| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.6 LAccepted-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | ₹32.6 L Quoted ₹37.2 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹47.0 L+₹9.9 L (26.5%)Rejected-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | ₹47.0 L+₹9.9 L (26.5%) | L2 | Rejected-AOC Not Lowest |
| 3 | L3₹49.3 L+₹12.1 L (32.6%)Rejected-AOC HARSH INFRASTRUCTURE NEAR DWARKADISH PETROLEUM NANDANA DEVBHOOMI DWARKA JAMNAGAR GUJARAT 361315 | DEVBHUMI DWARKA | GUJARAT | 361315 | ₹49.3 L+₹12.1 L (32.6%) | L3 | Rejected-AOC Not Lowest |
| 4 | L4₹64.5 L+₹27.3 L (73.5%)Rejected-AOC | ₹64.5 L+₹27.3 L (73.5%) | L4 | Rejected-AOC Not Lowest |
Tender Value
₹60 L
EMD Value
₹1.1 L
Closing Date
24 Jan 2023, 6:00 pmClosed
CWE HILLS DEHRADUN
HQ CWE HILLS, MALL ROAD, DEHRADUN CANTT- 248003
REPAIR/ MAINT OF HT OH LINE, HT CABLES, VCBS, RMU AND RATIONALISATION OF HT SYSTEM, HT 33/ 11KV PROTECTION SYSTEM/ DEHYDRATION TRANSFORMER OIL AND ITS CONNECTED ITEMS UNDER CLEMENT TOWN DEHRADUN.
2022_MES_571805_1
85389/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE CLEMENT TOWN
Class C Category b(ii)
8 documents required · 8 mandatory
₹1,000
GE CLEMENT TOWN
₹1.1 L
Yes
3 Mar 2023
28 Dec 2022
31 Jan 2023
28 Dec 2022
24 Jan 2023
12 Jan 2023
Amount
Disconnecting all in coming and outgoing cables, removing the transformer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to approved nearby workshop, for carrying out maintenance of transformer all as specified in IS -10028 (part III) - 1981 following by Opening of transformer cover, draining out oil, de-tanking core and coil assembly,cleaning, washing of dust and dirt etc from all parts including core and tank, cooling tubes of radiators, re-assembling of core and winding after carring out necessary repair and replacement of defective items including providing all necessary insulation material of appropriate class including varnishing drying out in vacuum chamber till specified IR values are achieved, complete insulation varnishing to be done and providing new gasket, nuts , bolts, and checking of leakages if any,rectifying the same by welding, checking of tap change if found faulty, repair / replace the same etc, replacement of silica gel and reassembling of complete transformer all as directed by Engr-in-Charge , including testing as per relevant IS and transporting back the transformer after repair/maintenance to the site , install it, reconnect all the incoming and out going cables by properly using insulation tape and testing complete of following capacities :-
(a) 400 to 630 KVA 11000/433 Volt Distribution transformer
(b) 63 to 315 KVA 11000/433 Volt Distribution transformer
(c ) 1.5 to 3.15 MVA 33000/11000 Power Transformers
Note :- (i) Cost of items required to be replaced will be measured and paid seperately as under relievent items of this job. The labour charge for replacing the same are deemed to be included in the rates quoted. (ii) The cost of painting inside & outside of transformer also deemed to be included in the rates quoted. (As per IS -10028 (part III) - 1981.) (iii) The standby transformer will be provided by the contractor without any extra cost for continuous power supply, while carrying out repair of transformer. (iv) Any other items which is required to be provided for smooth functioning of transformer but not specified above shall be provided by contractor without any extra cost . The cost of the same are deemed to be included in the rates quoted. (v) The inventries of all defective items to be replaced/repaired will be prepaired jointly by Engr-in Charge and contractor at the time of inspection of defective trasformer after opening at the firm's workshop. The inventries will be signed by both Engr-in Charge and contractor before starting of repair work. (vi) The transformer will be get repair from approved manufacturer /workshop having licence for the same, The firm shall be got approval from GE.
Supply only following items complete all as specified and directed :-
HV coil suitable for 11 KV distribution transformer complete alongwith insulation varnishing by vacuum impregnating (if required as per sample) and backing of coil assembly.
LV coil suitable for 11/0.415 KV complete alongwith insulation varnishing by vacuum impregnating (if required as per sample) and backing of coil assembly.
Insulating transformer oil confirming to IS 335 1993 for replacing in power/distribution transformer with dielctric strength not less than 60KV.
Silica gel breather assembly with fresh silica gel for 400 KVA to 630 KVA transformer.
Silica gel breather assembly with fresh silica gel for 100 KVA to 315 KVA transformer.
HT bushing with stud, seal etc for 400 to 630 KVA transformer.
HT bushing with stud, seal etc for 100 KVA to 315 KVA transformer.
LT bushing with stud, seal etc for 400 to 630 KVA transformer.
LT bushing with stud , seal etc for 100 KVA to 315 KVA transformer.
HT bushing with stud, seal etc for 3.15 MVA of Power transformers.
LT bushing with stud, seal etc for 3.15 MVA capacity of Power transformers.
Dial type thermometer of 150 mm dia with max temp indicator complete with resetting device and alarm contacts etc.
Gun metal gate valve 25 mm dia ISI marked form transformer drain out pipe.
Gun metal gate valve 40mm dia ISI marked form transformer drain out pipe.
M&L for Filteration/ dehydration and cleaning of transformer oil off line by dehydration plant including testing of samples before and after dehydration and filtration, dielctric strength should not less than 55 KV at 2.5 mm gap after dehydration/filtration all as specified and directed. Note:- For running of filtration plant the arrangement of electric supply / DG set should be made by contractor and the cost of same deemed to be include in quoted rate.
S&F in repairs cable jointing kit 11 KV (Earthed) grade cable for outdoor termination (end joint) Cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cabe of following size complete all as specfied and directed :-
50 to 95 Sqmm cable
120 to 185 Sqmm cable
S&F in repairs cable jointing kit 11 KV (Earthed) grade cable for indoor termination (end joint) Cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cabe of following size complete all as specfied and directed :-
50 to 95 Sqmm cable
120 to 185 Sqmm cable
S&F cable jointing kit 11 KV (Earthed) grade cable for straight through, Cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cabe of following size complete all as specfied and directed :-
50 to 95 Sqmm cable
120 to 185 Sqmm cable
S&F in repairs including installation, commisioning and testing of triple pole, mechanically operated gang operated air break switch horizontal mounted disconnecting switch consists of galvanised steel base HT insulators as per BSS/IS , non ferrous knife and spring loded arcing horn of adequate section to break mangnetizing current of the transformer, horizontal GI pipe/MS square rod of suitable length for phase seperation, adequate length of GI pipe fixed vertically for operation from ground level and operating complete in both OFF and ON position and having all ferrous parts hot dipped galvanised and non ferrous parts heavily with stand weather suitable for verticle mounting of current rating up to 400 amps, for 33000 volts, 50Hz complete all as specified and directed.
S&F in repairs including installation, commissioning and testing of HT 11 KV outdoor type gang operated triple pole air break switch suitable for Horizontal or vertical mounting fixed type complete with 12 insulator 200 amps rating and steel frame mechanically oprated mechanism consisting of operating rod of 25 mm bore light grade GI pipe of sutable length worked from ground level and with locking arrangement flat iron clamp 50 mmx6mm including MS channel of suitable size length for fixing GOD including bolts, nuts and washer complete all as specified and directed.
M&L for painting of transformer after cleaning the body surface of transformer by rubbing with emery Paper to remove oil stains, dust etc with synthetic enamel paint (1st Quality) by spray paint incl writing SM No/MES No etc of following capacity of transformer to the entire satisfaction of Engr-in-Charge :-
400 to 630 KVA 11000/433 Volt Distribution transformer
200 to 315 KVA 11000/433 Volt Distribution transformer
63 to 160 KVA 11000/433 Volt Distribution transformer
3.15 MVA 33000/11000 Volt Power transformer
1.60 MVA 33000/11000 Volt Power transformer
M&L for painting of steel tubular HT Pole 11 mtr long and mild steel work such as cross arm, clamps, nuts, bolts, etc including preparation of old painted surface and painting with black and red strip 15 cm long starting from black in alternate pattern upto 1.2 mtr hight above coping and writting pole No with black paint having existing letter size complete all as specified and directed.
S&F including laying, connecting and testing of XLPE insulated, screened, PVC bedded, galvanised steel strip armoured electric power cable (heavy duty ) 11000 Volts (Earthed) grade with stranded aluminium conductor of following cross sectional area, ISI marked, laid in cable duct/ trenches/ surface/ wall complete all as specified and directed :-
Cable 95 sqmm 3 core
Cable 120 sqmm 3 core
Excavation in trenches in any type of soil and n.exc 1.5 m wide and n.exc 1.5 m in depth for ,laying under ground electric cable and GI tubing (where provided for protection of cables), stay and getting out, trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.
M&L for sand cushioning for under ground cable with layer of fine river dry sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and directed. Note:- Punned (consolidated ) thicness of sand will be measured and paid.
M&L for un-reinforced precast concrete cable cover class HVP, type 1 with peak size 300mmx180mm x 40mm compliance with IS:5820-1970, as cable protection over sand cushioning perpandicular across the cable length wise in trenches complete all as specified and directed.
Returning, filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, in any tupe of soil complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
M&L for 80 mm bore GI tube light grade laid under road/ culvert/ drain fixed to pole wall with help of flat iron clamps etcfor cable protection complete all as specified & directed.
S&F in repairs including installation, testing and commissioning of Lighting Arresters expulsion Metal oxide type, distribution class with all fittings arrangements suitable to following capacity with and including lighting counter and cable of suitable size and core from lightning arrestor to ligting counter complete all as specified & directed :-
11000 volts grade and discharge capacity 12 KV/ 10KA
33000 volts grade and discharge capacity 36 KV/ 18KA
M&L for earthing complete with galvanished steel earth plate electrode 600x600x6.0 mm thick buried directly in ground ( earth pit not less than 2.25 mtr deep below NGL) with top edge of the plate not less than 1.5 Mtr deep below NGL, connected by galvanised iron strip 32x6mm as earth lead by means of brass nuts and bolts, thimbles, cheak nuts, washers including concrete chamber of PCC 1:3:6 type C-1 using 20 mm graded stone aggregate, with fair finish, internal surface of concrete chamber shall be given internal dia 300mmx 300mm, 15 mm thick plaster in CM 1:4 funnel with wire mesh, RCC pit cover of 320 x 320x 80 mm size (1:2:4) type B1 using 20 mm graded stone aggregate, adequate quantity of common salt, charcol etc all as shown in electric plate No-3 of MESSSR Part-I(2009) as specified including and provision of GI strip 7.50 mtr long with 40 mm dia light grade GI pipe protection and watering pipe of GI 20 mm bore, medium grade , including all excavation and earth work and connecting the earth strip toan earthing test point/panel including testing on completion complete all as specified and directed. Note :-(i) RCC pit cover shall be precast of RCC (1:2:4) type B-1, 80 mm thick reinforced with XPM weight not less than 4 Kg/sqm in lieu of CI cover. (ii) Cost of additional strip more than 7.50 mtr will be measured and paid seprately under relivant item.
S&F in repair galvanized strip 32x6 mm buried in ground complete all as specified and directed.
Dismantling of cross arms of MS channel or angle section etc complete and setting aside within 50m for further disposal complete all as specified and directed.
M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers welding, bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including of one primer coat, one under coat and one finishing coat and one finishing coat of synthetic enamel paint complete all as specified and directed.
S&F anti climbing devices, spikes type, fabricated out of M.S. bars (round, square and flat) including nuts, bolts washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed.
S&F danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts for following size complete all as specified and directed :-
For HT 25cm x 20cm size.
For 33 KV size 30cm x 22cm size.
S&F in repair galvanised iron earth wire 4.0mm dia size and streaching on over head lines as earth continuity conductor including binding at ends with aluminium/ steel binding wire at the places where complete all as specified and directed.
M&L for road cutting for laying of pipe/ cable exceeding 500 Sqcm but not exc 1000 Sqcm in cross sectional area and making good with PCC (1:2:4) type B-1 using 20mm graded stone aggragate complete all as specified and directed.
NOTES :- (i)Cost of all the material , components, repairs, elements as per above as well as other elements (except supply only of the components considerd under items herein after to the extent required and operated ) to make the VCB,s/RMUs/SF6 CB complete functional shall be deemed to be included in the quoted rate of the contractor. (ii)Individual Breaker SF6/VCB/OCB/RMUs consider as one unit and above job is to be carried out unitwise.Above job will be carried out by licenced technician as aproved by GE. (iii) Any accident/mishapenning occurred during the execution of work shall be responsibity of Contractor. (iv) All necessary tools & plants required for carried out above job will be provided by contractor and the cost of the same are deemed to be included in queoted rate. (v) Inventry of defective parts to be replaced by contractor will be prepared by joint inspection with contractor.
M&L for calibration IDMT miscroprocessor based numeric relay (Three nos overcurent and one no earth fault relay) fixed in 11 KV/33 KV HT panel by primary and secondary injection method and setting the relay tripping timing in advance to match the outgoing load on the incoming and out going feeders complete all as specified and directed. Note :(i)Individual Breaker SF6/VCB/RMUs consider as one unit and above job is to be carried out unitwise.Above job wii be carried out by licenced technician as aproved by GE. (ii) Any accident/mishapenning occurred during the execution of work shall be responsibity of Contractor. (iii) All necessary tools & plants required to carriy out above job will be provided by contractor and the cost of the same deemed to be included in queoted rate.
S&F in repairs including installation, commissioning and testing of microprocessor based numeric feeder protection relay (over current three nos and earth fault one no) with low set, high set testing type for 33/ 11 KV HT panel complete all as specified and directed.
S&F in repair of Silica Gel crystal complete in breather assembly of any type and any capacity transformers complete all as specified & directed.
S&F in repair including installation, commissioning and testing of winding temperature indicator meter range 0-120 0 C for 3.15 MVA 33/ 11 KV power transformer complete all as specified and directed.
S&F in repair including installation, commissioning and testing of oil temperature indicator meter range 0-120 0 C for 3.15 MVA 33/ 11 KV power transforme complete all as specified & directed.
S&F in repairs including laying of copper cable of size 2.5 Sqmm x 5 core from 33 KV power house to Yard for control wiring with SMC/ FRP junction box as per required at site complete all as specified & directed.
S&F in repair PVC insulated single core, un-armoured aluminium conductor of size 35 Sqmm 1100 volt grade of red, yellow, blue and black (phase indication) for jumper connections complete all as specified and directed.
S&F in repairs triple pole drop out expulsion fuse unit out door type suitable for 33 KV system current rating 400 amps mounted on insulator and steel frame complete with heavy tinned non ferrus metal spring load copper contact silver plated at contact points complete all as specfied and ditrected.
M&L for testing of Bucholz relay, winding temprature & Oil temprature Protection relay unit complete along with control wiring for its functioning including alarm in case any defects noticed the same will be rectifeid by the contractor without any extra cost complete all as specfied and ditrected. Note :- All necessary tools & plants required to carring out above job will be provided by contractor and the cost of the same are deemed to be included in queoted rate.
S&F PG clamp suitable for any size of ACSR conductor complete all as specified and directed.
Fault ditection of 11 KV under ground cable of any size 3 core with the help of automatic fault locating machine, including route tracing with the help of route tracer complete all as specified and directed. Note : The cost for any type of soil like excavation, any type of earth work, cutting of branches and bushes at site are deemed to be included in Queoted rate.
M&L for punning of tree, branches touching to electric overhead lines with growth around LT/ HT over head lines, poles and stay complete to clear span of 2 mtr all around the OH line, poles with all tools and plants as reuired at site by the contractor including cleaning the area / site complete all as specified and directed. Note: (i) Any breakdown of line caused during punning shall be made good by the contractor without any extra cost. (ii) Distance between pole to pole shall be measured as one span. (iii) Only those span will be measured in which trees are alives.
S&F in repairs including installation, commissioning and testing of gear box and charging motor 110 volt suitable for HT 33 KV outdoor VCB (Make -ABB), AC 3 phase, 50 HZ complete all as specified and directed.
Supply only of following items/ parts suitable for HT VCB 11 KV/ 33 KV/ RMU, AC 3 Phase, 50 Hz complete all as specified and directed and as per existing Make :-
Vaccume bottle type VG 2 of 11 KV VCB trolly rating 350 MVA ,current rating 800 amps.
Single phase circuit Spout RYB phase
Single pahse bus bar spout for R and B phase
Single pahse bus bar spout for Y phase
Copper flexible connection 800 amps capacity suitable for VG 2 VCB trolly
Closing coil operating on 110 Volts DC for VCB trolly
Tripping coil alongwith plunger operating on110 Volt DC for VCB trolly
Insulator for Bus bar support
Buffer for opening spring
Buffer for Closing spring
Auxiliary switch.
Limit switch.
Auxiliary contactor.
Closing coil alonwith plunger operating on 36 Volts DC for VCB trolly
Tripping lever
Triping lever clutch
Master trip relay type VAJ 110 volts
HT fuse wire made out of tinned copper suitable for 11 KV feeder of rating 15 amp
Insulation tape(empire tape) of best quality insulation class A, dry, non adhensive,tensile strength not less than 38 lbs/inch 25mm x 15 mtr ISI Marked
Supply and laying synthetic rubber insulated mats (Elastomer free from, dotted desgin, Tensile strength 15N/mm2) for following voltage for electrical purpose as per IS 15652-2006, (ISI Marked ) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed :-
2.5mm thick for voltage upto 11 KV
3.0 mm thick for voltage upto 33 KV
S&F mild steel chequered plates, 6mm or over in thickness of FE -410-W(Gde-E-250) Quality-A of approved size complete all as specified and directed. Note :- Perforations shall be made in MS sheet of size 10mm to 12mm dia at spacing 100mm c/c or as dircted by Enginner-in -charge inclding necessary provision of Handles.
M&L for installation of 3D Acrylic letter board of various sizes consisting of following specification :- (i) Frame work for glow sign board to be made with MS square pipe of size 25x25x2.6mm cut to required size incl welding, drilling holes, bending etc and painted with two coats of synthetic enamel paint over one coat of red oxide primer complete for required size complete. (ii) ACP Sheet of 0.8 mm thickness cut to required size and fixed by screwing, drilling holes, bending etc from all sides of the board except front. (iii) Acrylic sheet milky white colour 3.0mm thickness cut to required size and fixed in front. (iv) Matter for writing, Colour, type and size of font will be approved by GE. (v) Creating 3D Acrylic letters from the design approved by GE, using a laser cutting machine followed by extrading in 3D using a metthod called skirting. (vi) LED modules fitted in the hollow space beneath the 3D letters or logo of signboard with necessary electric fittings and connection from existing pole / DB complete. (vii) MS square pipe for support 100x100x5mm shall be used for support of board and painted with two coats of synthetic enamel paint over one coat of red oxide primer. Note:- (i) Grouting the support pipe in Brickwork/RCC pillars using (1:3:6) PCC shall be considered in quoted rate for this item. (ii) The support MS Square pipe to be fixed in ground/pillar all as per specified and as directed. (iii) Sintex junction box fixed with 1 MCB SP of capacity 06 to 10 Amp for ON/OFF control of glow sign board and cable for making connection from existing pole / DB / Busbar to Junction box deemed to be included in the rates quoted.
M/s Kamal Traders
Harsh Infrastructure
Som Prakash Gupta
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .