Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.4 LAccepted-AOC 79B MIG PHASE 1 INDIRA PURAM G M S ROAD DEHRADUN UK PIN 248171 | DEHRADUN | UTTARAKHAND | 248171 | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹34.3 L+₹63,116 (1.87%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L2 | Rejected-AOC R | |
| 3 | L3₹35.8 L+₹2.2 L (6.44%)Rejected-AOC 27 CHITRAKOOT ENCLAVE NEAR ANURAG NURSARY DEHRADUN 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L3 | Rejected-AOC R | |
| 4 | L4₹36.9 L+₹3.2 L (9.48%)Rejected-AOC INDEX NO E 72 HQ CWE HILLS VILL PO MEHUWALA MAPHI NEAR RAJKIYA INTER COLLEGE DEHRADUN UK | DEHRADUN | UTTARAKHAND | 248001 | L4 | Rejected-AOC R | |
| 5 | L5₹43.9 L+₹10.2 L (30.3%)Rejected-AOC 63 MANDIR LANE BALLUPUR CHOWK DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L5 | Rejected-AOC R |
Tender Value
₹47.2 L
EMD Value
₹95,000
Closing Date
25 Nov 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE IMA Dehradun
GE IMA Dehradun
SPL REPAIR TO BLDG NO EW 72 EW 73 AND EW 74 WITH TOILET IN SOUTH COMPLEX AT IMA DEHRADUN
2023_MES_625367_1
GE/IMA/T-58 of 2023-2024 9361/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹95,000
Yes
5 Jan 2024
27 Oct 2023
27 Nov 2023
28 Oct 2023
25 Nov 2023
11 Nov 2023
Amount
Taking down cement or cement lime plaster/brick tiles including raking out joints, hacking for key, scrubbing down with water etc including removal outside the IMA premises complete all as directed.
Demolition of cement concrete un-reinforced in ground floor and paving not exe 15 Cm thickness (below or above ground including removal outside the IMA premises floor provided for complete all as specified.
Demolition of cement concrete (reinforced) in chajjas or in any position not otherwise specifically provided for including removal outside the IMA premises complete all as specified.
Demolition of brick or stone masonary work built in cement mortar including all quoins, arches, pillars etc including removal outside the IMA premises complete all as specified and directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but no backing), removing serviceable tiles to store and including removal outside the IMA premises complete all as directed.
Cutting openings, through brick walls for door, window and other openings or enlarging existing opening. Converting window into door openings, etc or cutting out defective brick work for under-pinning including providing, fixing and removing shoring, cleaning and stacking bricks, removing surplus serviceable bricks, hard core etc to store and rubbish not exc. 50m, all as directed.
Forming jambs, etc to openings (to foregoing item) including cutting, toothing and properly bonding into old work, also facing, jointing and pointing to match existing work complete, all as directed.
Making good under cills or over arches, lintels and bres-cummers. Including all-pinning when necessary, all as directed.
Formwork to sides and soffits of shelves, lintels, Chajjas & similar work, rough finished flat surface of concrete, all as directed.
S&F Mild steel TMT bars 8mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, all as directed.
M&L for RCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregate), as in shelves, chajjas, beams, lintel etc, all as directed.
M&L, for PCC 1: 3 : 6 type C-1 (using 20 mm graded crushed stone aggregates) in surface channels and drains including necessary use & waste of formwork complete all as specified and directed.
Extra for forming fair finished drain or channel upto 30 Cm inner girth in cement concrete, using extra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
Surface dressing not exc 15 Cm deep in soft/ loose soil including removal out side the IMA premises complete all as specified and directed.
M&L for PCC 1:4:8 type D-2 (using 40 mm graded crushed stone agg) as in sub base of floor complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks (old size) straight or curved on plan exc 6.00m mean radius built in cement mortar (1:6), complete all as specified and directed.
M&L for Brick work with sub class 'B' bricks (old size), straight or curved on plan to any radius built in cement mortar (1:4) as in half brick wall, complete all as specified and directed.
M&L for Rendering 5 mm thick with Ready Mix plaster on ceiling, soffit of roof projectin and chhajjas of concrete surface finish even and smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering with ready mix plaster on other than fare faces of brick wall or concrete surfaces finished even and smooth without using extra cement including mixing WPC (liquid), if directed for external surfaces, all as specified and directed . Note :- WPC ( liquid ) shall be measured and paid separately. Make:- ACC/ Ultratech/ Birla/ Unicrete
Supply only liquid water proofing compound all as specified & directed
M&L for Glazed ceramic coloured tiles of size 300 mm x 450mm x 6 to 7mm thick, as in vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in same color tile grout to match with and including 10 mm thick rendering in cement mortar 1:4 finished rough surface to receive tiles complete all as directed.
M&L for Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in same color tile grout to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in cement mortar 1:6, complete all as directed.
M&L for Virified glazed Ceramic tiles 8-9 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in same color tile grout to match over and including 15mm thick screed bed in cement mortar (1:4) complete, all as directed.
M&L for Rubberised polished Glossy finish, chequered cement concrete coloured tiles 30 cm X 30cm X 25 mm thick, set, jointed & pointed in neat cement slurry in floor with grey cement & pigment to match the surface of tiles over & including 15 mm thick screed bed in cement mortar 1:6 complete including dismantling of existing tiles with screed bed of any description and in any position complete all as specified and directed.
M&L for Machine cut prepolished kota stone slab flooring 18-20mm thick laid over 20mm thick cement sand screed cement mortar 1:6 as base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab and rubbing and polishing to mirror finish, including rounding/ moulding of exposed edges, complete all as directed.
M&L for 75 mm thick PCC 1:3:6 type C-2 (using 40mm graded crushed stone aggregate) as in plinth protection or similar places and finishing the surface even & smooth with out using extra cement including making joints 12mm wide to the full depth of PCC at every 3 meter and every change of direction and filling the same with mixture of bitumen & sand in ratio (1:1) by weight including necessary form work etc and including demolition of existing old cement concrete, complete all as specified and directed.
M&L, for Ready Mix Cement concrete M-25 (design mix) , (using 20 mm graded crushed stone aggregates) in pavement/hard-standing , any thickness, finishing the concrete surface by brooming while concrete is green, complete all as specified & directed. ( Note: - Ready mix concrete shall be brought from approved cement concrete plant)
M&L for Dividing strips of 4 to 6 mm thick of plain cement fibre board inserted vertically in position to forming construction joint 75 to100 mm deep as per site requirement, complete all as directed.
M&L for PCC 1:2:4 , type B-1 ( using 20mm crushed stone aggt)as in bed plate, cill, steps, coping or similar bands kerb etc complete all as specified and directed
M&L for Pre-cast RCC 35 mm thick 1:2:4 type B-0 (using 12.5mm graded crushed stone aggregate) as in louvers and jallies set in cement motar 1:4, in patch works including making good adjecent surfaces & all mouldings etc including dismantling existing RCC Jali, complete all as specified and directed.
Dismantling of wall and ceiling boards, plywood in partition etc of any description including cover fillets etc including removal outside the IMA premises complete all as directed.
Dismantling timber in fillets under 40 Sqcm in section ( framed work) in any position,in purlins rafters , frame of ceiling etc including removal outside the IMA premises complete all as directed.
M&L for 4mm thick E-board false ceiling (Classic) including galvanised colour coated snap grid frame for false ceiling, size of grid 605 X 605mm fixed with 1:6 mm dia GI wire suspenders one end tied to roof members and other end connected to main tee of grid framework by means of 4mm dia adjustable "J" hook consisting of two Nos washers and two nuts at 1.2 mtr centres, size of main tee 38mm X 25mmX 1.4mm, cross tee 38 mm X 25 mm X 1.4mm, angle along walls 38 mm X 25mm X 2.0 mm complete all as directed.
Taking down steel wicket gate with pintal, hold fast etc, area of ecah gate exc 2.50 Sqm and not exc 3.00 Sqm including makin good to gate pillers witn cement mortar 1:4 and removal from site all as directed.
Taking down wooden winows or ventilators frames with shutter (without taking off shutters from the frame) area not exc 1.5 Sqm each all as directed.
Taking down steel door frame/ chowkhats with steel shutter (without taking off shutters from the frame) area of exc 1.5 Sqm but n exc 4 Sqm each all as directed.
S&F Second class hard wood Plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed all as directed.
S&F Factory made 35 mm thick 2nd class hardwood Plain framed, panelled shutter (two panel) with lock rail and panel of 9mm thick commercial plywood or 12mm vaneered particle board with commercial veenering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated, all as directed.
S&F Factory made 35mm thick of 2nd class hard wood Glazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats, all as directed.
S&F Factory made solid panel PVC door shutter 30mm thick(style) consisting of frame made out of MS tubes for top & bottom rails ms frame shall be covered with heat moulded plain colour PVC "C" channel having a pvc sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail lock rail & bottom rail on either side as gap insert for top rail & bottom rail. Panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement suppling & fixing in the frame at site as per specification & drawing in SSR Part II 2010 etc complete all as directed
S&F Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube & edges will be painted to match with printed sheets complete all as specified and directed.
S&F, Aluminium Powder coated three track sliding windowwith two or more shutter with 5mm thick plain glass one shutter of stainless steel mosquito proofing with good quality bearing, handle lock etc, rubber gasket and glazing clips etc using following sections as given in JINDAL catelogue.(a) Bottom rail sec no. 20620. (b) Top & verticle rails sec no. 20621,(c) Handle sec no.20606. (d) Inter lock sec no. 20724 (e) Top & bottom & sides sec no.20844 including PVC track, lock, U chanel and L alm angle cleats etc complete all as specified and directed. .
S&F Mild steel framed work such as grills, grating etc with end of bars shouldered and/ or riveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railing framed work of water tanks and similar work including pintal hinges, holdfast, stops, hand made sliding bolts etc complete all as specified and directed
S&F Butt hinges, 100mm long, medium weight, stainless, mild steel complete all as directed
S&F 100mm long Stainless steel handle cast complete all as directed.
S&F 150mm long Stainless steel barrel tower bolt of extruded section complete all as directed.
S&F, 300mm long Stainless steel sliding door bolt with hasp staple (bolt type) and fixing clips to sheet cast or extruded section of Stainless steel complete all as directed.
S&F door stopper of Stainless steel body and tongue with rubber bush, fixed in door to stop the door with floor, all as specified and directed
S&F Brass chromium plated towel rail 600mm size fixed in repairs complete all as directed. Make- Cera / Hindware/ Prayag
S&F Mild steel ordinary rat tail rod pattern springs 200mm length including roller & roller plate complete all as specified & directed.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18 mm fixed with tinned tacks, galvanized wire of staples complete all as specified & directed
S&F Stainless steel curtain rod 20mm dia of SS conduit pipe grade -304 complete all as directed.
S&F Stainless steel heavy duty support brackets of approved quality for 20mm dia curtain rod , complete all as directed.
S&F Stainless steel decorative finals and end wall bracket of approved quality for 20mm dia curtain rod, complete, complete all as dierected.
Taking up or down existing steel tubing pipe 15mm bore including all fittings complete all as directed.
Taking up or down existing steel tubing pipe 20mm bore including all fittings complete all as directed.
S&F 15mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete all as directed.
S&F 20mm bore medium grade steel water tubing, galvanized (ISI Marked) with and including all fittings (ISI Marked) and jointed, tested and fixed complete to wall and ceiling or laid in floors etc complete all as directed.
S&F 1000 ltr capacity Rotational moulded polythylene water storage tanks three layered, ISI Marked (cylindrical vertical with closed top) hoisted and fixed in position complete all as specified in SSR Part I including dismantling/ taking out of old unserviceable 500 litre capacity water tank & removing to where directed complete all as specified and as directed.
S&F Ball valve 20mm dia high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball min weight 210 gms fixed in repairs complete all as directed. Make: Prayag, Polytuff, Shakti.
S&F 20mm bore gun metal gate valves, with on off leaver/ iron wheel head, screwed both ends for iron/GI pipe fixed in repair complete all as directed. Make: Zoloto/Leader/Kirloskar
Supply & fixed in repairs 15mm bore short body bib tap chromium plated with wall flange and aerator complete all as specified and directed. Make- Cera (Victor series)/ Jaquar/Kajaria.
Supply & fixed in repairs Chromium plated Angle valve 15mm dia (angle cock) cast complete all as directed. Make- Cera (Victor series)/ Jaquar/Kajaria.
Supply & fixed in repairs Two way chromium plated angle cock 15mm dia with wall flange fixed in repair complete all as directed. Cera (Victor series)/ Jaquar/Kajaria.
S&F in repairs, CP Health Faucet with 1 M. long chrome plated PVC tube with wall hook . Make- Jaguar, Cera , Hindware
S&F in repairs Vitreous china WHB white , flat back, size- 580x450mm,including SS angle 40x40x5mm (304 grade) angle support brackets, fixed in repairs complete all as directed. Make : Hindware , Cera Ist quality, Parryware.
Supply & fixed in repairs Chromium plated pillar tap 15mm dia , complete all as directed. Make- Cera (Victor seires)/ Jaquar/
S&F in repair, Vitreous china urinal with waste coupling, water spreader, for half stall type, snow white, size-375X390X590mm, fixed in repair complete all as directed. Make : Hindware , Cera Ist quality, Parryware.
S&F Glass partition of 12mm thick frosted/ tinted frameless toughened glass, area exc. 0.50Sqm & not exc. 0.75Sqm each, including cutting, polishing and bevelling edges all around and making holes for fixing & including stainless steel brackets fixed on wall with SS screws minimum three places in each, complete all as specified and directed
S&F in repairs Chromium plated waste coupling with fly nuts 32mm dia suitable for wash hand basin, complete all as directed. Make :- Cera/ Prayag/ Shakti
Supply and fixed in repairs PVC plain flexible waste pipe 32/ 40 mm dia suitable for wash hand basin / urinal , as approved. Make:- Prayag, Cera, Shakti.
S&F in repairs 100mm dia chromium plated grating with/without hole fixed in repair complete all as directed. Make:- Prayag, Cera, Shakti.
S&F PTMT glass shelf of 450mm long fixed with stainless steel screws, all complete as specified. Make Prayag, Cera, Hindware, Shakti
S&F in repair vitreous china wash down water closet pan (padestal pattern), white including plastic water closet seat cover, white, closed pattern flat bottom and mild steel chromium plated or aluminised hinging device, all as directed.
S&F in repairs PVC low level flushing cistern 10 Ltr capacity symphonic action type white including ball valve, float valve and handle including bracket and PVC flush pipe fixed in repair complete all as directed.
S&F Chromium Plated brass soap dish fixed in repairs complete all as directed. Make Prayag, Cera, Hindware, Shakti
S&F, PVC connections 15mm size with PTMT nuts of length 450mm, all complete as directed . Make Prayag, Cera, Hindware, Shakti
S&F, PVC connections 15mm size with PTMT nuts of length 600mm, all complete as directed .
S&F for 75mm bore PVC(SWR), waste and vent pipe single socketed pipes, in any length, with rubber ring joints, laid in trenches or in Floor including demolition & breaking of old unsv drains pipes & fittings of and description, complete all as specified and directed
S&F for 110 mm bore PVC(SWR), waste and vent pipe single socketed pipes, in any length, with rubber ring joints, laid in trenches or in Floor including demolition & breaking of old unsv drains pipes & fittings of any description, complete all as specified and directed.
S&F for PVC (SWR) Bends (any radius)/ Tee 75mm dia pipe, complete all as specified and directed
S&F for PVC (SWR) Bends (any radius)/Tee 110mm dia pipe, complete all as specified and directed
S&F for PVC (SWR) vent cowl for 75mm pipe, complete all as specified and directed
S&F for PVC (SWR) 75mm diameter of outlet floor trap and CP grating with or without hole including jointing with solvent cement complete all as specified and directed
S&F for PVC (SWR) 125/110 mm gully trap setting and jointing with solvent cement complete all as specified and directed
M&L in repairs water proofing treatment on roof slab including picking, sweeping cleaning and washing down with water to remove dust & providing water proofing treatment described as under:- (a) Surface preparation with polymer modified mortar ,GP grout mortar and filling of honey combs/ cracks with crack seal and multipurpose polymer of STP / Sikka/ Pidlite (b) Cleaning the surface and applying (Resin & Hardner) Epoxy Primer of STP/ Sikka / Pidilite ) on the cleaned surface for bonding of rubberised polyurethane based coating with the existing concrete surface. (c) Supplying, providing and applying water proofing treatment to slabs/ chajjas etc with rubberised polyurethane based coating, single component highly elastomeric seamless cold applied modified PU coating as per manufacturer's specifications or equivalent product of STP/ Sikka/ Pidilite) including all necessary surface preparation, coving using multipurpose polymer, water pond test, etc. complete all as per manufacturer's specifications and application methodology. The same coating shall be applied in two coats achieving a total thickness of 1.00mm Thick. The coating shall have dual combination of 250% elongation, complete all as specified and directed. Make : STP/ Sika/ Berger as recmmended by Engr-In-Charge and as approved by GE. Note :- Work shall be executed by authorised applicator of manufacturer only in specified layers including fibre cloth as per manufacturer's specifications/ instructions.
M&L for Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and directed.
M& L for anti termite treatment along the external wall below concrete or masonry apron, sides of drainage pipes, manholes, conduits, similar possible entry/ approach of termite in apron , using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes with cement mortar 1:2 (1 Cement : 2 coarse sand) at every 150mm centre to centre or part thereof etc.complete all as specified and directed.
M&L for at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) @ 0.5 litre/hole by drilling 6mm dia holes at a downward angle of 45 degree at 150mm centre to centre and sealing the same, complete all as specified and directed.
Complete removing of existing treatment from wall / ceilling complete all as specified and directed.
Preparation of new or previously untreated wooden surfaces of any description, not other wise described over 10cm width or girth and apply two coats of synthetic enamel paint over a coat of pink primer complete all as directed.
Preparation of newly plastered surface of wall and applying 1.00mm thick Asian acrylic damp proof wall care putty as per manufacturers instructions complete all as specified and directed.
Preparation of puttyied/ new plastered surfaces of wall and applying two coats of Oil bound distemper over one coat of primer complete all as specified and directed.
Preparation of newly plastered surfaces or scrapped surfaces and applying two coats of Apex paint ( Weather coat exterior paint) over one coat of exterior primer complete all as specified and directed.
Preparation of new steel surfaces of any description not otherwise described over 10 Cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed.
Preparation of old painted wooden surfaces of any description, over 10 cm in width or girth as in trusses, rafters, purlins etc and applying two coats of synthetic enamel paint with approved shade complete all as specified and directed
Preparation of old painted steel surfaces of any description, as on angles of fencing posts etc for sufaces over 10 Cm in width or girth and applying one coat of synthetic enamel paint with approved shade complete all as specified and directed.
Preparation of old treated plastered surfaces of wall and applying one coat of weather exterior emulsion paint (Apex paint of Asian Paint / Weather proof of berger) on walls with roller or mechanical means as directed by Engr-in-Charge, complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surface of walls, floors, etc complete all as specified.
M&L for Modular point wiring with PVC insulated and unsheathed electric cable 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 sq mm nominal cross sectional area drawn in nincluding non rigid PVC Conduit concealed in wall with all fitting not less than 25 mm dia and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including modular metal flush box of required size factory made for mounting Modular switch, regulators etc with and including Modular cover and frame , ISI marked, for the following. Make of wire: - Havells, Polycab, Anchor, SCI cables. Make of PVC conduit - AKG, Plastic Pvt Ltd, Bhagwati Plastic, Modi
One light point controlled by one, one way switch 5 Amps
One fan point/ exhaust fan point controlled by one, one way switch 5 Amps
One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board.
One 3 point 5 Amps switch socket outlet point controlled by one switch on the same board.
All as per item No.101 above but with stranded copper conductor 4 Sq mm (nominal area), two single core, PVC insulated cable 1100 Volt grade ISI-694 marked for 3 pin, 15 Amp socket outlet, independent, including PVC insulated stranded copper conductor 4 Sqmm (nominal area) single core as earth continuity conductor to common earth and connecting to earth dolly.
Supply and fix modular switch 1 way 6A, 1 Module complete all as specified. Make:- Legrand, Ancher,Havells
Supply and fix modular switch 1 way 16A, 1 Module with indicator lamp omplete all as specified. Make:- Legrand, Ancher,Havells
Supply and fix modular socket 6A, 2/3 pin combined 2 Module omplete all as specified. Make:- Legrand, Ancher,Havells
Supply and fix modular socket 6A/16A, 2/3 pin combined 2 Module omplete all as specified. Make:- Legrand, Ancher,Havells
Supply and fix modular fan regulators step type 2 module 120W omplete all as specified.Make:- Legrand, Ancher,Havells
Ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make:- SSK/ HAVELLS (Reo)/ Anchor
S & F sub main wiring with 2 x 6 + 1 x 6 Sqmm 3 run PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in AND INCLUDING Concealed conduit including one run PVC insulated unsheathed cable with multi stranded copper conductor as a earth continuity and connected upto DB of following sizes complete all as specified and directed. Note:Two run of single core PVC cable with one run of earth conductor & conduIt shall be measured as one unit. Make:- Havells/ Polycab/ Anchor/ SCI cables
S & F Surface and wall mounted LED batten fitting 2500 lumens 230 volts AC, not less than 100 lumens / watt, cool white/warm white depending upon requirement, not less than 1135 mm extruded Aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver complete. Make:- Crompton/ Philips/ Havells
Supply and fix ceiling Fan complete with blades,down rods ,230 volts ,1200 mm sweep ,min air delivery 210 CFM with service value 6.00 BEE ,with Brushless direct current motor (BLDC) including taking down old unsv serviceable fan and deposited to the store. 5 Star ratings complete all as specified. Make:- Atomberg/ Havells/ Crompton
Supply and fix metal body exhaust fan 300 mm sweep, 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc including taking down old unsv serviceable exhaust fan and deposited to the store. complete all as specified and directed. Make:- Crompton/ Havells/ Orient
S&F Batten holder including LED inverter bulb 9 watt retrofit type works on AC Normal mode and DC supply in inverter mode with inbuilt battery back up of up to 4 hours, high efficiency high lumens output ,including taking down old unsv led bulb PVC/polycarbonate type with back plate suitable for batten fittings complete all as directed. Make: Anchor Penta PC, Havells (Reo)/ Make of bulb : Philips / /Wipro /Havells
Material and labour for earthing with galvanised steel earth plate electrode 60cmX60cmX 6mm thick burried directly in ground (earth pit not less than 2.25 mtr below ground level) with top edge of the plate not less than 1.5 mtr below ground level connected to 4mm thick GI wire by means of nuts,bolts,check nuts & washers of galvanized iron or steel,protected by 15mm bore light grade galvanised iron pipe and connected to main switch board,including all necessary excavation & earth work in hard dense soill including funnel with wire mesh and watering pipe 20 mm bore medium grade galvanised iron pipe with charcoal and common salt in alternate layers of 15 cm thickness all around the GI plate electrode with concrete pit in PCC 1:3:6 type C-1 with cast iron frame including cast iron cover10mm thick hinged to CI frame and 6mm MS rod for handle and necessary testing complete all as shown in electrical plate No 3 of SSR part-I all as specified and directed.(one earthing for each main Panel )
Sheet metal enclosure, Single pole and neutral with three pin and earth plug and socket with and including one SPN MCB 20 Amps, 240 volts,10 KA complete fixed in repairs all as directed. Make: Legrand, L&T, Havells
S & F MCB DB 8 ways complying with IEC 61439 -1 & 3., sheet metal enclosures double door .The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed. Make: Legrand, L&T, Havells
S & F MCB SP /SPN complying to IS/IEC 60898, 240 volts 'C' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. All the above-mentioned speification/ technical documents from OEM shall be provided at the time of bidding of following capaity :- Make: Legrand, L&T, Havells, Schneider
MCB SP 240 volts, 50 Hz capacity 6-32 Amps
SPN 240 volts, 50 Hz capacity 40 to 63 Amps
S & F Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) 12 Way VTPN DB (FP MCCB +36 MCB,C).fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with 250 Amps fully insulated copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 DB,S protection,415 volt ,suitable for fixing FP MCCB 100/125 Amps as incomer and 24 SP MCBs or 4/8/ 12 TP MCBs (or any combination of SP/TP MCBs) outgoings of following capacity and making good the distrubed surface complete all as directed. Make :legrand L&T, Havells, Schneider Note: Suitable MCCB and outgoing MCBs will be measured separately under relavant items of this schedule)
S & F MCCB 125 Amps ,4 pole ICS=100% ICU at 415 volts with rupturing capacity 16 KA with thermal-magnetic release and adjustable overload setting . The MCCB shall have a Mechanical life = 40000 operations & Electrical life = 8000 operations of following capacity complete all as directed. Make: Legrand, L&T, Havells, Schneider
Supply and Fixing LED Flood Light fittings with complete fixing arrangemnets including taking down old unsv led flood light all as conforming to the following parameters: - (i) Syatem watt/Lumens: - Max 50 watts/total system lumen not less than 5000 lm (ii) Housing: - Single Piece Aluminium die cast body (iii) IP Rating & IK Rating: - IP66 & IK07 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - With complete fixing arangement, (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. Make:- Crompton/ Philips/ Havells
Supply and Fix water cooler with normal cooling capacity 40 ltrs per hrs and storage capacity of 80 Litres. The key features of Water Coolers should be as follows : i) Gross Volume : 80 L ii) Product colour : Steel Grey iii) No. of faucets : 02 iv) Tank Capacity : 80 L v) Body type : SS vi) Energy Efficient Compressor vii) Tropicalized Machine viii) Eco friendly Refrigerant ix) Min 40 % Electricity Savings x) Safety Compliant xi) IN SITU PUH Insulation xii) Longer cooling retention xiii) Compact Design xiv) Anti corrosive Precoated Body xv) Soft Aesthetic Design Make:- Bluestar/ LG/ Samsung/ Voltas
S&F Water purifier,wall mounted,capacity 50 LPH having function of Reverse Osmosis, UV, UF, TDS Controller, Carbon filters, including all fittings complete duly covered with MS Sheet 3mm thic all around to protect it from External Environment all as spcified and directed.Make:- Eureka Forbes/ Kent/ pureit/ LG
Supply and fixing Steel water Tubes, 'medium grade' 20 mm dia galvanised, with all fitting and fixed complete to walls and ceilings or laid in floors all as specified
Supply and Fixing Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed
Taking down the existing prepaid electric meter from present location and refixing it in other locations of respective shops including complete connections and matchup work all as directed.
M/S S P BUILDERS
M/S PUNDIR BUILDERS
M/s RK ENTERPRISES
Meher enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .