| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹44.3 LAccepted-AOC 159 RANBIRPURA TEH DRASS DISTT KARGIL PIN 194102 | KARGIL | LADAKH | 194102 | ₹44.3 L Quoted ₹44.4 L | L1 | Accepted-AOC L1 |
| 2 | L2₹44.8 LRejected-Finance SAIDAKADAL SRINAGAR KASHMIR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹44.8 L | L2 | Rejected-Finance L2 |
| 3 | L3₹45.0 LRejected-Finance | ₹45.0 L | L3 | Rejected-Finance L3 |
| 4 | L4₹47.9 LRejected-Finance BIAMATHANG BAROO KARGIL J K | KARGIL | KARGIL | J K | ₹47.9 L | L4 | Rejected-Finance L4 |
| 5 | L5₹51.5 LRejected-Finance | ₹51.5 L | L5 | Rejected-Finance L5 |
| Sl No | Description | Qty | Unit | M/S MOHD KHAN L4 | M/S SUN RISE BUILDERS L2 | M/S MOHD FAROOQ L1 | M/S M A ENTERPRISES L5 | M/S TAMCHOS GURMATH L3 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc in hard/dense soil | 35.64 | Cum | 550 ₹19,602 | 510 ₹18,176.40 | 500 ₹17,820 | 700 ₹24,948 | 520 ₹18,532.80 |
| 2.00 | Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil all as directed. | 20.44 | Cum | 200 ₹4,088 | 150 ₹3,066 | 140 ₹2,861.60 | 400 ₹8,176 | 160 ₹3,270.40 |
| 3.00 | Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed. | 15.2 | Cum | 200 ₹3,040 | 160 ₹2,432 | 150 ₹2,280 | 400 ₹6,080 | 180 ₹2,736 |
| 4.00 | M&L for sand cushioning to UG cable laid in trenches all as specified and directed. | 10.69 | Cum | 1,250 ₹13,365 | 1,210 ₹12,937.32 | 1,200 ₹12,830.40 | 1,600 ₹17,107.20 | 1,250 ₹13,365 |
| 5.00 | M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site. | 880 | Each | 50 ₹44,000 | 50 ₹44,000 | 45 ₹39,600 | 200 ₹1.8 L | 60 ₹52,800 |
| 6.00 | Supply and fix in repair GI Pipe Light grade with all connected accessories of sizes 40 mm dia completed as directed for cable protection | 18 | RM | 520 ₹9,360 | 495 ₹8,910 | 490 ₹8,820 | 800 ₹14,400 | 500 ₹9,000 |
| 7.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core | 40 | RM | 350 ₹14,000 | 335 ₹13,400 | 330 ₹13,200 | 500 ₹20,000 | 340 ₹13,600 |
| 8.00 | Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core | 180 | RM | 350 ₹63,000 | 515 ₹92,700 | 500 ₹90,000 | 500 ₹90,000 | 520 ₹93,600 |
| 9.00 | Supply and fix HDPE (High density Polyethylene) flexible pipes ISI marked SDR 7.4 (PN16) of 50 mm bore confirming to IS code 4984:2026 for water supply incl assessories laid in surface /wall/ floor complete all as spd and directed. Make -Supreme Cat part PHK8T050300K , SFMC or equivalent | 450 | RM | 350 ₹1.6 L | 315 ₹1.4 L | 300 ₹1.4 L | 500 ₹2.3 L | 320 ₹1.4 L |
| 10.00 | Supply and fix 3- layer PP-R Polypropylene random copolymer) ISI markd Confirming to IS code-15801 concealed pipes SDR 7.4 (PN16) of 50 mm bore UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/ wall/ floor complete all as spd and directed.Note :- All connceted fittings like elbow,tee,reducer coupler will be count in RM | 250 | RM | 450 ₹1.1 L | 410 ₹1.0 L | 400 ₹1 L | 600 ₹1.5 L | 420 ₹1.1 L |
Updated dates
Tender Value
Refer Docs
EMD Value
₹83,000
Closing Date
3 Nov 2025, 9:00 amClosed
GE Khumbathang
Khumbathang
GE/KHU-69/2025-26 PROVN OF WATER SUPPLY AT BATALIK IN THE AOR OF AGE B/R-II KHALTSI UNDER GE KHUMBATHANG
2025_MES_729891_2
GE/KHU-69/2025-26
Open Tender
Support/Maintenance Service
180 days
GE Khumbathang
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE khumbathang
₹83,000
22 Dec 2025
16 Oct 2025
4 Nov 2025
16 Oct 2025
3 Nov 2025
21 Oct 2025
17 Oct 2025 - 20 Oct 2025
Amount
Excavation in trenches not exc 1.5 m wide and not exc 1.5 m in depth and getting it out for laying of cable / pole etc in hard/dense soil
Returning, filling in, including spreading, leveling watering, and well ramming in layers not exc 25 cm in hard/dense soil all as directed.
Removing excavated material n.exc 50m and depositing where directed at a level exc. 1.5 cm above the starting point all as directed.
M&L for sand cushioning to UG cable laid in trenches all as specified and directed.
M & L for providing PCC cable cover class LV type-I of size 250x150x40mm laid in perpendicular to the cable abutting each other all as specified and directed at site.
Supply and fix in repair GI Pipe Light grade with all connected accessories of sizes 40 mm dia completed as directed for cable protection
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3.5 core
Supply and fix HDPE (High density Polyethylene) flexible pipes ISI marked SDR 7.4 (PN16) of 50 mm bore confirming to IS code 4984:2026 for water supply incl assessories laid in surface /wall/ floor complete all as spd and directed. Make -Supreme Cat part PHK8T050300K , SFMC or equivalent
Supply and fix 3- layer PP-R Polypropylene random copolymer) ISI markd Confirming to IS code-15801 concealed pipes SDR 7.4 (PN16) of 50 mm bore UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches/ wall/ floor complete all as spd and directed.Note :- All connceted fittings like elbow,tee,reducer coupler will be count in RM
All as per item No. 2 above but size of pipe 40 mm bore complete all as spd and directed.Note :- All connceted fittings like elbow,tee,reducer coupler will be count in RM
All as per item No. 2 above but size of pipe 25 mm bore complete all as spd and directed.Note :- All connceted fittings like elbow,tee,reducer coupler will be count in RM
All as per item No. 2 above but size of pipe 20 mm bore complete all as spd and directed.Note :- All connceted fittings like elbow,tee,reducer coupler will be count in RM
Supply and fix Valves, Non Return Valve, flanged of class 1.6 PN,65mm (2.5") dia
Supply and fix Valves, Sluice, flanged of class 1.6 PN, 65 mm (2.5") dia
Supply and fix Foot valve confirming IS 4038 80 mm (3") dia
Supply and fix Stainer Y type confirming IS 4038 80 mm (3") dia
Supply and Fixing pipe galvanised Medium class including fitting 80 mm ( 3") dia
Supply and Fixing pipe galvanised Medium class including fitting 63mm ( 2.5") dia
Supply, Install, lowering, testing, and commissioning of horizontal multi-stage centrifugal pump , electric driven,minimum discharge of 170 LPM at 90 mtr head motor capacity minimum 10 HP complete all specified and directed.(One main + one standby) Make- Kirloskar RKB 65-19 E/L ,CRI pumps model HMW-12-25 or equivalent
Supply, Install, lowering, testing, and commissioning of horizontal multi-stage centrifugal pump , electric driven,minimum discharge of 170 LPM at 185 mtr head motor capacity minimum 15 HP complete all specified and directed.(One main + one standby) Make- Make- Kirloskar RKB 65-19 E/L ,CRI pumps model HMW-12-25 or equivalent
Supply and fix automatic Star delta starter for 10 HP motor with overload relay of range 9-12 Amps , power contractors ML-1 and suitable capacity timer range , single phase preventer including taking down old un-serviceable star delta starter complete all as specified and directed. Make- BCH/L&T/Havells or equivalent as approved by GE.
Supply and fix automatic Star delta starter for 15 HP motor with overload relay of range 20-16 Amps , power contractors ML-1 and suitable capacity timer range , single phase preventer including taking down old un-serviceable star delta starter complete all as specified and directed. Make- BCH/L&T/Havells or equivalent as approved by GE.
M&L for PCC Block masonry valve pit of size 150x150x160 c.m (internal dimensions of chamber) built in CM 1:6 including 10mm thick plastering internally with cement mortar 1:6 and flush pointing externally as the work proceeds in same mortar complete with 5 mm thick MS sheet cover with angle iron 40 x 40 x 6mm frame, handle , locking arrangement and painting steel surface (cover inside and outside with frame) with two coats of synthetic enamel paint over a coat of red oxide primer including emebding angle in PCC complete.
Supply and fixing PPR gate valves( Brass insert) of 25 mm dia
Supply and fixing PPR gate valves( Brass insert) of 20 mm dia
Supply and fix stop/ Gate Valves of 40 mm bore..
Supply and fix stop/ Gate Valves of 50 mm bore..
Supply and fixing insulation on tubing of for 65/50/40 mm dia pipe and 13mm thick of nitrile rubber complete all as specified and directed.
Supply and fixing insulation on tubing of for 25/20mm dia pipe and 13mm thick of nitrile rubber complete all as specified and directed.
Supply and fixing Aluminium Cladding of 28SWG thickness on insulated pipe having 65/50/40 mm dia and 13mm thick nitrile rubber tube complete all as specified and directed.
Supply and fixing Aluminium Cladding of 28SWG thickness on insulated pipe having 25/20 mm dia and 13mm thick nitrile rubber tube complete all as specified and directed.
Material and labour for PCC (1:3:6) C-2 using 40mm graded aggergate pedestal for supporting upto the base of main raisng pipe line complete all as specified and directed.
Material and labour for Bands,straps,supportsorstays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Earthing complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6mm as earthing lead buried directly in ground vertically to a depth not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 Mtr below normal ground level connected to and including galvanised iron strip 32X6 mm as earthing lead by means of bolts, nuts, check nuts & washers etc made of GI and connected to earthing test point all as shown in electrical plate No. 3 of SSR Part I of 2009.00 & as specified or indicated and testing on completion including exaction/earth work in any type of strata PCC ( 1:3:6 ) type C1 earthing chamber, pre cast slab 50 mm thick in cement concrete ( 1: 2 : 4 ) type B 1 ( reinforced with welded steel wire fabric (XPM) weight not less than 4 Kg / Sqm), funnel with wire mesh, I watering pipe of 20 mm bore medium grade and lugs, including galvanised iron strip 32X6 mm with GI protection pipe of 40 mm medium grade 7.5 meter long, etc complete all as specified.
Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (DG Set Panel No.1 ) INCOMING: (I) 4 pole MCCB 63 Amps with rupuring capacity 25 KA ,- 01 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 100 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves- 01 No.. OUTGOING (i) 4 pole MCCB 63 Amps with rupuring capacity 25 KA - 02 No (For Submersible Pump, spare) (ii) 4 pole MCCB 40 Amps with rupuring capacity 25 KA - 01 No (iii) Changeover 63 Amps - 01 (iv) RYB indication lamp -01 No. (v) Voltmeter digital type with range 0-500 Volts -01 No. (vi) Ammeter digital type with range 0-100 Amp .
Supply, installation, testing and commissioning LT panel of suitable size as per IE rule and latest IS, factory made dust and vermin proof outdoor type made out of 3.15 mm thick CRCA sheet including seperate compartment for each MCCB & for cable and busbar, mounted on frame of MS angle iron 40mmx40mmx6 mm with front and back openable door with lock & Key including necessary grouting and double coat powder coated of grey colour painting complete with following accessories.The degree of protection of panel shall be IP-54 including foundation all as specified and directed.:- (Panel No.2 ) INCOMING: (I) 4 pole MCCB 40 Amps with rupuring capacity 25 KA ,- 01 No (ii) Aluminium bus bar 3 phase 4 strip suitable for 60 Amps current carrying capacity complete with post insulators and heat shrinkable sleeves- 01 No.. OUTGOING (i) 4 pole MCCB 40 Amps with rupuring capacity 35 KA - 02 No (For centrifugal Pump, spare) (ii) 4 pole MCCB 32 Amps with rupuring capacity 35 KA - 01 No (For Submersible Pump ) (iii) Changeover 40 Amps - 01 (iv) RYB indication lamp -01 No. (v) Voltmeter digital type with range 0-500 Volts -01 No. (vi) Ammeter digital type with range 0-100 Amp .
Deduct Credit for Demolished/Dismantled material Rs (-) 0.00 (Minus) as listed in Schedule 'A' Part-II (Credit Schedule) Note : Tenderers will not quote against this item being a tentative amount, to be considered to arrive at the 'Contract Sum'.
M/S SUN RISE BUILDERS (BID ID -3459810)
M/S TAMCHOS GURMATH (BID ID -3459826)
M/S MOHD KHAN (BID ID -3460055)
M/S M A ENTERPRISES (BID ID -3460050)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.76 MB
Tender69.pdf
Tender Documents • 1.50 MB
BOQ_823613.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid