| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹35.5 L+₹75,827 (2.18%)Rejected-AOC CHANGANACHERRY GENERAL ELECTRICAL WORK | ERNAKULAM | KERALA | 682001 | L2 | Rejected-AOC second lowest | |
| 3 | L3₹40.7 L+₹6.0 L (17.1%)Rejected-AOC | L3 | Rejected-AOC third lowest |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
23 Mar 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
PWD ELECTRICAL DIVISION THRISSUR
DEPOSIT Installation of 500 KVA Outdoor U S S a t G o v t P o l y t e c h n i c C o l l e g e Kalamassery Ernakulam Installation of 500 KVA Outdoor USS at Govt Polytechnic College Kalamassery Ernakulam General Electrical Work
2024_PWD_670982_1
PWD/BLDG/16607/2023-2024
Open Tender
Electrical Works
Item Rate
180 days
Ernakulam
Please refer Tender documents.
9 documents required · 9 mandatory
₹2,760
₹50,000
24 Jun 2024
16 Mar 2024
26 Mar 2024
16 Mar 2024
23 Mar 2024
16 Mar 2024
Amount
OUTDOOR USS
OD127354/2021-2022:Disconnect the 11 KV / 433 supply from the existing 11 KV structure of 315 KVA transformer yard , dismantle the damaged AB switch , insulators , CT PT unit , cross arms , DO fuse units , transformer etc.Demolishing the concrete foundation of 10 metre A type pole, cutting the base portion of the pole by using gas cutter and safely bring down to ground . Remove the poles and other accessories from the yard and stack at safe place including transformer
OD127414/2021-2022:Supply and providing new 2 pole structure with 2Nos 10mtr A pole structure and required accessories such as G.I cross arms, of minimum 50x50x5 mm size. 11KV 45KN disc insulators, 11 KV pin type insulators, 11KV, 400A AB switchs, lightning arresters and required all accessories and duly painted the same and giving necessary connection ect as reuired.
OD127458/2021-2022:Supply, conveyance, installation, testing and commissioning of 500 KVA Out Door type unitized substation of IP class 54, with cast resin Transformer with 630A VCB on H.T.side, and Metering CT and PT ,with Top/bottom entry cable box and provision for providing TOD meter The LT Portion Shall include 800A ACB with CT and Relays as required as per Electrical inspectorate standards on L.T. side. Transformer Portion consists of 500 KVA , 11 K.V, 50 Hz, Delta/Star connected cast resin insulated copper wound transformer. The core shall be made of high grade grain oriented silicon M4 steel lamination insulated and oxide layer and outside of the core shall be protected against corrosion by epoxy resin finish. Class 'F' insulation level shall be maintained. OFF load tap changing facility shall be incorporated so as to achieve tap positions of +5% to -10% in step of 2.5%. four channel Temperature Scanner with 4 nos Sensors, annunciator and trip mechanism shall be provided. The Transformer shall conform to IEC 726 & IS 11171/1985 re-affirmed in 1991. The maximum allowable loss limited to values designated by ECBC Norms 2007 . All inter connection from HT Side to transformer and to LT Side shall be given using electrolytic copper bus bar insulated with heat shrink sleeves and tinned at the point of contacts. All internal earth connections are to be given as per standards. Necessary protection shall be made for giving cable connections on the HT side as well as LT side. Phase barriers and shrouding as per rules has to be given. The enclosure shall be fabricated from 2.00mm CRCA sheet, complying with of IP 54 standards and shall be powder coated over a coat of Zinc chromate primer after seven tank processing and phosphatizing. The USS shall be installed as per the directions at site.
OD129386/2021-2022:Supply and installation of HT TOD meter of accuracy class .2 s with necessary test terminal block (L&T or equivalent make)
90.14.5:Supply and fabrication conveyance and installation of angle iron frame work for wall mounting panel board
OD129519/2021-2022:Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc,as required, In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works, for HT fencing
OD129544/2021-2022:Supply and providing 12 SWG HT GI fencing net for securing the HT transformer yard.
OD129597/2021-2022:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 11 KV grade of the following sizes in the existing masonry open duct as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments
OD129752/2021-2022:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 11KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required. 3 core 300 sqm stranded compact circular aluminium conductor, conductors screened with extruded semi conducting compound XLPE insulated, insulation screened with extruded semi conducting compound in combination with copper tape (0.3KA for I sec.) cores laid up. inner sheath of PVC tape, galvanized steel flat strip armoured, and overall PVC sheathed cable conforming to IS: 7098 part II 1985 with latest amendments
10.4.4:Supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required:300 sq. mm
90.12.9.7:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench120/102.5 mm or nearest size
10.5.4:Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :300 sq. mm
90.12.12.13:Supply & laying of DWC pipe in ordinary soil 1.2 m below ground level including excavation200/174 mm or nearest size
90.12.5.35:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.3.5 core 240 sq mm
90.12.6.35:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 240 sq mm
9.1.29:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 240 sq. mm (62mm)
OD129905/2021-2022:Providing and laying in position graded stone aggregate 40 mm nominal size in transformer yard etc as required
OD129943/2021-2022:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD129987/2021-2022:Providing and fixing 25 mm X 3 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required
OD130023/2021-2022:Supply and laying of the following sizes of B class GI pipe laid 0.6 m below ground level including excavating trench of suitable size and refilling etc, as required. 25.mm dia. G.I pipe ( medium class)
OD97719/2022-2023:Earthing with G.I. earth plate 1200mm X 1200 mm X 12.5mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
OD130237/2021-2022:Charges for the Preparation of additional copy Schematic diagram per A3 sheet
OD130238/2021-2022:Charges for preparation of Electrical Schematic diagram per A3 sheet for first copy,
14.1:Excavation for foundation in soft soil including dressing of sides and ramming of bottoms, lift upto 1.5 m including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 metres.
14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required.
14.9:Providing and laying in position cement concrete 1 :3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc. including form work etc. as required.
OD97722/2022-2023:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of red oxide and written with white paint
OD97723/2022-2023:Supply and providing DCP type fire extinguisher 5kg capacity with installation brackets conforming to IS 15222 as required
OD97724/2022-2023:Supply and providing 2.00 mm thick 3.3KV fire retardant insulating mat in position
APFC Panal
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.2.1:Supply and providing 2mm SMC sheet as shrouding for bus interconnection / terminations etc. including required nut & bolt etc.
90.14.3.2:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardU' section rubber beeding suitable for 1.60/ 2.00 mm sheet
90.14.4:Supply and fabrication conveyance and installation of base frame of panel board using 75 x 40 mm rolled steel channel (ISMC)
90.14.6:Supply and providing copper bus bars including finger type SMC bus bar supports in the bus chamber, suitable size nut & bolt, providng heat shrink sleeves etc. as required.
90.14.7:Supply and providing copper earth bus in the panel board
90.14.10.12:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.160A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC
90.14.11.13:MCCB AccessoriesSupply and fixing rotary handle, External type (including BUC handle with door interlock ) in the existing MCCB of rating up to 250 A
2.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
OD130245/2021-2022:Supplying and fixing LED indicators for all Voltage ranges- Red Green Black Yellow or Orange Colour
OD134506/2021-2022:Supplying and fixing 40 amps to 63 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
OD130251/2021-2022:Supplying and fixing LED indicators for all Voltage ranges- Blue Colour
OD130256/2021-2022:Providing and fixing following multi function meter to read: V, A, F, 3 phase accuracy class 1 in existing panel and giving connection complete
OD130257/2021-2022:Supply and providing 8 stage 440 / 110 V 5A/1A , Intelligent Power Factor Controllers (IPFC)
OD130258/2021-2022:100/5 A, 5 VA, accuracy class 0.5, Resin Cast Metering CT
OD130266/2021-2022:Supply and Fixing of Bakelite Fuse Base 20A with HRC Fuse Link 2A and giving connection as required
OD130267/2021-2022:Supply and providing reputed make AC cooling fan size 120x120x38 mm, in the existing panel board and giving connection
OD130268/2021-2022:Supply & fixing the3 Pole Capacitor duty contactors for switching capacitor banks 4 - 7 kVAR with AC Coil
OD130275/2021-2022:Supply & fixing the3 Pole Capacitor duty contactors for switching capacitor banks 50 kVAR with AC Coil,
OD130276/2021-2022:Supply & fixing the3 Pole Capacitor duty contractors for switching capacitor banks 20-25 kVAR with AC Coil
90.14.24.66:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.75:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.25 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.78:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.50 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.68:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.5 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
90.14.24.74:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.20 KVAr, 3 phase, 520 V, Metalised Poly Propylene Heavy duty, Box type resin filled Capacitor suitable for APFC panel with block reactor.
OD130454/2021-2022:Supply and fixing of Spreader/Terminal adapter Kit Extended terminal for 3 pole MCCB of rating upto 160 A (6 pcs) and giving connection etc as required.
OD130455/2021-2022:Supply and fixing 500/ 5 A,10 VA, 10 P 5, tape wound protection CT
OD130456/2021-2022:Supply and fixing Flush head Push Button
90.12.7.32:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 120 sq mm
90.12.6.32:Supply & laying of one No. PVC insulated and PVC sheathed armoured aluminium power cable of 1.1 KV grade of the following sizes in the existing masonry open duct as required.3.5 core 120 sq mm
90.6.4.1:Supply and drawing 650/1100 V grade FRLS PVC insulated stranded single core copper conductor cables conforming to IS 694 part I 1990 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.1.00 sq.mm 1 Run
1.17.29:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 6 sq. mm
1.7.4:Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required2 X 6 sq. mm + 1 X 6 sq. mm earth wire
OD130462/2021-2022:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD130463/2021-2022:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD130464/2021-2022:Painting with synthetic enamel paint of approved brand and manufacture to give an even shade
OD130473/2021-2022:Supplying, laying and jointing of the following sizes of double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ground in the existing trench >>120/102.5 mm or nearest size
OD130474/2021-2022:Supply and installation of CO2 type fire extinguisher 4.5kg capacity and installing with suitable clamps as required
OD130475/2021-2022:Supply and providing First Aid Chart duly framed and placed in a conspicuous location for clear vision.
OD130519/2021-2022:Supply and providing 9 Litre capacity GI Fire Bucket painted in post office red with primer coat of redoxide and written with white paint 'FIRE', filled with fine sand, mounted on existing MS angle frame work / wall bracket etc. as required.
OD130527/2021-2022:Supply and providing 2.5 mm thick & 1 m wide synthetic pvc fire retardant insulating sheet to withstand 11 KV dielectric strength conforming to IS .
ELCON ELECTRICALS
Biju E.M
Bidder Name
Biju E.M
Kittu Electricals private limited
ELCON ELECTRICALS
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .