Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.7 LAccepted-AOC CHATTIKKAL HOUSE KOTTAPPADI | KOTTAYAM | KERALA | 686001 | L1 | Accepted-AOC COUNCIL ACCEPTED | |
| 2 | L2₹3.8 L+₹5,602.39 (1.51%)Rejected-Finance KOOLIYATT HOUSE KOTTAPADI | IDUKKI | KERALA | 685501 | L2 | Rejected-Finance COUNCIL REJECTED |
Tender Value
₹3.4 L
EMD Value
₹8,446
Closing Date
25 Jan 2024, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
ASSISTANT ENGINEER
Office of the Assistant Executive Engineer ,Guruvayur Municipality
Annual Plan-GURUVAYUR MUNICIPALITY 2023-24 SO 556-RENOVATION OF MUNICIPAL OFFICE CONSTRUCTION OF SEPTIC TANK-General Civil Work
2024_LSGD_645612_22
Etdr 3/24-25
Open Tender
Civil Works - Buildings
Item Rate
240 days
Guruvayur
Please refer Tender documents.
10 documents required · 10 mandatory
₹750
₹8,446
26 Mar 2024
18 Jan 2024
27 Jan 2024
18 Jan 2024
25 Jan 2024
18 Jan 2024
Amount
Constuction of septic tank at municipal office building
15.7.4:Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar
15.40.2:Dismantling precast concrete or stone slabs in walls, partition walls etc. including stacking within 50 metres lead:Thickness above 40 mm upto 75 mm
OD321881/2023-2024:Engaging Man Coolie
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 cement : 4 coarse sand : 8 graded stone aggregate 40 nominal size)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
OD321886/2023-2024:Providing soak pit - 60 cm Dia, 60cm Depth, and 75 mm shell thick RCC ring including 10 cm thick RCC covering slab ,cost and coveyance of all materials and all labour charges etc complete
50.18.7.4.2:Providing and fixing PVC, pipes fittings including fixing the pipe with clamps at 1.00 m spacing. this includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 6 Kgf/cm2 - internal work- Exposed on wall
50.18.9.9.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of Joints complete as per direction of engineer in charge.110 mm dia 6Kgf/cm2
OD322421/2023-2024:Supplying and laying interlocking tile 80mm or nearest size thickness, minimum strength M40(conforming to IS 15658:2006,for medium traffic Low volume roads) including providing a layer of 6mm aggregate for 5cm thickness, then laying interlock CC paver blocks tiles in lines and levels as per the directions of the departmental officers at site inclusive of all cost & amp; conveyance charges etc. complete.
16.78.2:Construction of granular sub- base by Providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, Carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in- Charge.With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
4.1.6:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 ( 1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size)
4.1.3:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand (zone-III) : 4 graded stone aggregate 20 mm nominal size)
Sudheerkumar
Bidder Name
Sudheerkumar
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_990042.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .