Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.4 LAccepted-AOC SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹36.0 L+₹19.0 L (112.5%)Rejected-Finance HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹21.5 L
EMD Value
₹43,000
Closing Date
7 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE KARGIL
GE KARGIL MES OFFICE KARGIL LADAKH - 194103
REPAIR AND MAINT OF E M INSTALATION OF VARIOUS UNITS AT KARGIL KAKSAR HINSKUT BUDKHARBU APATI CHANIGUND AND HARDAS ETC UNDER GE KARGIL
2022_MES_506099_1
GE/K-50/2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
KARGIL
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE KARGIL
₹43,000
Yes
28 Mar 2022
5 Feb 2022
9 Mar 2022
5 Feb 2022
7 Mar 2022
21 Feb 2022
60 days
Amount
Supply only MCCB 125 Amps,415 volts,25 ka,microprocessor released based 4 pole 415 Volts, 25 KA
Supply only MCCB 100 Amps,415 volts,25 ka,microprocessor released based 4 pole 415 Volts, 25 KA
Supply only MCCB 63 Amps,415 volts,25 ka,microprocessor released based 4 pole 415 Volts, 25 KA
Supply only MCB DP 40 Amps, 230 volts,
Supply only MCB DP 63 Amps, 230 volts,
M&L for Plain cement concrete 1:2:4 type B-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete,complete all as specified and directed by the Engr-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50m and making good surface.
S&F chain link MS galvanised fencing of GI wire 4 mm and 100x100 mm mesh complete all as specified by Engineer-in-charge.
M&L for mild steel Framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. all as specified
M&L for Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165
dismantling of steel tubular swaged poles of any length complete with cast iron base plate complete all as specified and directed.
Supplying, transporting, erecting and fixing steel tubular swaged poles type 410 SP-31 (11 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work, PCC 1:4:8 type D-2 in foundations below pole, PCC 1:3:6 type C-2 around poles and PCC 1:3:6 type C-1 as in plinth block, disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surfaces with aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/straps with synthetic enamel paint and 2 bands with black bituminous paint) from plinth block and numbering of poles, painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Supply and fixing in replacement Stay assembly complete with GI stay rod 20 mm dia 1800 mm long, MS plate 230x230x6 mm, stay bow,loop insulator, PCC 1:3:6, connecting bracket of suitable MS flat and nut bolt washers etc complete all as specified in electrical plate No 1 of SSR Part-1 including taking out old stay assembly.(excavation and PCC measured and paid separately)
dismantling of air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for replacement repair/ replacement of broken/worn out components and insulators etc. or carrying to MES store (spare/components for replacement to be provided free by department)
S&F of Switch air break gang operated triple pole mechanically operated mounted on insulator and steel frame with operating mechanism woked from ground level for current rating upto 400 Amps 11000 volts.
S&F in replacement of Lighting arresters expulsion type complete with all fittings transmission class, discharge capacity 65KA suitable for 11000 volts.
Dismantling cross-arms of M.S. channel or angle sections etc. complete and setting aside for re-use with in 50m
M& L Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
Supply fixing Earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6.3 mm thick, buried directly in ground vertically (earth pit not less than 2.25 m deep below ground level) with top edge of the earth plate not less than 1.5m below ground level , connected to GI strip size 32X6mm as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame , 15 MM dia GI pipe light grade for protection of wire etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 5 of MES Sch Part I , connected to Earthing test point all as specified and directed on testing on completion.
Taking out of XLPE cable of any type any size from trenches/pole including PCC precast cable cover.
Supply and laying of 1100 volts grade heavy duty cable PVC insulated aluminium cross sectional area 10 sq. mm 2 core In service connections complete all as specified
All as per ser item No.26 but for 16 Sqmm 2 core
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cable (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 16 sq. mm 3.5 core complete all as specified
All as per ser item No.28 but for 25 Sqmm 3.5 core
All as per ser item No.28 but for 35 Sqmm 3.5 core
All as per ser item No.28 but for 50 Sqmm 3.5 core
All as per ser item No.28 but for 70 Sqmm 3.5 core
S&F Changeover switch on load of capacity 125 A, 415 Amps, 4 pole, with metal enclosure box
S&F Changeover switch on load of capacity 160 A, 415 Amps, 4 pole, with metal enclosure box
S&F Changeover switch on load of capacity 200 A, 415 Amps, 4 pole, with metal enclosure box
S&F Changeover switch on load of capacity 320 A, 415 Amps, 4 pole, with metal enclosure box
Supply and fixing LED flood light 70 watt 230 V,AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp.
Note : Deduction for amount of Rs 49566.00 as listed in Schedule A Part - II ( Schedule of Credit) shall be made while awarding of contract.
SUMEET TRADING CORPORATION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .