Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹45.1 L
EMD Value
₹45,100
Closing Date
12 Nov 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
building Department, Bhavnagar Municipal Corporation, Sir Mangalsinhji Road, Kalanala, Bhavnagar - 364001
Proposed Renovation & Repairing work at Akwadakendravati School, Ward No-13 (Ghogha Circle- Akwada), Bhavnagar
356700
BUILDING/ AKAWADA KENDRAVATI SCHOOL /2026-27
Open
Civil Works - Buildings
Works
Bhavnagar
8 documents required · 8 mandatory
₹2,400
commissioner of bhavnagar municipal corporation
₹45,100
19 Oct 2026
19 Oct 2026
19 Oct 2026
12 Nov 2026
19 Oct 2026
Excavation for foundation upto 1.5 m depth including
sorting out and stacking of useful materials and disposing
off the excavated stuff upto 50 Meter lead.(A) Loose or
Govt. R&B / SOR - 2024- 25 / item code -04001A
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles)
and getting out the soil and disposal of the surplus excavated
soil as directed within a lead of 50 Meter for following diameter of
pipes.(iii) 300 mm
Govt. R&B / SOR - 2024- 25 / item code -04010C
Extra for under reaming inside the bore Holes for under reamed
piles of following Diameter.(iii) 300 mm
Govt. R&B / SOR - 2024- 25 / item code -04011C
Providing and laying cement concrete 1:2:4 (1- Cement : 2-
Coarse sand : 4- graded stone aggregates 20 mm
nominal size) and curing complete including cost of
formwork in (A) Foundation and Plinth (upto 10 ton)
Providing and laying controlled cement concrete M.250
and curing complete including the cost of form work but
5 excluding the cost of reinforcement reinforced concrete 11.00 4616.00 Cum
work in (A) Foundations, footings, Base of columns and
Mass concrete. (upto 10 ton)
Providing laying controlled cement concrete M-250 and
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in GROUND BEAMS / PLINTH BEAMS
Providing laying controlled cement concrete M-250 and
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in COLUMN UP TO FIRST FLOOR
Providing laying controlled cement concrete M-250 and
curing complete including the cost of form work but
excluding the cost of reinforcement for reinforced concrete
work in COPPING FOR ALL LEVEL
Providing TMT Bar FE 500D reinforcement for R.C.C.
9 work including bending, binding and placing in position 11431.00 76.52 Kg
complete upto floor two level
Govt. R&B / SOR - 2024- 25 / item code -05014C
Brick work using common burnt clay building bricks having
crushing strength not less than 35 kg./Sq.Cm. in
foundation and plinth in Cement Mortar 1:6 (1- Cement :
-fine sand)(B) Conventional for Ground Level
Filling available excavated earth (excluding rock) in
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each disposited
layer by ramming and watering.
Govt. R&B / SOR - 2024- 25 / item code -4006
filling available excavated earth (excluding rock) in
trenches. plinth, sides of foundations etc. in layers not
exceeding 20 cm. in depth consolidating each disposited
layer by ramming and watering.
Govt. R&B / SOR - 2024- 25 / item code -17009
Providing and fixing 0.60 metre high fencing with
metre long M.S. Angle (Y type Fabricated/ instruction
given by engineer/) posts 50mm. X 50mm. X 6mm. And oil
painting 3 coats fixed at 2.5 mt. C/c with 4(Four) horizontal
Circle of 450mm dia of Razer Blade wire wighing
1.20Kg/Rmt, strai
Dismentling barbed wire in fencing including making rolls
and also including dismentling fencing posts including all
earth work concrete in base and making good the
disturbed ground stacking useful materials as directed and
disposing as directed and disposing of the unserviceable
materials with all lead and lift.
Govt. R&B / SOR - 2024- 25 / item code -20014
Providing and Fixing Main Gate/ safetygrill, for windows,
ventilations, doors/Railing for staircase and Remp, front
and side elevation fins of required patern for windows/
Door/ staircase and Remp using M.S.polished bars& C.I.
15 MOULD PIPES size12mmm flat and rectangular / round 2427.00 130.00 Kg
M.S.pipes of required size at required spac in gasper
design with one coat of primer and two coats of matt
finished oil painting directed by architect and hold fastwith
coach bolts etc. complete.
Demolition of Brick work and stone masonry including
stacking of serviceable materilas and disposal of
unserviceable materials with all lead and lift.(ii) In Cement
Govt. R&B / SOR - 2024- 25 / item code -20003B
Providing erecting and fixing double coated ISI water tank
17 of required capacity each with all necessary fittings and 1000.00 3.91 litre
connection etc. complete on terrace
Govt. R&B / SOR - 2024- 25 / item code -22014
Demolition including stacking of serviceable materilas and
18 disposal of unserviceable materials with all lead and lift. (i) 11.00 1097.15 cu.m
Govt. R&B / SOR - 2024- 25 / item code -20002
Providing & erecting Approved make Ceiling Fan with
double ball bearing ISI mark with condenser A.C.230V
19 50c/s. 1400 mm. sweep complete, canopy erected on 52.00 1738.21 Each
existing hook or clamp with earthing [ Make shall be
approved by Engineer in Charge]
Providing and fixing pre-cast Rubber Dye / steel Dye inter
locking concrete block 60mm thick with grade of concrete
M300 pnumatic compressed / vibrated mechanically and
20 as per approved design Confirming to IS 15658 : 2006 852.00 700.54 Sqm
including 35 mm Sand layer for levelling and filling the
joint with sand in proper line and level as per guidlines of
IRC : SP 63-2018 etc. Complete.
Govt. R&B / SOR - 2024- 25 / item code -14033
Removing the installed Ceiling fan / Exhaust Fan for
21 servicing / repairing from ceiling and reinstalling the same 15.00 50.00 Each
after making in working condition.
5-6.2 R & B Electric Sor
Replacing approved make fan regulator
22 resistance type for Ceiling fan (credit of 7.00 105.00 Each
D.M. retained by Agency.)
5-6.10 R & B Electric Sor
Supplying and erecting LED indoor fittings with LEDs of
wattage 16-20 watts assembled on single MCPCB, with
housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die
cast powder coated and high U.V. & corrosion resistance
with diffuser housed in aluminium casted body with
23 company mark/name 160V to 270V,Power Factor more 60.00 528.23 Nos
than 0.95, THD < 15 % CCT 3000 K to 6500K, Luminaire
efficacy> 85 lumens/watt , LED driver efficiency > 85 % (
fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.)
(iii) 16-20 watts, Surge-2 KV SOR 2.15.9
Approved make ELCBs / RCCBs conforming to IS:
and having sensitivity of 30 mA and Short Circuit
withstand capacity of 6 KA and suitable for operation on
24 single phase 240 V. having characteristic of quick action & 3.00 1822.04 Nos
tripping with all advance feature & do not incorporate any
electronic component. for following Max. rating erected as
directed (ii) 40Amps. DP Cat. III
Miniature circuit breaker single pole 6A to 32A suitable to
operate on 240 V A.C. system and having breaking
capacity 10 KA to be erected in existing box. confirming to
IS 8828/1996 with ISI Mark Cat.III
SOR 3.10.1 (b) cat III
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected in / on wall / ceiling with 2.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size(a) with medium
class Rigid PVC pipe and accessories(a) 2 wire 4 sq. mm
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (a) with
medium class Rigid PVC pipe and accessories(b) 2 wire
Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe
to be erected concealed in /flushed on wall/ceiling, with
1.5 sq. mm copper
conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size (a) with
medium class Rigid PVC pipe and accessories(a) 2 wire
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
29 or ceiling erected with necessary PVC fittings & Junction 10.00 32.32 Rmt
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (b) 25 mm
SOR 1.3.2 (b) cat III
Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall
30 or ceiling erected with necessary PVC fittings & Junction 8.00 52.52 Rmt
boxes fixed with adhesive solution & Clamps with following
dia of pipes, in approved manner as directed (b) 32 mm
SOR 1.3.2 (c) cat III
Point wiring for Looped Plug with 6A Modular type switch
& 5 pin socket erected on PVC / Metallic box, single
31 mounting base frame covered with textured / metallic front 3.00 241.39 Nos
plate modules erected on / in wall / ceiling with following
type accessoriesCat. III
SOR 1.2.4 (a) cat III
Point wiring for Light / Bell with 2-1.5 sq.mm & earthwire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multistrand copper wires, in following
type of pipe to be erected concealed in/ on surface on
wall/ceiling complete with 6A Modular type switch / bell
push & accessories and earth continuity of following type,
erected on PVC / Metallic box, single mounting base
frame covered with textured/metallic front plate modules
erected on / in wall / ceiling as per pipe erected, with
necessary Lamp holder/ceiling rose / H.D.Connector as
directed.(a) with medium class Rigid PVC pipe and
accessories Cat. III
SOR 1.2.1 (a) cat III
Point wiring for FAN with 2-1.5 sq.mm & earthwire of
sq.mm (Green) both are of .ISI marked 1.1 KV Grade
FRLS PVC insulated multistrand copper wires, in following
type of pipe to be erected concealed in / flushed on
wall/ceiling complete with 6A Modular type switch and
hum free EME four or more step type electronic fan
33 regulator with separately mounted and accessories with 32.00 598.93 pt
earth continuity of following type erected on PVC / Metallic
box, single mounting base frame covered with
textured/metallic front plate modules erected on / in wall /
ceiling as per pipe erected. with necessary ceiling rose /
H.D.Connector as directed.(a) with medium class Rigid
PVC pipe and accessoriesCat. III
SOR 1.2.2 (a) cat III
Point wiring for Individual Plug with & earthwire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in following type
of to be erected concealed in / on surface of wall / ceiling
complete with Modular type switch & 5 pin Plug erected on
PVC / Metallic box covered with appropriate front plate
modules erected on / in wall / ceiling as per pipe erected
with following type of accessories.[I] For 6A Plug with 2-
1.5 sq.mm Cu. Wire(a) with medium class Rigid PVC pipe
and accessoriesCat. III
SOR 1.2.3 (a) cat III
Supplying & erecting earth pit of minimum bore
dia.150mm size approved make Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free G.I.Pipes having Outer pipe dia of
50mm having 80-200 Micron galvanising, Inner pipe dia of
25 mm having 200-250 Micron galvanising, connection
35 terminal dia of 12mm with constant ohmic value 1.00 4591.46 NOS
surrounded by highly conductive compound with high
charge dissipation suitable for following type of
applications. (b)For Electrical installation up to 11 KV in
Length of Pipe : 100 mtrs Back filling Compound :1 no.
Providing and fixing window having extruded aluminum
Colour Powder Coated section frame main outer size
95mm x 24mm x 1.17mm @ wt.of 0.738 Kg/mt, horizontal
Three track member size 92mm x 31.75mm x 1.30mm @
Wt.1.07 Kg/mt, vertical member of size 92mm x 31.75mm
x 1.50mm ,@ Wt. 1.06 Kg/mt with sliding shutters of
horizontal member size 40mmx18mm x1.29mm @ wt.of
0.456 Kg/mt, vertical member of size 40mm x 18mm x
1.29 mm @ wt.of 0.456Kg/mt with 5 mm thick transparent
bronze colour tinted float glass with powder coated
aluminum fittings and fixtures and transparent silicon
sealant glass fixing to frame as per details etc
Govt. R&B / SOR - 2024- 25 / item code -11033
Providing and laying broken chine mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of glazed
tiles to be laid over cement mortar 1:3 to plain or slope
37 and to be tempered to bring mortar creme out upto 35.00 771.98 Sqm
surface using white cement including rounding off
junctions and extending them upto 15 cm along the
wall,clearing with water and oxalic acid etc. as directed.
Govt. R&B /SOR - 2024- 25 item code -
Providing and laying polished kota stone slab 25mm thick
in risers of steps,skirting Dedo and pillars laid on 10mm
thick cement mortar 1:3 (1-Cement : 3 coarse sand) and
jointed with gray cement slury mixed with pigment to
match the shade of slab including rubbing and polishing
Govt. R&B / SOR - 2024- 25 / item code -14013A
Steel work, welded in built up sections framed work
including cutting, hoisting, fixing in position and applying a
priming coat of red lead paint. (A)In beams and joists,
39 channels angles Tees, flats, with connecting plates or 5.00 9018.30 q
angle cleats as in main and cross beams. Hip and jack
rafters, purlins conneted to common
rafters and the like
Govt. R&B / SOR - 2024- 25 / item code -11002AA
Providing and fixing screw down bib taps of following
size.(B) Brass chromium plated screws down Bib Tap.(i)
15mm dia. (As Instructed and Selected byEngineer
Govt. R&B / SOR - 2024- 25 / item code -23028B1
Providing and fixing screw down bib taps of following
size.(B) Brass chromium plated screws down Bib Tap.(As
Instructed and Selected byEngineer incharg.)
Govt. R&B / SOR - 2024- 25 / item code -23028B2
Providing and fixing Gun metal check or non-return fullway
42 wheel valve.(A) 15mm dia.(As Instructed and Selected 2.00 184.98 Each
byEngineer incharg.)
Govt. R&B / SOR - 2024- 25 / item code -23031A
Providing and fixing Gun metal check or non-returnfullway
43 wheel valve.(B) 20mm dia.(As Instructed and Selected 4.00 201.80 Each
byEngineer incharg.)
Govt. R&B / SOR - 2024- 25 / item code -23031B
Providing and applying cementitious waterproofing
treatment in two coats using approved materials such as
Dr. Fixit LW+, Sika, or Fosroc Brushbond, over thoroughly
cleaned concrete surfaces. includes complete surface
44 preparation by wire brushing and removal of loose 52.00 672.13 Sqm
particles, algae, and laitance; crack filling using polymer-
modified mortar; and application of two coats of
waterproof slurry, followed by proper curing.
Providing and fixing S.W.R. pvc pipe for soil and waste
water including necessary fittings like band, door bend, Y,
Tee, Cowel, in floor and wall of approved make like
ASTRAL, Finolex or Supreme complete. (A) 110 mm.
Providing and fixing S.W.R. pvc pipe for soil and waste
water including necessary fittings like band, door bend, Y,
Tee, Cowel, in floor and wall of approved make like
ASTRAL, Finolex or Supreme complete. (A) 75 mm.
Providing, laying and jointing in true line and level
diametre U.P.V.C (Type B) conforming to IS 13592-1992
with one end plain and other end socketed with rubber
ring, & fittings conforming to ISI 14735-1999 of approved
make for drainage system pipe line, pipe shall be jointed
with each other with rubber lubricant, pipe shall be fixed
on wall using of PVC clamp of the size 110 mm diametre x
149 mm length x 145 mm heigh at every 2000 mm center
to center or shall be concealed in walls as directed
including necessary fittings such as bends, shoes etc.
including testing of pipes and joints and jointed with
adhesive solvent cement including cost of all materials.
Govt. R&B / SOR - 2024- 25 / item code -23067
Providing and fixing PVC SWR Nahni trap IS 14735 for
drain - 75 mm diameter with jali of the following nominal
48 diameter of self cleansing design with C.I scread down or 2.00 582.44 Each
hinged grating including the cost of cutting and making
good the walls.
Govt. R&B / SOR - 2024- 25 / item code -23069
Providing laying and jointing in true line and level 25mm
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
Govt. R&B / SOR - 2024- 25 / item code -23062
Providing laying and jointing in true line and level 40mm
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
Govt. R&B / SOR - 2024- 25 / item code -23064
Providing laying and jointing in true line and level 50mm
dia. U.P.V.C. Pipe ( SCH- 40) for cold water including
fittings as approved by Engineer In Charge. Pipe shall be
fixed on the wall with the help of clamp at every two metre
C/C or shall be concealed as directed including necessary
fittings etc. including testing of pipe and joints and fixing
the same with adhesive solvent, including cost of all
Govt. R&B / SOR - 2024- 25 / item code -23065
Filling in foundation and plinth with murrum or selected
52 soil in layers of 20cm. thickness including watering, 68.00 301.58 cu.m
ramming and consolidating etc. complete.
Govt. R&B / SOR - 2024- 25 / item code -04008A
Providing and fixing pre-cast concrete kerb stone of gray
cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine sand)
Govt. R&B / SOR - 2024- 25 / item code -14023A
Applying two coats of putty & two coats of primer of
approved brand and manufacture on new wall surface to
54 give an even shade including thoroughly brushing the 145.00 40.19 sqm
surface free from mortar dropping and other foreign matter
and sand papered smooth.
Govt. R&B / SOR - 2024- 25 / item code -9032
Wall painting (two coats) with plastic emulsion paint of
approved brand and manufacture on undecorated wall
55 surface to give an even shade including throughly 145.00 83.98 sqm
brushing the surface free from mortar droppings and other
foreign matter and sand papered smooth.
Govt. R&B / SOR - 2024- 25 / item code -18031
Finishing wall with weather proof exterior emulsion paint
(Including weather proof priming coat) on wall surface (two
56 coats) to give an required shape even shade after 550.00 161.00 sqm
thoroughly brushing the surface to remove all dirt, and
remains of loose powdered materials.etc complete
Supplying, fabricating, and fixing MS cupboard door
(shutter type), wall-mounted, with powder-coated finish,
57 including hinges, locking arrangement, holdfasts, painting, 6225.00 130.00 Kg
and complete fixing in wall using proper anchor fasteners.
Filling in plinth with sand under floors includingwatering
ramming, consolidating and dressing complete
Govt. R&B / SOR - 2024- 25 / item code -04007A
59 8=[S8Z v 8=M,L EF0[ VF5JFG]\ SFDP 1.00 1800.00 DAY
Road Dept annual rate 2024-25 item no 57 without gst
0L5F8"D[g8 SFD DF8[ 5]Z]QF DH]Z A[,NFZ
5]ZF 5F0JFG]\ કામ
Road Dept annual rate 2024-25 item no 65 without gst
0L5F8"D[g8 SFD DF8[ :+L DH]Z 8M5,F 5]ZF
Road Dept annual rate 2024-25 item no 66 without gst
H[P;LPALP ,M0ZqV[1SJ[8Z EF0[ VF5JFG]\
Road Dept annual rate 2024-25 item no 59 without gst
Total work Amount
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1.nit akwada kendrawati school.pdf
2.SBD.pdf
3. Item Specification.pdf
4 Civil Specification.pdf
5. Electric Specification.pdf
6. INTRODUCTION OF FORM.pdf
7. Material Testing Schedule.pdf
12.Paripatra_compressed.pdf
9. BUILDING_SPECIFICATIONS_compressed.pdf
10.BOQ.pdf
11.COMPOUND WALL PILE-Model FOR AKWADA KENDRAVARTI SCHOOL.pdf
12.vendor list.pdf
13.CONTR AGENCY 10 PENELTY.pdf
CHECK LSIT.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .