| 1 | L1₹75,284.95Accepted-AOC | L1 | Accepted-AOC Agreement executed by Shabu D on 17.08.2022 |
Tender Value
₹77,418
EMD Value
₹2,000
Closing Date
30 Jun 2022, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Thiruvananthapuram Corporation 695033
Providing electrification in the buildings for the Anganvadi No. 131 at Harbour ward under City Corporation, Thiruvananthapuram
2022_LSGD_494813_4
EE(C)/OWNFUND TENDER/2022-23 (5)
Open Tender
Electrical Works
Item Rate
90 days
Thiruvananthapuram Corporation
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
Yes
₹2,000
Yes
16 Sept 2022
23 Jun 2022
2 Jul 2022
23 Jun 2022
30 Jun 2022
23 Jun 2022
Amount
Supply and wiring points according to IS 732-1989 using rigid PVC ivory Conduit of minimum size 20mm conforming to IS 9537 Part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm PVC insulated stranded single core FR copper conductor cable 650V grade including providing switch board main and continuous earthing with 1.5 sqmm green coloured FR wire required quantity of copper earth socket, brass bolt and nuit crimping etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type ROHS compliant SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required.(ROHS Complaint modular accessories)
90.2.1.3 Single control light point without ceiling rose
90.2.1.4 Single controll ceiling fan point with 6A.3 plate ceiling rose and with socket typepped electronic regulator
Combined plug point with 6 A, 5 pin plug socket controlled by 6 A, switch in the same switch board as that of light points
Independent plug
Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thickness complete with all accessories and lamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required. 1200 mm 1X20W LED Lamp with box type fixture
or Supply and fixing angle/ straight brass lined skirt type, bakelite batten holder without shade and giving connections etc. as required with 10 W LED bulb.
Supply and installation of suitable size MS rod type fan clamp in the RCC slab as per IS 732 as required.
Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required. 1200 mm sweep (category B) 5 star rated ceiling fan complete iwht 300 mm down rod, canopies, shackles and blades and resistance type regulator working on 230/240V single phase A/C.
Charges for cutting holes suitable for accommodating exhaust fan up to 305mm sweep including plastering colour washing etc. as required.
MR 1199 305 mm sweep 900 RPM heavy duty exhuast fan working on 230V A/C.
200mm sweep light duty exhaust fan in plastic body with self opening lowers working on 230V single phase A/C supply.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mmX125mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 Amp switch.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 Amp switch.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm)
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 15/16 amp switch.
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16 socket outlet.
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 20 sq mm
Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.
(90.6.4.13) 1.5sq mm 3 run
(90.6.4.22) 2.50 sq.mm. 2 run
(90.6.4.32) 4.00 sq.mm. 2 run
Supplying and fixing following way single pole and neutral sheet steel MCB DB 240V on surface/recess complete with tinned copper bus bar neutral bus bar earth bar din bar intetconnections powder painted including earthing etc required (but without MCBI/RCCB/Isolator) 12 way double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps
Supplying and fixing following rating, 2 pole,single phase and neutral (RCCB) having a sensityvity current upto 300mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 Amps
Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Supply and laying bare earthing conductors of the following sizes laid 0.6 m below ground level including excavating trench of suitable size and refilling etc as required (in ordinary soil) 3.15.00mm copper conductor (14 SWG)
Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc as required 2.00mm copper conductor (14 SWG)
Supply and drawing bare copper conductors of the following sizes along with wiring cables and giving connections etc as required 3.15mm copper conductor (10 SWG)
Supply and providing the following sizes of bolt and nut with washers on the existing MS box/ earth bus etc. as required including drilling necessary holes as required.
25x6 mm brass bolt and nut
25x3 mm brass bolt and nut
OR Supply of superior quality copper earth socket for the following sizes of earth conductor including crimping etc as required. 2.00 mm (14 SWG)
3.15 mm (10 SWG)
Supply, fabrication, conveyance and fixing the following sizes of B class GI pipe bent to shape / cut and welded to shape and fixing the same to wall / parapet using clamps as noted along with each size, painting with 2 coats of synthetic enamel paint over a coat of zinc chromate primer, making good the damages, colour washing etc as required. 32 mm dia with HG company fabricated clamps
(MR1183) 36/40 W 4000 lumen LED, IP66 street light fittings with Aluminium housing stove enameled CRCA sheet, Steel reflector cover, acrylic cover complete with THD <10%, power factor>0.98, RoHS complaint duly wired up for use on 230 V ac supply
Supply and fixing cast aluminium stove enameled bulk head fitting with deep drawn anodised alumi8nium body, epoxy powder coated, heat resistant prismatic glass cover suitable for 9 W CFL to wall/ceiling including giving connections with required length of 16/0.20mm PVC insulated and PVC sheather 3 core round copper conductor flex wire conforming to relevant ISS or extending the original wiring and making good the surface as required
Fabrication, supply & installation of dust and vermin proof, wall mounting, thermoplastic meter box of following size suitable for fixing KSEB meter, fuse units, CT etc, hinged door construction for the front side with compartments if necessary, providing vision panel for the meter compartment, knock out for cable entry and exit. 450x300x214mm
S & F switch disconnector fuse unit complete with handle assemble, door inter lock and padlocking arrangement of the following ratings. 32A SP SDF
or supply and fixing the following accessories in the existing meter board and giving connections etc. 32A 415V DIN type fuse base .
32A 415V Backlite fuse fittings
32A 415V 2 way neutral link mounted on DMC/SMC base.
Amount remitted to KSEB for obtaining Power supply (actual amount will be reimpersed on production of original receipts)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_711846.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .