Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹90.2 LAdmitted-Fee/PreQual/Technical/Finance VITHAYATHIL HOUSE S ADUVASSERY CHENGAMANADU PIN 683578 | CHENGAMANADU | ERNAKULAM | KERALA | 683578 | L1 | Admitted-Fee/PreQual/Technical/Finance | |
| 2 | L2₹91.7 L+₹1.5 L (1.68%)Admitted-Fee/PreQual/Technical/Finance PILACHIKKATTIL HOUSE KOLAKKAD P O CHERPULASSERI VIA PALAKKAD DIST 679503 | CHERPULASSERI | PALAKKAD | KERALA | 679503 | L2 | Admitted-Fee/PreQual/Technical/Finance | |
| 3 | L3₹94.9 L+₹4.6 L (5.15%)Admitted-Fee/PreQual/Technical/Finance M S SURAS AGENCIES AND ELECTRICAL ENGINEERING WORKS T B ROAD MANJERI MALAPPURAM DT 676121 | MANJERI | MALAPPURAM | KERALA | 676121 | L3 | Admitted-Fee/PreQual/Technical/Finance | |
| 4 | L4₹96.0 L+₹5.8 L (6.47%)Admitted-Fee/PreQual/Technical/Finance | L4 | Admitted-Fee/PreQual/Technical/Finance | |
| 5 | L5₹1.1 Cr+₹18.5 L (20.5%)Admitted-Fee/PreQual/Technical/Finance ATTUKAL BHAVANAM T C 20 1735 1 SASTHRI NAGAR EAST KARAMANA P O THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695002 | L5 | Admitted-Fee/PreQual/Technical/Finance |
| Sl No | Description | Qty | Unit | VISAKH M R L5 | SURAS AGENCIES L3 | PAUL V.O. L1 | SIVADAS P K L2 | Elecon Energy Solutions Pvt Ltd L6 | TKM Infra Projects L4 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, Erection ,Testing and Commissioning of 110 HP Centrifugal motor pumpset | |||||||||
| 1.00 | OD63254/2026-2027:Supply, erection, testing and commissioning of KWA pre-qualified reputed make Water lubricated Horizontal Split Case Centrifugal pump set having a Duty conditions of 82 lps & 70 m head, with Bronze impeller, SS shaft, Steel Columns, Steel Strainer, CI Bowls & Bell mouth, CI Discharge head, Bronze wear rings having coupled motor of KWA pre qualified reputed make horizontal solid shaft pump mounted TEFC squirrel cage 4 pole induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEF1/IS 325 digital motor protection relay shall be included in starter as per present IE rules with foundation bolts & nuts, base frame for pump and motor etc. complete including providing suitable concrete foundation in RCC with CC not less than 1:1.5:3 in 20 mm broken stone, fixing of M.S base frame on the concrete foundation, fixing of pump and motor and coupling them with suitable coupling including cost of cement, sand and broken stone and all other materials, labour charges, hire charges etc. complete. The alignment of the Pump and Motor coupled shall be with out any vibration during running. The combined efficiency of pump and motor shall not be less than 70% | 1 | no | 30,96,200.1 ₹30,96,200.1 | 26,06,068 ₹26,06,068 | 28,12,500 ₹28,12,500 | 26,10,067.74 ₹26,10,067.74 | 20,62,500 ₹20,62,500 Lowest | 25,00,000 ₹25,00,000 |
| 1.00 | OD63252/2026-2027:Supply, erection, testing and commissioning of suitable rating soft starter with air break contact. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. | 1 | no | 1,84,709.4 ₹1,84,709.4 | 1,55,362 ₹1,55,362 | 2,50,000 ₹2,50,000 | 1,55,708.3 ₹1,55,708.3 | 3,25,000 ₹3,25,000 | 1,55,000 ₹1,55,000 Lowest |
| 1.00 | OD63256/2026-2027:Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer, suitable rating ELCB/ELR, suitable rating Single phasing preventor, subitable rating Change Over Switch and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Panel board including MCCBs, Bus bars & accessories shall be suitable for a min. rating of 200 amps or suitable for the motor. The panel board shall be connected to Main Switch Board using suitable rating Copper Cables | 1 | set | 2,13,259.12 ₹2,13,259.12 | 1,79,376 ₹1,79,376 Lowest | 2,25,000 ₹2,25,000 | 1,79,576.13 ₹1,79,576.13 | 3,12,500 ₹3,12,500 | 1,90,000 ₹1,90,000 |
| 1.00 | OD63258/2026-2027:Supply, laying, testing and commissioning of suitable size XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE of necessary length and free runs for the above pump set from panel board to starter and from starter to motor considering energy conservation. | 1 | set | 16,405.03 ₹16,405.03 | 13,797 ₹13,797 Lowest | 40,000 ₹40,000 | 13,829.28 ₹13,829.28 | 1,62,000 ₹1,62,000 | 15,000 ₹15,000 |
| 1.00 | OD63257/2026-2027:Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. | 1 | set | 16,405.03 ₹16,405.03 | 13,797 ₹13,797 Lowest | 15,000 ₹15,000 | 13,829.28 ₹13,829.28 | 85,000 ₹85,000 | 15,000 ₹15,000 |
| 1.01 | OD63259/2026-2027:Supply, erection, testing and commissioning of APP Metalised poly propeline capacitor Heavy duty, 440V Cylinderical Gas filled type capacitor / Capacitor bank for the motor to get a power factor above 0.98. The capacitor shall confirm to IS 2834. | 1 | no | 16,405.03 ₹16,405.03 | 13,797 ₹13,797 Lowest | 15,000 ₹15,000 | 13,829.28 ₹13,829.28 | 70,000 ₹70,000 | 15,000 ₹15,000 |
| 1.01 | OD63255/2026-2027:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Double Flanged Non return valve, both with PN 16 pressure rating including cost of all materials, labour, hire charges etc. complete. Valve sizes shall match the delivery size of the pump. | 1 | set | 32,810.05 ₹32,810.05 | 27,596 ₹27,596 Lowest | 32,000 ₹32,000 | 27,658.56 ₹27,658.56 | 3,15,000 ₹3,15,000 | 28,000 ₹28,000 |
| 1.01 | OD63253/2026-2027:Supplying, Fabricating and fitting of suitable size best quality GI/MS pipe of thickness not less than 10mm suitable for the above pump and connecting the suction side of the pump and delivery side of the pump with the Sluice valves, Non-Return Valves, suitable specials, flanges, nut and bolts IR sheet etc. complete to connect with the 300 mm DI K9 pumping main including cost of all GI & MS pipe and specials, MS flanges with min. of 12 mm thickness, DI K9 pipes if required, DI K-12 Specials, Cast Iron foot valves for each pump of size matching the suction pipe, Pressure guage with 6" dial and having stop cock, necessary anchor blocks in RCC with CC not less than 1:1.5:3 in 20 mm broken stone including cost of all materials, labour, hire charges etc. complete. All interconnections of pipe lines in the delivery side of the pump shall be done in "Y" pattern only. NRV shall be support with RCC Anchor Block. | 1 | set | 32,810.05 ₹32,810.05 | 27,596 ₹27,596 Lowest | 30,500 ₹30,500 | 27,627.9 ₹27,627.9 | 6,95,000 ₹6,95,000 | 30,000 ₹30,000 |
| 2.00Supply, testing, erecting & commissioning of 315 KVA Oil immersed Outdoor Type transformer with yard, cabling and allied work at WTP compound , Kayarampara | |||||||||
Tender Value
₹1.0 Cr
EMD Value
₹50,000
Closing Date
26 Nov 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Superintending Engineer
Kerala Water Authority, PH Circle, Kalamandapam Palakkad
Supply , Erection, Trial running and commissioning of Clear water Centrifugal Motor pump at Kayarampara WTP to Cherikkunnu GLSR , Supply , erection and commissioning of 315 KVA Transformer with Yard at Kayarampara WTP compound and Linking works
2026_KWA_890370_1
12/26-27/SE/PHC/PKD
Open Tender
Civil Works - Water Works
Item Rate
Ottappalam Municipality- Kayarampara
Please refer Tender documents.
9 documents required · 9 mandatory
₹5,515
₹50,000
Yes
27 Nov 2026
19 Nov 2026
27 Nov 2026
19 Nov 2026
26 Nov 2026
19 Nov 2026
120 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Erection ,Testing and Commissioning of 110 HP Centrifugal motor pumpset | |||||
| 1.001 | OD63254/2026-2027:Supply, erection, testing and commissioning of KWA pre-qualified reputed make Water lubricated Horizontal Split Case Centrifugal pump set having a Duty conditions of 82 lps & 70 m head, with Bronze impeller, SS shaft, Steel Columns, Steel Strainer, CI Bowls & Bell mouth, CI Discharge head, Bronze wear rings having coupled motor of KWA pre qualified reputed make horizontal solid shaft pump mounted TEFC squirrel cage 4 pole induction motor suitable for the above pump working 3 phase 50 Hz AC supply, working voltage 415V. The motor shall confirm to EEF1/IS 325 digital motor protection relay shall be included in starter as per present IE rules with foundation bolts & nuts, base frame for pump and motor etc. complete including providing suitable concrete foundation in RCC with CC not less than 1:1.5:3 in 20 mm broken stone, fixing of M.S base frame on the concrete foundation, fixing of pump and motor and coupling them with suitable coupling including cost of cement, sand and broken stone and all other materials, labour charges, hire charges etc. complete. The alignment of the Pump and Motor coupled shall be with out any vibration during running. The combined efficiency of pump and motor shall not be less than 70% | 1 | no | - | - |
| 1.002 | OD63252/2026-2027:Supply, erection, testing and commissioning of suitable rating soft starter with air break contact. Starter suitable for the above motor with over voltage and under voltage protection, single phase preventer, over load relay with motor protection relay with main contactor and bypass contactor as per IE rules and code of practice etc. complete. | 1 | no | - | - |
| 1.003 | OD63256/2026-2027:Supply, erection, testing and commissioning of cubical type floor mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. suitable capacity MCCB as incomer, suitable rating ELCB/ELR, suitable rating Single phasing preventor, subitable rating Change Over Switch and fitted with 3 Nos of indicator lamps, 1 No. volt meter with selector switch, 1 No. Ammeter with selector switch etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. Panel board including MCCBs, Bus bars & accessories shall be suitable for a min. rating of 200 amps or suitable for the motor. The panel board shall be connected to Main Switch Board using suitable rating Copper Cables | 1 | set | - | - |
| 1.004 | OD63258/2026-2027:Supply, laying, testing and commissioning of suitable size XLPE insulated armoured cable with aluminium conductors for working voltages up to and including 1100 volts conforming IS 1584/part I/1988 for PVC IS 7098 part I for XLPE of necessary length and free runs for the above pump set from panel board to starter and from starter to motor considering energy conservation. | 1 | set | - | - |
| 1.005 | OD63257/2026-2027:Supply of all materials and providing suitable earthing by using suitable size pipe/plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter, panel board etc. as per IE standards. | 1 | set | - | - |
| 1.006 | OD63259/2026-2027:Supply, erection, testing and commissioning of APP Metalised poly propeline capacitor Heavy duty, 440V Cylinderical Gas filled type capacitor / Capacitor bank for the motor to get a power factor above 0.98. The capacitor shall confirm to IS 2834. | 1 | no | - | - |
| 1.007 | OD63255/2026-2027:Supply of suitable size best quality heavy duty ISI marked CI double flanged sluice valve and Double Flanged Non return valve, both with PN 16 pressure rating including cost of all materials, labour, hire charges etc. complete. Valve sizes shall match the delivery size of the pump. | 1 | set | - | - |
| 1.008 | OD63253/2026-2027:Supplying, Fabricating and fitting of suitable size best quality GI/MS pipe of thickness not less than 10mm suitable for the above pump and connecting the suction side of the pump and delivery side of the pump with the Sluice valves, Non-Return Valves, suitable specials, flanges, nut and bolts IR sheet etc. complete to connect with the 300 mm DI K9 pumping main including cost of all GI & MS pipe and specials, MS flanges with min. of 12 mm thickness, DI K9 pipes if required, DI K-12 Specials, Cast Iron foot valves for each pump of size matching the suction pipe, Pressure guage with 6" dial and having stop cock, necessary anchor blocks in RCC with CC not less than 1:1.5:3 in 20 mm broken stone including cost of all materials, labour, hire charges etc. complete. All interconnections of pipe lines in the delivery side of the pump shall be done in "Y" pattern only. NRV shall be support with RCC Anchor Block. | 1 | set | - | - |
| 2Supply, testing, erecting & commissioning of 315 KVA Oil immersed Outdoor Type transformer with yard, cabling and allied work at WTP compound , Kayarampara | |||||
stage.html
html • 0.03 MB
finance_1522401.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 1.93 MB
BOQ_1522401.xls
BOQ • 0.36 MB
NITdocs12.pdf
Tender Documents • 15.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .