Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹83.6 LAccepted-AOC 344 1 SB GORAI ROAD HILL VIEW PARK NORTH ASANSOL | ASANSOL | WEST BENGAL | L1 | Accepted-AOC lowest | |
| 2 | L2₹84.1 L+₹53,457 (0.64%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹84.3 L+₹66,985.12 (0.80%)Rejected-Finance 18 SANKAR BOSE ROAD KOLKATA | L3 | Rejected-Finance 3rd lowest | |
| 4 | L4₹84.4 L+₹86,022.93 (1.03%)Rejected-Finance 6 KRIPANATH DUTTA ROAD KOLKATA 700 002 | KOLKATA | KOLKATA | WEST BENGAL | 700002 | L4 | Rejected-Finance 4th lowest |
Tender Value
Refer Docs
EMD Value
₹1.7 L
Closing Date
20 Mar 2024, 11:00 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Executive Engineer, PMD,PHE.Dte
Office of the Executive Engineer Purulia Mechanical Division,PHE.Dte Ranchi Road,Purulia.
Defixing the existing idle unit and supply delivery and installation of Electro-Magnetic Flow Meter with cable and remote display unit at different site of WTP. Intake OHR inlet and Outlet pipeline at Forest premises ... Raghunathpur water supply
2024_PHED_674701_8
21/ EE/PMD/PHED OF 2023-2024
Open Tender
MECHANICAL
Item Rate
120 days
Purulia
Please refer Tender documents.
5 documents required · 5 mandatory
₹1.7 L
Yes
18 Sept 2024
29 Feb 2024
22 Mar 2024
29 Feb 2024
20 Mar 2024
29 Feb 2024
Amount
supply of DN 50 Electro-Magnetic Flow Meter with 20-Mtr Cable Make: As per PHE vendor list Full Bore Electromagnetic Flowmeter - 50 mm - Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05cu.m /Pulse) With LCD backlit Display, Calibration lab as per ISO 17025, Accuracy: 0.5%, +/- 2mm/sec, Measuring, Reference & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner,Supply: 24V DC or 230VAC Full Bore Electromagnetic Flowmeter- 80 mm premises and at WTP at Garpanchakot Forest Bungalow premises.
supply of DN 80 Electro-Magnetic Flow Meter with 20-Mtr Cable Make: As per PHE vendor list Full Bore Electromagnetic Flowmeter: Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05cu.m /Pulse) With LCD backlit Display, Calibration lab as per ISO 17025, Accuracy: 0.5%, +/- 2mm/sec, Measuring, Reference & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner,Supply: 24V DC or 230VAC at WBSEDCL office premises and at WTP
supply of DN 100 Electro-Magnetic Flow Meter with 20-Mtr Cable Make: As per PHE vendor list Full Bore Electromagnetic Flowmeter- 100 mm - OHR 1 Full Bore Electromagnetic Flowmeter: Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05 cu.m /Pulse) With LCD backlit Display, Calibration lab as per ISO 17025, Accuracy: 0.5%, +/- 2mm/sec, Measuring, Reference & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner,Supply: 24V DC or 230VAC
supply of DN 150 Electro-Magnetic Flow Meter with 20-Mtr Cable Make: As per PHE vendor list Full Bore Electromagnetic Flowmeter: Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05cu.m/Pulse) With LCD backlit Display, Calibration lab as per ISO 17025, Accuracy: 0.5%, +/-2mm/sec, Measuring, Reference & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner Supply: 24V DC or 230VAC OHR 4 & 8
supply of DN 200 Electro-Magnetic Flow Meter with 20 Mtr Cable Make: As per PHE vendor list Full Bore Electromagnetic Flowmeter-200 mm - OHR 2, 3, Adra GLR at Eastern railway, 5 and 6 Full Bore Electromagnetic Flowmeter: Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted), Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05cu.m /Pulse) With LCD backlit Display, Calibration lab as per ISO 17025, Accuracy: 0.5%, +/-2mm/sec, Measuring, Reference & Empty Pipe Detection Electrode with Polyurethane/Hard Rubber Liner,Supply: 24V DC or 230VAC
supply of DN 300 Electro-Magnetic Flow Meter with 10-Mtr Cable Make:As per PHE vendor list Full Bore Electromagnetic Flowmeter- 300 mm - OHR 7 Full Bore Electromagnetic Flowmeter: Protection: IP68 (Minimum inbuilt 20 meter cable, factory potted). Full bore type Electro Magnetic Flow meter With Smart Transmitter (Volume Flow rate output: 4-20mA HART Output and Totalizer Pulse Output: 0.05 cu.m/Pulse) With LCD backlit Display, Calibration lab as per ISO 17025, Accuracy: 0.5%, +/-2mm/sec, Measuring, per Reference & Empty Pipe Detection Electrode with Polyurethane/Hard Pubbortimen Rubber Liner ,Supply: 24V DC or 230VAC
supply of Insertion Type Magnetic Flow Meter (Probe Size:DN 700) Make:As per PHE vendor list Ultrasonic Clamp on Flow Meter 700 mm - WTP pump house. Didas Clamp common header Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater. Medium temperature: - 30-100 C 20 to +80 °C (-4 to +176 °F). Degree of protection IP68 (Type 6P onclecial for enclosure) for pipes under water. Shock and vibration resistance according to IEC 68-2-6, Aluminium field transmitter housing. 2-line display with push buttons. HART. 2 lines backlit display with 3 push button, EAC marking Measuring variable - Volume flow, sound velocity, flow velocity, signal strength, totalizer
Ultrasonic Clamp on Flow Meter - 500 mm - Intake pump house common header and filter house backwash common header Clamp-on flow measurement of process water, salt water, demineralized water, drinking & wastewater. Medium temperature: - 20 to +80 °C (-4 to +176 °F). Degree of protection IP68 (Type 6P enclosure) for pipes under water. Shock and vibration resistance according to IEC 68-2-6. Aluminium field transmitter housing. 2-line display with push buttons. HART, 2 lines backlit display with 3 push button, EAC marking Measuring variable - Volume flow, sound velocity, flow velocity, signal strength, totalizer Make -As per PHE vendor list
Radar Level Transmitter - CWR of WTP and intake Reliable measuring: for changing medias, pressure, temperatures, gas phases. Floodable sensor design: IP68/NEMA6P Approval: Non-hazardous area Power Supply; Output; Operation: 2-wire; 4-20mA; Bluetooth (App) configuration Antenna; Max. Measuring Range: 40mm/1-1/2"; 8m liquid -40...60°C/-40...1400F Process Connection Rear Side; Material: Thread G1 ISO228; PVDF Process Connection Front Side; Material: Thread ISO228 G1-1/2; PVDF Cable Length: 10m/32ft The instrument will be supplied with wired Meter Protection Box, consisting of Over Voltage Protection, 24V DC Power Supply and Surge Protection Make:As per PHE vendor list
Cloud Interface/RTU - 8 nos. OHR and WTP and Adra railway site Compact RTU complete with DI, DO, AI, Modem and modbus communication ports and power supply connection to control center via Tele Control Basic, IEC-60870-5-104 and communication protocols, on board I/O (8DI, 4D0, 4 AI), configuration and diagnostics per web interface, RJ45 port, mobile communication antenna (GSM), Mini SIM Card, TCP/IP, Open VPN Client. Panel Enclosure for compact RTU Location, wall/floor mounted along with wiring and related accessories and arrangement of mounting of RTU, Modem having IP-5X Protection. Pancl shall be self-fabricated type with canopy. Make: Phoenix/Sneider
Defixing the existing defective/idle unit then Installation above supplied items at different WTP and OHRS and GLRS site above mentioned, Erection & commissioning of above supplied items by using necessary tool tackles, tripod stand diesel generator, grinder, for dewatering purpose including hiring charge of expert plumber, helper, labour charge etc. considering all related works like cutting pipes, with supply and laying ci specials mechanical joint as required if required,collar, pipes etc. Including supply of all necessary materials, wire all electrical accessories nut bolts, gasket etc required for installation for fixing by all complete in all respect, as per direction and up to satisfaction of of EIC
Cloud based supervisory application - 1 Year Service. Development of Web architecture based SCADA software on Saas (Software as a Service) for a period of 1 year for10 nos. RTU. To be paid in advance for every 1 year. - Monitoring of plants by recording, processing and visualizing process and equipment data - Display additional device information such as device status or health information - Remotely verify Praline flowmeters with HeartbeatTechnology - Storage of all relevant data in long-term archives for evaluation in chronologicallists, curves or logs - Flexible aggregation of analog data into meaningful,condensed values - Formation of calculation values and key figures based on arithmetic, logical, exponential, trigonometric and historical calculations - Capture and process manual inputs such as lab and manual inputs - Flexible alerting on several signal paths based on standby plans extensive dashboard function for the clear and compressed presentation of plant data and characteristic values. A dashboard consists of freely editable tiles and can be easily created byplant users without programming knowledge. Visualization elements (speedometers,value displays, bar graphs, motors, etc.}, interactive curves, registration lists or free text input are available as elements. In addition, it is possible to integrate charts (line, column, bar,XY, area charts,continuous flow lines,carpetplot or multi-carpet plot). Connectivity For the monitoring of the systems and measuring devices the data can be connected with the help of connectivity components via various analog , digitaland fieldbus communication options . The connection to the web portal is protected by state-of-the-art security measures. Tdhe_following telecontrol tasks provided for dataintegration via edge device: Analogs and digital inputs such as 4...20rnA/HART/Pulse
The connection between the cloud service and the customer - site browser is certificate -based encrypted via TLS ( HTTPS) . - OPC UA incl. security features such as Sign & Encrypt - communication with other participants thus includes authentication and certificate-based encryption based on TLS (from the field level also possible with VPN) - MQTTS (TLS) encrypted communication to MQTT brokers (incl. authentication) for data integration of edge devices and field devices with cellular connection The system offers extensive possibilities for self-monitoring in order to ideally detect and prevent failures in advance. For this purpose, system characteristics are extensively recorded and monitored. Within the user interface, all input masks in the visualization or other interfaces are consistently validated. The system has rolebased user management. Rights are maintained group-wide and users are assigned to corresponding roles. A fine-grained assignment of rights is possible. The assignment of rights is designed to be fully multi-dient capable. The system effectively prevents unauthorized logins through extensive protection concepts. The system supports the following security-related login functions, among others: -The user is allowed to change his own password -The login mechanism complies with the Endress+Hauser password guidelines - Protection against brute force attacks (login by trial and error)
Supply and delivery of 1.1 KV grade XLPE insulated 35 sq,mm x 3.5 core Alumium Armoured cable as per IS: 7098 ( Part -1 )2011 Make: Gloster / Polycab/ Crystal /NICCO/Other approved make.
Laying of one No. cable upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Add GST @ 18%
Add CESS @ 1%
WEST BENGAL ENGINEERING CO.
M S ENTERPRISE
B T PROJECTS PRIVATE LIMITED
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .