| 1 | L1₹68.4 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹70.2 L+₹1.3 L (1.90%)Rejected-Finance 606 80 FEET ROAD 7TH BLOCK 2ND PHASE BANASHANKARI 3RD STAGE BANGALORE 560 085 | BANGALORE | BANGALORE | KARNATAKA | 560085 | L2 | Rejected-Finance Higher bid value | |
| 3 | L3₹75.0 L+₹6.1 L (8.84%)Rejected-Finance | L3 | Rejected-Finance Higher bid value | |
| 4 | L4₹82.6 L+₹13.7 L (19.8%)Rejected-Finance JJ BHAVAN TC 10 1378 2 GN 31 CHENCHERY ROAD NALACHIRA PO TRIVANDRUM 695 015 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695015 | L4 | Rejected-Finance Higher bid value | |
| 5 | L5₹89.8 L+₹20.9 L (30.4%)Rejected-Finance | L5 | Rejected-Finance Higher bid value |
Tender Value
₹83.5 L
EMD Value
₹1.5 L
Closing Date
19 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col Bhaskar Jha CWE
CWE Ezhimala INA Ezhimala PO Kannur Kerala 670310
REPAIR/ REPLACEMENT OF HT UG CABLES, POLES, GOD AND CONNECTED HT WORK SERVICES AT INA EZHIMALA
2022_MES_544172_1
80452
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Ezhimala
As per Tender Documents
2 documents required · 2 mandatory
₹1,000
GE(Maint) Ezhimala
₹1.5 L
Yes
18 Oct 2022
8 Aug 2022
21 Sept 2022
8 Aug 2022
19 Sept 2022
2 Sept 2022
10 Aug 2022 - 22 Aug 2022
Amount
Notes for BOQ: (i) Contractor has to visit the site before quoting. (ii) Contractor has to attend/ rectify emergency complaints (expect major complaints) within 24 hrs otherwise a penalty of Rs.2500/- will be levied for delay for the each day. (iii) Cleaning of substation has to be carried out within first week of all month otherwise penalty of Rs 1000/- per substation will be levied.
Material and labour for finding out the faults in HT (11KV) UG cable of size 95Sqmm to 300Sqmm using HT cable fault locator complete all as specified and as directed by Engneer-in-Charge. Note: Cable fault locator should be arranged within 2 days from the date of intimation by Engineer in charge otherwise penalty of Rs. 2000/- per day will be levied for each day of delay for every segment of cable.
Material and labour for cable route tracing in HT (11KV) UG cable of size 95 Sqmm to 300 Sqmm using HT cable Route tracer and marking the route of cable using cable route indicactor at an interval of 35m for a length of 1000 Rm complete all as specified and as directed by Engneer-in-Charge. Note : Cost of cable route indicator deemed to be included in the quoted rate
Dismantling steel poles/ Struts of any type and length complete all as specified and as directed by Engneer-in-Charge.
Taking down old unserviceable overhead ACSR conductor of any type complete all as specified and as directed by Engneer-in-Charge.
Taking down old unserviceable mild steel channel cross arm, clamp, and all accessories complete all as specified and as directed by Engneer-in-Charge.
Taking down unserviceable HT UG cable of size of 95 to 300 sqmm 3core including removing electrical connection and keeping side serviceable cable including removing cable protection cover etc complete all as specified and as directed by Engneer-in-Charge.
Exacavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in hard/ dense soil complete all as specified and as directed by Engneer-in-Charge. Note :- (i) Prior approval of station HQ is to be obtained to avoid loss of other co existing utility services or communication cables. Incase of damage to any utility service or communication cable, the contractor will do the required repair at his own cost. (ii) The excavation has to be done manually only.
All as per serial item No 08 above but depth exceeding 1.5m complete all as specified and as directed by Engneer-in-Charge. Note: The excavation has to be done manually only
Returning and filling in including levelling watering and well ramming into layers not exceeding 25 cm in hard/dense soil complete all as specified and as directed by Engneer-in-Charge.
Removal of excavated soil to a distance not exceeding 50m and depositing at a level not exceeding 1.5m from starting point complete all as specified and as directed by Engneer-in-Charge.
Spreading riddled earth for cushioning and covering of the UG cable in trenches complete all as specified and as directed by Engneer-in-Charge. Note :- Punned thickness only will be measured and paid. (ii) Excavated approved soil shall be riddled by using sieve to separate composite particles as per IS.
Supply and laying un-reinforced precast concrete cable cover class HV type 1 size 300 mm x 180 mm x 40 mm confirming to IS 5820-1970 complete all as specified and as directed by Engneer-in-Charge. Note: Contractor has to produce PCC cable cover test certificate from the manufacturer.
Relaying of cable cover obtained from item No 7 complete all as specified and as directed by Engneer-in-Charge.
Supply, laying, connecting, testing and commissioning PVC underground HT XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 11000 volts Earthed, grade cross sectional area 95 sq. mm 3 core laid in trench/fixing to walls/ pipe/ pole with proper saddles complete all as specified and as directed by Engneer-in-Charge.
All as per Item No 15 above but of size 120 sqmm 3 core complete all as specified and as directed by Engneer-in-Charge.
All as per Item No 15 above but of size 300 sqmm 3 core complete all as specified and as directed by Engneer-in-Charge.
Relaying, connecting, testing and commissioning of serviceable HT cable obtained from serial item No 7 11000 Volts insulated heavy duty galvanised steel strip armoured HT cable of size of 95 to 300 sqmm 3 core laid in trench/ fixing to walls/ pipe/ pole etc with proper saddles complete all as specified and as directed by Engneer-in-Charge.
Material and labour for cutting the existing road/hard standing made of concrete or premix carpet, WBM, soling and moorum filling including excavating for laying the cable/ pipe, width 0.5m and depth 0.7m all as directed and making good the road/ hard standing using pre mix bituminous as required at site to match with the existing surface complete all as specified and as directed by Engneer-in-Charge. NOTE: Before using the hand drilling/ breaker machine diamond cutter will be used all as directed by Engr-in-charge
Supply and fix GI tubing light grade 80 mm nominal dia in trench/road/pole for cable protection confirming to IS 1239-2004 including taking down existing one complete all as specified and as directed by Engneer-in-Charge.
Material and labour for restringing of ACSR/ conductor/ earth wire of any type in overhead lines for any poles and to proper upkeep of and maintaining safe distance between conductors/ spans complete all as specified and as directed by Engneer-in-Charge.
Supply and string ACSR conductor of any type for any poles complete all as specified and as directed by Engneer-in-Charge.
Cutting/ trimming off the tree branches not exc 30cm girth protruding/ touching both sides of the conductor 3m away on both sides of the over head conductor lines of any type on any height and clearing all the unserviceable materials all as specified and as directed by Engr-in-charge.
Material and labour for cleaning the ground inside and around substation (upto 1.5 m from the substation wall ) by clearing all the grass/creepers and clearing all the unserviceable materials and maintenance of Jumper etc with jelly inside the substation complete all as specified and as directed by Engineer-in-Charge.
Supply and fix in replacement GOD handle required at site complete all as specified and as directed by Engr in charge.
Supply and fix lightning arrestor expulsion type complete with all fittings and transmission class discharge capacity 65 kilo amps suitable for 11000v grade. (Each set of three) including taking down existing one complete all as specified and as directed by Engneer-in-Charge.
Dismantling gang operated Air break switch vertical/ horizontal mounted triple pole mechanically operated complete all as specified and as directed by Engneer-in-Charge.
Supply and fix gang operated Air break switch triple pole mechanically operated on insulators and steel frame with operating mechanism worked from ground level for current rating up to 200 amps,11000 volts all as specified and as directed by Engr-in-charge.
Dismantling insulator any type any size complete all as specified and as directed by Engr in charge.
Supply and fix single disc insulator assembly porcelain vitreous 145mm high and 255mm dia ball and socket type including tension clamps for 11000 volt complete all as specified and as directed by Engr-in-charge.
Supply and fix pin insulator porcelain vitreous white, brown or green insulator including one galvanised mild steel straps, washers, insulator bolts, washers and nuts and one galvanised steel nut 150 mm dia 150 mm height suitable for 11000 volts grade all as specified and as directed by Engr-in-charge.
Supply and fix mild steel channel, cross arms bracings supports clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint complete all specified and as directed by Engr-in-Charge.
Demolition of concrete coping/ foundation as per site requirement complete all as specified and as directed by Engr in charge.
Material and labour for mass filling in foundation/ coping/ wall with PCC 1:3:6 using 40 mm graded aggregate type C2 as per site requirement complete all as specified and as directed by Engr in charge
Supply and fix 11KV HT drop out fuse units complete with all accessories including insulator and steel frame etc.(Each set of three) including taking down existing one complete all as specified and as directed by Engr in charge.
Supply and spread granite trap or basalt course aggregate of size 50mm to 20mm grade for the outdoor substation/ structures/ RMU after levelling the existing surface complete all as specified and as directed by Engr in charge.
Supply and fix route indicator for marking of HT UG cable of any size with cast iron round plate of 150 mm dia suitably fitted on iron and embedded with PCC block including taking down existing one complete all as specified and as directed by Engr in charge.
Dismantling of stay assembly complete all as specified and as directed by Engr in charge. (Demolition of concrete etc and excavation shall be measured and paid separately)
Supply and fix stay assembly (dia of stay assembly 20mm) complete with all accessories as shown in electrical plate No 1 of SSR Part-1 complete all as specified and as directed by Engr-in-charge. (Excavation and concrete shall be measured and paid separately)
Supply and fix in replacement of insulating mat of size 2m x 1m x 2.5mm thick complete all as specified and as directed by Engr in charge.
Supply and fix in replacement of compressing/ crimping type sleeve joints for jointing conductor/ jumper connections including treatment with conducting jelly up to 10mm dia complete all as specified and as directed by Engineer-in-Charge.
Material and labour for scrapping out the faded/ rusted old paint from the poles using wire brush, emery paper, and prepare the Surface for painting, applying one coat of aluminium paint on the poles including, cross arm, clamps, bolts and nuts, anti-climbing device etc and writing the existing poles number with black paint over a yellow base after painting all as specified for any poles of height upto 11m with white cement paint for coping complete all as specified and as directed by Engr in Charge.
Material and labour for scrapping out the faded/ rusted old paint from the Four Pole Structure using wire brush, emery paper, and prepare the Surface for painting, applying one coat of aluminium paint on the poles including, cross arm, clamps, bolts and nuts, anti-climbing device etc and writing the existing poles number with black paint over a yellow base after painting all as specified for HT poles complete all as specified and as directed by Enger in charge.
Material and labour for scrapping out the faded/ rusted old paint from the Two pole structure using wire brush, emery paper, and prepare the Surface for painting, applying one coat of aluminium paint on the poles including, cross arm, clamps, bolts and nuts, anti-climbing device etc and writing the existing poles number with black paint over a yellow base after painting all as specified for HT poles complete all as specified and as directed by Enger in charge.
Supply and erect steel tubular swaged pole type 410SP 55(11m long) complete with CI base plate including 3 coat of bituminous paint for the embedded portion and two coat of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
Supply and erect steel tubular swaged pole type 410SP-31(9m long) complete with CI base plate including 3 coat of bituminous paint for the embedded portion and two coat of aluminium paint over a coat of red oxide primer complete all as specified and as directed by Engineer-in-Charge.
Supply and joint cable end termination joint, heat shrinkable type, suitable for 3 core 95sqmm, HT 11 KV (Earthed) XLPE, insulated cable, outdoor type with all connected accessories and jointing materials complete all as specified and as directed by Engineer-in-Charge.
All as per item No 47 above but indoor use complete all as specified and as directed by Engineer-in-Charge.
Supply and joint cable end termination joint, heat shrinkable type, suitable for 3 core 300sqmm, HT 11 KV (Earthed) XLPE, insulated cable, outdoor type with all connected accessories and jointing materials complete all as specified and as directed by Engineer-in-Charge.
All as per item No 49 above but indoor use complete all as specified and as directed by Engineer-in-Charge.
Supply and joint cable end termination joint, heat shrinkable type, suitable for 3 core 120sqmm, HT 11 KV (Earthed) XLPE, insulated cable, outdoor type with all connected accessories and jointing materials complete all as specified and as directed by Engineer-in-Charge.
Supply and joint the cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm complete all as specified and as directed by Engineer-in-Charge.
All as per item no 52 above but of size 300 sqmm complete all as specified and as directed by Engineer-in-Charge.
All as per item no 52 above but of size 120 sqmm complete all as specified and as directed by Engineer-in-Charge.
Material and labour for servicing existing GOD by aligning and applying grease on all joints and moving parts and making it operational from ground level complete all as specified and as directed by Engineer-in-Charge.
Material and labour for cleaning the around two pole/ four pole/ RMU/ LT panel/ upto 1.5m in all sides by clearing all the grass/ creepers and clearing all the unserviceable material complete all as specified and as directed by Engneer-in-Charge.
Supply and fix acrlic sign board of size 90cm x 60cm with steel frame in the wall of substation using necessary fixtures with name of the installation, capacity and organisation clearly written using white fonts in blue background including taking down existing one complete all as specified and as directed by Engr-in-charge.
Supply, fabrication and fix chequered plate suitable for cable trench made out of 7mm thick steel sheet fitted with suitable angle iron support as per site requirement including taking down existing one complete all as specified and as directed by Engr-in-charge.
Supply and fix outdoor type right angled elastomeric reusable insulating boot ( set of three) for bushings up to 17.5kv (cable Boot) suitable for 11KV HT cable of size upto 300 Sqmm including taking down existing one complete all as specified and directed by Engr-in-charge
Material and labour for earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground(earth pit not less than 2.25m below normal ground level) with top edge of the plate not less than 1.5m below normal GL, connected to and including galvanized earth lead strip of size 32mm x 6mm upto 7.5m distance and connected to earthing test point by means of bolts, nuts, checknuts and washers of galvanized iron all as shown in electrical plate No 3 of SSR Part-1 and including excavation, earth work in any strata, charcoal, salt , PCC chamber, 20mm thick RCC cover (Grade M-15) complete having suitable handle (10mm MS Rod), 20 mm dia medium grade GI pipe for watering with GI funnel & wire mesh and 40mm bore GI pipe light grade for protection of earth lead conductor with testing and connecting up complete all as specified and directed by engr-in-charge.
All as per item No 60 above but using copper plate 60cm x 60 cm x 3.15 mm thick electrode and 20mm x 3 mm copper strip as earthing lead complete all as specified and as directed by Engr-in-charge
Supply and fix HT bus supporting insulator for HT 11 KV VCB 630/ 400Amps as per size requirement including taking down the existing, complete all as specified and as directed by Engineer-in-Charge
Supply and fix in replacement of spout for 11KV VCB and Bus Bar side as on site carrying part complete all as specified and directed by Engineer-in-Charge Make : CG/ Areva or eqivalent
Supply and fix earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as 32mm x 6mm galvanised steel strip including taking down existing one complete all as specified and as directed by Engr-in-charge.
All as per item No. 64 above but 20mm x 3mm copper strip. All as specified and as directed by Engr-in-charge.
Material and labour for mass filling in cement concrete in foundation/ coping/ wall with PCC 1:4:8 using 40 mm graded stone aggregate type D2 as per site requirement complete all as specified and as directed by Engr-in-charge.
LUCKY ENTERPRISES
TAMS ASSOCIATES
JEETH CONSTRUCTION
LAKSHMI BUILDERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .