| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.3 LAccepted-AOC UPPER SARTHI VIHAR AJABPUR KALAN PO NEHRUGRAM HARIDWAR ROAD DEHRADUN 248001 UK | DEHRADUN | UTTARAKHAND | 248001 | ₹6.3 L Quoted ₹6.7 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹8.8 L+₹2.1 L (30.5%)Rejected-AOC GANDHI CHOWK LANSDOWNE 246155 | PAURI GARHWAL | UTTARAKHAND | 246155 | ₹8.8 L+₹2.1 L (30.5%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹9.3 L+₹2.6 L (38.5%)Rejected-AOC | ₹9.3 L+₹2.6 L (38.5%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹10.2 L+₹3.5 L (51.9%)Rejected-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | ₹10.2 L+₹3.5 L (51.9%) | L4 | Rejected-AOC Not Lowest |
| 5 | L5₹10.8 L+₹4.1 L (60.9%)Rejected-AOC 2523 B LANE NO 3 TURNER ROAD DEHRADUN 248002 | DEHRADUN | UTTARAKHAND | 248002 | ₹10.8 L+₹4.1 L (60.9%) | L5 | Rejected-AOC Not Lowest |
Tender Value
₹13.5 L
EMD Value
₹27,000
Closing Date
17 Dec 2022, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE HILLS DEHRADUN, MAll Road, Dehradun Cantt- 248003
REPAIR AND MAINT OF INTERNAL WIRING SUB MAIN WIRING CEILING FANS EXHAUST FAN FITTINGS AND FIXTURES AT VARIOUS LOCATIONS OF KOTDWARA UNDER AGE I LANSDOWNE
2022_MES_562422_1
87150/LDN/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
AGE I Lansdowne
Class E Cetagory b i
7 documents required · 7 mandatory
₹500
AGE I Lansdowne
₹27,000
Yes
9 Jan 2023
10 Nov 2022
24 Dec 2022
10 Nov 2022
17 Dec 2022
5 Dec 2022
Amount
Dismantling and taking down U/S point wiring of any type (light, fan, socket, power) complete fitting such as switches, ceiling roses, pendants, lamp holder, light fitting etc including CI/Pressed steel terminals, switch box, and making good the disturbed surface of wall/floor etc, to match with the existing surfaces of wall/floor complete all as specified and directed. Note :- If the contractor fail to make good the disturbed surface of wall/floor etc and do not match with the existing surface of wall/floor to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Taking down carefully by unscrewing ceiling roses, Light fittings, switch , sockets, regulators for reuse at site and carrying to the store to re-fix the serviceable materials complete all as specified & directed. Note :-To be measured only when found serviceable in all respect for reuse.
Dismantling and taking down u/s sub-main wiring of any size including wooden batten / PVC Conduit etc and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ceiling etc complete all as specified & as directed. Note :- If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Dismantling and taking down old damaged existing TPN DB/DB’s of any type and making good the disturbed surfaces of wall/ceiling to match with the existing wall/ ceiling etc complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including concealed PVC conduit, "medium grade" (ISI marked) , not less than 20 mm dia duly concealed on wall/ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed. Note:- (i) Cost of cutting chases of suitable girth where required on brick / concrete surface and making good disturbed surface shall deemed to be included in quoted rates. (ii) If the contractor fail to make good the disturbed surface of wall/ceiling etc and do not match with the existing surface of wall/ceiling to the entire satisfaction of Engr-in-Charge a recovery @ of Rs. 50/- per RM will be made from payment due to the Contractor. In case of any dispute the decision of accepting officer will be final and binding.
Description same all as per serial Item No 5.0 here in before but One 3 pin/5 pin 5/6 Amps socket outlet on same board with other switches, with cables 1.5 Sqmm size, complete all as specified and directed.
Description same all as per serial Item No 5.0 here in before but for One 3pin/5pin 5/6 Amps socket out let on independent board with other switches, with cables 1.5 sq mm size, complete all as specified and directed.
Description same all as per serial Item No 5.0 here in before but controlled by two, two way switch 5/6 Amps. With cables 1.5 sq mm size complete all as specified & directed.
Description same all as per serial Item No 5.0 here in before but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
Description same all as per serial Item No 5.0 here in before but in existing concealed conduit inside wall, ceiling etc (light, fan, call bell) complete all as specified and directed.
Description same all as per Item No 5.0 here in before but in existing concealed conduit inside wall, ceiling etc for 5 amps socket on same board complete all as specified and directed.
Description same all as per Item No 5.0 here in before but in existing concealed conduit inside wall, ceiling etc for 5 Amps socket on Independent board complete all as specified and directed.
Description same all as per Item No 5.0 here in before but in existing concealed conduit inside wall, ceiling etc for 15 Amps Power point socket on Independent board with 2.5 Sqmm PVC insulated FRLSH cable complete all as specified and directed.
Material & Labour for Point Wiring for one light Point/one fan point/ one call bell point, controlled by one switch with 1100 volts grade single core conforming to (IS:694 /1990) PVC insulated unsheathed 1.5 sqmm multi stranded copper conductor cable (FRLSH) with continious earth wire of 1.5 Sqmm stranded copper conductor cable (FRLSH) PVC insulated unsheathed , drawn in and including, PVC Casing Caping "medium grade" (ISI marked) , of 20 mm size fixed on wall/ceiling or above false ceiling with fittings medium grade (Color coding of wires shall be Phase, neutral and earth wire all as specified ) sunk Metal flush box with and incl decorative polycarbonate frame for housing Modular Switches, sockets , fan regulators etc including white cover plate complete all as specified and directed.
Description same all as per Item No 7.0 here in before but for 05 amps socket on same board complete all as specified and directed.
Description same all as per Item No 7.0 here in before but for 05 amps socket on Independent board complete all as specified and directed.
Description same all as per Item No 7.0 here in before but with 2.5 Sqmm PVC insulated FRLSH cable for 15 Amps power point complete all as specified & directed.
S&F switch Modular single pole, one way 6 Amps , 1 module, 230 volts, 50 hz complete all as specified and directed. Make: Legrand cat No: 6734 01/ Indoasian Cat No: 800000 or equivalent of make as specified in Appx "B" (List of make)
Supply and fixing switch modular , one-way 16Amps, 1 module 240 Volts AC complete all as specified and directed. Make: Legrand cat No: 673411/ Indoasian Cat No: 800002 or equivalent of make as specified in Appx "B" (List of make)
Supply and fix Modular Socket outlet, 6A - 2/3 pin combined, 2 module ISI marked, 230 volts, 50 hz complete all as specified and directed. Make: Legrand cat No: 673452 / Indoasian cat no: 800020 or equivalent of make as specified in Appx "B" (List of make)
Supply and fixing modular socket, 6A/16A -2/3 pin combined 2 module 230 volts, 50 hz complete all as specified and directed. Make:- Legrand cat No: 6734 55 / Indoasian cat no: 800022 or equivalent of make as specified in Appx "B" (List of make)
Supply and fixing switch modular single pole, two way 6 Amp, 1 module ISI marked, 230 volts, 50 hz all complete all as specified and directed. Make:- Legrand cat No: 6734 02 / Indoasian cat no: 800001 or equivalent of make as specified in Appx "B" (List of make)
Supply and fixing bell push modular single pole one way 6 Amps, 1 module , ISI marked complete all as specified & directed. Make:- Legrand cat No: 673022 / Indoasian cat no: 800007 or equivalent of make as specified in Appx "B" (List of make)
Supply and fixing bell ding dong 50 HZ AC 230/240 volts single pole, complete all as specified & directed.
Supply and fixing ceiling rose surface bakelite 65/25 mm dia having three terminals ISI Marked complete all as specified & directed.
Supply and fixing Fancy angle holder Metal ring insulated body with back plate, suitable for batten fittings ISI Marked complete all as specified & directed.
S&F in repairs switch piano 230 volts, AC, flush type single pole, one way 5/6 Amps ISI marked complete all as specified and directed. Make:- Anchor Cat part no HSN8536/14111 or Havells Reo Cat Part No-AHESXXW061 or equivalent of make as specified in Appx "B" (List of make)
S&F in repair switch piano 230 volts,AC, flush type white /ivory finish 15/16 Amps single pole one way complete all as specified and directed. Make:- Anchor Cat part no HSN8536/33118 or Havells Reo Cat Part No-AHESXXW201 or equivalent of make as specified in Appx "B" (List of make)
S&F in repairs, socket out let 3/5 pin 5/6 Amps flush type complete all as specified and directed. Make:- Anchor Cat part no HSN8536/14302 , or Havells Reo Cat Part No-AHEKP01W063 or equivalent of make as specified in Appx "B" (List of make)
Supply and fixing in repair socket outlet 5/6 pin 5/15 amp flush type multi suitable for 240 volts AC ISI marked complete all as specified and directed. Make:- Anchor Cat part no HSN8536/145045 ,or Havells Reo Cat Part No-AHEKUXW063 or equivalent of make as specified in Appx "B" (List of make)
Supply and fixing in repair batton/angle holder insulated body with back plate, suitable for batten fittings complete all as specified & directed.
S&F 10 Watt LED polymer Bulkhead surface mounted with opaque polymer diffuser for optimum light output IP65 environmental friendly, Voltage range-120V-280V AC,drive PF>0.98 having over voltage protection upto 400 volts.surge protection, level 7-10 Kv thermal short circuit protection THD<10% mode up of long life LED chips (SMD) in modular with Ra >70 and lumen efficiency >120 lumen watt system complete including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specifified & directed,
Supply and fix surface mounted LED luminiare, 20 watt 4 feet with all accessories having polymer extruded channel with diffuser for glare free light, high lumen output, driver PF >0.98 having over voltage protection upto 400 volts surge protection, level 7-10 KV thermal short circuit protection THD<10%, made up of long life LED chips (SMD) in modular with Ra>70 and lumen efficiency >120 lumen per watt, internally pre-wired through flexible wire connecting with ceiling rose complete all as specified & directed. Note: The firm has to give warranty for fitting including driver minimum for 2 years for any defects developed during the period.
S&F Straight Linear 10Watt, LED Tube light fitting Polycarbonate body for mirror light, 2ft long with LED light source with uniform light output, 990 lumens, Surge protection range-2KV , Voltage- 120- 280 V AC, System efficacy not less than 110 lumen /watt, power factor >0.95, THD <20%, CRI >80, CCT 6500K, fixed on site with all accessories all as specified directed,
S&F Decorative gate light made up of high grade unbreakable polycarbonate material complete with 18 Watt LED Lamp (B22) including connecting up with twine core twisted flexible copper conductor cable with suitable size of 230v, 50HZ all as specified & directed ,
S&F 36 Watt, LED Panel 2X2 Feet environmental friendly, fully diffused, using engineering grade polycarbonate diffuser, new generation, aesthetically designed, CRCA housing, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.98, thd<15%, CCT 6500K, with separate electronic driver ceiling light 36W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specified & directed,
S&F 36 Watt, LED Panel 2X2 Feet environmental friendly, fully diffused, using engineering grade polycarbonate diffuser, new generation, aesthetically designed, CRCA housing, ultra modern Surface mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/ Grid Ceiling, Voltage range – 120v- 280V AC, System efficacy – 110 Lumen / Watt, power factor >0.98, thd<15%, CCT 6500K, with separate electronic driver ceiling light 36W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specified & directed,
S&F 18 Watt LED panel 1x1 feet environmental friendly, new generation aesthetically designed flat panel for surface mounting which provides soft-light and glare free symmetrical illumination, Voltage range-120V-280V AC, system efficacy -110 Lumen/Watt, power factor >0.98, thd<15%, CCT 6500K, with separate electronic driver ceiling light 18W including connecting up with twin core twisted flexible copper conductor cable with suitable size of 230V, 50HZ all as specifified & directed,
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 8 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN (Single pole and neutral) 240V AC 4 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing sheet metal enclosure double door type for MCBs DB TPN 415V, AC 4 ways , with 200 Amps rated bus bar ,complete all as specified and directed.
Supply and fixing sheet metal enclsoure double door type for MCCB DB TPN 4 way as incomer with MCCB 4 pole, adjustable thermal & fixed magnetic type 40-63 Amp, 16 KA, 4 pole MCCB of Make Legrand, ABB, Schnedier all as specifie and directed. Note: Set the MCCB as per building load and destribute the load befor changing the cercuit.
Supply and fixing sheet metal enclosure double door type for MCBs DB SPN(Single pole and neutral) 240V AC 12 way with 200 Amps rated bus bar complete all as specified and directed .
Supply and fixing MCB SPN 10- 32 Amp 240 V AC 10 KA B curve rupting capacity complete all as specified& directed
Supply & fixing MCB, TPN, AC, 415 volts of 40-63 Amps capacity 10KA, 'B' series and making connections with suitable size of copper lugs complete all as specified & directed.
Supply and fixing MCBs, SP 6 to 32 Amp 'B' series 10 KA, 240 V, AC 50 Hz repturing capacity complete all as specified & directed.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in & including rigid PVC conduit 20mm dia or more medium grade surface/concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FR LSH) as earth wire and wire connected with main earth dolly including cutting chases and making good disturbed portion complete all as specified and directed . Note: Two runs of phase, netural wire and one run of earth wire and PVC conduit will be measured as one RM or one length.
Supply and fixing sub main wiring two single core 6 sq mm PVC insulated unsheathed stranded copper conductor cable ( FRLSH ) 1100Volts grade drawn in existing conduit surface/ concealed in wall along with 6.00 Sq mm PVC insulated unsheathed copper conductor cable (FRLSH ) as earth wire and wire connected with main earth dolly complete all as specified and as directed. Note: Two runs of phase, netural wire and one run of earth wire will be measured as one RM or one length.
S&F service cable 1100 Volts grade heavy duty cable PVC insulated stranded aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connection suspended with insulating hanger not more than 1 mtr apart including 4 mm dia suspension wire alongwith 10 Sqmm twin core flat cable all as specified and directed.
Material & labour for earthing complete with galvanised steel earth plate electrode 600x600x6mm thick burried directly in ground. ( earth pit not less than 2.25 mtr depth below ground level at any type of strata ) with top edge of the earth plate not less than 1.5mtr below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15cm all around the plate. connected by 4 mm GI wire as earth lead by means of brass nuts and bolt, thimbles check nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish, internal surface of concrete chamber shall be given internal dia 300mm x300mm, 15mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320x320x80mm size PCC 1:2:4 Type B1 using 20mm graded stone aggregate rainforced with XPM all as shown in electrical plate No 3 of MES SSR Part-1(2009) and specified including and provision of GI wire upto 7.5 mtrs long with 15 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade, including all exavation and earth work and connecting the earthing wire to panel, including testing on completion complete all as specified and directed. Note:- (i) RCC pit cover shall be precast of RCC(1:2:4) type B1, 80mm thick reinforced with XPM weighing not less than 4kg/sqm in lieu of CI cover. (ii) Cost of additional GI wire more than 7.5 mtrs will be measured and paid seperately under relevant items.
Fixing only serviceble light fitting retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable switches retrived from Item No-02 above complete all as specified and directed.
Fixing only serviceable sockets retrived from Item No-02 above complete all as specified and directed.
Taking out & removing old burnt-out winding of electric fans of size 1200/1400 mm sweep and rewinding of fan motor with appropriate size super enamelled copper wire (Make : Atlas/Finolex/Devi Dayal) as approved by the Engineer-in -charge including insulating material such as illuminous paper Leatherized paper,cotton tape,glass sleeving,insulating varnish incl ball bearing/bushes/hanging assembly if required etc testing at workshop and transportation to site,connecting and testing on full load to the entire satisfaction complete all as specified and directed.
M&L spray painting of Ceiling fans complete, in situ with synthetic enamel paint of any tint as approved by Engg-in-Charge by spraying including filling cavities with filler ,one coat after cleaning all dust of any size including fan blades and writing of MES No with black synthetic enamel paint complete all as specified and directed.
Dismantling of exhaust fan 450/380 mm sweep of any make/ model, opening for cutting, taking out existing unserviceable winding wire, rewinding with super enamel copper wire of existing gauge, including varnishing and insulating material with washer, split pin, checknut, hanging clutch, condenser clamp, assembling,with required flexible wire . and testing complete all as specified and directed.
Description same all as per Srl item 46 above but for exhaust fan 350/300 mm sweep. complete all as specified and directed.
Description same all as per Srl item No 46 above but for exhaust fan 250 mm sweep. complete all as specified and directed.
Taking down exhaust fans 450/380/350/300/250/200 mm sweep, removing and cleaning of dust properly, oiling and greasing of bearing with and including replacement of washer, new split pin & any other minor spare parts such as new screw, checknut, pin etc and refixing in position, connecting, testing complete all as directed by EIC.
S&F in replacement of condensor 4 MFD suitable for exhaust fan complete all as specified and directed.
S&F in replacement of condenser 3.15 MFD exhaust fan complete all as specified and directed.
Spray painting of Exhaust fans of any size including fan blades, after scrapping and cleaning old painted surfaces, with synthetic enamel paint complete all as specified and directed.
Panwar Electrical
M/S Ex Soldiers Mechanical Works
A ONE BUILDERS AND ENGINEERS
Neev Enterprises
S.M. KAZIM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .