Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.8 LAccepted-AOC | L1 | Accepted-AOC Accepted being L1 | |
| 2 | L2₹22.5 L+₹29,747.60 (1.34%)Rejected-Finance | L2 | Rejected-Finance Rejected being higher than L1 | |
| 3 | L3₹22.7 L+₹48,387.35 (2.18%)Rejected-Finance | L3 | Rejected-Finance Rejected being higher than L1 | |
| 4 | L4₹22.9 L+₹63,578 (2.86%)Rejected-Finance | L4 | Rejected-Finance Rejected being higher than L1 | |
| 5 | L5₹22.9 L+₹69,971.50 (3.15%)Rejected-Finance | L5 | Rejected-Finance Rejected being higher than L1 |
| Sl No | Description | Qty | Unit | VISHAL ENTERPRISE L4 | ROY CONSTRUCTION L7 | Das and Brothers L6 | BHATTACHERJEE CONSTRUCTION L2 | MODERN CONSTRUCTION L1 | KAZI ENTERPRISE L5 | SARKAR AND COM L3 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of under ground cable including taking out old brick protection cover complete all as specified and directed. | 43 | Cum | 410 ₹17,630 | 398 ₹17,114 | 420 ₹18,060 | 452 ₹19,436 | 380 ₹16,340 Lowest | 412 ₹17,716 | 413 ₹17,759 |
| 2.00 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and directed. | 26 | Cum | 255 ₹6,630 | 278 ₹7,228 | 272 ₹7,072 | 269 ₹6,994 | 250 ₹6,500 Lowest | 270 ₹7,020 | 275 ₹7,150 |
| 3.00 | Removing excavated materials (soil) not exc. 50 m and depositing where directed at a level not exc. 1.5 m above from starting point complete all as specified and directed. | 17 | Cum | 170 ₹2,890 | 167 ₹2,839 | 160 ₹2,720 | 180 ₹3,060 | 150 ₹2,550 Lowest | 170 ₹2,890 | 181 ₹3,077 |
| 4.00 | Material and labour for sand cushioning with clean and dry river sand for protection of PVC cable with approved sand of uniform thickness. laid dry, filling in trenches and punning down in proper required layers complete all as specified and directed.
Note:- Punned down thickness shall be measured for payment. | 14 | Cum | 2,500 ₹35,000 | 2,100 ₹29,400 | 2,312 ₹32,368 | 2,626 ₹36,764 | 2,050 ₹28,700 Lowest | 2,200 ₹30,800 | 2,341 ₹32,774 |
| 5.00 | Materials and labour for brick protection cover to underground cables with sub class ‘B’ of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting Each other with gaps not exceeding 10mm complete all as specified and directed. | 1,090 | Each | 25 ₹27,250 | 24 ₹26,160 | 26 ₹28,340 | 20 ₹21,800 | 16 ₹17,440 Lowest | 20 ₹21,800 | 19 ₹20,710 |
| 6.00 | All as per item No 5.00 here in before but except brick and -ditto-.
Note: Servicicable brick shall be reused obtained from item No 1.00. | 645 | Each | 5 ₹3,225 | 5 ₹3,225 | 6 ₹3,870 | 4 ₹2,580 | 2 ₹1,290 Lowest | 8 ₹5,160 | 4 ₹2,580 |
| 7.00 | Taking down / out un-serviceable or serviceable LT UG Cables of size 6/16 sqmm and connections, laid in trenches and / or fixing with walls / poles complete all as specified and directed.
Note:- Earth work shall be measured and paid separately under respective items. | 399 | RM | 19 ₹7,581 | 24 ₹9,576 | 20 ₹7,980 | 20 ₹7,980 | 15 ₹5,985 Lowest | 20 ₹7,980 | 21 ₹8,379 |
| 8.00 | Supply and fix in repair loop in loop out junction box of size 300 x 200 x 110 mm made out of 1.6mm thick SMC sheet weather proof dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 04 nos aluminium bus bar of size 20 x 5 mm fixed on insulator and one MCB of capacity 10 Amp complete fixed on pole with and including suitable size MS flat iron clamp nut , bolt and washers of suitable size etc. complete all as specified and directed. | 72 | Each | 2,455 ₹1,76,760 | 2,300 ₹1,65,600 Lowest | 2,500 ₹1,80,000 | 2,741 ₹1,97,352 | 2,400 ₹1,72,800 | 2,400 ₹1,72,800 | 2,462 ₹1,77,264 |
| 9.00 | Supply and fix in repair 25 mm dia HDPE pipe of pressure rating 10 kgf/cm2 for passing of cable through PCC foundation from trench to cable junction box and also for protection of security light cable from junction box to light fitting with necessary clamp nuts and bolts complete all as specified and directed. | 150 | RM | 142 ₹21,300 | 136 ₹20,400 | 139 ₹20,850 | 168 ₹25,200 | 130 ₹19,500 Lowest | 150 ₹22,500 | 136 ₹20,400 |
| 10.00 | Material and labour for loop digging of the existing cable, remove the burnt cable and after dressing the cable fixing with proper lugs and connecting to the Junction box/ LT feeder pillar complete all as specified and directed | 20 | Each Job | 268 ₹5,360 | 267 ₹5,340 | 259 ₹5,180 | 268 ₹5,360 | 300 ₹6,000 | 291 ₹5,820 | 249 ₹4,980 Lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
14 Nov 2025, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR / MAINTENANCE OF HANGER LIGHTS, HIGH MAST LIGHTS, POST TOP LANTERN, PERIMETER LIGHTS INCLUDING REPLACEMENT OF CORRODED CABLE JUNCTION BOXES, REPLACEMENT OF OLD UNSERVICEABLE TIMER SWITCHES, FEEDER PILLAR BOXES FOR SECURITY LIGHT AND REPLACEMEN
2025_MES_736583_1
8667/BKP/AF OF 2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
240 days
GE AF Barrackpore
Class-E,
Category-b(i)
2 documents required · 2 mandatory
₹500
GE AF Barrackpore
₹40,000
Yes
6 Jan 2026
24 Oct 2025
17 Nov 2025
24 Oct 2025
14 Nov 2025
7 Nov 2025
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and getting out in soft/loose soil for laying of under ground cable including taking out old brick protection cover complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 250mm in soft/loose soil, complete all as specified and directed.
Removing excavated materials (soil) not exc. 50 m and depositing where directed at a level not exc. 1.5 m above from starting point complete all as specified and directed.
Material and labour for sand cushioning with clean and dry river sand for protection of PVC cable with approved sand of uniform thickness. laid dry, filling in trenches and punning down in proper required layers complete all as specified and directed. Note:- Punned down thickness shall be measured for payment.
Materials and labour for brick protection cover to underground cables with sub class ‘B’ of size 23 X 11.5 X 7.5 cm, (locally available best quality), laid dry and flat abutting Each other with gaps not exceeding 10mm complete all as specified and directed.
All as per item No 5.00 here in before but except brick and -ditto-. Note: Servicicable brick shall be reused obtained from item No 1.00.
Taking down / out un-serviceable or serviceable LT UG Cables of size 6/16 sqmm and connections, laid in trenches and / or fixing with walls / poles complete all as specified and directed. Note:- Earth work shall be measured and paid separately under respective items.
Supply and fix in repair loop in loop out junction box of size 300 x 200 x 110 mm made out of 1.6mm thick SMC sheet weather proof dust and vermin proof with hinged door and locking arrangements with slanting cover on top and provision of 04 nos aluminium bus bar of size 20 x 5 mm fixed on insulator and one MCB of capacity 10 Amp complete fixed on pole with and including suitable size MS flat iron clamp nut , bolt and washers of suitable size etc. complete all as specified and directed.
Supply and fix in repair 25 mm dia HDPE pipe of pressure rating 10 kgf/cm2 for passing of cable through PCC foundation from trench to cable junction box and also for protection of security light cable from junction box to light fitting with necessary clamp nuts and bolts complete all as specified and directed.
Material and labour for loop digging of the existing cable, remove the burnt cable and after dressing the cable fixing with proper lugs and connecting to the Junction box/ LT feeder pillar complete all as specified and directed
Supply, laying, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor) of size 16 Sqmm, 4 core, 1100 Volts grade, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench etc. with cable glands & suitable size of aluminium lugs complete all as specified and directed. Note : Earth work, brick protection and sand cushioning and GI Pipe Shall be measured and paid separately under respective item.
Supply, laying, or fixing or passing through pipe, connecting and testing XLPE insulated, PVC sheathed, armoured LT electric power UG cable (heavy duty with stranded aluminum conductor) of size 6 Sqmm, 2 core, 1100 Volts grade, confirming to IS-7098 (Part-I) laid through duct/ pipe / in trench or fixed on wall etc. with cable glands & suitable size of aluminium lugs etc complete all as specified and directed. Note :- (a) This item shall be used to replace old unserviceable cable of Hanger/Tower and wind shock aviation light. (b) When cable is required to run through wall it shall be properly fixed with saddle and which cost shall be included in the quoted rates.
Materials and labour for boring of holes of size up to 50mm dia under road without disturbing the top surface of the road and taxiway for passing through the cable complete all as specified and directed Note-Necessary infrastructure required for boring shall by arranged by the contractor and cost of the same included in quoted rates.
Supply and fix in repair galvanised iron pipe 40mm bore (light grade) for protection of cable, laid in trenches / floors / fixing on wall / pole complete all as specified and directed.
Supply and fix in repair galvanised iron pipe 25mm bore (light grade) for protection of cable, laid in trenches / floors / fixing on wall / pole complete all as specified and directed.
Materials and labour for steel tubular swaged poles, type 410 SP 31 (overall length 9.00 meter) conforming to IS-2713 (Part 1 to 3) 1980 complete with cast iron base plate, finial taper plug, bolts, nuts and washers, screws. Pole shall be painted with two coats of black bituminous paint throughout internally and externally upto planting depth and the remaining external portion shall be painted with two coats of aluminum paints over a coat of red oxide primer, painting black & yellow alternate strips of 30cm each externally from ground level upto 1.2m with synthetic enamel paint, numbering of poles including taking down old unserviciable existing pole complete all as specified and directed. Note: Excavation and earth work and PCC shall be measured and paid separately under respective items.
Supply and fix in repair LED street light fittings of 70W made of pressure die cast aluminium housing with toughened glass cover, IP66 protection, high power LEDs with secondary lenses and system efficacy should be minimum 110 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed.
Supply and fix in repair 10W cool day light white LED Bollard Light made of pressure die cast aluminium housing with inverted pyramid tripod type diffuser with 360 degree soft light distribution, IP65 protection, high power LEDs and system efficacy should be greater than 100 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed.
Supply and fix in repair 10W warm white LED Bollard Light fittings made of pressure die cast aluminium housing with inverted pyramid tripod type diffuser with 360 degree soft light distribution, IP65 protection, high power LEDs and system efficacy should be greater than 100 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device. THD shall be <10%, Power Factor >0.95, CCT 3000K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed.
Supply and fix in repair post top lantern, LED 25 watt aluminium powder coated housing , IP 65 protection and lumen efficacy of 80 lm / W . Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device, THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed.
Supply and fix in repair 50W LED Flood light made of pressure die cast aluminium housing with toughened glass cover, IP66 protection, high power LEDs and system efficacy should be greater than 110 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed.
Supply and fix in repair PVC insulated multicore FR PVC sheathed 1.5 sqmm 3 core multistrand copper conductor for connection of security light from Junction Box to security light complete all as specified and directed.
Materials and labour for painting of LT electric pole, steel tubular swaged pole (9 mtr long) of any size, any pattern with one coat of aluminium paint in full length of the pole and marking the pole with black and yellow strip (upto to 1 mtr length, 1 mtr height of PCC coping) alternatively including numbering the pole serially complete all as specified and directed.
Materials and labour for painting of LT RCC electric pole (9 mtr long) of any size ,any pattern with one coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 0.715 litre/ 10 sqm and marking the pole with black and yellow strip (upto 1 mtr length from ground) alternatively including numbering the pole searially complete all as specified and directed.
Supply and fix in repair power contactor 3 pole 65 Amps type MNX complete all as specified and directed.
Supply and fix in repair MCB 4 pole, 415 Volts, 63 amps, "C" series, breaking capacity 10 KA complete all as specified and directed.
Taking down carefully gear mechanism comprising of gear box, stainless steel rope ,Jubli clamp ,lever for lifting and lowering for high mast light 6/9 fittings from 15 meter long high mast and taking up after replacement unserviceable light fittings complete all as specified and as directed. Note: - Light fitting shall be measured seperately under respective items.
Supply and fix in repair 200W LED Flood Light made of pressure die cast aluminium housing with integrated polycarbonate IP Lens cover, IP66 protection and system efficacy should be greater than 120 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed/engraved on the LED fitting for traceability till life complete all as specified and directed.
Supply installation, commissioning and testing including providing all necessary electrical connection, LT feeder panel board (CPRI Approved), outdoor type, double door, factory made out of 3.15 mm thick CRCA sheet of size 1.2 m x 1.00 m x 0.5 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland and gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1 (using 20 mm grade stone aggregate), upto a height of 0.5m from ground level with danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc including necessary excavation work for taking out cable loop, foundation of panel board and refilling and comprising of the following accessories:- (a) Anodized Copper bus bar of capacity 400 Amp -04 Nos (b) MCCB 200 Amp fixed thermal and magnetic release type, 415 Volts 4 pole, 36 KA - 01 No ( In coming). (c) MCCB 100 Amp fixed thermal and magnetic release type, 415 Volts 4 pole, 25 KA - 02 Nos (Out going). (d) On load change over switch (open execution) 200 Amp, 415 Volt, 4 pole, 50 HZ - 01 No. (e) Indicator lamp LED type (set of three Red,Yellow,Blue)- 1 Set. Including taking down old unserviciable panel board complete all as specified and directed.
Supply installation, commissioning and testing including providing all necessary electrical connection, LT busbar box (CPRI Approved), outdoor type, double door,factory made out of 3.15 mm thick CRCA sheet of size 0.60 m x 0.60 m x 0.5 m deep having hinge opening arrangement in front and back side and bottom frame made out of angle iron of size 50x50x6mm thick and 04 nos legs 0.5 meter length with cable entry and exit circular hole with cable gland & gasket at bottom complete including painting to all internal and external exposed steel surfaces with powder coating paint (5 stage process) with duly fixed in ground with necessary PCC foundation (1:2:4) type B1 (using 20 mm grade stone aggregate), upto a height of 0.5m from ground level with danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled (white), with letters, figures and conventional skull and bones in signal red colour, fixing lugs, bolts, screws etc including necessary excavation work for taking out cable loop, foundation of panel board and refilling and comprising of the following accessories:- (a) Anodized Copper bus bar of capacity 300 Amp -04 Nos. Including taking down old unserviciable panel board complete all as specified and directed.
Material and labour for 100mm thick cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in paving / footpath / sub stn) and finished the surface fair and even including making the surface clean by cutting any type of vegetation including demolition of old damaged existing PCC surface complete all as specified and directed.
Supply fix in repair 10 KV surge protection device, 440 Volt for LED flood light and street light luminare of different wattage capacity complete all as specified and directed
Taking down PCC / steel tublar pole upto 9.00 meter long, shifting the pole at different location and refixing the pole including demolition of PCC foundation of pole complete all as specified and directed. Note- Excavation, PCC work will be measured and paid seprately under respective items.
Supply and fix in repair street light bracket made of 1.5 RM length of GI pipe of light grade of 40 mm dia in proper shaped, bend, threaded and drilling holes for wire entry and MS clamps (02 Nos) made of FI size 40x5mm with nut & bolts of suitable size in proper shape cmplete all as specified and directed.
Material and labour for PCC (1:4:8) type D-2 (using 40 mm grade stone aggregate) as in foundation and mass concrete complete all as specified and directed
Material and labour for PCC (1:3:6) type C-2 (using 40 mm grade stone aggregate) as in foundation and mass concrete complete all as specified and directed
Material and labour for PCC (1:2:4) type B-1 (using 20 mm grade stone aggregate) as in coping including form work complete all as specified and directed
Materials and labour for cross arm bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of two coats of aluminium paint over a coat of zinc chrome primer including dismantling of undersize / defected cross arms of M.S. channel or angle of any sections complete all as specified and directed.
Supply and fix in repair 200W LED High Bay Light fittings made of pressure die cast aluminium housing with integrated polycarbonate IP Lens cover, IP66 protection, cradle & eye bolt both arrangements should be provided for mounting with additional safety chain and system efficacy should be greater than 120 Lumen per watt. Driver should be BIS approved silicon filled potted driver with inbuilt 4KV surge protection device and 10 KV surge protection device in luminare. THD shall be <10%, Power Factor >0.95, CCT 5700K and brand name should be embossed / engraved on the LED fitting for traceability till life complete all as specified and directed. Note: - Contractor shall arrange ladder upto 30 meter height for fixing of light fittings without any extra cost.
Supply and fix in repair 1.1 KV straight through heat shrinkable joint kit suitable for 4 core XLPE armoured aluminium conductor cable of size 16 to 25 sqmm complete all as specified and as directed.
Supply and fix in repair cable junction box 155 x 210 x 92 mm in size, made out of thermoplastic sheet having IP 66 protection with integrated membranes / metric knockouts for cable entry size 10-16 sqmm for outdoor installation fixed / flushed on PCC foundation or GI pipe complete all as specified and directed.
Supply and fix in repair 8 KW, 3 Phase Nature Switch (using Infrared Sensor technology) based automatic street light timer switch for automatic switching on / off street light based on Lux level of nature light (required illuminance level for switching ON is ≤ 60 Lux and for switching off ≥ 10 lux). The sensor should also have part night operation facility of min. 4 hrs to max 12 hrs, consisting of sensor, overload protection fusegear, 3 Nos contactor, 3 Nos incoming MCBs & 3 Nos outgoing MCBs of 32-40 Amps 10 KA each and circuit wiring (Copper) of min 10 Sqmm terminal blocks for cable entry & control unit enclosed in pole / wall mounted enclosure made out of rust proof , Electric shock proof , termite proof thermoplastic polycarbonate enclosure (with hinged lid) conforming to IP-66 protection fixed to pole by using MS clamps fabricated out of 25mmx3mm thickness, Bolts and nuts as required at site complete all as specified and directed. Note - (i) Price shall inclusive of sensor, Contactor, Incoming- Outgoing MCBs, Enclosure etc. (ii) Nut bolts, clamp for fixing on poles/wall shall be included in the quoted rates. (iii) The Sensor must have the warranty of minimum of 2 years. (iv) The test certificate and warranty certificate must be provided by the contractor before releasing any payment.
Supply and fix in repair 10 W LED aviation light luminaires, IP-65 comprising of aluminium housing with red polycarbonate enclosure complete all as specified and directed. Make:- Bajaj Cat No BGAV302 or equivalent model of Philips / Crompton.
Materials and labour for taking down old unserviceable aviation light from its position and refixing after repair including fixing of nut bolts, welding of GI pipe complete all as specified and directed.
Supply and fix in repair 60 Watt LED gate light outdoor type made of pressure die cast aluminium housing suitable for retrofit LED lamps, IP-65 protection, of size 189x370 mm mounted on GI post and pillars of suitable size complete all as specified and directed. Note- Quoted rates shall be deemed included cost of GI post, PCC foundation and LED lamps.
Supply and fix in repair 07 Meter hieght galvanised octagonal pole with base plate standard bracket 1.0 meter length L-type with 70 degree, bolts & nuts with hot dip galvanised and suitable for wind velocity as per IS 875 part-3 including inbult three phase terminal block for loop in and loop out box having controlled with MCB with IP- 65 protection for utilisation of street light with all accessories complete all as specified and directed. Note:- (a) Excavation and earth work and PCC shall be measured and paid separately under respective items. (b) Cost of supply & fixing of bolts shall be included in the quoted rates.
Supply, install , testing and commissioning 3 phase neutral, 415 volts indoor type, wall mounted panel of size 1100 mm x 1100 mm x 250mm (CPRI approved) weather proof, made out of 2.00 mm thick CRCA sheet, detachable gland plate at top/bottom of 2mm thick CRCA sheet, with anticorresive coating and finally epoxy polyester powder coating with pure polyster simens grey structural RAL-7032 shade and duly grouted in wall with the help of cement screw/nuts & Bolts protection class IP66 fully compartmentalize design with 04 Nos of busbar made of copper ETP grade suitable for 300 Amp (size of copper strip should not be less than 25 x 6 mm for each phase and neutral) pre-wired with suitable size of copper strip / copper wire with colour code for connecting out going MCCB/ MCB's, including suitable aluminium earth strips conforming to IS with danger notice plate, necessary cable glands, cable connection with proper lugs, making electrical connection and circuit wiring after taking down old unserviceable indoor panel of any size. The Indoor panel shall be fixed with following accessories :- (A) Incoming: - (a) MCCB 200 Amp rating , 4 Pole , 415V, AC, 50 HZ, thermal release range amp with adjustable overload setting and short circuit setting, Ics-100% Icu, service breaking capacity 25 KA - 01 No.
Supply and fix in repair MCCB, 4 pole, 125 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic setting type complete all as specified and directed.
Supply and fix in repair MCCB, 4 pole, 100 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic setting type complete all as specified and directed.
Supply and fix in repair MCCB, 4 pole, 63 Amps, 415 Volts, breaking capacity 25 KA, adjustable thermal and magnetic setting type complete all as specified and directed.
BHATTACHERJEE CONSTRUCTION (BID ID -3474108)
SARKAR AND COM (BID ID -3474043)
VISHAL ENTERPRISE (BID ID -3474007)
KAZI ENTERPRISE (BID ID -3474360)
Das and Brothers (BID ID -3474088)
ROY CONSTRUCTION (BID ID -3474126)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.39 MB
Tenderdoc8667.pdf
Tender Documents • 1.23 MB
BOQ_824749.xls
BOQ • 0.81 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .