| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹7.4 LAccepted-AOC | 1 | Accepted-AOC L1 BIDDER | |
| 2 | 2₹9.3 L+₹1.9 L (25.1%)Rejected-AOC | 2 | Rejected-AOC OTHER THAN L1 BIDDER |
Tender Value
Refer Docs
EMD Value
₹15,000
Closing Date
22 Mar 2021, 6:00 pmClosed
Garrison Engineer
GE I P Fy ISHAPORE, PO NAWABGANJ, DIST 24 PGS N WB-743144
As per tender documents
2020_MES_396087_3
8654/2020-21/E8
Open Tender
Electrical and Maintenance Works
Item Rate
90 days
GE I P FY ISHAPORE
Class E Category b(ii)
6 documents required · 6 mandatory
₹500
GE I P FY ISHAPORE
₹15,000
Yes
26 Mar 2021
8 Mar 2021
23 Mar 2021
8 Mar 2021
22 Mar 2021
8 Mar 2021
8 Mar 2021 - 15 Mar 2021
Amount
Taking down and removing existing OCB 6 KV after disconneting the incoming/outgoing connections, earthings and removal of grounting bolts embedded in concrete foundation and depositing to MES storeyard complete all as specified and as directed.
Supply, installation, testing and commissioning of vacuum circuit breaker (VCB) comprising of the under-mentioned accessories/parts including necessary civil work as specified and directed by Engineer-in-Charge. Detail description as under:-
VCB DETAILS 6.6 KV, 400 A, 18.4 KA, drawn out type VCB with motorised spring charge mechanism suitable for 240 VAC, with closing & tripping coils for 110 V DC Make - Schneider PANEL, BUSBAR, CURRENT TRANSFORMER & POTENTIAL TRANSFORMER DETAILS (i) Fully compartmentalised sheet steel totally enclosed floor mounted with safety shutters, horizontal drawout & mounted with safety shutters, horizontal isolation, alongwith insulated PVC sleeve for (630 A Cu, BUS BAR), foundation bolts etc., with provision for terminating PILC/XLPE cable
(ii) Resin cast, dual core CTs having CT ratio 100-50/5+5A with core 1:15 VA, CL-1, core 2:15 VA, CL:5P10 Make - Schneider (iii) 1-PH PT-6.6 KV/RT3/110V/RT3, 100VA CL-1, 100 VA, 3P with fuses for primary and secondary circuit and OVF; 1.2 cont and 1.9 times for 8 hours Make - Schneider BREAKER PANEL INDICATION LAMP (i) On/Off/Trip/Spring Charge/TC healthy/Test/Service (ii) R-PHASE, Y-PHASE, B-PHASE indicating lamp (iii) Heater switch (iv) Thermostat SWITCHES AND OTHER ACCESSORIES (i) AC on/off switch. (ii) DC on/off switch.
METER (i) 3 -Phase digital ammeter, Cl- 1.0, (ii) 3 -Phase digital voltmeter, Cl - 1.0 (iii) Digital multifunction meter with- A, V, KW, KWH, PF, Hz, Cl-1.0 RELAY (i) Numerical feeder protection realy MICOM P111-L, (ii) Master trip relay, AVAJH13, (iii) Auxillary relay, AVA33
M&L for Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sq mm
Materials and labour for earthing complete with copper earth plate electrode 600 mm x 600 mm x 3mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with 20 x 3mm copper strip by means of nuts, bolts, check nuts and washers made of copper strip to be protected by galvanised iron pipe 25 mm bore (light grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (medium grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) including testing complete all as specified and as directed. Note: Earth strip upto 7.5m shall be deemed to be included in the quoted rate of the item.
Material and labour for copper earthing strip 20 x 3 mm buried in ground for earthing all as specified.
Supplied and fixed Tubes, 'light grade',galvanised,with all fitting;laid in trenches for bore dia of pipe 25mm to be used as protection to copper earth strip all as specified.
M/s Anil Kumar Dutta
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .