Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.6 LAccepted-AOC 59 NEW MARKET CLOCK TOWER DEHRADUN UK PIN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹23.1 L+₹3.3 L (16.6%)Rejected-AOC | L2 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 3 | L3₹23.1 L+₹3.3 L (16.6%)Rejected-AOC | L3 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 4 | L4₹24.7 L+₹4.8 L (24.4%)Rejected-AOC | L4 | Rejected-AOC OTHER THAN LOWEST BIDDER | |
| 5 | L5₹30.4 L+₹10.6 L (53.4%)Rejected-AOC | L5 | Rejected-AOC OTHER THAN LOWEST BIDDER |
Tender Value
Refer Docs
EMD Value
₹98,320
Closing Date
13 Mar 2021, 6:00 pmClosed
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT- 133001
MANNING AND OPERATION OF WATER SUPPLY INSTALLATIONS AT TUBEWELLS IN SECTOR B UNDER GE UTILITY AMBALA CANTT
2021_MES_419641_1
GE(U)/AMB-57/2020-21
Open Tender
Civil Works
Item Rate
330 days
AMBALA CANTT
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Yes
GE UTILITY AMBALA CANTT
₹98,320
Yes
19 Apr 2021
22 Feb 2021
15 Mar 2021
22 Feb 2021
13 Mar 2021
8 Mar 2021
22 Feb 2021 - 6 Mar 2021
Amount
SCHEDULE 'A' (SECTION-I) Manning and Operation of complete water supply System By Technically qualified Teams for round the clock (01 FGM per shift of 8 hrs) including Sunday and Holidays .The installation comprises of 40 HP Submersible pump set at TW - 29 and electric control panel etc. The scope of work primarily comprises of :-
(a) Running of pump set and to fill connected over head tanks complete round the clock all as directed by Engr -in-charge otherwise a panelty of Rs 900/- per day will be imposed for not running pump sets without any fault or over running the pump set resulting in overflow of OHT and wastage of water.
(b) Operation of chloronome plants.Contractor will be responsible for proper chlorination of water i.e 2 ppm at installation and maintain the register of daily results otherwise a panelty of Rs 250/- per day will be imposed for non operation of chloronome plants and Rs 350/- per day penalty will be imposed for not maintaining the results of 2.00 ppm at installation.
(c ) Minor repair Such as gland packing ,Nut Bolts if reqd at site otherwise a panelty of Rs 100/- per day will be imposed for not providing gland packing/ leakage of valves within the installation.
(d) Rectifying any electric complaints within the installation which is essential to run installation will be carried out by the contractor otherwise a panelty of Rs 500/- per day will be imposed for not rectifying the electric complaints within the installation.
(e) The contractor will submit Log Sheet of pump set, generator and chloronome plant per month to Engr-in -Charge. In case of non submission of log sheets a panelty of Rs 250/- per day will be imposed.
(f) Area of installation will be Kept neat & clean by removing growth of vegetation ,grass and bushes at of installation, at the path of installation and upto whole installation .Suitable endorsement for this will be made daily in a register kept at installation.Panel recovery at the rate of Rs 250/- per day will be recovered in case of installation and surrounding area found unsatisfactory.
(g) Proper accounting and security of Govt Assets. Any loss will be made good by the contractor. All the pumpsets installed in pump house will be sole responsibility of the contractor.Any damage or loss of the govt property will be made good by the contractor.
(h) All type of Stationary ,T&P for maintenance & operation will be provided by contractor .
(j) All safety provision contained in IE rules will be followed by the contractor.
Description all as per srl item No 1.00 here In before but in 40 HP submersible pump set TW-45 Sec B Area complete all as specified and directed by Eng-in-Charge.
Description all as per srl item No 100 here In before but in 50 HP submersible pump set TW-13-A Sec B Area complete all as specified and directed by Eng-in-Charge.
Description all as per srl item No 1.00 here In before but in 50 HPsubmersible pump set TW-37 Sec B Area complete all as specified and directed by Eng-in-Charge.
Description all as per srl item No 1.00 here In before but in 30 HP submersible pump set TW-13 Sec B Area complete all as specified and directed by Eng-in-Charge.
a) Cleaning of valve pit. Rs.100 will be imposed for not cleaning of valve pit, a register will be maintained for the same.
b) Minor repair such as gland packing, tightening of nut bolts etc if required Rs.100 will be imposed for leaking of valve.
c) Area of installation below and upto 3 mtr surrounding over head tank , its path will be kept neat & clean by removing growth of vegetation, grass and busses at the installation, at the path of installation and upto whole installation. Suitable endorsement for this purpose will be made daily in register kept at installation. In case of failure, a penalty of Rs. 250/-per OHT per day will be recovered if the installation and surronding area found unsatisfactory.
d) Log sheet to be maint and submitted at the month end for Panelty of Rs.200
e) Proper accounting and security of Govt assests.
f) All type of stationary by contractor.
g) All safety provn to be maint by contractor.
h) Manning person can be utilised at any other installation as per directed by Engr in Charge
(j) The rates qouted by the contractor shall be inclusive all taxes like GST,EPF, ESI, LWC as applicable and also include contractor's profit etc. In this connection please refer Note 20 of Sch A/BoQ Notes mentioned in tender documents.
Note for contractor for Item No. 1.00 to 5.00: (a) Providing summer and winter uniform along with proper shoes to the operators.(b) Providing T&P and display board of the firm along with minimum fare wages written on it. (C) Maintaining log sheets, duty roster, attendance register along with photo of the individual operator must be displayed at pump house or at the installation. (d) Rates of all above notes deemed to be included by the contractor in quoted rates. (e) If all above documents are not found during inspection of AGE or GE, the penalty of Rs.100/-per day will be imposed from the first date of the each month.
SCHEDULE 'A' (SECTION-II) Supply and fix in replacement MCCB TP , 16 KA breaking capacity, 100 Amp, 50 Hz with adjustable thermal and magnetic release and Ics = 100% Icu complete with thimbles and nut-bolts complete all as specified and directed.
Supply and fix in replacement MCCB TP , 25 KA breaking capacity, 160 Amp, 50 Hz with adjustable thermal and magnetic release and Ics = 100% Icu complete with thimbles and nut-bolts complete all as specified and directed.
Supply and fix in replacement MCCB TP , 25 KA breaking capacity, 200 Amp, 50 Hz with adjustable thermal and magnetic release and Ics = 100% Icu complete with thimbles and nut-bolts complete all as specified and directed.
Supply and fix in replacement MCCB TP , 25 KA breaking capacity, 250 Amp, 50 Hz with adjustable thermal and magnetic release and Ics = 100% Icu complete with thimbles and nut-bolts complete all as specified and directed.
M&L taking out the pumpset and transportation for repairing motor pump set to workshop, taking out burnt winding wire from submersible motor of capacity 50/40 HP 3 phase ,rewinding with suitable size of PVC coated copper winding wire including replacement of burnt bushes complete including all insulation material and transportation back to site and lowering down the same, testing and commissioning complete all as specified and directed by Engineer in charge : Note: (i) Any electric fault occur during the running of the motor after repair shall be detected by the contractor and rates are deemed to be included in the item for rectification of the fault. (ii) The motor burnt or submersible cable/earth fault/cable fault or any other reason will also beared by contractor. (iii) Repair shall be carried out only in workshop approved by Accepting Officer. (iv) The qouted rates are also included cost of replacement of old unsv rubber packings.
Note :- Amount of credit of Rs. 126000.00 for retrieved materials is mentioned in Schedule of Credit of tender documents in pdf form which will be deducted offline while acceptance of tender.
MAYANK ENTERPRISES
m/s parmod kamar
Bal Singh and Sons
MAHESH GAUR AND CO.
Raman Electric Trading Co
G M CONSTRUCTION COMPANY
infinity Services
singh traders
M/S VEDHANT ASSOCIATES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .