| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹47.9 L+₹4.9 L (11.4%)Rejected-Finance MARYADA 111 SHIKARGARH KANHAIYA NAGAR JODHPUR 342001 | JODHPUR | RAJASTHAN | 342001 | L2 | Rejected-Finance Rejected being L2 |
Tender Value
₹50 L
EMD Value
₹1 L
Closing Date
19 Sept 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (ARMY) CENTRAL JODHPUR
GE ARMY CENTRAL MULTAN LINES ARMY AREA JODHPUR
PROVN OF DRAINAGE SYSTEM NEAR MAIN ENTRANCE GATE OF SATA REGT AND 01 NOS OVERHEAD SHELTER FOR IMS OF MECH INF BN AND OTHER CERTAIN SANCTIONED WORKS IN THE AREA OF AGE B R I UNDER GE ARMY CENTRAL JODHPUR
2022_MES_546565_1
GE/J/A OF 2022-23 (9129/E8)
Open Tender
Civil Works
Item Rate
180 days
JODHPUR
PROVN OF DRAINAGE SYSTEM NEAR MAIN ENTRANCE GATE OF SATA REGT AND 01 NOS OVERHEAD SHELTER FOR IMS OF MECH INF BN AND OTHER CERTAIN SANCTIONED WORKS IN THE AREA OF AGE B R I UNDER GE ARMY CENTRAL JODHPUR
8 documents required · 8 mandatory
₹500
GE (ARMY) CENTRAL JODHPUR
₹1 L
Yes
4 Oct 2022
22 Aug 2022
26 Sept 2022
22 Aug 2022
19 Sept 2022
5 Sept 2022
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation etc or for shaft, wells, cesspits, manholes, pier holes etc not exceeding 10 sqm on plan and getting out in any type of soil, complete all as specified and as directed .
M&L PCC 1:4:8 type D2 (using 40 mm graded crushed stone aggregate) as in foundation , filling and mass concerete complete all as specified and as directed.
M&L for squared rubble walling, Jodhpur type, regular coursed, well bonded ,bedded and solidly hearted built in cement mortar 1:6, complete all as specified and as directed.
Extra over square rubble stone walling, Jodhpur type, regular course for hammer dressing to face of stone with max depression on face from a straight edge not exc 20mm and dressing, complete all as specified and as directed.
M&L for rendering 10 mm thick in cement mortar 1:4 on stone masonry surfaces or concrete surfaces, finished surface fair & even with out using extra cement complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brickwork or on one side of lathing finished surface even and smooth with out using extra cement complete all as specified and as directed.
M&L for preparing new plastered or unplastered surfaces and applying two coats wall care putty including rubbing with sand paper to obtain a smooth surface and making good any undulations on the surfaces and applying two coats of oil bound distemper on walls, complete all as specified and as directed. Note:- OBD shall be in one or more colours/ shades all as approved by GE.
M&L for preparation of new plastered or un-plastered surfaces of wall and applying two coats of cement base paint of approved quality & tint, over & including one coat of chalk white, complete all as specified and as directed.
Use and waste formwork to side & soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick [horizontal or sloping] including rough finished surfaces complete all as specified and directed.
M & L RCC 1:1.5:3, nominal mix ( using 20 mm crushed stone graded aggregate as in beam, roof beam, cantilevers, lintel beam, etc., complete all as specified and as directed.
S & F mild steel TMT bar 10mm dia and over, cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam , slab etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
S & F mild steel TMT bar 5 dia and over upto and including 10 mm dia as in stirrups cut to length, bent to shape required including cranking, bending, spirally for hooping for columns, beam etc hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia or securing with clip complete all as specified and directed.
Returning filling in excavated soil, including spreading , leveling , watering and well ramming in layer n. exc 25 cm complete all as specified and as directed.
Removing excavated soil to a distance not exceeding 50 mtr and depositing where directed at a level not exc.1.50 mtr above the starting point, complete all as specified and as directed.
Removing excavated soil to a distance exceeding 500 mtr and not exceeding 1.0 KM and depositing where directed complete all as specified and as directed.
M&L sand filling under floor or in foundations including watering and consolidation complete all as specified and as directed.
M&L for 200 mm thick ready mix cement concrete (QCC) work in pavement/ hard-standing of flexural strength 40 kg/per square centimetre in field using 400 kg of cement per cubic metre, thickness of concrete 25 cm or less, complete all as specified and directed by Engineer-in-charge.
Excavating in post holes or similar holes each not exc 0.50 cu.m, getting out soft/loose soil, returning,fillig in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing srplus soil soil to a distance not exc. 50 m, complete all as specified and as directed.
Plain cement concrete 1:3:6 type C-2 by using 40 mm graded crushed stone aggregate as in foundation, filling and mass concrete, concrete block for iron strut or post complete all as specified and as directed .
M&L for steel work in tubular trusses including special shaped washers etc complete using ERW or induction butt welded tubes confirming to IS:1161-1979 Grade St-240, complete all as specified and as directed.
M&L for rolled mild steel sections like as roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. Fe-410- W(Gde- E-250) quality- A, complete all as specified and as directed.
M&L for rolled mild steel sections like as Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment Fe-410- W(Gde- E-250) quality- A, complete all as specified and as directed.
M&L for applying two coats of synthetic enamel paint on steel surfaces of any description over 10 cm width or girth, including & over a coat of red oxide primer including preparation of surfaces, complete all as specified and as directed.
Prepainted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws all as specified and as directed.
M&L for Aluminium framed doors/ partitions with shutters(Double/Single leaf) with one or more rebates,aluminium sections of approved make and weight not less than 0.55kg/m,including jointing cleat for fixing,handles,glazing/panelling boards etc complete all as specified and directed NOTE:Spring/door closer,glazing and panelling shall be measured and paid separately
M&L for Aluminium framed windows,any pattern,fixed/side hung/sliding (two or three track) using aluminium sections, of approved make and weight not less than 0.55kg/m,with or with out sash bars, suitable for 4 mm thick glazing, including necessary joining cleats,glazing clips,aluminium snap beading,rubber beading, handles,locking arrangement etc. all as specified and as directed. NOTE: Glazing shall be measured and paid seperately.
S&F for stainless steel wire cloth,0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples all as specified and as directed.
S&F anodised aluminium deco grill weighing not less than 1.40 kg/sqm and fixing necessary joining cleats complete all as specified and directed.
M&L 12mm thick, prelaminated particle board, medium density, water and termite proof, having both side decorative choice lamination , interior grade fixed with screws to wooden frame work as in kitchen cabinet / cup board including taking down old shutter complete all as specified and as directed.
S&F for door closer hydraulically regulated, designation No 3, aluminium (die cast ) body, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 Kg and fixed including taking down old one all as specified and as directed.
M&L 50mm thick PCC 1:3:6 type C-1 (using 20mm graded crushed stone aggregate) laid in alternative bays as in plinth protection including finishing the surface even & fair without using extra cement & filling the joints with mastic filling i.e one part of bitumen 85/25 and 3 parts of sand by weight, complete all as specified and directed.
Surface excavation not exceeding 30cm and averaging 15 cm deep and getting out in any type of soil complete all as specified and as directed.
M&L for 75 mm thick PCC 1:4:8 type D-2 (using 40mm gradded stone aggregate) as in sub base for flooring, complete all as specified and as directed by Engr-in-Charge.
M&L for 60 mm thick factory made chamfered edge cement concrete paver block of M-35 grade with 6 mm thick top layer of anti abrasive rubberised material, approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic prking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of fine sand, compacting and proper embedding/laying of interlocking paver blocks into the sand bedding layer throgh vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand.
M&L for factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required, complete all as specified and as directed by Engr-in-Charge.
Supply and fixing decorative type curtain rod stainless steel finish of pipe 22 to 25 mm dia with best quality knob metal as per sample kept in GE's office, , complete all as specified and as directed by Engr-in-Charge.
Supply and fixing in replacement purpose made brackets trade pattern for decorative type curtain rods suitable for holding 22 to 25 mm dia as per sample as in replacement kept in GE's office, complete all as specified and as directed by Engr-in-Charge.
S&F anodised aluminium snap grid frame work of size 605x605 mm for false ceiling, complete all as specified and as directed by Engr-in-Charge.
S&F hangers 6mm dia GI (upto 1200 mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of GI flat 40x3 mm size 60mm long, complete all as specified and as directed.
M&L for providing and fixing gypsum board 12 mm thick in ceiling fixed with screws as per manufacturers instructions, , complete all as specified and as directed by Engr-in-Charge.
M & L 20 to 25 mm thick machine cut Kota stone slab flooring as in cill etc over screed bed ,laid and jointed with grey cement slurry mixed with pigment to match with shade of slab including rubbing and polishing icluding 15 mm thick screed bed in cement mortor 1:6 complete all as specified and directed.
M&L PCC (1:2:4) type B-1 (using 20 mm graded crushed stone aggregate) as in benching/ channels of manholes/ drain etc including necessary form work complete all as specified and as directed .
Supply only integral water proofing compound. (ISI Marked)complete all as specified.
M&L for preparation of new plastered or unplastered surfaces and applying three coats of white wash on walls complete all as specified and as directed. .
M&L for rolled mild steel sections like angle, channel, flat, square etc as in framed work such as grills, gratings, etc, with ends of bars shouldered and/or riveted or forged into spikes, framed guard bars barred iron doors; chowkhat, doors with MS sheet, ladders ;framed balusters walk ways railings framed work of water tanks and similar work conforming to Fe-290Gde E-165 complete all as specified & directed by Engineer-in-charge
M&L for stone slab 25-35 mm thick dressed true and square, in one length not less than 60 cm and n.exc 120 cm in copings , window cills, chajjas, sunshades, drain cover etc punched dressed on exposed faces and self faced on the embedded unexposed beds and joints exposed edges rounded or chamfered as directed, set, jointed and pointed in cement mortar.
Demolition of cement concrete in ground floors and pavings not exc 15cm thickness (below or above ground level) and removing debris out of MOD land, complete all as specified and as directed by Engr-in-Charge.
Racking out joints/ pointing to to squared rubble masonry Jodhpur type, regular coursed, masonry built in cement mortar, coursed or un-coursed in walls not less than 12mm deep, washing the joints, removing rubbish off the premises and keeping the surface to pointed or plastered wet for two days prior to re-pointing or plastering complete all as specified & directed by Engineer-in-charge.
M&L for Keyed pointing to regular coursed, stone masonary or brought upto course with cement mortar 1:3, complete all as specified and as directed.
M&L for preparation of old plastered or un-plastered surfaces of wall by brooming down or steel wire brushing, scrapping down mass and efflorescent salts and trading oil & greasy spots, washing rubbing down and stopping surfaces and applying two coats of cement base paint of approved quality & tint, complete all as specified and as directed.
M&L for 25mm thick PCC 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate), as in sub base of flooring etc., incld finishing the surface even & rough to receive tile, complete all as specified and as directed.
M&L for Joint free non skid ceramic tiles (premium quality), coloured, of size exceeding 0.18 Sq.m and not exceeding 0.38 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including & over screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified and as directed. Make : Kajaria/ Somany/ Orient as approved by GE.
All as per item No. 54.00 here-in-above, but as in skirting over & including 10 mm thick backing coat with CM 1:4 Make : Kajaria/ Somany/ Orient as approved by GE.
M&L for Joint free non skid ceramic tiles (premium quality), coloured, of size exceeding 0.06 Sq.m and not exceeding 0.11 Sq.m, 7 to 8 mm thick [Square or Rectangular] as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of tiles including & over screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:6 complete all as specified and as directed. Make : Kajaria/ Somany/ Orient as approved by GE.
M&L for Joint free coloured glazed ceramic tiles (premium quality) of size 300mm x 450mm x 7mm / 350 x 250 x 7 mm thick on vertical surface of wall over and including 10mm thick backing coat in CM 1:4 set and jointed in neat cement slurry and pointed in white cement / coloured cement to match the tiles (Highlighter pattern) complete all as specified and as directed. Make : Kajaria/ Somany/ Orient as approved by GE.
Granite slab 18 to 20mm thick machine cut, factory polished, Jet Black & any colour as approved by GE, as in steps, jambs, pillars, window cills, cooking platform, and like bedded and jointed with grey cement slurry and pointed with white cement (1:2) with admixture of pigment to match the shade of granite stone over and including screed bed or bedding layer of mortar 20 mm thick in cement mortar 1:4 complete all as specified and directed.
Taking down cement plaster, any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc including removing rubbish to out side MD land complete all as specified and as directed.
Rendering 5mm thick in cement mortar 1:3 on concrete ceiling surfaces / facia / RCC chajja, finished even and smooth without using extra cement, complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling surfaces all as specified and directed by engr in charge.
Taking down chowkats or frames with shutters (without taking of shutters from the frames) area not exceeding 1.5 Sqm each complete all as specified and as directed.
Taking down chowkhats or frame with shutters (without taking of shutters from the frames) area exc 1.5 Sqm but not exceeding 4 Sqm each, complete all as directed.
S & F floor door stopper of size 150 mm of aluminium alloy body and tongue, anodised, with hard drawn steel spring complete all as specified and as directed.
S&F of stainless steel butt hinges 100mm size, include screws or bolts, nuts and washers to match the butt hinge, complete all as specified and as directed.
S&F aluminum anodised alloy handle extruded section of size 75mm long, complete all as specified and as directed.
S & F continuous [piano] hinges, mild steel, bright finish or electrogalvanised and width of Flaps 30mm [When Open] complete all as specified and as directed.
S & F Hasp and Staple, safety type of aluminium anodised including bolt to hinge plate, fixed with screws of 125mm size complete all as specified and as directed.
S & F mild steel, bright polished, size exceeding 25 mm dia but not exceeding 50 mm dia (as per sample) Cupboard Knobs fixed with nut, screw and washer complete all as specified and as directed.
S & F in replacement of stainless steel kitchen sink with drainage board, made of stainless steel 1 mm thick, with plugs, washers and waste pipe, including bedding in cement mortar to dwarf wall or including fixing cantilever brackets and connecting union to waste pipe, over all size 495 mm x 420 mm bowl size 410 mm x 330 mm x 160 mm complete all as specified and as directed. Make : Nirali/ Jayna/ Bluestar as approved by GE.
M&L for carrying out roof treatment work in the following stages :- (a) Applying a coat of bituminous primer @ 0.4 litre / Sqm manufactured by the same agency that of APP with a density 0.87 to 0.89 Kg/litre at 25 degree celsius on prepared plastered surfaces, over and including 10 mm thick cement mortoar (1:4) and surfaces finished even and smooth without using extra cement all as specified . (b) SECOND COURSE: Applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/Sqm (c) THIRD COURSE : Provide a layer of APP modified polymeric membrane centre core of 20 micron HMHDPE, outer film 20 micron each, thickness 1.50 mm having weight not less than 2.25 Kg/Sqm using torch application method with minimum 10cm side lap and 15cm end lap complete . (d) FOURTH COURSE : Applying one coat of bonding material using blown type bitumen confirming to IS- 702 grade 85/25 @ 1.20 Kg/Sqm. NOTE :- 1. A Information Tablet will be put up in the front side wall of the buildings where this work will be done. All building/structure shall be provided with plaque (tablet) furnishing the information as per PS clause, in plaster engraving in and painted as directed by GE 2.WPC shall be measured and paid separately under respective item. 3. Work of roof treatment shall be carried out by authorize applicator of APP manufracturer.
Supply only integral water proofing compound. (ISI Marked)
M&L for 18/19mm thick, prelaminated particle board, medium density, water and termite proof, having one side decorative choice lamination and other side balancing white lamination, , interior grade fixed with screws to wooden frame work as in kitchen cabinet / cup board including taking down old shutter complete all as specified and as directed.
S&F in replacement of vitreous ware wash down water closet [Pedestal Pattern], super special colours, [ETWC] including plastic water closet seat back closed pattern with flat bottom and cover and mild steel chromium plated or aluminium hinging device and 'P' or 'S' trap connecting to drain pipe and flushing pipe etc., complete all as specified and as directed. Make:-Cera Cat. No. S1053101 or equivalent model in Hindware / Parryware as approved by GE
S&F in replacement Vitreous China wash basin, (Ivory / Superior colors), Oval type (Under counter basin) size not less than 500x385x150mm size as per trade pattern, fixed to stone slabs, complete including CP waste coupling & flexible waste pipe and complete all as specified & directed by Engg.in-charge. Make:-Cera Cat. No. S2030104 or equivalent model in Hindware / Parryware as approved by GE
S&F in replacement of Pillar taps 15mm bore, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with long screwed shanks and fly-nuts, screwed for iron pipe, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar Cat No. ALI-85001 or its equivalent model in equivalent in Kohler/ Cera as approved by GE.
S&F in replacement stop valves, cast copper alloy with screw down high pressure with crutch or butter fly handle screw both ends for 25mm bore iron pipe or for union & fixed, complete all as specified and as directed. Make : Jaquar/ Kohler/ Cera as approved by GE.
S&F in replacement of chromium plated fancy type quarter turn angular stop cock with wall flange suitable for 15mm bore pipe, complete all as specified and as directed. Make : Jaquar Cat No. OPP-15053PM or or equivalent in Kohler/ Cera as approved by GE.
S&F in replacement of chromium plated fancy type quarter turn two way angular stop cock (Concealed Type) with wall flange suitable for 15mm bore pipe, complete all as specified and as directed. Make : Jaquar / Kohler/ Cera as approved by GE.
S&F in replacement of chromium plated fancy type quarter turn, angular stop cock (Concealed Type) with wall flange suitable for 15mm bore pipe, complete all as specified and as directed. Make : Jaquar / Kohler/ Cera as approved by GE.
S&F in replacement of bib cock with flange 15mm dia, chromium plated, cast copper alloy, fancy type, screwed for iron pipe or for brass ferrule, complete all as specified and as directed by Engr-in-Charge. Make : Jaquar cat No. ORP-10037PM or its equivalent model in Kohler/ Cera as approved by GE.
S&F in replacement of 9/10 ltrs capacity PVC valve less(Super special colors), (ISI Marked) syphonic action type, flushing cistern, low level, with Anti Bacterial Knob, with inlet, ball valve, float and handle including brackets, flush pipe of 32 mm dia and, cistern colour shall be match WC colour, complete all as specified and as directed. Make:- Cera cat. No. B1010102 CIENA PREMIUM or its equivalent model in Parryware / Jhonson as approved by GE
S&F in replacement of 500 ltrs capacity rotational moulded polythene water storage tanks white colour, three layered (ISI marked) (Cylinderically vertical with closed top) hoisted and fixed in postion all as specified in SSR Part-I including PTMT ball valve high pressure with epoxy coated aluminium rod and high density plastic ball suitable for 20mm bore pipe weight not less than 210gms, including dismantling of old UNSV PVC/RCC water tank & removing to store or outside MD land or credit to contractor, complete all as specified and as directed by Engg.-in-charge. Make:- Sintex / Rotex as approved by GE
Taking down or up GI steel tubing and connection including cleaning for refixing or removal to store, complete all as directed. (a) 25 mm bore
All as per Item No. 84.00 here-in-above, but size of 20 mm bore pipe
All as per Item No. 84.00 here-in-above, but size of 15 mm bore pipe
S&F GI water tubing medium grade, galvanized, with all fittings fixed to wall, ceilings or laid In floors, complete all as specified and as directed. (a) 25 mm bore
All as per Item No. 87.00 here-in-above, but size of 20 mm bore pipe
All as per Item No. 87.00 here-in-above, but size of 15 mm bore pipe including cutting chases, pinning in & making good to disturbed portion to match the existing surface etc., complete all as specified and as directed.
E/M ITEMS Taking down carefully aluminium/copper point wiring (light, fan, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, pendent, regulators, sockets, bell push, bell, light fittings etc. removing serviceable materials to store for keeping in safe custody for reuse at site or for taking credit (Credit shall be made as per Schedule of credit), removing rubbish from the site and making good all disturbed surfaces of walls, floors etc. to match to the existing surfaces, complete all as directed.
M&L point wiring using approved colour coding as per IS code -694 with valid CML No., with multi stranded copper conductor 1.5 sq mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLSH cable 1100 Volts grade, ISI marked, in and including heavy duty non metallic PVC rigid conduit of 25mm dia with accessories concealed in wall/roof/floor etc, ISI marked with1.6mm thick mild steel/ prestressed steel sunken / concealed box (with earth dolly) with 3 mm thick plastic laminated sheet (ISI Marked) cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated & unsheathed multistranded copper conductor 1.5 sq mm nominal cross sectional area single core FRLSH cable as earth continuity conductor to common earth and connecting to earth dolly suitable for One light/fan/bell point controlled by one, one way switch, complete all as specified and as directed.
All as per serial Item No.91.00 above but for one 3 pin socket outlet 5/6 Amps on the same board with other switches complete all as specified and as directed.
All as per serial Item No.91.00 above but for one 3 pin socket outlet 5/6 Amps on the independent board, complete all as specified and as directed.
All as per serial Item No.91.00 above but for 16 Amps 6 pin socket point on independent board with 2.50 Sqmm PVC insulated FRLSH multi-stranded copper conductor with 2.50 Sqmm PVC insulated & FRLSH multi-stranded copper conductor as earth wire complete all as specified and directed .
S&F switch piano, flush type, single pole, one way, 5/6 Amps, 230 Volts, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F switch piano, flush type, single pole, one way, 15/16 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F socket outlet, flush type, single pole, 3/5 Pin, 5/6 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F socket outlet, flush type, single pole, 3/5/6 Pin, 5/15 Amps, 230 Volts,ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F Electronic fan regulator, 120W, modular type, 2 module and connecting electrically, ISI Marked, complete all as specified and as directed by Engr-in-Charge. Make : Legrand/ ABB/ Schneider
M&L ceiling rose, 3 phase / PVC / Polycarbonate, isolated body, ISI Marked, complete all as specified and as directed. Make : Legrand/ ABB/ Schneider
S&F in replacement of LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose, including taking down old u/s material complete all as specified and as directed. Make : Bajaj Cat No. BCLSB 20 WH or Equivalent in Philips/ Havells as approved by GE.
S&F connecting, and commissioning of street light fitting 35 watt LED , IP-65 protection, single piece pressure dia cast aluminium alloy housing high immpact 4 mm thick heat resistant toughned clear glass cover for lamp and matrix of LEDs in built electronic driver upto 4 KV surge protection device and setting& input power 35 W system lumens 85/W operating voltage 160-260 V contror gear compartment with high voltage, Prewired including 1.20 mtr long 32mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified Make : Philips/ Bajaj/ Havells
S&F connecting, and commissioning of street light fitting 45 watt LED , IP-65 protection, single piece pressure dia cast aluminium alloy housing high immpact 4 mm thick heat resistant toughned clear glass cover for lamp and matrix of LEDs in built electronic driver upto 4 KV surge protection device and setting& input power 35 W system lumens 85/W operating voltage 160-260 V contror gear compartment with high voltage, Prewired including 1.20 mtr long 32mm bore light grade GI pipe mounting bracket made to shape with and including MS clamp of F1 40 mmx6mm with bolts , nuts & washers and conductor to fitting with 3 core 1.5 sqmm pvc insulated cable complete all as specified Make : Philips/ Bajaj/ Havells
Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete. Make : Philips/ Bajaj/ Havells
Fixing and hanging only ceiling fan/ Exhaust fan and connectiong up includisng provison of cable from ceiling rose or connector to fan.
S & F Air circulator fan 450mm sweep, 230 volts, AC Supply and connected with twin core twisted flexible copper conductor cable from ceiling rose to fitting complete all as specified and as directed.
S&F in replacement sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 6.00 Sqmm and one run of 6.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 6.00 sqmm cable with one run of 6.00 sqmm cable as earth wire and PVC conduit shall be measured & paid for as one length.
S&F in replacement of Prewired distribution board (sheet metal enclosures) SPN 8 way with suitable rated 200 Amps bus bar for Double door DB's of apporved gauge conforming to IS relevant, IP-43 protection, 240 volt, including taking down old u/s material, complete all as specified and directed by Engr-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface Make :-Legrand/ ABB / Schneider.
S&F in replacement sheet metal enclosures comprising 2 pin earth plug socket, with MCB SP 20 Amps (C-curve-10 KA) complete all as specified and as directed. Make :-Legrand/ ABB / Schneider.
S&F in replacement of Prewired distribution board (sheet metal enclosures) TPN 4 way with suitable rated 200 Amps bus bar for Double door DB's of apporved gauge conforming to IS relevant, IP-43 protection, 415 volt, including taking down old u/s material, complete all as specified and directed by Engr-in-charge. Note -Rate are deemed to be included for flashing in wall concealed complete, making good and matching existing surface Make :-Legrand/ ABB / Schneider.
S&F MCB single pole 240 volts rating from 5 to 30 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection, as in replacement, including taking down old u/s materialcomplete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F RCBOs, 2 Pole, 100mA, 40 Amps, for earth leakage, overload & short- circuit protection, (ISI marked), as in replacement, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB SPN 240 volts rating from 63 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection,as in replacement, including taking down old u/s material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
S&F MCB TPN 415 volts rating from 63 Amps, with rupturing capacity 10 KA, 'C' curve type, (ISI marked), with over load and short circuit protection,as in replacement, including taking down old UNSV material complete all as specified and as directed by Engg.-in-charge. Make : Legrand/ ABB/ Schneider
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC), complete all as specified and as directed. Make : Havells/ Bajaj/ CG
S&F exhaust fan, heavy duty steel body, AC single phase 300 mm sweep complete with louvers including fixing/grouting of frame & connecting with & including 3 core PVC insulated copper conductor flexible cable of size 23/0.0076 (or eq. Size in mm) from ceiling rose to fan, complete all as specified and as directed by Engg.-in-charge. Make : Havells/ Bajaj/ CG
M&L for earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron earth lead wire of size 4mm dia by means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 40 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion, complete all as specified and as directed by Engr-in-Charge. Note:- (i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead.
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor, stranded conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 Core 16 Sqmm nominal cross section in service connections, as in replacement, including taking down old u/s cable, complete all as specified and as directed.
S&F sub main wiring with two runs of PVC insulated but unsheathed multi stranded copper conductor FRLSH cable 1100 volt grade, as per IS code 694 with valid CML No. & ISI Marked, of size 6.00 Sqmm and one run of 6.00 Sqmm single core PVC insulated but unsheathed multi stranded copper conductor FRLSH cable (Phase-Red, Neutral-Black, Earth-Green) 1100 volt grade as earth lead drawn through in and including non metallic PVC conduit of size 25 mm dia (external) with wall thickness not less than 1.8 mm, (ISI marked) concealed in wall including accessories like bends, tees junction boxes, etc fixed in wall or ceiling etc., complete all as specified and as directed by Engr-in-Charge. NOTE: Two runs of 6.00 sqmm cable with one run of 6.00 sqmm cable as earth wire and PVC conduit shall be measured & paid for as one length.
GI tubing , light grade of 50mm bore with fittings as in road crossings for cable protection complete all as specified and as directed.
S&F ON-LOAD change over switch 63 Amps 4 pole 415 Volts with sheet metal encloser complete all as specified and as directed . Make : Legrand/ ABB/ Schneider
Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor, stranded conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 4 Core 25 Sqmm nominal cross section in service connections, as in replacement, including taking down old u/s cable, complete all as specified and as directed.
Supply, installation, testing and commissioning in existing location and position refrigerator, digital panel, electric driven, single phase having approx storae and nominal cooling capacity 310 ltrs, frost free inverter, AG clean technology, using eco friendly gas , minimum BEE 5 star rated and above complete with all acessories as per manufacturer. Make : -Bluestar/ Bosch/ Voltas
Supply, installation and testing in existing location and position, metal top deep freezer, chest freezer, double door, size 1145mm x 735mm x 900mm, 100 % copper cooling coil & corrosion resistant PPGI for indoorand outer body, single phase voltage 190-254V, upto 10 Hrs backup/ Hold after power cut, 10 years Guarantee on body & 5 years on compressor, CFC free insulation, sunken handle, electric driven, single phase, having approx storage and nominal cooling capacity 350 ltrs, BEE Star Rating - 3 Star and above rated, complete all as specified and as directed. Make :- Bluestar/ Bosch/ Voltas.
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA, complete all as specified and as directed. Make:- Microtek/Volina
Supply, fixing, testing and commissioning electric storage geyser of capacity 25 Ltrs, 230Volts, AC, 50Hz, comprising of heating element 2000 watt,puff insulation,both power indicating LED lamp and heating indicating LED lamp neccasry suitable 3 core copper cable,suitable plug top, inlcluding supply and fixing of inlet and out let connection to geyser with steel grip,chromium plated PVC braided hose with connecting legs, connection of 600mm in length - 02 Nos (one for inlet GI pipe and other one for outlet connection) suitable to connect inlet GI pipe 15mm dia and out let GI pipe 15mm dia (out let PVC connection should be capable to withstand the designed temparature of Geyser) and geyser shall be fixed on wall surface with wall mount bracket and 10 cm anchor bolts as required inclduing all necessary plumbling works and civil works complete all as directed and as specified. Make :- Jaguar/ Bluestar / Havells
NOTE:- (i)- Quantities are clubbed in BOQ for different Jobs. For which ref. Annexure-I on Sl. page. No. 41 to 43 of tender document. (ii)- The contract sum shall be arrived at after duducting amount of schedule of "Credit" from the Total quoted amount
M/S KAUTILYA GARG
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .