZ complete all as specified and directed. Make:- (SKF, TATA)
Cleaning and removing yearly all scales and deposited materials in Under ground water sump of 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and directed. Note :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
Cleaning and removing yearly all scales and deposited materials in Overhead tank 50000 liters capacity by applying bleaching powder , brushes for removing deposited materials, including jungle cleaning to sourrounding area including draining out existing water complete all as specified and directed. NOTE :- The cost of coir rope, bleaching powder, brush for removing scales & cleaning the surrounding area near tank and dumping the mud utside the premises shall be deemed to include in the above item rate.
M&L in replacement of Brass Foot Valve for suitable of 50 mm dai GI Tube complete all as specified and directed.
M&L for repair, cleaning and servicing of automatic star delta starter of capacity 15 HP fixed in existing LT panel including tightening of all loose coonection and replacement of minor defective parts such as cable lugs, nut bolts PVC copper connection wire etc to make the starter serviceable complete all as specified and directed. (NOTE : Major defective parts will be measured and paid seperetely under relevent item as supply only)
S & F in replacement of floursent tublar lamp 28 T-5 watt complete all as specified and directed. (Make : Crompton Greaves/Phillips/Bajaj/)
Supply and fixing in replacement of MCCB 3 pole , 100amp rating of 16 KA on existing LT panel board including dismantling and taking out of old unserviceable MCCB from the LT panel board complete all as specified and directed. ( Make : Legrand or equivalent in ABB/Schnieder)
SUBAL CHARAN PRADHAN
PRADIPTA KUMAR PANI
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .