Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Rejected-Technical | Rejected-Technical Technically Disqualified |
| 3 | Not Admitted-Fee/PreQual/Technical | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
| 4 | Rejected-Technical | Rejected-Technical Technically Disqualified |
Tender Value
₹4.8 L
Closing Date
17 Dec 2021, 2:30 pmClosed
GM HWPK
GM office HWPK Anushakti
CHEMICAL CLEANING OF COOLING WATER HEAT EXCHANGERS AND CHILLED WATER HEAT EXCHANGERS IN XU at HWPK site
2021_HWB_661250_1
HWPK/PROD/2021/502
Open Tender
Job Works
Works
45 days
HWPK Anushakti
As per NIT
8 documents required · 8 mandatory
₹0
Exempted
21 Mar 2022
6 Dec 2021
18 Dec 2021
6 Dec 2021
17 Dec 2021
11 Dec 2021
Amount
Chemical cleaning to be carried for loop 1 i.e. 3101 CWX-1 & 2 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 2 i.e. 3101 CWX-4 &5 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 3 i.e. 3101 CWX-7 & 8 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 4 i.e. 3201 CWX-1 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 5 i.e. 3201 CWX-2 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 6 i.e. 3301 CWX-1 &2 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 7 i.e. 3911 CWX-1 - 10 & 3921 CWX 1 to 10 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 8 i.e.3101 CHX-1 & 2 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 9 i.e. 3101 CHX-4 &5 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 10 i.e. 3201 CHX-1 &2 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 11 i.e. 3201 CHX-4 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 12 i.e. 3401 CHX1 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 13 i.e. 3401 EX1 (Converted to CHX) as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 14 i.e. 3301 CHX1 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 15 i.e. 3301 CHX-2 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
Chemical cleaning to be carried for loop 16 i.e.3301 CHX4 as 1) closed loop is to be made(Pump, piping, gaskets, Tanks etc will be provided by the Department), 2) Water flushing of exchangers. 3) Sulphamic descalant solution preparation. 4) Sulphamic acid descaling. 5)Neutralization and safe disposal of effluent. 6) Reflushing of exchanger. 7) Neutralization and passivation of exchanger.
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .