Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹87.4 LAccepted-AOC | L-1 | Accepted-AOC lowest bidder | |
| 2 | Rejected-Technical | - | Rejected-Technical Technical Document not as per requirement | |
| 3 | Rejected-Technical PO DHARCHANDNA TEHSIL CHOPAL DISTT SHIMLA | - | Rejected-Technical Technical Document not as per requirement |
Tender Value
₹88.9 L
EMD Value
₹2.2 L
Closing Date
9 Jun 2021, 1:00 pmClosed
Lokesh Thakur
SE(OP) Circle
Construction of 33/11 KV Sub-Station at Maliana/Chamyana to Super Specially Block IGMC Shimla under Electrical Division No-II, HPSEBL, Shimla-9
2021_HPSEB_47272_1
DB/Tender-06(Civil work Chamyaba)/2021-22
Open Tender
Supply and Erection
Turn-key
90 days
Chamyana
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,900
Sr. Executive Engineer, Electrical Division No. II
₹2.2 L
10 Aug 2021
10 May 2021
10 Jun 2021
10 May 2021
9 Jun 2021
10 May 2021
Amount
Control Room Building
Excavation in foundations, trenches etc., in earth work, lift upto 1.50 Meters stacking the excavated soil not more than 3 meters clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundations etc., consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth as directed with in all leads and lifts.
Providing and laying cement concrete 1:4:8 (1 cement:4 sand:8 graded stone aggregate 40mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth:
Providing form work with steel plates 3.15mm.thick welded with angle iron in frame 30x30x5mm. so as to give a fair finish including centering, shuttering, strutting and propping etc. with wooden battens and ballies, height of propping and centering below supporting floor to ceiling not exceeding 4 Mtrs. And removal of the same for insitu-reinforced concrete & plain concrete work in: i) Foundation, footings basis of columns etc. and mass concrete.
ii) Flat surfaces such as soffits of suspended floors, roofs, landings and the like. In slab
iii) Columns, pillars, Posts and Struts.
iv) Beams, cantilever, girders and lintels.
v) Edges of slabs and breaks in floors and walls: Under 20 cm. wide.
Providing and laying cement concrete 1:2:4 (1 cement:2 Sand:4 graded stone aggregate 20mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth
Providing and laying cement concrete 1:1.5:3 (1 cement :1.5: Sand : 3 graded stone aggregate 20 mm nominal size and curing complete excluding cost of form work. Foundation and plinth :
Walls including attached buttresses, pilasters and their caps and bases string courses etc. up to floor two level.
Independent piers, columns and pillars up to floor two level.
Providing mild steel/Tor steel reinforcement for R.C.C. work including bending, binding and placing in position complete up to floor two level : Tor Steel.
Providing and laying damp proof course 38mm thick with cement concrete 1:2:4 (1 cement:2 sand:4 stone aggregate 12.5mm nominal size) and curing complete.
Applying a coat of hot bitumen (mexphalt 80/100 or equivalent) using 1.70 kg. per square meter on damp proof course after cleaning the surface with a piece of cloth lightly soaked with kerosene oil.
Boulder filling dry hand packed tightly under floors.
Providing and fixing anodized aluminium work for door, window, ventilators and partitions with extruded built up standard tubular and other sections of approved make conforming to IS 733 and IS 1285 anodized transparent or dyed to required shade according to IS 1868. (Minimum anodic coating of grade AC 15) fixed with raw plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically where ever required including cleats angle, aluminium, snap beading for glazing/panelling C.P. brass/stainless steel screws. All complete as per architectural drawings and the directions of Engineer-In-Charge. a) For doors windows and ventilators and glazed partitions frames.
For shutters of doors windows & ventilators including providing and fixing hinges/pivots and making provisions for fixing of fittings where ever required including the cost of PVC/neoprene gaskets as required (fittings and glazing/panelling shall be paid for separately).
Providing and fixing glazing in aluminium door, window, ventilator shutters and partition etc with PVC/neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer-In charge (cost of aluminium snap beading shall be paid in basic item.) Glazing with glass panes of 5.50mm thickness (weight not less than 13.75 kg/ sqm.
Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture i/c top and bottom pivot & double action hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required fittins, all complete as per direction of Engineer in charge.
Providing and fixing double action hydraulic floor spring of approved brand and manufacture (conforming to IS 6315) for aluminium door including cost of cutting floor as required embedding in floors and cover plates etc. complete as per the direction of Engineer-In-Charge I/c making good the floors.
Brick work using common burnt clay building bricks in foundation and plinth in Cement Mortar 1:4(1cement : 4 sand) 1st Class Bricks - Super-structure above plinth level up to floor two level.
Half brick masonry in common burnt clay building bricks in :- Cement Mortar 1:4 (1 cement : 4 sand) First Class Bricks
Providing and laying cement concrete 1:3:6 (1 cement : 3 sand : 6 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work in: Foundation and plinth
6mm Cement plaster to ceiling. (a) In Cement mortar 1:3(1 Cement:3 Sand)
20mm Cement plaster in two coats ,backing coat 15mm and finishing coat 5mm thick on rough side of brick/stone masonry walls for interior plastering up to floor two level including arises, internal rounded angles ,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (ii) Cement Mortar1:4 (1cement:4 sand).
15mm Cement plaster in two coats ,backing coat 15mm and finishing coat 5mm thick on rough side of brick/stone masonry walls for interior plastering up to floor two level including arises, internal rounded angles ,chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth. (ii) Cement Mortar1:4 (1cement:4 sand).
Kota stone slab flooring 20 mm (average) thick base of cement mortar 1:4 (1 cement :4 sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab. including rubbing and polishing complete25 mm thick.
P/F 10mm thick antiskid water proof stain and impact resistant heavy duty vitrified tiles Nitco or equivalent 600mmx600mmx10mm manufactured of approved shade and colour in flooring, tread of steps and landing laid over 12mm thick cement mortar 1:3(1 cement: 3 Sand) jointed with cement slurry mixed with pigment to match the shade of tiles as required complete.
Providing and laying 20mm. thick acid proof tiles of size up to 300 x 300mm. of specified shade in floors, treads of steps and landing laid on a bed of 12mm. thick cement mortar 1:3(1 cement: 3 sand) jointing with cement slurry mixed with pigment to match the shade of tiles.
Providing and laying spartic ceramic tiles 5.5mm.thick in flooring (300 x300mm. size)treads of steps laid on a bed of 12mm. thick cement mortar 1:3(1cement: 3 sand) finished with flush pointing in white cement
White glazed tiles 6 mm thick in flooring, treads of steps and landing laid on a bed of 12 mm thick cement mortar 1:3(1 cement :3 sand) finished with flush pointing in white cement.
S/F rolling shutters of approved make made of 80 mm X 1.25mm M.S laths interlocked together through their entire length and joined together at the end by end locks mounted on specially designed pipe shaft, with brackets side guides and arrangements for inside and outside locking with push pull operation complete but excluding the cost of the top cover and spring.- Shutters having width 3.5 meters and above
P/F 27.5 centimeter long wire spring grade No.2 for rolling shutters
P/F top cover for rolling Shutters having width 3.5 meter and above
Providing and fixing on wall face PVC (D-Plast) rain water pipes of working pressure not less than 4.5 kg/sqm including filling the joints with approved adhesive complete- 100mm dia pipes
P/F on wall faces PVC (D-Plast) accessories for rain water pipes including filling the joints with approved adhesive complete. PVC Plain bend 100mm dia
Providing under layer for plinth protection of 75mm thick (unconsolidated) bed dry brick/stone aggregated 40mm nominal size with rammed and consolidated and grouted with fine sand including preparation of ground
Constructing Course rubble hammer dressed ‘U’ shape open surface drain with side wall. 15x22 cm in cement mortar 1:6 (1 Cement : 6 Sand) and inside plastering with cement plaster 1:3 (1 Cement:3 Sand) including earth work and laying 10 cm cement concrete in 1:5:10 (1 Cement : 5 Sand : 10 graded stone aggregate) of 40 mm nominal size) and 7.5 cm cement concrete 1:2:4 (1 Cement : 2 Sand : 4 Graded stone aggregate of 20 mm nominal size) and finished with a floating coat of neat cement complete as per standard design.
P/F bright finished brass 100mm. Mortice latch and lock and a pair of levers, handles with necessary screws etc. complete (Indian make of approved quality)
Providing and fixing anodized aluminium sliding door bolt anodized colour and shade with bolts and nuts screws etc. complete:- 300x16mm
Providing and fixing aluminium tower bolts (barrel type) anodized trans parent or dyed to required shade and colour with screws etc. complete:-a) 250x10 mm
Providing and fixing aluminium handles anodized transparent or dyed to required colour & shade with necessary screws etc. complete. 125 mm
Applying Birla white wall care putty over plaster surface after thoroughly brushing the surface free from mortar drops, dust, loose materials and other foreign matters sand papered smooth to give final matter finish to the surface complete.
Applying priming coat on new concrete/ masonry /asbestos cement plastered surfaces after and including preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required with : Ready mixed primer Qty. same as item No. 37 i.e. = 757.71 Sqm
Finishing wall with weather proof exterior grade emulsion of approved design (Apexultima) or its equarlied on undecorated wall surfaces (two coats) to give an even shade and final finish after thoroughly cleaning the surface to remove all dirt, dust and other foreign matter etc including sand paper smooth complete.
Wall painting (two coats) with acrylic emulsion paint of approved brand and manufacture for interior grade on undecorated concrete/stone/plastered wall surfaces to give an even shade including t thoroughly brushing the surface free from mortar dropping and other foreign matter and sand papered smooth including applying of putty a required for melting the surface.
Steel work welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of red lead paint. a) In grafting framed guard bars, ladders, railing, brackets and similar works:- Lump sum for staircase railing.
Steel work in single sections including cutting, hoisting fixing in position and applying a priming coat of red lead paint in R.s. joists, channels angles, tees.
P/F 6mm thick MS chequered plate including priming and painting two coats.
P/F moulded hand rail of M.S. hollow pipe 50mm dia welded in straight length over M.S. flat at top of vertical balusters including one coat of red oxide primer coat complete.
Gate Fencing
Excavation in earthwork and disposal of all excavated earth up to a lead of 20meters, disposed earth to be leveled and neatly dressed: - P/J work.
P/L cement concrete work 1:2:4(1cement :2sand:4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work in foundation, and plinth.
Steel work in single sections including cutting, hoisting fixing in position and applying a priming coat of red lead paint in R.s. joists, channels angles, tees.
S/F woven plains G.I. wire fencing of mesh 50mm to 150mm to any type of standard rails, straining bolts etc. i/c provision of binding wire staples etc.
Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:4(1 cement :4sand) second class bricks
S/F galvanized steel bar-bed wire (IS:278-1962Type-1) weighting 9.38 Kg. per meters (minimum) striating and fixing to any type of standard rails, striating bolts including securing with and provision of galvanized mild steel wire, staples or steel pins etc. as directed (posts and struts of wood concrete, steel etc. and straining bolts shall be paid for separately
15mm cement plaster in single on fair side of brick/concrete /stone walls for interior plastering up to floor two level including arises internal rounded angles , chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth Cement mortar 1:4(1cement 4sand).
Finishing wall with water proofing cement paint of approved brand and manufacture and of required shade on undecorated wall surfaces (two coats ) to give an even shades after thoroughly brushing the surface to remove all dirt and remains of loose powdered materials.
P/F welding mesh fencing 10 gauge thickness and mesh with 25mmx25mm including ( one coat) of red oxide primer and Two coat of black paint finished with even and smooth.
Transformer Foundation
Excavation in foundations, trenches etc.,in earth work , lift up to 1.50meters stacking the excavated soil not more than 3 meter clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundation etc. ,consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth in all kinds of soil and in all leads.
Providing and laying cement concrete 1:4:8 (1 cement : 4 sand 8 Graded stone aggregate 25 nominal size) and curing complete excluding cost of form work in foundation and plinth in breast and retaining walls etc.
Providing form work with steel plates 3.15mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish including shutering struting and proping etc with wooden battens and ballies, height of proping and centring below supporting floor to ceiling not exceeding 4 mtrs. and removal of the same -Vertical surface such as walls (any thickness) partitions and the like including attached pillasters buttresses, plinth and string course and the like
P/L cement concrete work 1:2:4(1cement :2sand:4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of form work in and reinforcement for reinforced concrete work in foundation, footings bases of columns and the like an mass concrete.
Providing mild steel /tor steel reinforcement for RCC work including bending binding and placing in position complete up to floor two level Tor steel
Steel work in single sections including cutting, hoisting fixing in position and applying a priming coat of red lead paint in R.s. joists, channels angles, tees.
15mm cement plaster in single on fair side of brick/concrete /stone walls for interior plastering up to floor two level i/carrises internal rounded angles , chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth C.M. 1:6(1cement 6sand)
Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:4(1cement 4sand) second class brick
Providing and fixing R.C.C. Trench Top cover
Provinding G.I. drain pipe (100mm diameter)= 2x4 Mtr. Long
Provinding stopper for transformer wheel.
Sanitary fitting
P/f to wall ceiling and floor galvanized mild steel tubes (medium grade) tube fitting and clamps i/c. making good the wall, ceiling and floor: - 15mm nominal bore.
P/f PVC Water storage tank complete in all respect
P/f high pressure PVC spigot and socket soil ,waste and ventilating pipes ISI marked including fixing with approved adhesive (1)75mm nominal size .
P/f PVC door bend with oval access door insertion rubber washer 3mm thick bolts and nuts complete including fixing with approved adhesive etc. (a)Plain (1) 75mm nominal size
(b)Bends of required degree with oval access door (1)75mm nominal size
(c )Single equal branch of required degree with oval access door insertion rubber washer 3mm thick bolts nuts complete (1) 75mm nominal size.
(d)Collar:-(1) 75mm nominal size
P/f. PVC floor trap ISI marked of self cleaning design including fixing with approved adhesive cost of cutting and making good the wall and floor etc complete.110X75mm
P/f vitreous china wash ,down water closet (European type W.C. pan) with integral “p” or “s” trap i/c. jointing the trap with soil pipe in cement. Mortar 1:1 (1cement 1 sand) seat and cover to be measured and paid for separately): - Anglo Indian (universal closet).
P/f vitreous china wash basin with single hole for pillar tap with CI or M.S. Brackets painted white i/c cutting holes and making good the same but excluding fittings :- Flat back :- 630x450mm
P/f 10/12. 50/15.00 ltrs. vitreous china low level flushing cistern with a pair of cast iron .or mild steel brackets, complete with fitting such as lead value less siphon, 15mm nominal size brass ball valve with polythene float C.P. brass handle union and couplings for connections with inlet outlet and over flow pipes 40mm dia cp. flush bend i/c cutting holes in wall and making good the same and connecting the flush bend with cistern and closet (over flow) pipe to be measured and paid for separately.
P/f plastic seat (solid /hollow type) and cover for wash down water closet with cp brass hinges and rubber buffers: - hollow type colored plastic seat and cover.
P/f .CP. brass waste for wash basin or sink ;- 40mm dia.
P/f. M.I. union for wash basin or sink:- 40mm dia.
Providing and fixing 600x450mm bevelled edge mirror of superior glass mounted on 6mm .AC sheet or plywood sheet fixed to wooden plugs CP brass screws & washers.
P/f .C.P. brass bib tap with capstan head:-15mm dia.
P/f brass pillar tap with capstan head :- 15mm dia
P/f CP Brass angle valve without Nuts and pipe :-15mm dia.
P/f lead connection pipe with brass union:-45cm (L) 15mm nominal bore.
P/f Stoneware gully trap grade “A” complete with C.I. grating brick masonry chamber in cement mortar 1:5and water tight CI. Cover with frame of 300 x 300mm size (inside) the weight of cover to be not less than 2.72kg. square mouth trap :- 100x100mm size
Const. manhole with RCC top slab in 1:2:4(1cement 2sand 4graded stone agg. 20mm nominal size ) foundation concrete 1:4:8 (1cement 4 sand 8 graded stone agg. 40mm nominal size in side plastering 15mm thick with cement motor 1:3 (1cement 3sand ) finished with a floating coat of neat cement making channels in cement concrete 1:2:4(1cement 2sand 4graded stone agg. 20mm nominal size ) finished smooth complete i/c curing and testing inside size 800x800mm and 500mm deep i/c . CI covers with frame light duty single seat pattern 455x610mm internal dimension total weight of cover and frames to be not less than 38kg. weight of cover 23kg and weight of frame 15kg )with 200 mm thick walls of bricks Masonry using common burnt clay building bricks in cements mortar 1:3 (1cement 3sand ).
Cutting holes through existing brick work including making good the same in cement motor 1:6 (1cement 6sand) per cms .depth of cutting: - holes up to and i/c .400 sq.cm in area.
Cutting holes up to 15x15cm .in RCC floors and roofs for passing drains pipe etc. and repairing the holes after insertion of drain pipe etc. with cement concrete 1:2:4(1cement 2sand 4graded stone agg. 20mm nominal size) i/c finishing complete so as to make it leak proof .
P/f brass full way valve with wheel:- 15mm nominal bore .
RCC Septi Tank
Excavation in foundations, trenches etc.,in earth work , lift up to 1.50meters stacking the excavated soil not more than 3 meter clear from the edge of the excavation and then returning the stacked soil in 15cm. layers, when required in to plinths sides of foundation etc. ,consolidating each deposited layer by ramming and watering and then disposing of all surplus excavated earth in all kinds of soil and in all leads.
Providing form work with steel plate 3.15 mm thick welded with angle iron in frame 30x30x5mm so as to give a fair finish i/c centering shuttering strutting and propping etc. with wooden battens and bellies height of propping and centering below supporting floor to the ceiling not a exceeding 4 m ,and removal of the same for insitureinforced concrete and plain concrete work in : (a) Flat surfaces such as soffits of suspended floor, roofs landing and the like: Floor etc. above 200mm in thickness:
( b) Edges of slabs and breaks in floor and walls :Under 20cm. wide:
Providing and laying cement concrete 1:4:8(1cement 3sand6graded stone agg.40mm nominal size) and curing complete excluding cost of form work in foundation in plinth.
P/L cement concrete work 1:2:4(1cement :2sand:4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of reinforced concrete work in :form work and reinforcement for a) Suspended floor roofs , landing and shelves and their support, balconies, beams, girders, bressumers and cantilever upto floor two level.
b) Walls any thickness nut not less than 0.10 metre thickness) including attached pilasters, buttresses, plinth and string courses etc. from top of foundation up to all heights.
Providing mild steel /tor steel reinforcement for RCC work including bending binding and placing in position complete up to floor two level Tor steel
Brick work using common burnt clay building bricks in foundation and plinth in cement mortar 1:4(1cement 4sand) second class brick
Half bricks masonry in common burnt clay building bricks in cement mortar 1:3 second class bricks.
15mm cement plaster in single on fair side of brick/concrete /stone walls for interior plastering up to floor two level including arrises internal rounded angles , chamfers and/or rounded angles not exceeding 80mm in girth and finished even and smooth Cement mortar 1:3(1cement 3sand)
P/F sand cast/ cast iron spun spigot and socket soil, waste and ventilating pipes (lead caulked joints to be measured and paid for separately): (1) 100mm nominal size.
Prov. Lead caulked joints to sand cast iron/ cast spun iron pipes and fitting i/c testing of joints :- (1) 100mm nominal size.
P/F sand cast/ cast iron spun fitting and accessories-i) with oval access door insertion rubber washer 3mm thick bolts and nuts complete :- Plain bend 100 nominal dia
Electrical Installation
Wiring for light point/fan point/call bell point with 1.5 Sqmm PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1.5 Sqmm HRFRLS/PVC insulated single core copper conductor cable as required. ( GROUP C)
S/F metal box of 100mmX100mmX60mm deep (nominal size) on surface / recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 5 pins 5/6 amps Socket outlet and 5/6 Amps. piano type switch connections, painting etc. as required .
Wiring for light plug with 2x1.5mm2 PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. 1.5 Sqmm HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit/sub-main with2x10mm2 size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 1 No. HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required.
Wiring for power plug with 2x4mm2 PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit and earthing the light point with 1 No. 4 Sqmm HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
S/F metal box of 180mmX100mmX60mm deep (nominal size) on surface / recess with suitable size phenolic laminated sheet cover in the front including providing and fixing 6 pins 15/16 amps Socket outlet and 15/16 Amps. piano type switch connections, painting etc. as required .
Providing and fixing following type of recess mounting decorative mirror optics luminaries with powder coated CRCA sheet steel housing ,low glare paralite P 5 louvers mirror reflector, pre wired with 110V starter & 36/40w copper ballast for housing CFL( but excluding the cost of CFL), complete with all accessories, connections, testing and commissioning etc. as required:-3x36 watt-CFL (Category-A)
P/F ultra slim decorative extruded box fixture with domestic etc electronic ballast snap on installers, suitable for 28 watt FTL (TS) complete with all accessories (including on No. T-S tube) connection testing and commissioning etc as required. 1x28watt-FTL (TS) (Category-A)
Supplying and fixing of fancy wall bracket containing thread type CFL lamp holder (S) of all size and shapes, complete with all accessories but excluding CFL lamp including making connections testing etc. as required:- Fixed type wall bracket 150 dia, single lamp (Category-A).
Providing and installation of stationary storage type electric water heater (Geyser) of various size by means of Expansion- bolts with nuts and washers including embedding of expansion- bolts in the wall providing and fixing of non return value dead weight safety value, 2No. CP connection rods 18" long making good the damages electrical connection, safety value connections, testing and commissioning etc as required 25 liters capacity water heater (Category -A)
Providing installation of exhaust fan of heavy duty 300mm sweep size in the existing opening including making good the damages connections testing and commissioning etc. as required.
Supplying and erection of 6 amps to 32 amps rating 10KA breaking capacity, 240 volts, "C" curves miniature circuit breaker of following poles in the existing MCB DB complete with connections etc as required:- single pole category A
Supplying and fixing following rating double pole (single Phase & Neutral) 240 volts, residual current circuit breaker(RCCB) having a sensitivity current up to 300 Miliampers in the existing MCB DB compete with connections testing, and commissioning etc as required 63 Amps. Cat A.
S/F of following way single pole and neutral sheet steel, MCB Distribution board, 240 volts, on surface/recess complete with tinned copper bus-bar, wire-set , neutral link, earth bar ,din bar, detachable gland plate, blanking plate, cable, identification labels inter connections, phosphatised and powder painted including earthing etc. as required: - i)Single door- 8 way.
ii) Single door- 12 way.
Recess Mounting MH Down lighters MH DE 150 watt with tube rod 150 watt, Bajaj/ Hevells, Visa/ Surya or equivalent make.
Providing CFL 20 Watts.
Wiring for power plug with 4x4mm2 PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 Nos. 4 Sqmm HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
S/F ceiling rose on the existing junction box/ wooden blocks including connections etc. as required.
Supplying and fixing Bakelite batten/ angle holder including connections etc. as required.
Earthing with G.I. Earth Plate 600mmx600mmx6mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangements and watering pipe etc. (but without charcoal or coke and salt) complete as required.
Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required.
Supplying and laying 6 SWG G.I. wire at 0.50 mtr below ground level for earth electrode conductor, including soldering etc. as required.
Supplying and fixing Pin type CFL 36 watt.
Supplying and erection of 40/50/63 Amps rating 10KA breaking capacity ,240volt. ‘C’ curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required: - Double Pole Cat-A.
S/F Ding-Dong/ Electronic musical bell, suitable for DC/AC Single 230 volts complete as required.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .