ASSISTANT ENGINEER
ASSISTANT ENGINEER LID EW CHERUPUZHA G P
Annual Plan Project No S0308 25 Motor Replacement of Chattivayal Drinking Water Project Providing New Motor General Electrical Work
2025_LSGD_733471_5
05/24-25
Open Tender
Electrical Works
Item Rate
90 days
LID EW CHERUPUZHA G P
Please refer Tender documents.
8 documents required · 8 mandatory
₹555
Yes
₹3,093
Yes
1 Jul 2025
3 Feb 2025
13 Feb 2025
3 Feb 2025
12 Feb 2025
4 Feb 2025
3 Feb 2025 - 5 Feb 2025
Amount
Providing 5 HP motor
OD368277/2024-2025:Supply, conveyance, erection, testing and commissiong of 5HP 3Phase Monoblock/Open well submersible motor with discharge range upto 846LPM at a total head upto 28m of Kirloskar make (Model No:- Kirloskar KOS-527 Open well submersible Pump) or any other equivalent make of CRI or Texmo including giving connections etc as required.
OD368275/2024-2025:Fabrication, supply, conveyance, installation, testing and commissioning of floor or wall mounting, dust and vermin proof industrial type MV panel board made of 1.63mm CRCA sheet of size not less than 1.2m x 1m on suitable angle iron frame work with suitable holes, gromet washers for cable/wire entry for installing following components/ devices & complying to IS 8623.
OD368278/2024-2025:Supply and fixing L&T make MK1 type or any other equivalent make DOL starter suitable for 5HP openwell submersible motor pump with suitable over load and under voltage relay, dry running preventor etc on exisitng or proposed board including giving connections as required.
90.14.24.3:Supply & fixing the following Power Capacitors 3 phase delta connected in positon and giving connection.3 KVAr, 3 phase, 440 V, delta connected standard duty Metalised Poly Propylene Capacitor, Cylinderical Type suitable for direct connection to motors.
1.58:Supplying and fixing PVC batten/ angle holder including connection etc. as required.
OD368280/2024-2025:supply and fixing of 10W incandescent indicator lamp in existing batten holder of make, philips, osram, syska.
OD368283/2024-2025:Supply and fixing 50mm dia or nearest available size High Density water Pipes of pressure 10kg/cm2 or equivalent along with all required accessories such as GI/SS hose nipple, hose collar, hose clamp, GI bend etc with heavy duty clamps as per site requirement including conveyance and providing supports wherever necessary.
OD368274/2024-2025:Supply and providing 63 mm or nearest size GM non return valve vertical/ horizontal with accessories/ adaptor/ coupling/ nipple in the delivary line as per site condition
OD369221/2024-2025:Supply and providing 63mm mm or nearest size air release valve with accessories/ adaptor/ coupling/ nipple/ T/ bend in the delivary line as per site condition.
OD368285/2024-2025:Supply & Providing Tindx/yellow danline rope for submersible motor pump of size not less than 12mm dia.
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.4:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.40 mm
OD368284/2024-2025:Supply and providing 50mm GI pipe for support to suspend the proposed motors and plastic rope to be laid across the parapet of the well with necessary clamps.
1.17.33:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 6 sq. mm
2.3.3:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 way, Double door
2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
OD368286/2024-2025:Supplying and fixing 40 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Four Pole
OD368276/2024-2025:Supply and fixing 63A FP on load Change over switch in the SS enclosure including giving connections etc as required.
90.6.6.3:Supply and drawing FRLS PVC insulated & sheathed 650/1100 V grade 3 core copper conductor flat cable for submersible pump motor conforming to IS 694 part I 1990 as required including giving necessary connections of the following sizes.4 sq mm
5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD368281/2024-2025:Supply and providing the following 25 x 3 mm brass bolt & nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623. Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame)
90.14.3.1:Supply and providing heavy duty 'A' section neoprene gasket in the panel boardA' section neoprene beeding suitable for 1.60/ 2.00 mm sheet
2.1.2:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.63 Amp TP & N
OD368287/2024-2025:Supplying and fixing 63A, HRC Fuse with HRC Fuse Link with connections, in existing meter board
OD368279/2024-2025:Supplying and fixing 63A, 2way Neutral Link mounted on DMC/SMC base with connections, in existing meter board
PRAKASAN (BID ID -2102825)
Bidder Name
PRAKASAN
Siju C K
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1172711.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .