Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹74.2 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹76.7 L+₹2.5 L (3.36%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹81.2 L+₹7.0 L (9.44%)Rejected-Finance | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹1.0 Cr+₹29.4 L (39.6%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹1.2 Cr+₹45.0 L (60.6%)Rejected-Finance D NO 37 8 1 MANCHUKONDA GARDENS INDUSTRIAL ESTATE VISAKHAPATNAM 530007 | VISAKHAPATANAM | ANDHRA PRADESH | 530007 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹1.3 Cr
EMD Value
₹2.1 L
Closing Date
1 Sept 2022, 6:00 pmClosed
GE (I) (DM)
GARRISON ENGINEER I DOCKYARD MAINT NAVAL DOCKYARD VISAKHAPATNAM 530 014
REPLACEMENT OF DEFECTIVE LIGHT, REPAIR AND MAINT OF LT PANEL BOARD METERING EQUIPMENT, SWITCH GEARS, DAY TO DAY MAINT OF 11 KV DISTRIBUTION CABLES, ATTENDING COMPLAINT AND REPLACEMENT OF UNSV UG CABLE GALLERY EARTHING, EARTHING STRIPS ALL ALLIED WORK
2022_MES_535942_1
SSGE/8730/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
NAVAL DOCKYARD VISAKHAPATNAM
As per tender documents
8 documents required · 8 mandatory
₹1,000
GE (I) (DM) VISAKHAPATNAM
₹2.1 L
Yes
30 Dec 2022
5 Jul 2022
8 Sept 2022
5 Jul 2022
1 Sept 2022
25 Aug 2022
Amount
Servicing/maintinance of multiple section of LT Panel board in substation comprising up to total 05 Nos of accessories like ACBs/ MCCBs/SDFs, busbar chamber, swich gear chamber, metering chamber cable termination/tray chamber after opening front /top / side / back cover by using forced air pressure and brushes, cleaning of all dust/durt, complete cleaning of out side surface of panel board using suitable cleaning agents, tighting of all nuts & bolts of busbar / switchgear / cable terminals, repair / replacement to defective metering wiring from ACB / MCCB / CT to meter and replacement of defective meters, CTs, indicator lamp, metering terminal blocks, MCB, replacement of defective aluminum cable lugs, nuts-bolts-washers, replacement of defective Panel knob/door knob and hinges complete all as specified and as directed Note:- (i) Panel Meter, indicator lamp, ACB, MCCB, busbar, SDF, HRC and CT will be measured and paid seperately as supply only measured and paid seperatelly under respective items in this schedule. . (ii) required aluminium cable lugs, busbar insulators, metering cables and nuts-bolts-washers shall be inclusive of quoted rate. (iii) Servicing / maintinance of ACBs measured and paid seperatelly under respective items in this schedule.
All as per item No 1.00 above but comprising ACBs /MCCBs/SDFs total 6 to 10 Nos
All as per item No 1.00 above but comprising ACBs /MCCBs/SDFs total 11 to15 Nos
All as per item No 1.00 above but comprising ACBs /MCCBs/SDFs total 16 to 20 Nos
All as per item No 1.00 above but comprising ACBs /MCCBs/SDFs total 21 to 25 Nos
Supply only indication lamps (LED type) red, yellow and blue in colours of 22.5 mm dia to monitor on LT panel board suitable for 240 V AC supply and taking down unserviceable indication lamps complete all as specified and directed. Cat Part No:-1SFA619402R5201 Make:-Siemens/C&S/schneider/ABB
Supply only metering current transformer of 1000/5 Amps class-1, 15 VA, complete all as specified and directed by Engr-in-charge. Make:-Rishabh or equivelent of Kappa/ AE
Supply only metering current transformer of 1200/5 Amps class-1, 15 VA, all complete all as specified and directed. Make:-Rishabh or equivelent of Kappa/ AE
Supply only metering current transformer of 1600/5 Amps class-1, 12.5 VA, complete all as specified and directed. Make:-Rishabh or equivelent of Kappa/ AE
Supply only metering current transformer of 2000/5 Amps, Class-1, 12.5VA, complete all as specified and directed. Make:-Rishabh or equivelent of Kappa/ AE
Supply only metering current transformer of 2500/5 Amps, Class-1, 5VA, complete all as specified and directed. Make:-Rishabh or equivelent of Kappa/ AE
Supply only metering current transformer of 3000/5 Amps, Class-1, 1.5VA, complete all as specified and directed. Make:-Rishabh or equivelent of Kappa/ AE
Supply only metering current transformer of 800/5 Amps, Class-1, 2.5VA, complete all as specified and directed. Make:-Rishabh or equivelent of Kappa/ AE
Supply only switch disconnector fuse unit , TPN , open execution, bolted fuse link, 415V, conforming to IS/IEC 60947-3, telescopic shaft for depth adjustment terminal shrouds on both side, door interlock facility of current rating 250 amps including boted HRC fuse (Make- L&T, cat No- FN-250-TPN-SK-95682 & HRC fuse-ST-30781 or equivelent of Siemens/ABB/havells)
All as per item No 16.00 above but capacity of 400 Amps. (Make- L&T, cat No- FN-315-TPN-SK-95591 & HRC fuse-ST-30784 or equivelent of Siemens/ABB/havells)
Supply only HRC fuse of capacity 400 Amps complete all as specified and as directed (Make L&T Cat No SF94335 and equivalent to standard/GE/Schneider)
Supply only HRC fuse of capacity 250 Amps complete all as specified and as directed (Make L&T Cat No SF94333 and equivalent to standard/GE/Schneider)
Supply only MCCB, 4 pole, 400 amp, 36 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Micrologic 2 (up-ASIC based), complete all as specified and as directed Make- Schneider cat Part No- LV432677 or equivelent of Legrand/ABB
All as item No 20.00 above but of size 4 pole, 630 amp, 36 KA. Make Make- Schneider cat Part No- LV432877 or equivelent of Legrand/ABB
All as item No 20.00 above but of size 4 pole, 250 amp, 36 KA. Make Make- Schneider cat Part No- LV431780 or equivelent of Legrand/ABB
All as item No 20.00 above but of size 3 pole, 160 amps, 36 KA. Make- Schneider cat Part No- LV430770 or equivelent of Legrand/ABB
Supply only MCCB 3 pole, 125 amps, 25 KA braking capacity, Ics = 100% Icu as per IEC 60947-2, with Thermal Magnetic Trip Unit. complete all as specified and as directed Make- Schneider cat Part No- LV430311 or equivelent of Legrand/ABB
Servicing, repair, maintinance of Air Circuit Breaker 630 Amps to 3200 Amps capacity by drawing out movable unit, forced air cleaning of movable and fixed unit, decarbonize breaker contracts and checking for any defects due to any flush/loose contact, cleaning of all fixed and moving contact point, terminal connection points with CTC, replacement of defective parts and re-fixing ACB, cables completes all as specified and as directed. Note: (a) required male/female ACB contacts, trip coils, closing coils, electronic protection unit shall be measured and paid seperatelly under respective items in this schedule as supply only. (b) all cleaning agents are included in the quoted rate.
Supply only fixed contract of ACB 630A to 3200A complete all as specified and as directed
Supply only Moving contract of ACB 630A to 3200A complete all as specified and as directed
Supply Only Electronic protection unit of ACB 630A to 3200A complete all as specified and as directed
Supply Only shunt trip coil of ACB 630A to 3200A complete all as specified and as directed
Supply Only closing coil ACB 630A to 3200A complete all as specified and as directed
Supplay, fix and connecting by mannual changeover switch sheet steel enclosure version conforms to IEC 60947-3 of capacity 630 amps four pole complete all as specified and as directed including taking out old unserviceable one (Make- L&T cat PART No-CO46300OSOO or equicalent to Havells/indo asian.
Supplay, fix and connecting by mannual changeover switch sheet steel enclosure version conforms to IEC 60947-3 of capacity 400 amps four pole complete all as specified and as directed including taking out old unserviceable one (Make- L&T cat PART No-CO44000OSOO or equicalent to Havells/indo asian.
Supplying and laying synthetic Rubber insulated mats 20 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety of sizes 2m x 1m. complete all as specified and as directed including taking out old unserviceable one
M&L for painting of outer surface of multiple section of complete LT Panel board size up to 5.5 m x 3.2 in substation Panel board comprising ACBs/MCCBs/SDFs ,busbar chamber, swich gear chamber, metering chamber cable termination/tray using one coat of synthetic enamel paint after preparation of surface, providing protection cover to all metering equipment, panel meters, switchgears, cleaning of all meters and switch gears complete all as specified and as directed
All as per item No 34.00 above but LT panel board size up to 7.5 M X 4.5 M.
M&L old painted steel surfacesand applying one coat of black bituminius paint on both surface of MS cable trench cover complete all as specified and as directed
Dismantling structural steel work of any type. complete all as specified and directed
S&F mild steel work as in cable Rack made with structural steel section conforming to Fe-290 Gde E-165 including embeding in concrete and screwing etc. including all necessary drilling, bolting or riveting, etc. inside duct, on wall , placing in position and fixing to wall with fastener steel bolt not less than 20 mm dia, Note:- Cable rack drawing shall be obtained from Engr-in-Charge.
M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmens complete all as specified and as directed including taking out of old unserviceable MS cable cover/support structure.Grade of steel Fe 410 -W (Gde E- 250) quality -A structure.
M&L preparation of new or previously untreated steel and iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed.
Taking out all earth connection of strip from panel board to earth test pit any size and replace the worn out earth strip, nut/bolts/washers connect all joint with new nots,bolts and washers to in original position complete all as specified and as directed Note :- Earth GI strip if requires shall be measured and paid separetely under respective items in this Schedule as supply only
Supply only Earth continuity conductor GI strip of size 32 X 6 mm complete all as specified and as directed
Materials & Labors for Writing letters or figures (Block.Roman, Italic or Indian) n exc. 30 cm high on LT panel board surface showing incoming and outgoing capacity in Amps and feeder name complete all as specified and as directed.
Dismantling existing unserviceable /corroded LT Pillar Box and supply, fabricate, install, testing and commissioning out-door type, double door dust & vermin proof LT pillar box of 2.1 M length, 1 M width & 1.6 M height fabricated vertically by using 50x50x5 mm angle iron frame, fixing with nuts & bolts on 75 x 40 mm ISMC as per directions of Engineer-in-Charge and using 3 mm thick CRCA MS sheet all over body front and back cover with hinges and aldrops for locking arrangments, 1 mm thick FRP coating all over the external surfaces and 3 mm thick MS sheet for bus bar cover, piller Box, partitions and bottom cable entry covers duly painted with one coat of redoxide and two coats of synthetic enamel paint including control wiring complete in LT piller box with 1.5 sq mm FRLS copper conductor cable and 5A MCB SPs 2.5 amp for meters, breaker control supply and indication lamps including supply & fix following accessories complete all as specified and directed: (a) 3 ph+1N Copper busbar of equal sizes of capacity 1.5 times of rated current of incoming switchgear. (b) 3 ph+1N Copper busbar of equal sizes of capacity 1.5 times of rated current of outgoing switchgears as down links/connectivity links to switchgear. (c) Digital ammeter & voltmeter for incoming & Digital ammeter for outgoing. (d) LED indication lamps for RYB for incoming and outgoing indication.(Red,yellow & blue coloured)
(e) LT ACB – 1600Amps, 4P, 50KA, complete with over current and earth fault tripping device as incomer -01No (f) LT ACB - 1600 Amps, 3P, 50 KA complete with over current and earth fault tripping device as out going-01 No (g) MCCB - 630 Amps, 3P, 36KA complete with over current and earth fault tripping device as out going-01No (h) MCCB - 400 Amps, 3P, 36KA complete with over current and earth fault tripping device as outgoing-01No Note : (i) Unit rate quoted include for necessary grouting / chipping of concrete and Anchor fastners and providing necessary PCC (1:2:4) type B1 using 20 mm graded crushed stone agreegate for foundation to fix the LT Piller Box. (ii) Cost of digital ammeter, voltmeter, LED lamps, CTs, LT ACBs, MCCBs and MCBs shall be included in the quoted rate. (iii) Drawing shall be got approved by GE before fabrication of the LT piller Box. (iv) All incoming and outgoing cable connections are to be made as per existing one and rate deemeded to be included in the quoted rate. (v) The pillar box shall be brought to Jetty gallery part by part and to be assembled in site being limited space of work/movement and rate shall deemed to be included in quoted rate. (vi) Copper busbars with pvc sleeves shall be measured and paid seperately under respective item in this schedule as 'Supply only'
Supply only copper bus bar links with PVC sleeves of raing 630 A to 2000 A complete all as specified and as directed
Supply and fix LT ACB 4 pole 4000 A, 50 KA breaking capacity, 415 V, 50 Hz, manual drawn out type and manually charged with micro processor ET2L trip unit (Without display) release protection system against over current, earth fault and short circuit with 2 NO + 2 NC auxiliary switch, safety shutter, cradle guard, operating handles conforming to IEC 60947-2 & 3 complete all as specified and as directed including taking out old one Make:- Cat.No. MVS40N4MW2L of schneider/L&T/ ABB/ GE/ LEGRAND
All as per item No 47.00 above but of capacity 2000Amps,4pole Cat.No. MVS20N3MW2L of schnider equivelent make in L&T/ABB/GE/lEGRAND
All as per item No 47.00 above but of capacity 1600Amps,4pole Cat.No. MVS16N3MW2L of schnider equivelent make in L&T/ABB/GE/lEGRAND
All as per item No 47.00 above but of capacity 1250Amps,4pole Cat.No. MVS12N3MW2L of schnider equivelent make in L&T/ABB/GE/lEGRAND
All as per item No 47.00 above but of capacity 1000Amps,4pole Cat.No. MVS10N3MW2L of schnider equivelent make in L&T/ABB/GE/Legrand
Attending day to day electrical complaints and call on repair of control panel of street light, security light, garden light, perimeter light, tower light & high mast light provided inside Dockyard, decarbonizing all contact points of contactors , replacement of wornout aluminium cable lugs, wornout screws, nuts, bolts and washers, tightening the loose connections whereever required, adjustment of timer, cleaning and restore the power supply complete all as specified and as directed Note :- (i) Replacement of spares viz MCB, MCCB, contactors, timers, cables, will be measured and paid for separately as supply only and labour element for taking down the replaced spares shall be deemed to include in the unit rate quoted. (ii) The contractor has to engage qualified electricians and helpers in sufficient Nos to attend and rectify the defects. (iii) Job card for repairing work will be issued by concern JE and the same shall be signed by contractor/or his rep and shall be returned to concerned JE on completion of each job work.
S&F PVC junction box of outdoor type, weather proof, with provision of hole at bottom for cable entry, hinged door with locking arrangement, of size not less than 200mm (L) x 100mm(B) x 300mm (H), fixed to pole with MS clamp, nuts, bolts and washers complete including one 3ph 4 pole connection block. incl taking down unserviceable one complete all as specified and as directed Note :MCB shall be measured and paid for separately as supply only Make- Syntex / Hansel
M&L for complete servicing, repair, maintenance of timer panel, by cleaning inside and outside, replacement of burnt MCB, MCCB, Timer, contactor, wiring, bypass toggle switch complete all as specified and as directed Note: Replacement of MCB, MCCB, Timer, Contactor shall be measured as supply only
Supply only power contactor 3 phase, 415V, 32 amps cap utilsed for heavy duty complete all as specified and as directed Make: Schneider, Model-ETVS-LC1E3201 or equivelent of Legrand/L&T/ABB
Supply only surface mounting Analog time switches heavy duty of 230 V 50Hz complete all as specified and as directed Make : 6499 15 Maxi Rex 4QT (daily) of Legrand or equivelent of ABB/L&T
Supply only MCB, SP, 10KA, 'C' 6-32 A complete all as specified and as directed Make:- Schneider or equivelent of Legrand/ABB /L&T
Supply only MCB, DP, 10KA, 'C' 40A-63 A complete all as specified and as directed Make:- Schneider or equivelent of Legrand/ABB /L&T
Supply only MCB, 4P, 10KA, 'C' 40A-63 A complete all as specified and as directed Make:- Schneider or equivelent of Legrand/ABB/L&T
Supply only MCCB with thermal magnetic release, 16 KA, 3 pole, 415V, 100 A, complete all as specified and as directed Make:- Schneider , Model- Easy compact CVS 100 BS, LV510950 to 58 or equivelent of Legrand/ABB/L&T
Material and labour for disconnecting the burnt out high mast tower winch motor 3 phase ,415V, 50Hz,1400 RPM, 4 pole, 2HP and rewinding with supper enameled copper wire of same gauge / size of wire including re-fixing the same in its original position testing and commissioning complete all as specified and as directed
Material and labour for servicing of high mast tower control mechanism by greasing and varnishing of electric motor 2 HP, 3 phase 415 volts 50Hz including replacement of unsv plug and socket for trouble free functioning including painting of starter panel with one coat of synthetic enamel paint complete all as specified and as directed
Supply and fixing high mast tower winch motor 3 phase 415 V 50Hz 1400 RPM 4 Pole 2HP complete all as specified and as directed including taking out old one.
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in soft loose soil for cable work or from above cable duct complete all as specified and as directed
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed.
Removing of excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and as directed.
M&L for dry sand cushioning for under ground cable provided with layer and sand 8 cm deep before laying the cable and 15cm after laying the cable complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mm x 180mm x 40mm complete all as specified and as directed
Surface dressing of areas by Clearing away all grass, wild vegetation, saplings, shrubs, brushwood, undergrowth, roots, and trees not exceeding 30cm girth and removing rubbish upto a distance of 50 meters outside the periphery of the area under clearance complete all as specified and as directed
Taking out old unserviceable LT UG cable of any size any description complete all as specified and as directed
Supply and fixing/Laying through trench.surface or wall including required necessary saddle/clamp any hight HDPE double wall pipe corugated pipe of size 40 mm dia for cable protection laid in trenches in lieu of sand/brick protection complete all as specified and as directed including taking out old one.
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 6 Sqmm 2 core and connection complete with aluminium cable lugs complete all as specified and as directed
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area10 Sqmm 4 core and connection complete with aluminium cable lugs complete all as specified and as directed
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area16 Sqmm 4 core and connection complete with aluminium cable lugs complete all as specified and as directed
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 25 Sqmm 3.5 core and connection complete with aluminium cable lugs complete all as specified and as directed
Supply and laying in trenches XLPE insulated, armoured, heavy duty electric cable with stranded aluminium conductor, 1100 Volts grade cross section area 35 Sqmm 3.5 core and connection complete with aluminium cable lugs complete all as specified and as directed
Taking out old UNSV HT UG cable of any size and any description complete all as specified and as directed
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 185 sq. mm 3 core complete all as specified and as directed
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 240 sq. mm 3 core complete all as specified and as directed
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 300 sq. mm 3 core complete all as specified and as directed
Supply and laying XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with aluminium conductor, 11000 volts Earthed,grade cross sectional area 400 sq. mm 3 core complete all as specified and as directed
Supply and Fix cable route indicator to indicate path of HT cable 11000 Volte material usde cast iron with pcc work complete all as specified and as directed
M&L for dismatling and taking out street light cable loop near pole for size of cable 6 sqmm to 25 sqmm after dismantling connection from junction box, cutting, removing damaged portion of the cable ends, providing new aluminium cable end terminals, laying of cable through protection pipe through coping to junction box including necessary connection, earth work complete all as specified and as directed. (Note: Only cable protection, pipe shall be measured and paid measured & paid separately as supply only)
M&L for dismantling taking out cables 10 sqmm to 16 sqmm from trench, including making straight through joints at damaged portion and relaying in trenches complete including necessary connection, earth work all as specified and as directed
M&L for dismantling taking out cables 25 sqmm to 35 sqmm from trench, including making straight through joints at damaged portion and relaying in trenches complete including necessary connection, earth work all as specified and as directed
Supply and fixing PVC insulated, PVC round shethed copper flexible electric cable 1.5 sqmm 3 core, 1100 Volts grade and dismantling wornout/defective cables from SL/Flood light fitting at pole/tower top to JB at bottom of pole through pole /tower complete all as specified and as directed
M&L for dismantling of non - functional street light/flood light from any type of pole at hight upto 9 mtr by suitable ladder for repair of the same for replacement unserviceable items like LED driver, connector block and decarbonising contact points and refixing the same to pole after repair of any type security light . Note:- Required LED driver shall be measured and paid separately under respective items as supply only rate
Supply only LED driver suitable for street light fitting 1x 120 Watt, 230V, make- CG/halvells/Bajaj/Philips/Wipro
Supply only LED driver suitable for street light fitting 1x 150 W , 230V, make- CG/halvells/Bajaj/Philips/Wipro
Supply only LED driver suitable for flood light fitting 1x 200 W, 230v, make- CG/halvells/Bajaj/Philips/Wipro
Supply only LED driver suitable for flood light fitting 1x 250 W, 230v, make- CG/halvells/Bajaj/Philips/Wipro
S&F on wall/pole timer enclosure out door type complete with timer Analog time switches heavy duty of 230 V 50Hz, power contactor 3 phase MNX 18 , 415V, 32 amps, MCB, TPN, 10KA, 'C' 40A-63 A with, rotary switch with connector for incoming and outgoing cable entry complete all as specified and as directed including taking out old one. Make Indi Asian/Havells
M&L for painting of steel fabricated light tower not less than 10 mtr high with one coat of aluminium paint after preparation of complete surface complete surface including writing tower number with synthetic enamel black paint complete all as specified and as directed
M&L for painting of steel tubular pole / swan neck pole any type upto 9 metre height with one coat of aluminium paint after preparation of complete surface including writing pole number with synthetic enamel black paint complete all as specified and as directed
M&L for preparation of existing old plastered surfaces of wall & applying one coat of white wash complete all as specified and as directed
S & F Street light fitting LED 150 watt watt complete all as specified and as directed including taking out old one.Make- CG or equivelent of halvells/ Bajaj/ Philips/ Wipro
S & F Flood light fitting LED 210 watt watt complete all as specified and as directed including taking out old one Make- CG or equivelent of halvells/ Bajaj/ Philips/ Wipro
S & F Flood light fitting LED 300 watt complete all as specified and directed including taking out old one, Make- CG, Model- CFS-501-300-57-60D-SL-GL-NGG or equivelent of halvells/ Bajaj/ Philips/ Wipro
S & F Flood light fitting LED 350 watt complete all as specified and directed including taking out old one, Make- CG, Model- CFS-501-350-57-60D-SL-GL-NGG or equivelent of halvells/ Bajaj/ Philips/ Wipro
Taking down old unserviceable aviation light fitting, and supply & fix new LED aviation light fitting with yellow painted die-cast aluminium alloy housing, red coloured polycarbonate dome and accessories including clamps, nuts, bolts and service connections up to the junction box complete all as specified and directed Make Bajaj and cat No.BJAOL 2 BC GLS 2 X 100W BC bajaj or eqiuvalent in philips/CG/havells/Wipro.
Cleaning of cable duct of size 1.2 x 1.0 by removing out all mud, soil, waste materials and disposal of waste materials outside Dockyard area complete all as specified and directed
M & L for road cutting /hard standing to a depth not less than 80 cm and not less than 60 cm wide for laying of GI pipe to draw to UG cable and making good the disturbed surface by filling of PCC (1:3:6) type C-2 using 40 mm graded stone aggregate and finished the surface even and smooth with out using extra cement and disposal off the surplus debris and soil outside Dock Yard complete all as specified and as directed
M & L 80 mm bore GI pipe tubes light grade for cable protection supporting with all fixing accessories (clamp, nuts, bolt and washer etc ) complete all as specified and as directed including taking out old one.
Dismantling/ taking out HT Cable from cable rack / floor at gallery of marine jetty for repair / replacement of wornout steel cable rack or for realingnment of cable and refixing the cables with proper staking with proper alignment of cable on repaired/existing rack and making feeder wise bundle of cable using PVC cable tie for sizes of cable 3 core, 185 to 240 sqmm, 11000 volts grade complete all as specified and as directed. Note:- Each cable shall be measured separately.
Dismantling/ taking out HT Cable from cable rack / floor at gallery of marine jetty for repair / replacement of wornout steel cable rack or for realingnment of cable and refixing the cables with proper staking with proper alignment of cable on repaired/existing rack and making feeder wise bundle of cable using PVC cable tie for sizes of cable 3 core, 300 to 400 sqmm, 11000 volts grade complete all as specified and as directed. Note:- Each cable shall be measured separately.
M&L for finding of cable fault of UG 11000 volts grade cable inside trench (under soil / drain/PCC/road/trench ) by disconnecting both cable ends, using insulation tester, cable path/fault finder and rectification complete by necessary excuvation, cutting at fault position, fixing of straight through heat shrink joint, for cable sizes 185 sqmm to 400 sqmm, 3 core, 11000 volts grade or replacement of heat shrink indoor cable joint kit of size 185 sqmm to 400 sqmm, 3 core and reconnection of both cable end to original position after complete satisfactory insulation test, fixing with old or required new nuts-bolts-washers complete with testing complete all as specified and as directed Note: (a) Items required for rectification such as heat shrink indoor cable joint kit / heat shrink straight through joints and earth work shall be measured separately .as supply only rate (b) required aluminium cable lugs and nuts-bolts-washers shall be inclusive of quoted rate. (c) Contractor shall bring necessary testing equipment and rate shall be inclusive of quoted rate.
Supply only Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and as directed
Supply only Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 300 sqmm complete all as specified and as directed
Supply only Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 400 sqmm complete all as specified and as directed
Supply only Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 185 sqmm complete all as specified and as directed
Supply only Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 to 400 sqmm complete all as specified and as directed
M&L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 mtr below ground level with top edge of earth plate at a depth not less than 1.5 mtr below ground level connected to galvanised iron or steel earth lead MS flat 32 x6 mm by means of nuts, bolts, check nuts and washers of galvanised iron or steel, earth wire protected by galvanised iron pipe 40 mm dia (light grade) and connected to main switch board or main control panel as directed and as specified including concrete pit in PCC (1:3:6) type C1 pre-cast RCC cover slab 5 cm thick of size as shown reinforced with 8 mm dia TMT / deformed bars 100 mm c/c both ways including one handle made of 12 mm dia MS bars of length 500 mm, funnel, wiremesh 20 mm bore galvanised iron pipe medium grade for watering, charcoal and salt in alternate layers including necessary earth work complete all as shown in elect plate No. 3 of SSR Part I, complete all as specified & directed.
M & L for Earth continuity conductor GI strip of size 32 X 6 mm complete all as specified & directed. .
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .