Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Tender Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.2 LAccepted-AOC PLOT NO 46 WARD NO 08 OPPOSITE RADIO TOWER SAGAR ROAD TILAK NAGAR BIKANER 334003 RAJ | BIKANER | BIKANER | RAJASTHAN | 334003 | L1 | Accepted-AOC L1 | |
| 2 | L2₹46.0 L+₹4.4 L (10.6%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹48.4 L+₹6.8 L (16.4%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹63.1 L+₹21.5 L (51.6%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹43.5 L
EMD Value
₹87,000
Closing Date
14 Aug 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) No 02 Jodhpur
GE (AF) No 02 Jodhpur
ADDITIONAL/ ALTERATION AND IMPROVEMENT TO LIVING IN ACCOMMODATION FOR AGNIVEER (VAYU) AT AF STN JODHPUR
2023_MES_609641_1
8419/E8
Open Tender
Civil Works
Item Rate
90 days
GE (AF) No 02 Jodhpur
7 documents required · 7 mandatory
₹500
GE (AF) No 02 Jodhpur
₹87,000
Yes
5 Sept 2023
18 Jul 2023
16 Aug 2023
18 Jul 2023
14 Aug 2023
2 Aug 2023
18 Jul 2023 - 24 Jul 2023
Amount
M&L for demolitation of cement concrete of any description and in any position not otherwise specifically provided for and complete all as specified.
M&L for cement concrete type B-1, 75 mm thick 1:2:4 (20mm graded aggregate) for finishing cement concrete surface even and smooth without using extra cement for plinth protection, path and complete all as specified.
M&L for Machine pressed pecast cement concrete interlocking paver paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness in M-35 grade rubberised with grey cement and pigment and complete all as specified.
M&L Cement concrete type D-2, 75 mm thick 1:4:8 (40 mm graded aggregate) and complete all as specified.
M&L for sand filling under floors or in foundations including watering and consolidation and complete all as specified.
M&L for dismantling floor heart or wall tiling including cement mortar bedding (but not backing) and rubbish off the premises and com[plete all as specified.
M&L Cement concrete type B-0, 25 mm thick 1:2:4 (12.5 mm graded aggregate) as sub base complete all as specified.
M&L for coloured Non Skid coloured ceramic tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match thick over cement screed 15mm thick in cement mortor 1:6 laid and jointed complete.
M&L for coloured glazed ceramic coloured tiles of size 350x 250x 7mm/450x350x7mm thick on walls/vertical surfaces including 10mm thick rendering in CM 1:4, all as directed.
M&L for machine cut Kota stone slab flooring 20-25 mm thick over 15 mm thick screed in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L for machine cut Kota stone slab 20-25 mm thick on skirting, dado over 10 mm thick rendering in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified.
M&L Taking down cement or cement lime plaster of any description on brick or stone walls etc. including raking out joints, hacking for key, scrubbing down with water etc and complete all as specified
M& L for 15 mm thick rendering on stone masonary in CM 1:3 on Ceilings on a floating/setting coat for additional thickness using integral water proofing compound , finished even and smooth without using extra cement and all as specified. Note:- Water proofing compound shall be measured and paid seperately
M& L for 15 mm thick rendering on stone masonary in CM 1:6 on walls using , finished even and smooth without using extra cement complete all as specified.
Taking down old existing roof treatment (APP membrane & plaster ) and removing outside MOD and cleaning of roof slab / chajjas sweeping with brooms removing all loose materials debris etc complete all as specified and as directed by Engr-in-charge
Cutting out cracks to V section in existing roof or terrace cleaning out wetting / grouting with cement and sand slurry 1:3 complete all as specified and as directed by Engr-In-charge
M&L for 50 mm thick (average) cement concrete type B-1, 1:2:4 (20mm graded aggregate) in padding over roof complete all as specified and as directed by Engineer-in-Charge.
M&L10 mm thick screed bed with CM 1:4 with water proofing compound @ 3% by weight of cement finish even and smooth surfaces using without extra cement. Note :-Water proofing compound shall be measured and paid seperately
M&L for applying oil based bituminous primer @ 0.5 kg/Sqm complete all as specified and directed.
M&L for providing APP based polymeric membrane minimum weighing 3Kg/sqm and minimum 3 mm thick reinforced with polyster non wave fabric (wt. not less than 150 gms/sqm) land on primed surfaced by torche application and complete all as specified and as directed by Engr-in-charge (Note : Quoted rate shall deemed to be included for work in building / structure of any height)
Supply only integral water proofing compound.
Material and labour for preparing new surfaces of roof and applying two coats of Polyurethene (PU) acrylic based Water proofing liquid compound over and including a coat of diluted elastomeric self primer and reinforcement fabric sheet as per manufacturer's instruction to stop leakage/seepage from roof/wall complete all as specified and directed by the Engineer-in-Charge. Note :- Quoted rate shall be deemed to be included for work in buildings/ structure of any height.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 15 mm.
Taking up or down steel tubing and connection including cleaning for refixing or removal to store yard of bore 20 mm.
S & F 15 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
S & F 20 mm dia galvanized steel tubing, medium grade, with all fitting and fixed complete to walls celling or laid in floors all as specified and directed.
S&F in repair Gun metal globe or gate valves with iron wheel head, screwed both ends for iron pipe of 20 mm dia.
S&F in repairs vitreous China squatting pan, ‘Orissa’ pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) all as specified and directed.
S&F in repairs vitreous- Vitreous China wash down water closet pan (pedestal pattern), white (excluding fixing bolts, flushing cistern and flush pipe) all as specified and directed.
S&F in repair vitreous china WHB white,flat back, size 450 x 300mm including brackets. vitreous china(flat black or angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand but exclusive of fixing of supply and waste pipe, all as specified and directed.
S&F in repairs Urinal, bowl type or half stall pattern, (excluding flushing cistern and flush pipe) but including waste pipe fixed as in repair complete all as specified.
S&F in repair 15 mm angle/stop valve, fancy type,chromium plated with screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
S&F as in repair 15 mm angle/stop valve, fancy type,chromium plated with long shank and cup (Concealed type) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
S&F in repair 15mm bib taps cast copper alloy CP with crutch or butterfly handle screwed down for iron pipe or for brass ferrule all as specified and directed.
S & F in repair 15 mm pillar tap cast copper aloy with capston heads chromium plated screwed down fly nuts screwed for iron pipe or for brass ferrule and fixed complete all as specified.
S&F in repairs 15 mm bore two- in- one bib taps, cast copper alloy, chromium plated, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule.
S&F in repairs of flushing cistern PVC 10 ltrs cap valve less syphonic action type, low level white with intel , ball valve , float incl brackets and PVC flush pipe 32mm dia complete all as specified. .
S&F in repairs health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 mtr long flexble tube ABS wall hook including making connections and fixed complete in all respect as specified
S&F in repair Brass chromium plated shower rose 125mm size all as specified and directed.
S&F in repairs PVC connections 15mm size with PTMT nuts of length 450mm all as specified and directed.
S & F PVC waste pipe 32mm bore and 1000/900 mm long for WHB all as specified and as directed
S&F in repair CP soap dish, fixed to plugs with chromium plated screws and all as specified.
S&F in repair CP grating 100 mm dia all as specified and as directed.
S&F in repair CP tubular towel rail, 20 mm dia, D type, 60 cm long between flanges and all as specified
S&F in repair shelf of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 300 gms) and all as specified and as directed.
S & F Plastic water closet seat, black or white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
Dismantling of existing water tank (PVC/RCC/AC) n exc 500 ltr capcity and removing from site complete as directed by Engr -in-charge.
Dismantling of existing water tank (PVC/RCC/AC) exc 500 ltr but n exc 1000 ltr capcity and removing from site complete as directed by Engr -in-charge.
S&F 500 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) (ISI mark) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete in repair.
S&F 1000 ltr capacity rotational moulded polyethylene water storage tanks (cylindrical vertical with closed top) (ISI mark) hoisted and fixed in position incl 20mm bore ball PTMT. valve high pressure with polythyne float and flynut complete in repair.
Demolition and breaking up drain pipes (Salt glazed ware, AC or Reinforced concrete) set in cement mortar of 100 mm dia
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F PVC (SWR) pipes 110 mm dia single socketed, in any length with rubber ring joints fixed in walls including brackets and complete all as specified.
S&F PVC (SWR), junction single, (Single T) with acess door 110 mm dia equal or unequal
S&F PVC (SWR) door bends 110 mm dia
S&F PVC (SWR) Vent Cowl 110 mm dia
S&F PVC (SWR) 'S' trap 110 mm dia
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints laid in trenches or in floors
S&F PVC (SWR) pipes 75 mm dia single socketed, in any length with rubber ring joints fixed in walls including brackets and complete all as specified.
S&F PVC (SWR), junction single, (Single T) with acess door 75 mm dia equal or unequal
S&F PVC (SWR) door bends 75 mm dia
S&F PVC (SWR) Vent Cowl 75 mm dia
S&F PVC (SWR) floor trap of outlet dia 75mm incl jointing with solvent cement
S & F in repairs 110 mm PVC (SWR) clamps including all necessary fixing accessaries and securing ends of stays to wall or roof all as specified & directed.
S & F in repairs 75 mm PVC (SWR) clamps including all necessary fixing accessaries and securing ends of stays to wall or roof all as specified & directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and removing from site.Note-Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) exceeding 1.5 sqm each but n.exc 4.5 sqm eachand removing from site.Note-Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
M&L PCC 1:3:6 type C1 using 20mm graded stone aggregate as in bed blocks etc for embedding hold fasts complete all as specified and directed by Engineer-in-Charge
Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S Square tube, supplying & fixing in opening as per specified and directed
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, supplying & fixing in the frame at site as per specified and directed
S&F 35 mm thick factory made, second class hard wood, plain framed, panelled shutter (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 (Part I), kiln seasoned and chemically pressure treated.
M/L for Glazed and skeleton shutters of thickness 35mm of IInd class hard wood , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats note: Glazed or clothetc in panelsor sash square shall be measured seperately
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with glazing bars dovetailed or welded.
S&F steel windows with side hung shutters including projecting type hinges with steel handle and steel peg stay, complete with out glazing bars dovetailed or welded.
M&L for powder coated anodised aluminium frame for door window & ventilator with one or more rebates including joining cleat for fixing etc comlete all as specified.
S&F metalic louvers slits to hold glass strip of size 300x500 mm with including arrangement of fixing glass pinhead as per size & louvers ventilator (Glass shall be measurement separately) complete all as specified and as diredcted.
S&F rolled mild steel of grade Fe-290 (Grade E-165) in rolled section as in frames for doors/windows, framing for cladding, glazing and the like fixed with angle cleats and connecting plates, etc.
S&F in repairs Aluminium anodised barrel tower bolt of extruded section 200mm size
S&F Aluminium anodised barrel tower bolt of extruded section 200mm size
S&F in Aluminium anodised barrel tower bolt of extruded section 150mm size
S&F in Butt hinges 100 mm, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed complete.
S&F in Butt hinges,heavy weight cold rolled mild steel of size 125 mm.
S&F in repairs extructed aluminium alloy handles, fabricated type,anodised of size 150mm.
S&F in extructed aluminium alloy handles, fabricated type,anodised of size 150mm.
S & F Aluminium alloy, anodised, 300mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S & F in repairs Aluminium alloy, anodised,300mm sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed
S&F in repairs galvanised mild steel wire cloth, 0.56 nominal dia of wire and average width of aperture 1.00 mm and fixed with tinned tacks or galvanised wire staples
S&F stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified.
S&F in repairs floor door stopper, with 150 mm long cover plate, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor.
S&F floor door stopper, with 150 mm long cover plate, of aluminium alloy body and tongue, anodized, with hard drawn steel spring, fixed in floor.
S&F in repair MS peg set with 3 to 5 hooks fixed to doors/wall with screws.
S&F in solid rubber beading of 30 to 50 mm wide and 3 to 5 mm thick fixing at bottom to existing doors all as directed by Engineer-in-Charge.
S&F in repairs peg stay 250 mm/300 mm long stopping of steel window/ventilators including welding(if required) & fixing complete all as directed by Engr-in-charge.
S&F in repairs left/right MS handle of steel windows including welding(if required) & fixing complete all as directed by Engr-in-charge.
S&F in repair MS 300 mm , ordinary rat tail rod pattern springs including rooler and roller plate complete all as specified.
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones.
S&F figured sheet glass 3 mm thick, ordinary quality and glazing with oil putty in square n.exc. 0.5 sqm in each paneand complete all as specified.
S&F figured glass 4 mm thick, pin head type and fixed with aluminium louvers n. Exc 0.5 Sqm in each complete all as specified & diretced.
Taking down chowkats or frames with shutters (without taking off shutters from the frames) not exceeding 1.5 sqm each and refixing in same opening and complete..Note-Quoted rate shall be deemed to be include for cutting holes/demolition of PCC blocks etc for taking down chowkats and making good the damaged surfaces in CM 1:3 all as directed.
Resecuring or easing & adjusting without taking down shutters of any description exc. 1 sqm but n. exc. 2 sqm each.
S & F in repair 25 mm dia MS powder coated curtain rods with fixing brackets etc complete all as specified
M&L for complete removal of existing treatment of walls and applying two coats of cement base paint over a coat of primer, white or tinted, all as directed.
M&L for preparation of new plastered or unplastered surfaces of walls and applying two coats of oil bound distemper over a layer wall care putty, all as directed.
M&L for complete removal of existing treatment of walls and applying two coats of oil bound distemper over a layer of wall care putty all as directed.
M&L for complete removal of existing treatment of ceilings and applying two coats of white washover and , all as directed.
M&L for preparation of new plastered ceilings and applying two coats of white washover and , all as directed.
M&L for preparation of old painted wooden surface of any description not otherwise provided over 10 cm width or girth and applying one coats of synthetic enamel paint and complete.
M&L for preparation of new wooden surface of any description not otherwise provided over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer and complete.
M&L for preparation of old painted steel surface of any description not otherwise provided over 10 cm width or girth and applying one coats of synthetic enamel paint and complete.
M&L for preparation of new steel surface of any description not otherwise provided over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide and complete.
Demolition of stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc. and removing from site all as specified and directed.
M&L for squared rubble walling, jodhpur type brought upto courses, well bonded, bedded and solidly hearted, built in cement mortar 1:4 and complete all as specified and directed.
Excavating in trenches in any type of soil , n.exc. 1.5m wide and n.exc 1.5 in depth, for foundation, etc. or for shafts, wells, cess pits, manholes, pier holes, etc n.exc. 10 sqm on plan and n.exc 1.5m in depth and getting out.
M&L for cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregate as in bed to drain pipes of size 150 mm bore, including packing under & haunching against the sides of pipes after they are laid and tested.
M & L for Salt glazed stone ware drain pipes of 150 mm internal dia. Meter grade “A” laid in trenches and jointed.
M&L for precast cement concrte block masonery with solid block as exc 10 cm in width and setting in cement mortar 1:4 type C1 1:3:6 (20 mm graded aggregate ) complete
M&L for cement concrete (1:4:8) type D2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete all as specified and directed.
M&L for PCC 1:3:6 type C-1 using 20 mm graded stone aggregate in cills, steps, bands, copings, bed plates, blocks for inserting hold fasts etc. and the like including weathering, slightly rounded or chamfered angles and throating as directed.
M&L for cement concrete (1:2:4) type B1 using 20mm graded stone aggregate as in surface channels, drains (forming fair finished channel shall be measured and paid for separately).
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement including forms, moulds mitered/stopped ends, etc all as specified.
M&L for Jodhpur stone roof slabs, self faced 7.5 cm to 10 cm thick, 25 cm to 35 cm wide, hoisted and set, jointed and grouted in cement mortar 1:3 complete as in manhole cover and complete all as specified.
Returning, filling in (soil), including spreading, leveling, watering and well ramming in layers not exc. 25cm.
Cutting into existing manholes for connecting new drains of 150mm internal dia, making good to pipe and rendering, cutting out existing benching for and forming branch channel ( ½ round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required.
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in surface/concealed conduit heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : - Note : Quoted rates deems to be included cost of modular plate for mounting switches, sockets & regulators as required at site. Cutting into chases required for concealing heavy duty (HMS Grade) PVC conduits and making good to damaged surface shall be measured and paid separately under relavant item.
One light / fan point controlled by one switch one way.
One 3 pin 5 Amp switch & socket outlet on same board with other switches.
One 3 pin 5 Amp switch & socket outlet on Independant board.
All same as per item ser No 127.00 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F switch modular single pole one way 16 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Socket modular 6&16 Amp 2/3 pin combined two module.
S&F Stepped type modular electronic fan regulator, socket size, flush type 230V AC.
S&F Ceiling rose surface bakelite 65x50mm three terminal.
S&F Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified.
Taking down carefully Ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, dismantling blades, stacking carfully at site for reuse of serviceable fans complete all as directed and specified.
Fixing only light fitting any type, connecting up with twin core PVC insulated and PVC sheathed flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Note : Serviceable light fittings taken down against item No 01 shall be used at site as directed by engr-in-charge.
Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.
Supply and fixing LED light fitting wall /roof mounted, Aluminium housing, 1 x 9/10 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as per Havells Cat No: ENDURAPEARLSL25W or equivalent model approved makes.
Supply and fixing LED study table light fitting, swivel base, wall mouning type, corrosion resistant, superior finish and including 01 Nos 5 watt LED lamp B-22 Base type, complete all as specified and directed.
NOTES FOR LED LIGHT FITTINGS & BULBS : (i) All LED light/luminare shall meet the provision laid down in IS - 16101, 16102 Part-I/II, 16103 Part-I, 16104, 16105, 16106, 16108/2012 and 15885 Part -II / Section 13. (ii) Contractor shall submit test report of LED street light fitting from Government accredited test laboratory for LM-79 and LM-80. (iii) Contractor has to furnish a replacement warranty of 02 years for LED light fittings complete including lamps from the date of completion of contract. The product will be replaced on site free of cost in the following case :- (a) Manufacturing defects. (b) Failure due to mechanical and electrical impact. (c) Drop in lumen (or lux at 1 m) below 90% of claimed values of lumen (or lux at 1 m) of the LED /Luminaries.
M&L for cutting holes 300mm diameter for preaparing opening through wall for fixing exhaust fan 300mm sweep, making good to damaged surface of wall, make a smooth circular surface and match with specification of existing wall all as directed by Engr-in-charge at site
Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified. NOTE: Fan taken down against item No 16 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleanig of dust etc)
Fixing only exhaust fan 300mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan complete all as specified. NOTE: Exhaust Fan/wall fans taken taken down against item No 16 shall be used after complete civil work repair and minor repair of ceiling fans (like replace of rusted nut bolts, denting of blade, cleanig of dust etc)
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor(BLDC) connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified.
S&F Exhaust fan 300 mm sweep, copper wounded, four blade, metal body, BEE approved/ISI marked, air delivery shall not be less than 230 CFM, mounted in suitable opening arrangement with louvers shutters, suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up using flexible cord wire 3 core using PVC flexible conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified.
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main Phase-Neutral supply cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color.
M&L for Sub main wiring as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Four runs of 6.0 Sq.mm main R-Y-B-N supply cable alongwith two run of single core 6.0 Sq.mm for continuous earth wire in green color.
M&L for channel or grooves cutting upto a depth of 2.5 cm and width not exc 15cm into brick/concrete/stone masonary walls, with or without re-inforcement and trimming surface as required, including concealing PVC conduit 20/25mm dia with required accessories (like junction boxes/bends etc) and plastering in 1:4CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed by engr-in-charge. Note : Rate of PVC Conduit included in relavant point wiring and shall not be paid separately.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
Supply and fix Sheet metal enclosure distribution board TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, 200 Amps rated neutral copper bus bar for housing MCBs, blank plates and including provision for fixing TPN MCB as incommer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification complete including taking out old all as specified all as specified and directed.
M&L for MCB TPN/FP, 63 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for wiring with TV coaxial RG-06, electrolytic grade solid annealed copper conductor having single strand of 0.7 mm dia, PVC insulated, aluminium foiled and aluminium wire braided, overall PVC sheathed cable complete including concealed PVC conduit 20mm dia from TV Socket to dish antena on roof of building complete all as specified. Note : 20mm conduit pipe inside building shall be concealed in wall surface and from external surface duly fixed with GI Saddles is deems to be included in quoted rates.
Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
Supply and laying GI Pipe 15 mm dia, light grade for protection of GI Earth wire 4.0mm dia complete all as specified & directed. Note : Quoted rate deems to be include cost of GI Saddle used for fixing GI pipe on wall by using screw and guttis not exceeding distance 0.6mtr.
M&L for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4.0mm dia galvanised iron or steel wire all as specified.
Savitri Enterprises
Nikhat nirman
Siddharth Constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .