Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹16.8 L+₹83,382 (5.22%)Rejected-Finance | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹16.9 L+₹90,045 (5.64%)Rejected-Finance | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹18.9 L+₹3.0 L (18.6%)Rejected-Finance | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹19.1 L+₹3.1 L (19.4%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
Tender Value
₹18.8 L
EMD Value
₹37,600
Closing Date
30 May 2020, 6:00 pmClosed
CWE, HQ 133 WKS ENGRS
HQ 133 WKS ENGRS PIN 914133 C/O 56 APO
SPECIAL REPAIRS TO BUILDING NO. P-32 (MULE LINE) AT BARAMULLA UNDER GE 969 EWS
2020_MES_340032_1
CWEK-03/2020-21
Open Tender
Support/Maintenance Service
Item Rate
270 days
GE 969 EWS
Class E Category a (i)
7 documents required · 7 mandatory
₹500
Yes
GE 969 EWS
₹37,600
Yes
HQ 133 WKS ENGRS
11 Jun 2020
21 Apr 2020
1 Jun 2020
21 Apr 2020
30 May 2020
5 May 2020
21 Apr 2020 - 1 May 2020
1 May 2020
Amount
SCHEDULE A PART I (B/R WORKS)
Excavation in post hole or similar holes in soft/loose soil each not exceeding 0.50 Cum including getting out, returning, filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25cm thick, watering and removing surplus soil to distance not exceeding 50metre and making good surface, complete all as specified and directed.
Excavating in trenches, not exceeding 1.50 metre wide and not exceeding 1.50m in depth for foundation etc. or for shafts, wells, cesspits, manholes, pier holes etc. not exceeding 10 sq.m on plan and not exceeding 1.50m in depth and getting out in soft/loose soil, complete all as specified and as directed .
Returning filling in including spreding leveling watering and well ramming in layers not exc 25 cm each in soft/loose soil, complete all as specified and as directed .
Removing excavated materials to a distance not exc 50 m and depositing where directed at level n exc 1.5 above the starting points, complete all as specified and as directed .
Material and labour for broken stone hard core of gauge n.exc 63mm, deposited, spread and leveled in layers n.exc 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
Dismantling wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/slabs any thickness, including cover fillets complete all as specified.
Dismantling plain or corrugated mild steel sheeting any gauge, thickness, including Nanital or similar pattern roof covering, complete all as specified.
Supply and fixing for 0.63mm Galvanised, Corrugated Mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers, ISI marked,, in roofs, walls etc. with grade of zink coating 275, complete all as specified.
Fixing only galvanised, corrugated mild steel, sheeting with two corrugation side lap fixed with L type or J type or cranked hook bolt and bent to curve (of any radius) as in roof covering complete all as specified and as directed Note :-Sheets obtained from dismantling from item No. 1.07 shall be reused.
Supply and fixing 0.80 mm thick Plain, galvanized mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) of class-2, ISI Marked, complete all as specified.
Demolition of Stone sett paving, flooring laid, bedded and pointed in any mortar of any description or thickness, complete all as specified and as directed.
Material and Labour for stone sett flooring with stone setts of size 600 to 1200 mm long, 150 to 300mm wide and 75mm deep and sides dressed; bedded in cement mortar 1:3, 20mm thick; joints grouted in cement mortar 1:2 with an admixture of metallic floor hardner, 5% by weight of cement and struck flush complete all as specified and as directed.
All as per ser item No. 1.12 here-in-above, but except stone setts, complete all as specified and as directed. Note- The serviceable stone setts obtained from Serial item No 1.11 shall be reused after removing motar, cleaning with water, etc.complete.
Dismantling timber scantlings in any position in fillets, rails, posts, rafters , purlins, etc. under 40 sq. cm in section (framed / unframed work) complete all as specified and as directed.
Dismantling timber scantling 40 Sq. cm and over in section, in any position of unframed/ framed work complete, all as specified and as directed .
Dismantling of wrought iron or mild steel work of any description not otherwise specially provided complete all as specified.
Dismantling of brick work or stone masonary, precast cement concrete walling built in cement mortar including all quoins, arches, pillars etc., complete all as specified and as directed.
Material and labour for brick work with subclass ‘B` old size bricks, straight or curved on plan exceeding 6 metre mean radius built in cement mortar (1:6), complete all as specified and as directed.
Material and Labour for Brick work with sub class ‘B’ bricks (Except Bricks), straight or curved on plan exceeding 6 metre mean radius, built in cement mortar (1:6) , complete all as specified. ( Note- The serviceable bricks obtained from Serial item No- 1.17 will be used after removing motar, cleaning the bricks with water, etc.)
Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 complete all as specified and as directed.
Material and labour for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4 but except stone complete all as specified and as directed. Note- The serviceable stones obtained from Serial item No-1.17 will be used after removing motar, cleaning with water, etc.)
Demolition of cement concrete (unreinforced) in ground floor and pavings not exceeding 15cm thickness (below or above ground level) and removal the rubbish/ demolished material outside defence land, complete all as specified and as directed.
Material and labour for hammer dressing to granite or trap stone with maximum depression from a straight edge held against the surface not exceeding 40mm dressing, complete all as specified and as directed .
Material and labour for plain cement concrete 1:2:4 type B-1 (using 20mm graded mechanically crushed stone aggregate) as in surface channels and drains, complete all as specified and as directed.
Material and labour for plain cement concrete, 1:2:4 type B-1 (using 20 mm graded mechanical crushed aggregate) for levelling course, benching, coving, coping, etc. complete all as specified and as directed.
Material and Labour extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds , mitred /stopped ends etc., complete all as specified and as directed.
Supply and fixing 2nd class hard wood fillets, clean swan, bull nosed, chamfered or rounded on one face, sectional area exceeding 3 Sq. cm but not exceeding 6 Sq. cm, fixed with nails or brads including two coat of painting over a coat of pink primer after preparation of new fillets surface, complete all as specified.
Material and labour for Second class hardwood (Hollack) plain fillets, square, rectangular or triangular in section of area exceeding 6 Sq. cm and not exceeding 13 Sq. cm, clean sawn, secured with nails or brads, complete all as specified and as directed.
Supply and fixing IInd class (hollock) factory made 35mm thick glazed skelton shutters, open rebated and prepared to receive glass, gauge etc. divided into squares edges of framing, plain, chamfered or rounded, mitred fitted with cut and mitred beads for securing glass/gauge etc. with sizes of members of shutters as specified in para 8.24(a) of SSR 2009 (Part I), complete all as specified and as directed.
Supplying and Fixing for factory made 35mm thick, 2nd class HW, plain framed, panelled shutters (two panel) with lock rail and panel of 9mm B.W.P. commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS:1003 (Part I), kiln seasoned and chemically pressure treated, complete, all as specified and as directed.
Taking down chowkats or frames with shutter area not exceeding 1.50 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish complete, all as specified and as directed.
Taking down chowkats or frames with shutter area exceeding 1.50 Square metre and not exceeding 4.00 Square metre (w/o taking off shutters from frames) and removing from site, including cutting holes for taking out existing hold fasts and making good the disturbed portion of jambs and adjoining surfaces to match with existing finish , complete all as specified and as directed.
Supply and fixing for 2nd class hard wood plain, solid straight chowkats and frames, wrought framed rebated on the solid, rounded or chamfered put together with glue pinned at joints, complete all as specified and as directed .
Supply and fixing framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc., n exc 10 kg each brackets, conforming to Fe 410-W. Gde-E-250 complete all as specified and as directed.
Material and labour for mild steel work of flat iron as in wind tie including necessary holes, etc grade Fe-410-S complete all as specified and as directed.
Supply and fixing for rolled mild steel in compound girders and stanchions, lattice girders, aerial masts, staging for water tanks and the like including caps, bases, splices etc. built up from two or more beam or channel sections or angles with plates, including all lattice bars, stiffeners, gusset plates, etc., quality confirming to Fe-410(Gde E250), complete all as specified and as directed.
Supply and fixing aluminum anodized, barrel tower bolt of extruded section 125mm long, ISI marked, complete all as specified and as directed.
Supply and fixing 300 mm aluminum anodised sliding door bolt, ISI marked, with hasp, staple (bolt type) complete with clamps bolt not less than 16mm dia and fixing clips of sheet, cast or extruded section and fixing bolts an sliding bolt of extruded section or cast aluminum alloy, complete all as specified and as directed.
Supply and fixing for butt hinge ,ISI Marked ,100mm size, medium weight, cold rolled mild steel complete, all as specified and as directed.
Supply and fixing for butt hinge ,ISI Marked ,75mm size, medium weight, cold rolled mild steel complete, all as specified and as directed.
Supply and fixing for ISI Marked 150 mm long, aluminium handle, cast type, anodized, complete, all as specified and as directed.
Supply and fixing for ISI Marked 100 mm long, aluminium handle, cast type, anodized, complete, all as specified and as directed.
Material and labour for PCC 1:3:6 type C-1 (using 20 mm graded mechanically crushed stone aggregate), 50mm thick, as in plinth protection/PCC path and paving, laid in panels of area not exceeding 2.00 sqm with 6mm wide joints filled with mastic (using bitumen and sand mixture applied hot in the ratio of 1:3 by weight) formed at the end of each panel and change in direction of plinth protection/PCC Path and paving and finishing the top surface even and smooth without using extra cement complete all as specified and as directed.
Material and labour for 40mm thick PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in floor,finished even and smooth with out using extra cement complete all as specified and directed .
Material and labour for Glass dividing strips, 3mm thick and 38mm in width inserted in position conform to design complete all as specified and directed .
Material and labour for 25mm thick PCC 1:2:4 type B-0 using 12.5mm graded stone aggregate as levelling course, finished even and fair to receive floor finishes, complete all as specified and directed.
Material and labour for 75mm thick PCC 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in sub base to floor, complete all as specified and as directed
Material and labour for 100mm thick PCC 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate) as in sub base to floor, complete all as specified and as directed.
Material and labour for premium quality, glazed coloured ceramic tiles 300 x 450 x 7mm thick on vertical surfaces of walls including 10mm thick rough finished plaster in cement mortar (1:3) set jointed in neat cement slurry and pointed in coloured cement to match complete, all as specified and as directed.
Material and Labour for vibratory compacted, precast cement concrete, coloured (other than grey), rubber moulded , interlocking designer paver blocks( double glossy) in any and shape, confirming to IS-15658-2006 of 80mm thickness, M-40 grade in path, hard standing, etc. laid over and including 25 mm thick bedding layer of sand complete, all as specified and as directed.
Material and labour for plain cement concrete 1:3:6 type C-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed.
Material and labour for plain cement concrete 1:4:8 type D-2 (using 40 mm graded mechanically crushed stone aggregate), as in foundation filling and mass concrete, complete all as specified and directed.
Taking down cement plaster of any description, thickness and in any position including raking out joints, hacking for key, scrubbing down with water etc , and removal the rubbish/ demolished material outside defence land, complete all as specified and as directed.
Material and labour for 10mm thick rendering in cement mortar (1:6) on surface of any description of brick or concrete and finished the surface even and smooth without using extra cement complete all as specified and as directed.
Material and Labour for 15mm thick rendering (in patches) in two layers on fair faces of brick work or concrete surfaces in cement mortar 1:4 mixed with WPC @2% by weight of cement or as per manufacturer’s instructions, finished even and fair, complete all as specified and as directed. (Note : WPC shall be measured and paid separately)
Supply only integral water proofing compound, complete all as specified and as directed.
Material and Labour for keyed pointing to random or polygonal rubble uncoursed or brought upto courses in concrete mortar 1.4 complete all as specified and as directed.
Material and labour for 2nd class hardwood clean sawn in scantlings, in any position in framed work, complete all as specified and directed
Description all as per serial item No.1.58 above but except timber, complete all as specified and directed
Material and labour for preparation of new plastered surfaces and applying three coats of white wash on wall, complete all as specified and as directed.
Material and labour for three coat of white wash on newly plastered surface of ceiling including preparation of ceiling surfaces complete all as specified and as directed.
Material and labour for two coat of cement base paint over a coat of alkaline resistant primer on newly plastered surface including preparation of surface of wall complete all as specified and as directed.
Material and labour for preparing new or previously untreated wood and wood based surfaces of any description not otherwise described over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer complete all as specified and as directed.
Preparation of old painted steel surfaces of any description over 10cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and as directed.
Material and labour for two coats of synthetic enamel paint on steel surfaces over a coat of red oxide primer including preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth, complete all as specified and as directed.
Supply and fixing in repair, water storage tank 1000 ltr capacity HDPE triple layer, white coloured, conforming to IS , fixed and hoisted in position on staging or roof complete with locking arrangement including over flow pipe, air lock pipe, brass valve 20 mm high pressure with polythene float and flynut, screwed and suitable for iron pipe 20 mm bore,including taking down the unserviceable water tank and removing from site, complete all as specified and as directed.
Taking up or down steel tubing and connections for 20mm dia including cleaning for refixing or removal to store complete all as specified and as directed.
Material and labour for 25mm Bore 3 layers PP-R polypropylene random copolymer) pipes SDR 7.4 and SDR 11 UV stablised and antimicrobial welded having thermal stability for hot and cold water supply including all PP-R plain and brass threaded polypropylene random fittings fixed complete to walls, ceiling or in floors etc.complete all as specified and as directed.
Fixing only in repairs 25mm Bore 3 layers PP-R polypropylene pipes, any grade, to walls and ceilings or laying in floors with new fittings. complete all as specified and as directed. Note: Old pipe reteived from serial item No. 1.67 hereinbefore shall be reused in this item.
Supply and fixing in repair 25mm PP-R Brass Valves (brass insert) and high density plastic ball screwed for iron pipe, complete all as specified and as directed.
Supply and fixing in repair, 25mm PP-R Gate Valves (brass insert) as per requirement of the site screwed for iron pipe, complete all as specified and as directed.
Material and labour for lagging to 25mm dia pipes used in internal water supply or plumbing all round with 25mm thick bonded mineral wool pre-formed `SNAP ON` pipe sections of density 144 Kg/cum conforming to IS 9842 complete all as specified and as directed.
Supply and fixing 6mm thick Asbestos cement plain building boards in ceiling fixed to timber frame work with screws complete all as specified and directed
Supply and fixing for sheet glass 4mm thick, ordinary quality , in square not exceeding 0.5 sqm in each pane and glazing with oil putty to steel window and with wooden beads to wooden shutters, complete all as specified and as directed.
SCHEDULE A PART II (INTERNAL ELECTRIFICATION)
Taking down carefully any type point wiring (light, fan, socket or power) complete with fittings such as switches ceiling roses, pendants, regulators, sockets tube light fitting with all accessories etc. removal of materials from site and making good the disturbed surfaces of wall, floors, ceiling etc to match with the existing surfaces complete, all as specified and as directed.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke (FRLS), 1100 volt grade with multi stranded copper conductor drawn through and including medium grade , ISI marked PVC casing caping not less than 32 mm width , 10 mm depth with accessories, on wall/ceiling surface and including provision of 1.50 Sqmm single core PVC insulated , unsheathed cable flame retardant low smoke (FRLS), 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including GI sunken boxes 1.2mm thick of any module from 2 module upto 18 module GI sunken boxes conforming to IS-5139(part-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including modular cover plates with frame i.e. inner and outer plate for sunken box for housing the modular switches , socket outlets, fan regulators etc. with brass screws and brass washers and making good the disturbed surfaces as per existing for one light/fan point controlled by one switch. Note :- Switch, socket and fan regulators to be measured and paid for separately .
Description all as per Srl item No.2.02 here in before but for socket outlet point 5 Amp on same board.
Description all as per Srl item No.2.02 here in before but for socket outlet point 5 Amp on Independent board complete, all as specified and as directed.
All as per the description of Serial Item No 2.02 above, but with 2.50 Sq mm un-sheathed multistranded cable for one socket outlet 15 Amps independent including continuous copper earth wire, PVC insulated of 2.50 Sq mm size complete, all as specified and as directed . (Switch, Socket shall be measured and paid separately)
Supply and fixing switch piano 5/6 Amps, flush button type, single pole, one way, 240 volt , AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing socket outlet 5 pin 5/6 amps, 240 volt. flush type, AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing switch socket combination, 5 Amp, 2 in 1, single pole one way ,230 volts, flush type, AC supply, ISI Marked, complete all as specified and as directed.
Supply and fixing switch socket combination, 5/16 Amp, 5 in 1, single pole one way ,230 volts, flush type, AC supply, ISI Marked, complete all as specified and as directed.
Supplying and fixing the ceiling rose, three terminal ISI marked surface backlit, complete all as specified and as directed.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, ISI Marked, complete all as specified and as directed.
Supplying only pin type LED bulb, 15 watt pin type, ISI marked, suitable for batten holder complete, all as specified and directed. Make: Havells Cat Part No. LHLDEREEMK8X015 or equivalent model in makes mentioned for Group 2 in Appendix 'B' of tender document .
Supplying and fixing in replacement, LED bulk head light fitting 1x10 watt with lamp holder(1x10W) ABS housing, IP65 and connecting up with twin core twisted flexible copper conductor cable of suitable size from ceiling rose to connector of light complete, all as specified and directed. Make: Bajaj Cat Part No. BIBWP 10WLED or equivalent model in makes mentioned for Group 2 in Appendix 'B' of tender document .
Supply and fixing in replacement indoor decorative 20 watt LED tube light luminarie, extruded aluminium housing with polycarbonate diffuser and integrated electronic driver , AC 220-240 Volts, 50Hz including lamp ( Lamp type LED tube light 1x 20 Watt) and connecting up with three core 1.5 sqmm flexible copper conductor cable from ceiling rose to connector of light complete, all as specified and as directed. Make: Havells Cat Part No. ENDURALINEARNEOBS20WLED865SPCWH or equivalent model in makes mentioned for Group 2 in Appendix 'B' of tender document .
Supply and fixing exhaust fan 380mm size , ISI marked, AC single phase 230/240 volt ,steel body with louver, 1400 RPM and connecting with twin twisted copper conductor flexible of size 0.50 sqmm including cutting of existing wall and making opening in the existing wall for fixing exhaust fan, fixing nut bolts necessary for fixing exhaust fan and making good the disturbed surfaces and testing complete, all as specified and directed.
Supply and fixing MCB single pole, 240 volts, 50Hz , breaking capacity 10KA, B curve, 6 to 32 Amps, ISI marked, complete all as specified and as directed.
Supply and fixing MCB single pole and neutral, 240 volts, 50Hz , breaking capacity 10KA, B curve, 6 to 32 Amps, ISI marked, complete all as specified and as directed.
Supply and fixing MCB Double pole, 415 volts, 50Hz , breaking capacity 10KA, C curve, 40 Amps, ISI marked, complete all as specified and as directed.
Supply , insatallation, testing of SPN distibution board 08 way,double door , IP 43 , as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles, concealed on the wall surface including taking down the existing DB's any type and description and making good the disturbed portion with adjoining surfaces to match with existing finish, complete, all as specified and as directed.
Supply , insatallation, testing of SPN distibution board 12 way,double door , IP 43 , as per IS 8623 including 200 amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing, reversible doors, PAN assembly for easy installation and also incoming and outgoing connections with suitable size of lugs/thimbles, concealed on the wall surface including taking down the existing DB's any type and description and making good the disturbed portion with adjoining surfaces to match with existing finish, complete, all as specified and as directed,
Taking out old earthing complete and taking out old unserviceable earthing material and provision of new earthing complete with galvanised earth plate electrode 600mm x 600mmx 6mm thick surrounded by charcoal and salt, buried directly in ground vertically in a pit of depth not less than 2.25m below ground level with top edge of the earth plate not less than 1.5m below normal ground level, connected to 4.00 mm wire earth lead by means of bolts, nuts, checks nut and washers made out of galvanized iron or steel, earth wire protected by galvanized steel pipe 15mm dia (light grade) and connected to main switch or main control board all as shown in electrical plate No.3 of SSR Part-I & including necessary excavation and earth work. The rate also include charcoal & salt in alternate layers, 20mm dia GI pipe (light grade) for watering, protection pipe, funnel, wire mesh, RCC cover etc. complete, all as specified or indicated including testing on completion. Note : The rates for earth work in any type of soil, returning filling and removal, GI protection pipe, funnel, wire wesh, RCC cover, etc shall be deemed to be including in quoted rates. RCC cover shall be 50mm thick in 1:2:4 type B-1 using 8mm bars @10cm c/c both way.
Material and labour for sub main wiring with two single core flame retardant low smoke (FRLS) , PVC insulated unsheathed copper conductor cable 6.00 sqmm drawn through and including medium grade , ISI marked PVC casing caping not less than 32 mm width , 10 mm depth with accessories fixed on wall/ceiling surface with one additional PVC insulated , stranded copper conductor flame retardant low smoke (FRLS) of 6.0 sqmm,green colour for earth continuity conductor including taking down old unserviceable sub main wiring complete, all as specified and directed. Note- 3 run of 6.00 sqmm cable with casing caping shall be measured as 1 unit.
Supply and laying and testing XLPE insulated , screened, PVC bedded, galvanised steel strip or wire armoured electric power cable 1100 Volts grade with stranded aluminium conductor of size 16 Sq mm 2 core, complete, all as specified and as directed.
Material and Labour for Fine and dry sand cushioning for underground cable by providing a layers of sand 8cm deep before laying and 15cm deep after laying the cable including tretching the cable, complete all as specified and as directed. Note - Punned thickness of sand layer shall be measured and paid to contractor.
Material and labour for sub class brick laid dry width wise across the cable in trenches for protection of cable complete all as specified.
Supply, installing, testing and commissioning of single phase portable water mixture crowdent double head air-compressor of capacity 0.75 HP including necessary electric connection, PCC founation and other accessories complete all as specified and directed complete as in repair.
Note:- Amount of credit of Rs. 37355.00 for retrieved materials as mentioned in Schedule of Credit Page No 34 of tender documents in pdf form which will be deducted offline while acceptance of tender.
m/s mohd rafiq lone
M/S MUKHTAR CONSTRUCTION CO
M/S GHULAM RASOOL LONE AND SONS
M/S GHULAM NABI LONE AND BROS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .