Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.8 LAccepted-AOC NEAR DOON INSTITUTE BHALLA FARM SHYAMPUR RISHIKESH DEHRADUN UK 249 204 | DEHRADUN | DEHRADUN | UTTARAKHAND | 249204 | L1 | Accepted-AOC BEING L1 | |
| 2 | L2₹52.4 L+₹1.7 L (3.34%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L2 | Rejected-Finance BEING L2 | |
| 3 | L3₹58.6 L+₹7.9 L (15.6%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance BEING L3 |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
9 Mar 2024, 6:00 pmClosed
GE AF BARODA
GE AF BARODA PO DARJIPURA BARODA 390022
REPAIRS / DAY TO DAY MAINT OF STANDBY DG SET / AMF PANEL / CONTROL PANEL / CABLES / DG SET EARTHING AND REPAIRS / MAINTENANCE OF LT CABLE / METER BOX / DBs / ENERGY METER / EARTHINGS AT DARJIPURA AT AF STN BARODA
2024_MES_642009_1
8882/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF BARODA
AS PER TENDER DOCUMENTS AND NIT
4 documents required · 4 mandatory
₹500
GE AF BARODA
₹94,000
Yes
27 Mar 2024
12 Feb 2024
16 Mar 2024
12 Feb 2024
9 Mar 2024
26 Feb 2024
13 Feb 2024 - 19 Feb 2024
Amount
Maintenance and servicing of 160 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Maintenance and servicing of 100 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Maintenance and servicing of 82.5 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Maintenance and servicing of 62.5 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Maintenance and servicing of 40 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Maintenance and servicing of 35 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Maintenance and servicing of 25 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Maintenance and servicing of 20 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF) and carrying out routine 'A' check of the engine complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Notes for items No 1.00 to 8.00:- (i) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings. (ii) Servicing of DG Set along with connected Alternator and AMF Panel Board including 'A' Check of the Engine shall be carried out once in every 15 days (Except during the month when 'B' check is carried out) as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs.( List DG as 20KVA-9Nos, 25KVA-2Nos, 35KVA-1Nos, 40 KVA-3Nos, 62.5KVA-1Nos, 82.5KVA-2Nos, 100KVA-2 Nos , 160 KVA-1 Nos)
(ii) Serviceaing of AMF panel shall included with cleaning of dust inside with blower, cleaning of moving part /contacts from CT cleaner, tightening of loose parts /electrical wires, cleaning of contractors, relays and junction points, servicing/ adjustment of relay, complete testing of AMF relay with necessary settings and load management system complete with replacement of worn out unserviceable components /burnt wires thimbles /lugs complete tested automatic start the DG set on mains fails in presence of MES rap. (iii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be included in the rate quoted for this item. (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) List of checks to be carried out under 'A' check is attached as Appendix 'A' to the Particular specifications.
14. SERVICE DONE ‘A’ CHECK As per items in Sch ‘A’ 14.1. Check Engine Oil Level 14.2. Check Oil Bath Cleaner Oil Level 14.3. Drain Sediment From Fuel Tanks 14.4. Clean Pre Cleaner Dust Pen 14.5. Check Air Cleaner Rostnction 14.6. Clean/Change Air Cleaner Element 14.7. Check Coolant Level 14.8. Record Oil Presure 14.9. Check Battery Voltage and Water Level and Apply Jelly on terminates. 14.10. Check and Tight all Bolts and Nuts of Engine and Altemator. 14.11. Check all AVM Pads 14.12. Check Throltle Linkage 14.13. Change Full Filter 14.14. Clean Fuel Tank Breather 14.15. Record RPM, Voltage, AMPS & H2 14.16. Record Oil Pressure. 14.17. Clean / Change Crank Case Breather
14.18. Check Air Piping 14.19. Clean Oil Both Air Cleaner Tray Screen 14.20. Change Water Filter 14.21. Check / Adjust Belts 14.22. Clean Oil Bath Air Cleaner 14.23. Check Fan Hub / Air Blower Hub and Water Pump 14.24. Clean and Calibrate Injector Replaca Fuel Pump Filter Screen and Magnet 14.25. Check Fuel Pump Calibration 14.26. Clean Turbocharger 14.27. Check Turbocharger Bearing Clearance 14.28. Tighten Manifold Nuts or Copscrews 14.29. Rebuild or Replace Water Pump 14.30. Replace Hose 14.31. Clean Electrical Connections 14.32. Check Safety Controls 14.33. Clean Cooling System / Rediator Assy. 14.34. Clean Engine and Alternator Assy. Note : If any addition requirement for ‘A’ Check as per directed by Engineer-in-Charge
Maintenance and servicing of 160 KVA DG set of any make Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF) and carrying out routine 'B' check of the engine including items covered in 'A' check complete for smooth functioning all as per manufacturer's instructions complete all as specified and directed
Description all as per items No 9.00 here-in-before but 100 KVA capacity complete all as specified and directed
Description all as per items No 9.00 here-in-before but 82.5 KVA capacity complete all as specified and directed
Description all as per items No 9.00 here-in-before but 62.5 KVA capacity complete all as specified and directed
Description all as per items No 9.00 here-in-before but 40 KVA capacity complete all as specified and directed
Description all as per items No 9.00 here-in-before but 35 KVA capacity complete all as specified and directed
Description all as per items No 9.00 here-in-before but 25 KVA capacity complete all as specified and directed
Description all as per items No 9.00 here-in-before but 20 KVA capacity complete all as specified and directed
Notes for items No 9.00 to 16.00:- (i) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exclusive of servicing/ maintenance of the above said fittings (ii) 'B' check shall be carried out once in every six months or 250 hours of running of DG Set whichever is earlier. Servicing of DG Set along with connected Alternator and Panel Board including items covered in 'A' Check of the Engine shall also be carried out in that month as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set for a period of 30 days from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs
(iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item,contractor to be provided fuel filter, oil filter, water filter,top head gaskets,fuel pipes, battery terminal, battery lead and distilled water. (v) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications.
15. SERVICE DONE ‘B’ CHECK As per items in Sch ‘A’ 15.1. Check Engine Oil Level 15.2. Check Oil Bath Cleaner Oil Level 15.3. Drain Sediment From Fuel Tanks 15.4. Clean Pre Cleaner Dust Pen 15.5. Check Air Cleaner Rostnction 15.6. Clean/Change Air Cleaner Element 15.7. Change Oil Bath Cleaner Oil 15.8. Check Coolant Level 15.9. Change Engine Oil 15.10. Change Engine Fuel Flow Oil Filter 15.11. Change By Pass Filter 15.12. Record Oil Presure 15.13. Check Battery Voltage and Water Level and Apply Jelly on terminates. 15.14. Check and Tight all Bilts and Nuts of Engine and Altemator. 15.15. Check all AVM Pads 15.16. Check Diaphragm Compling 15.17. Check Tappet Clearance 15.18. Repalce the Valve Door Gasket 15.19. Check Throltle Linkage 15.20. Change Full Filter 15.21. Clean Fuel Tank Breather 15.22. Check erehuft for leakage 15.23. Check Carbon brush & Commection in Alternator
15.24. Record RPM, Voltage, AMPS & H2 15.25. Record Oil Presure. 15.26. Clean / Change Crank Case Breather 15.27. Check Air Piping 15.28. Clean Oil Both Air Cleaner Tray Screen 15.29. Change Water Filter 15.30. Check / Adjust Belts 15.31. Adjust injectors and Valves 15.32. Clean Oil Bath Air Cleaner 15.33. Check Fan Hub / Air Blower Hub and Water Pump 15.34. Clean and Calibrate Injector Replaca Fuel Pump Filter Screen and Magnet 15.35. Check Fuel Pump Calibration 15.36. Clean Turbocharger 15.37. Check Turbocharger Bearing Clearance 15.38. Tighten Manifold Nuts or Copscrews 15.39. Rebuild or Replace Water Pump 15.40. Replace Hose 15.41. Clean Electrical Connections 15.42. Check Safety Controls 15.43. Clean Cooling System / Rediator Assy. 15.44. Clean Engine and Alternator Assy. Note : If any addition requirement for ‘B’ Check as per directed by Engineer-in-Charge
Repair / overhauling of following mentioned Self Starter assembly of DG Set by disconnecting and removing from the engine, cleaning of all accessories, replacing of worn out parts such as brushes, bushes, contact plates, jumping leads and seals, revarnishing the field coil, armature and re-assembling the same and re-fixing into the engine including testing all as per manufacturer's instructions complete all as specified and directed (a) Self starter assembly, 12 Volt DC 160 KVA
Description all as per item No 17.00 here-in-before but Self starter assembly, 12Volt DC up to 100 KVA complete all as specified and directed
Dismantling and taking out burnt or unserviceable Self starter 12 VDC from existing DG set and rewinding of Self starter 12 V DC motor with same gauge copper winding wire ISI mark including providing paper insulation varnishing drying complete to achive appropriate insulation resistence and refixing and testing complete all as specified and directed
Repair / overhauling/ Descaling of Radiator assembly 160 KVA capacity DG set by disconnecting and removing from the engine, dismantling the top and bottom chambers, descaling the sediments, scales, corrosion etc. by means of acid, cleaning and high pressure water washing, air cleaning, re-assembling the same with new gaskets including arresting leakages, if any and fixing to the engine with new hoses, clips etc. complete all as specified and directed. Note: The rate quoted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges.
Description all as per item No 20.00 here-in-before but Radiator assembly 100KVA/75 KVA/70 KVA/82.5 KVA/ 62.5 KVA/ 40 KVA capacity complete all as specified and directed
Supply only following filters of DG Set capacity 20 KVA to 62.5 KVA complete all as specified and directed
Air filter Primery
Lub Oil filter
Fuel filter
Supply only following filters of DG Set capacity 75 KVA- 82.5KVA complete all as specified and directed
Air Filter Primary
Air Filter Safety Inner
Fuel Water Separator
Oil Filter
Fuel Filter
Supply only following filters of DG Set capacity DG Set Capcity 100 KVA complete all as specified and directed
Air Filter Primary
Air Filter Safety Inner
Fuel Water Separator
Oil Filter
Fuel Filter
Supply only following filters of DG Set capacity of DG Set capacity 160KVA complete all as specified and directed
Air Filter outer
Air filter Inner
Fuel Water Separator
Oil Filter
Fuel Filter
Lub Oil filter
Supply only follwing items complete all as specified and directed :-
Battery terminal heavy duty of brass.
Distilled water (In 1 ltr bottel)
Coolant for radiator.
Engine oil SAE 20W-40W. Make : Servo/ Castrol/VOLVOLINE/ IOC/HP
Supply and fix in repairs fuel flexible pipe wire braded,1,1/4''to 3/8''PVC best quality.
Supply and fix in repair Oil pressure gauge complete.
Supply and fix in repair Oil pressure Switch complete.
Supply and fix in repair Water temperature gauge
Supply and fix in repair Ignition switch
Supply and fix in repair Indicating lamp
Supply and Fix in repairs solenoid switch, 240 volts, suitable for 160 KVA/83.5/75/70/62.2 KVA DG set complete all as specified and directed
Supply and Fix in repair solenoid switch, 240 volts, suitable for 10 to 50 KVA DG set complete all as specified and directed
S&F in repairs Automatic voltage regulator (AVR) Suitable for DG Set 160/100 KVA complete all as specified and directed
S&F in repairs Automatic voltage regulator (AVR) Suitable for DG Set 10 to 83 KVA complete all as specified and directed
Supply and fixing in repairs automatic Battery charger suitable for AMF Panels mounted capacity 12 volt 10 Amps of suitable for charging the battery up 180 AH capacity, input votage 230V complete all as specified and directed Make :ELNIX/Syspro/
Supply and fix in repairs fan belt as per existing make for the following capacities of DG sets complete all as specified and directed (a) 160 KVA/125/100 KVA/82.5kva
Description all as per item No 38.00 here-in-before but for 20 to 63 KVA complete all as specified and directed
Supply and Fix in repair Lead acid battery, 12 volt, 150 AH complete all as specified and directed
Supply and Fix in repair Lead acid battery, 12 volt, 100 AH complete all as specified and directed
Overhauling the fuel injection pump assembly and injectors, disconnecting the fuel supply lines, and taking out Fuel Injection Pump (FIP) to workshop for servicing/repair, replacement the worn out/un serviceable parts like service kit, D-Valve, Elements, nozzles etc., as required and calibrating the same, assembling at site and testing on load complete all as specified and directed for the following capacity of Gen sets:- (a) 160 KVA
Description all as per item No 42.00 here-in-before but for 100 to 125 KVA
Description all as per item No 42.00 here-in-before but for 70 to 83 KVA
Description all as per item No 42.00 here-in-before but for 64.5 /63 KVA
Description all as per item No 42.00 here-in-before but for 40 KVA
Description all as per item No 42.00 here-in-before but for 25 to 30 KVA
Description all as per item No 42.00 here-in-before but for 20 KVA
Disconnecting the inlet and outlet supply of the fuel tank cleaning the tank internally by draining out the fuel into clean container, taking out the corroded sludge and foreign impurities, cleaning with pressure water and air, drying the tank, preparing the external old painted surface of tank including steel platform /stand of fuel tank and painting the prepared surface with one coat of synthetic enamel paint of existing shade, including writing SM /MES No & date of cleaning of fuel tank complete all as specified and directed for the following capacity of Gen sets :- 160 KVA DG set Diesel Generator Sets including connected Alternator, Panel Board (AMF/ Non AMF)
Description all as per item No 49.00 here-in-before but for for 100 KVA .
Description all as per item No 49.00 here-in-before but for 82.5 KVA .
Description all as per item No 49.00 here-in-before but for 62.5 /63 KVA .
Description all as per item No 49.00 here-in-before but for 40 KVA .
Description all as per item No 49.00 here-in-before but for 25 to 30 KVA .
Description all as per item No 49.00 here-in-before but for 20 KVA .
M&L for repairs in Right / Left hand lock with catcher for acoustic enclosure (canopy) of any capacity DG sets all as specified & directed.
M&L in repairs for Dial type mechanical fuel level indicator for any capacity DG set complete all as specified & directed.
Labour only for attending emergancy complaint of the DG set with AMF Panel complaints carried out by manufacture's authorised mechanic from the servicing centre without any delay with rectified the defects by carefuly opening and check the DG set parts which defects find out at site and replace the defected parts from the DG Set for smooth functioning complete all as specified and directed Note:- Supply and replacement item shall paid and measured separately.
S&F in repairs 4 Pole, 32 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 03 and cat no.CS97011) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 63 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 12 and cat no.CS97014) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 95/100 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 22 and cat no.CS97017) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 125/130 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 23 and cat no.CS970118) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 160 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 32 and cat no.CS97020) or equivalent of make siemens/ABB
S&F in repairs 4 Pole, 200 Amp power contactor, AC 3 rating,415 V and Conforms to IS / IEC 60947-4-1 & IEC 60947-4-1 fixed in existing panel & connecting complete all as specified & directed Make:- L&T (Type MCX 33 and cat no.CS97021) or equivalent of make siemens/ABB
S&F in repairs MCCB 250 Amps, 4 pole, breaking capacity 35/36 kA with thermal Magnetic release range 200 Amps to 250 Amps, fixed in existing panel & connecting complete all as specified & directed
S&F in repairs MCCB 160 Amps, 4 pole, breaking capacity 25 kA, with thermal Magnetic release adjustable type fixed in existing panel & connecting complete all as specified & directed
S&F in repairs MCCB 100 Amps, 4 pole, breaking capacity 25 kA, with thermal Magnetic release adujustable type fixed in existing panel & connecting complete all as specified & directed
S&F in repairs indicating lamp LED type, size 22.5 mm voltage 240 V AC. fixing in existing AMF panel & connecting complete all as specified & directed Make:- BCH / C&S / Havells / Simens / L&T
S&F in repairs push button with element for PB1 - Engine start / PB2 - Engine stop / PB3 - DG contactor ON / PB4 - DG contactor OFF / PB5 - Mains contactor ON / PB6 - Mains contactor OFF, fixing in existing AMF panel & connecting complete all as specified & directed Make:- BCH / C&S / Havells / Simens / L&T
S&F in repairs Aux control relay with socket 3 C/O 12 V DC, 5 A fixing in existing AMF panel & connecting complete all as specified & directed . Make:- BCH / C&S / Havells / Simens / L&T
S&F in repairs amps meter digital type 0-400 Amps of size 96 mm x 96 mm, fixing in existing AMF panel & connecting complete all as specified & directed .
S&F in repair C T ratio 150 A/5A Class of accuracy 1, VA 15, ring type fixing in existing AMF panel & connecting complete all as specified & directed.
S&F in repair C T ratio 250A/5A Class of accuracy 1, VA 15, ring type fixing in existing AMF panel & connecting complete all as specified & directed by Engr-in-Charge.
S&F in repair C T ratio 50A/5A Class of accuracy 1, VA 15, ring type fixing in existing AMF panel & connecting complete all as specified & directed .
S&F in repairs Digital type DC Voltmeter, 0 to 30 V DC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed
S&F in repairs Digital type DC Ammeter, 0 to 20 ADC, size 96 mm x 96 mm fixing in existing AMF panel & connecting complete all as specified & directed by Engr -in-Charge
Supply and fix in repairs MCB’s single pole 6-32 Amps, 415 volts with ‘C’ curve, fixing in existing AMF panel & connecting complete all as specified & directed .
Supply and fix in repairs Aux supply 12 V DC, voltage sensing relay 415 V AC fixing in existing AMF panel & connecting complete all as specified & directed . Make:- BCH / C&S / Havells / Simens / L&T
S & F in repair electronic controller for AMF panel of capacity 20 to 62.5 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel complete all as specified and directed
S & F in repair electronic controller for AMF panel of capacity Controller for 82.5 KVA TO 200 KVA DG sets showing the complete details to run the DG sets and to stop the DG sets complete with logical programming as per existing AMF panel complete all as specified and directed
Dismantling of alternator assembly complete from DG set of capacity from 20 KVA/30KVA/40KVA and removing the burnt out copper winding cleaning of limb thoroughly and rewinding the same with supper enameled copper winding wire of the same gauge and turn with proper class of insulation impregnated & baking, assembling and testing complete all as specified and directed
M & L for rewinding of DG set alternator of 50 KVA -82.5 KVA capactity with existing size and gauge and adequate number of turns of super enamelled copper winding wire and bore conductor including varnishing insulating material drying baking heating and connection leads with thimble and making connection complete all as specified and directed
Supply and installation, testing, commissioning, factory made, outdoor type, AMF Panel board, suitable for 82.5 KVA DG set confirming to IS-5039, cubical type base mounting with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 Hz supply mounted on and including MS angle section 40 x 40 x 5 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN bus bar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete including taking down old AMF panel , Controller with battery charger 12 V,15 A all as specified and directed & Consisting of the following equipment connecting up incoming and out going cables complete with glands and lugs and chamber painted with two coats of aluminium paint over a coat of red oxide primer including mounting the chamber with suitable size of bolts/ nuts including taking down existing unserviceable chamber of any description all as specified and as directed.
(l) Miniature circuit breaker , 1 pole 6 Amps with over load & short circuit protection , short circuit strength 10 kA - 06 Nos. (m) Miniature circuit breaker , 1 pole 10 /16 Amps with over load & short circuit protection , short circuit strength 10 KA. - 02 Nos (n) Neutral link rated current 15 A -01 No (o) Aux supply 12 V DC , voltage sensing relay 415 VAC. - 02 Nos Note :- (a) Quoted rate includes excavation, earth work and PCC work and connection & testing complete.(b) PCC 1:3:6 platform with angle iron frame for mounting AMF panel 1.2m above ground level, all as directed by Engineer in Charge. (c) AMF Panel should be mounted on platform of PCC (1:3:6) and supported by Angle sections complete all as directed by Engg-in- Charge.
Supply and fix in Replacement of following spare parts in maintanance carried out in existing AMF panels complete all as specified and directed
Supply failure timer
Restoration timer
Diod 25 Amp thread type
Axillary contactor 3 phase suitable for AMF Panel
NC/NO relay complete
Under voltage relay
Time Delay relay
HRC fuse up 63 A to 250 A any type for backup/ short circuit protecton
M&L in replacement for on load changeover switch of capacity including sheet enclosure and removing old changeover switch any type and necessary fixing on wall/in LT panel complete all as specified and directed Make:Havells, C&S, L&T or equivalent make approved by GE.
Repair, Maintenance and painting of existing canopy of eco friendly DG Set , cleaning of internal & external parts, tightening of loose parts, lubricating checking of unserviceable Door locks and keys, replacing of damaged or burned inside sponge insulations, removing existing old rusted paint on outer porting of DG set canopy preparation of surface by using grinder, cleaning all rusted old surface properly apply primer putty on raugh surface of canopy and finished all raugh surface properly and necessary spary painting with two coatof super enamelled paint of same colour of company pattern on inside and out side of canopy chamber apply to match with existing colour good finish to intire satisfaction of engr-in-Charge of following capacity complete all as specified and directed. Note:- Door lock shall be measured and paid separately
100 KVA /160KVA
Material and labour for providing wooden plank for battery of DG Sets complete all as specified and directed.
Material and labour for shifting of DG set of any Capacity from old platform to new platform including provision of crane for lifting DG set including making new connection for AMF Panel to existing main panel complete all as specified and directed
Material and labour for reparing and painting of of LT/AMF panel door including replacement door handel, hinges, nut bolt, welding work completeincluding removing existing old rusted paint on outer porting of AMF panel preparation of surface by using grinder, cleaning all rusted old surface properly apply primer putty on raugh surface of panel and finished all raugh surface properly and necessary spary painting with two coat of super enamelled paint of approved colour by Engr-in-Charge for inside and out side of panel intire satisfaction of Engr-in-Charge complete all as specified and directed
Rerouting LT cable of any size 10 Mtr from existing layout including excavation and returning filling but excluding of sand cushinning and cable cover protection complete all as specified and directed
Supply, laying, testing and comminssioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 120 sqmm 3.5 core complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately under respective item of BOQ.
Supply, laying, testing and comminssioning of cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as specified and directed. Note: Excavation and earth work shall be measured and paid separately under respective item of BOQ.
Supply, laying, testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 4 core 25 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed Note: Excavation and earth work shall be measured and paid separately under respective item of BOQ.
Supply, laying, testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 4 core 35 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed Note: Excavation and earth work shall be measured and paid separately under respective item of BOQ.
Supply, laying, testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 4 core 50 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed Note: Excavation and earth work shall be measured and paid separately under respective item of BOQ.
Excavation in trenches not exceeding 1.5 metres wide and not exceeding 1.5 metres in depth for foundation or laying/taking out existing pipe etc and getting out in soft/loose soil complete all as specified and as directed
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in any type of soil complete all as specified and as directed.
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
M&L for sand cushioning to LT cable with using clean dry and natural river sand gently punning below/ around cable complete all as specified and directed.
M&L for well burnt bricks sub class 'B' as in protection of cable laid dry, flat abutting each other width wise complete all as specified and directed.
Providing necessary connection to run AMF panel only in night time of parimeter light by provding 230VAC 200W invertor and time switch including necessary control wiring modification and testing complete all as specified and directed
Supply only DC to AC Converter Inverter 200 W capacity input voltage 12 V output volatge 220V AC complete all as specified and directed. Make Microtech/Excide
Supply only Daily Weekly Programmable Electronic 110 240 VAC Crono Timer Switch, 50/60 Hz, 1 C/O SPDT Make Gic L&T Cat. No. : 67DDT0 (Black) or equivelent in make Selec TS1W1 complete all as specified and directed
Material and Labour for cleaning and removing of vegetation, bushes, surface dressing up depth not less than 10cm to remove the vegitation up to root surrounding the AMF panel and DG set plateform all around Approx 25-30 Sqmtr area complete including providing lock complete all as specified and directed Note :- The cleaning vegitation required quaterly, cleaning of each Quater measured one job for a installation.
Material and Labour for cleaning and removing of vegetation, surface dressing surrounding AMF panel the panel, welding of damaged panel doors, fixing of hinges, providing locking arrangements, applying one coat of primer, painting of panel with two coats synthetic enamel paint of existing colour complete including providing lock complete all as specified and directed
M&L for taking out fuel tank from 200 KVA DG Set, welding / brazing at all leakage joint to make leak proof & reinstalled complete all as specified and directed
Material and labour for making DG set platform suitable DG set up to 40 KVA size 4 mtr x 3 Mtr and Height 0.5 Mtr from ground level GL including excavation in trenches not less than 1 mtr, PCC 1:5:10 type E2 for foundation, brick work in cm 1:6, PCC 1:2:4 type B1 in copping, plaster 10mm thick in cm 1:6 om brick /complete surface PCC 1:4:8 type B1 sub base 75mm thick, as in flour RCC 1:2:4 type B1 100mm thick floor with 10mm dia bar using extra cement returning filling and removal on surplus soil, 3 coats of white washing on cement work for fixing transformer including ramp of suitable size mounting of transformer complete all as specified and as directed.
Dismantling of broken transperent acrylic sheet of metering section of DG Canopy door and Supply and fixing of new acrylic sheet of 3mm thick transperent along with rubber seal and making water proof the door complete all as specified and directed
Checking/testing of Earth resistance value of earthing pits Installed inside Darjipura, Makarpura, harni camp and hari airfield area as requirement basis as directed by Engr in Charge or as schedule and making the damaged earthing serviceable by pouring salted water into earthing or making continuity by GI strips and bringing down the resistance value within specified limits. including maintenance of existing earthing by cleaning the earth chamber funnel and cleaning of vagetation surrouding earthing pit up to 2 mtr complete all as specified and directed
Note: (i) The contrcator will deploy a team for eacheach DG set at darjipura to test the resistance value of earthings in each zone to complete the process within one month. The entire process will be repeated after every six months (half yearly) upto completion of the contract. (ii) one earthing testing in one season is measured one job. (iii) Digital Earth tester will be arrenge by the contractor his own. (iv) Date of testing and due date of testing is to be written on a register with sign of user rep & Engr-in Charge . (iv) Testing and correction action is to be done within one month from date of commencement . earthings is to be completed within one month. Thereafter on half yearly basis or as directed byEngr-in charge and same is to be completed within one month.The contractor has to deploy electrician with helper and testing equipment and all the resources to complete the task within one month. (v) If any material required for improvement of resistence value which value is more than their permissible limit will be measured and paid seperately.
M&L for providing earthing complete with galvanised steel earth plate electrode 60 x 60cm x 6mm thick buried directly in ground (Earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to galvanised earth lead 32x6mm GI strip upto 7.5 meter long by means of bolts,nuts check nuts and washers of all galvanised iron or steel providing alternate layer of charcoal dust and salt providing alternate layer of charcoal and salt providing alternate layer of charcoal and salt providing alternate layer of charcoal and salt all as shown in electrical plate No.3 of SSR Part-1 and connected to test point including necessary excavation/ earth work in any type of soil/rock strata, PCC 1:3:6 type C1 cement concrete 1:2:4 type B1 reinforced with welded steel wire fabric (AMP) not less than 4 KG per Sqm funnel with wire mesh and watering pipe 20 mm dia bore (medium grade), PCC pit with 50mm thick PCC cover etc. including testing on completing including GI protection pipe 40mm dia medium grade for earthing lead complete all as specified and directed including demolition of old unservicable earthing. Note : Earth strip and protection pipe up 7.5 Mtr is demmed to be included with unit rate of item
Supply only epoxy earth strip insulator size 32mmx6mm including bas base screw complete all as specified and directed
S&F with replacement of GI strip 32 x 6 mm buried in ground after testing point complete all as specified and directed
S & F meter box panel indoor type wall mounted suitable for fixing of 06 Nos of 1 Ph metering unit made out of CRCA sheet 2mm thick of powder coated incl power wiring with minimum 10 sqmm PVC insulated FRLS multi stranded copper conductor and tranferent taughen glass of suitable size with following accessories complete all as specified and directed :- a) MCCB 100 Amp 4 pole 16 KA -01 Nos (As incommer) b) Copper busbar of 300 Amp suitable for 4 wire system mounted on rubber insulators (Outgoing) (c) MCB 63 Amp SPN -08 Nos (d) MCB SPN 10 Amp-01 Nos (for Staircase) (e) Seperate compartment for 4 Nos metering units
Supplying and fixing smart three phase four wire energy meter BIS 16444 : 2015 Reaffirmed 2020) marked in existing meter board/ floor panels having current range 10-60 Amp, 415 Volts, accuracy class 1.0 complete all as specified and directed
Supplying and fixing smart single phase four wire energy meter BIS 16444 2015 (Reaffirmed 2020) marked in existing meter board/ floor panels having current range 10-60 Amp, 240 Volts, accuracy class 1.0 complete all as specified and directed
Supply, install, testing and commissioning of factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door typesize not less then size 1500 W x 1500H x 500 D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on percelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder piller.The complete feeder pillar box should be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of complete all as specified and directed :- (Location :- Near Qtrs No 269 , 280 , 240, 246,293, 288, 260 and 263.
Incomer:- (a) MCCB FP 200 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no (b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Supplying and laying Supplying and laying unreinforced precast concrete cable cover, Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed
Taking out existing unserviceable LT cable any size complete all as specified and directed
Taking out existing U/S panel from existing site including disconnecting of existing cable complete all as specified and directed
Supply, fixing, testing and commissioning of feeder pillar box outdoor made out of CRCA sheet not less than 3.15mm thick duly powder coated, CPRI approved 300 Amp rating Aluminium Busbar box size not less than 1 Mtr x1 mtr x .4Mtr suitable for arrengement of following complete all as specified and directed : (a) Incommer :MCCB 100 16 KA 4 pole - 2 Nos (loop in /Loop Out) (b) Out going: MCB SPN 32 Amp - 6 Nos (c) 15 Amp switch socket combination- 6 Nos
M&L for Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as GI wire of 4 mm dia size by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation&earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra.
Badri Electricals
M/s Jagdish Machinery Stores
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .