| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.9 LAccepted-AOC | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹16.2 L+₹3,887 (0.24%)Rejected-AOC | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹16.7 L+₹54,545 (3.37%)Rejected-AOC | L3 | Rejected-AOC Bid is not lowest and reasonable | |
| 4 | L4₹16.9 L+₹69,116.75 (4.27%)Rejected-AOC | L4 | Rejected-AOC Bid is not lowest and reasonable | |
| 5 | L5₹17.2 L+₹94,856.50 (5.85%)Rejected-AOC | L5 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
27 Aug 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE RAMGARH CANTT
GE RAMGARH CANTT, JHARKHAND PIN 829122
REPAIR AND CLEANING OF SEWAGE LINE OF SRC AREA MINOR UNITS AND DAD AT LEKHA NAGAR AT RAMGARH CANTT UNDER GE RAMGARH
2022_MES_541987_1
8300/3123/E8
Open Tender
Civil Works
Item Rate
330 days
GE RAMGARH
Class E Cat a(ii)
7 documents required · 7 mandatory
₹500
Yes
GE RAMGARH CANTT
₹30,000
Yes
11 Oct 2022
30 Jul 2022
31 Aug 2022
30 Jul 2022
27 Aug 2022
22 Aug 2022
60 days
Amount
Excavation in trenches in soft/loose soil not exc 1.5 m wide and not exc 1.5 m in depth for foundation or shafts, wells cesspits, manholes, pier holes etc and getting out, complete all as specified and directed by Egineer -in-Charge.
Returning, filling in and including spreading, leveling, watering and well ramming in layers n.exc 25 cm in layer complete all as specified.
Removing of excavated materials to a distance n. exc 50m and depositing where directed at a level n exc 1.5m above the starting point in soft/loose soil complete all as specified.
Demolition and breaking up drain pipes of 150mm dia (SGSW/AC/RCC/PVC) set in cement mortar including bed concrete and removal of debris to low lying area of distance not exceeeding 100m, complete all as directed by Engr-inCharge.
All as per serial Item No 4 here-in-before but 200mm dia pipe, complete all as directed by Engineer -in-Charge.
S & F, Reinforced concrete drain pipes of 150mm dia class NP2 laid and jointed with collars in trenches and jointed, complete all as specified and as directed by Engr-in-Charge
S & F, Reinforced concrete drain pipes of 200mm dia class NP2 laid and jointed with collars in trenches and jointed, complete all as specified and as directed by Engr-in-Charge
M & L for PVC(SWR) pipes 150mm bore single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and as directed.
M & L, for Concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid in PCC 1:3:6 type C2 using 40mm graded stone aggregate including necessary shuttering and tested complete for 150mm bore pipe all as specified and directed.
M & L, for Concrete bed to drain pipes including packing under and haunching against the sides of pipes concrete after they are laid in PCC 1:3:6 type C2 using 40mm graded stone aggregate including necessary shuttering and tested for 200mm dia of pipes complete all as specified & as directed
Demolition of cement concrete in ground floors & paving n.exc 15cm thickness (below or above ground level) complete all as directed by Engr-in-Charge
M & L for 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate including finished surface even and fair without using extra cement as in plinth protection including necessary formwork of edge, all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr interval and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio (1:3).
M & L for PCC (1:3:6) type C2 (using 40mm graded stone aggregate ) in foundations, filling and mass concrete complete all as specified.
Demolition Reinforced cement concrete as in precast cover of manholes etc., (reinforcement cut as required to facilitate demolition), complete all as specified and as directed.
S & F precast reinforced cement concrete manhole cover in RCC(1:2:4) type B1 using 20mm graded stone aggregate set in cement mortar(1:6), complete all as specified.
M & L for mild steel TMT bar 8mm dia cut to length bent to shape required including cranking bending spirally for hooping for column, hooking end binding with binding wire and including mild steel wire(annealed) not less than 0.9mm dia complete all as specified & directed by Engineer in Charge.
Demolition of brick work built in cement mortar as in drain, manhole etc complete all as specified and as directed.
M & L brick work with old size bricks straight or curved on plan exc 6m mean radius built in CM (1:4) as in drain, manholes etc complete all as specified.
All as per item No.18 here in before but except bricks, using old serviceable brick as retrieved.
M & L brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius half brick thick wall built in CM (1:4) etc complete all as specified.
Extra for fair finish drain or channel to any girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc complete all as specified & directed by Engr-in-Charge
M & L plain cement concrete type B0(1:2:4) using 12.5mm graded stone aggregate as in benching, bed block, coping of manhole, surface channel drains, etc., complete all as specified.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed by Engr-in-Charge
M & L for Setting coat of 3mm thick of CM (1:1), trowelled to even and smooth finish over rendering 15mm thick in CM 1:4 on fair faces of brick work finished surface even & fair with using water proofing compound @ 2% complete all as specified and directed.
Supply only integral waterproofing compound
M & L, 15mm thick rendering on fair faces of brickwork in cement mortar (1:4), surface finished even & smooth without using extra cement, complete all as specified and as directed.
Cutting into existing manholes for connecting new drains, making good to pipe and rendering , cutting out existing benching for and forming branch channel (1/2 round or ¾ section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required for 150mm dia pipe, complete all as specified and as directed.
Loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage well, complete all as specified and as directed.
Cleaning of sewage line 200mm dia/bore of pipe by Rodding and well flushing by using sufficient water and making it clear for easy flow of sewage up to the septic tank including cleaning of manhole sludge, silt etc removing the sludge in low lying area and burying it in pits as directed by Engineer-in-Charge.
All as per Items No. 29 here in before but cleaning of sewage line of 150mm dia complete all as specified and as directed
Removing blockage of or from water closet(Indian or European type)/WHB/Sink/Floor trap/Gully trap upto first manhole ( Indian or European type ) by removing solid/liquid or mud deposited in the trap or CI pipe line by rodding manually and removing the sludge duly covered in a hygenic manner and making the WC (Indian or European type)/WHB/Siink/Floor trap/Gully trap fully functional, complete all as specified and as directed by Engr-in-Charge.
Cleaning of septic tank of following capacity from any type of material like solid/fluid, mud sludge etc by mechanical motorised suction machine and deposited/removing the sludge etc outside the MD land shall be conveyed in closed container and also disposed off in the place properly using bleaching powder etc complete for (a) For Septic Tank of 25 users capacity all as directed by Engr - in -Charge Note: (Date of cleaning of Septic Tank with location shall be recorded in MB for record purpose.
All as per item no 32 here-in-before but for 50 users.
All as per item no 32 here-in-before but for 100 users
All as per item no 32 here-in-before but for 200 users
All as per item no 32 here-in-before but for 300 users
All as per item no 32 here-in-before but for 400 users
All as per item no 32 here-in-before but for 500 users
Taking down eaves gutter, soil waste and vent, rain water pipes (any size or pattern) , including all fittings complete all as specified and directed by Engineer-in-charge.
S & F, 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall, complete all as specified and as directed by Engineer-in-charge.
S & F, 75mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to wall/laid in trenches complete all as specified and as directed by Engineer-in-charge.
S & F, 110mm bore PVC (SWR) bends any radius complete all as specified and as directed by Engineer-in-charge.
S & F, 110mm bore PVC (SWR) bends any radius with access door jointed with ruber ring joints fixed to wall complete all as specified and as directed by Engineer-in-charge.
S & F, 110mm bore PVC(SWR) branch piece pipe single Y equal or unequal with access door, all as specified and as directed by Engr-in-Charge, complete all as specified and directed.
S & F, 110mm bore PVC(SWR) branch piece pipe double Y equal or unequal, all as specified and as directed by Engr-in-Charge, complete all as specified and directed.
S & F, 75mm bore PVC (SWR) bends with rubber ring joints fixed to wall, complete all as specified and as directed by Engineer-in-charge.
S & F 110mm bore PVC(SWR) vent Cowl complete all as specified and directd.
S & F mild steel work such as bands, straps, supports or stays for rainwater, ventilating pipes, handmade clamps, hold fasts and similar small articles conforming to Fe-410-0 or Fe-310-0, complete all as specified and as directed.
S & F in repair water closet Vitreous china squatting pan Orissa pattern of size 580x440mm white with integral foot rests (excluding flusing cistern and flush pipe) including connection to trap and to flushing pipe, anti-syphonage connection pipe etc complete making good disturb surface with existing finish of floor all as specified & directed by Engineer-in-Charge.
S & F in repair vitreous china wash down water closet pan, pedestal pattern Pedestal pan and trap(excluding flushing cistern and flush pipe), including connection to drain (or outgoing pipe) and to flushing pipe, anti-syphonage pipe, etc and including seat and cover for pedestal pan, complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding, removing serviceable tile to store and rubbish off the premises.
M & L for cement concrete type B1, 1:2:4 (using 12.5 mm graded aggregate) in levelling courses, coping, window cill etc., complete all as specified and directed.
M & L non skid coloured ceramic tiles 7 to 8 mm thick (sqaure/rectangular) area of each tile exe. 0.06 sqm but n.exe.0.11 sqm, in floors etc., over and including 15mm thick screed bed in cemen mortar (1:4) set and jointed in neat cement slurry and pointed in coloured cement to match the existing surfaces, complete all as specified and directed.
Material and labour for glazed ceramic colour tiles 300x200 x 7mm thick as in skirting/dados etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles over 10mm thick rendering in cement mortar 1:4, complete all as specified and directed.
S & F in repairs 10 litres capacity PVC low level flushing cistern complete with all fittings complete all as specified and directed by Engineer-in-charge.
M & L for cement concrete Type B0 (1:2:4 ) using 12.5mm graded aggregate in roof kerbs or mud stops, rounded or chamfered on edge, complete all as specified and as direced.
S & F in repair vitreous china urinals, bowl type (back or corner wall type) of size 465x355x265 mm, complete including providing and fixing plugs, waste coupling, waste pipe, bedding urinal against wall in cement mortar (1:2), securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back complete all as specified and directed.
M & L for cleaning of PVC water storage tank of capacity 1000 Ltr on existing bldgs with disconnecting of inlet and outlet pipe, clean with brush/cotton cloth, removing of silt, dirt removing of vegetation etc., by applying bleaching powder, lime and washing of water tank and fixed in same position, complete all as specified and as directed by Engr-in-Charge.
M & L for cleaning of PVC water storage tank of capacity 500 Ltr on existing bldgs with disconnecting of inlet and outlet pipe, clean with brush/cotton cloth, removing of silt, dirt removing of vegetation etc., by applying bleaching powder, lime and washing of water tank and fixed in same position, complete all as specified and as directed by Engr-in-Charge.
M/S Akash Enterprises
M/S Kunwar Construction
M/s friend enterprises
ranjit singh
upadhyay engineers and consultant
ganpati enterprises
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .