| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹36,014Accepted-AOC HARIPAD VENDOR VIJAYAMMA HARIPAD 690 314 | 690314 | 1 | Accepted-AOC L1 |
Tender Value
₹50,000
Closing Date
28 Dec 2023, 5:00 pmClosed
Assistant Engineer
The office of Assistant Engineer, LID and EW Section, Karthikapally Grama panchayath, Haripad Subdivision
Public toilet Electrification S0129/24-Karthikappally
2023_LSGD_625475_2
Public toilet Electrification
Open Tender
Civil Works - Buildings
Item Rate
120 days
Karthikapally
Please refer Tender documents.
9 documents required · 9 mandatory
₹335
Yes
Yes
15 Mar 2024
20 Dec 2023
29 Dec 2023
20 Dec 2023
28 Dec 2023
20 Dec 2023
Amount
Electrification
90.2.1.1:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single Control light point with 6A, plate ceiling rose - Short point
90.2.1.3:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLS PVC insulated stranded single core copper conductor cable 650V grade, including providing switch board main and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB's shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control light point without ceiling rose - Short point
OD244126/2023-2024:Supply and fixing 6.5W Vista Glow Bulk Head fitting(WT140WLED7S CW PSU S1 PC) including connection etc as required
OD244306/2023-2024:Supply & fixing angle/ straight brass lined skrit type bakelite batten holder with 200mm polished Alu. shade,9w LED lamp & giving connection as required.
90.4.8:Charges for cutting holes suitable for accommodating exhaust fans up to 305mm sweep including plastering colour washing etc. as required.
OD244104/2023-2024:Supply, conveyance, installation, testing and commissioning of 300mm light duty exhaust fan in the existing opening,including providing suitable size PVC pipe(in case of plastic body), outer cover etc fixing necessary bolt and nuts, making good the damages etc. as required including giving connections with required length of suitable size PVC insulated and PVC sheathed 3 core round copper conductor flex wire conforming to relevant ISS.
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm
90.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
90.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door
2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps
2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps
1.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
OD244120/2023-2024:Earthing with 40 mm dia. medium class GI earth pipe 2 Mtr. long, providing 12mm dia. drilled holes minimum 20 nos along the entire length in alternate arrangement ,providing 40x25 mm GI reducer at top, test joint using 2 nos ,25x3 mm GI strip minimum size 25CM suitably shaped & tightly clamped to the pipe using 25x6 mm steel bolt & nut,washer,providing 2 nos 6 mm dia. drilled holes for clamping & bolting earth lead ,making masonary chamber with cover plate having locking arrangement etc. (charcoal & salt as required shall be filled at 30 CM dia .around the earth electrode)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD244108/2023-2024:Supply & providing anchor bolt hook type on wall/ parapet for binding KSEB service connection cable as required.
OD244109/2023-2024:Supply & installation of dust and vermin proof, 1 Phase Syntex Meter Board(GS-MB-3425 Single Compartment) and to fix KSEB meters, fuse units etc as required including fixing it on wall, making good the damages colour washing etc. as required
OD244110/2023-2024:Supply & providing 32A HRC fuse base with HRC fuse link.
OD244111/2023-2024:Supply & providing 32A ,2 way NL on existing meter box
OD244112/2023-2024:Charges for preparation of KSEB single phase service connection documents for availing single phase connection & producing to consumer.
Bidder Name
Kollamparampil
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_961680.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .