Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 LAccepted-AOC 6 573D BHASKARA BUILDING NADAKKAVU P O UDAYAMPEROOR ERNAKULAM KERALA 682307 | ERNAKULAM | KERALA | 682307 | L1 | Accepted-AOC L1 |
Tender Value
₹1.5 L
EMD Value
₹3,800
Closing Date
1 Jul 2024, 5:00 pmClosed
Registrar KFRI
Registrar KFRI Peechi
Electrical installation of bamboo processing machine and related work at project site,Venmony,Idukki District.
2024_KCSTE_675904_1
KFRI/232/2024 TO ELECTRICAL
Open Tender
Electrical Works
Item Rate
30 days
Venmony, IDUKKI
Please refer Tender documents.
5 documents required · 5 mandatory
₹590
Yes
₹3,800
Yes
26 Sept 2024
18 Jun 2024
3 Jul 2024
18 Jun 2024
1 Jul 2024
18 Jun 2024
Amount
DSR 2022(1.10.2)Wiring for light point/fan point/exhaust fan point/ call bell point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable in surface/recessed medium class PVC conduit , with modular switch, modular plate , suitable GI box and earthing the point with 1.5 sq. mm. FRLS PVC insulated copper conducter single core cable etc. are required.
DSR1.25.Supply and fixing two module stepped type electronic fan regulater on the existing modular plate & switch box including connection but excluding modular plate etc as required
Supplying and drawing following sizes of FRLS PVC insulated copper coductor, single core cable in the existing surface/recesed PVC conduit as required
DSR 1.17.12 3X2.5 sq. mm
DSR 1.17.13 4X2.5 sq.mm
DSR 1.17.14 5X2.5 sq.mm
DSR 1.17.22 4X4 sq. mm
DSR 1.17.21 3X4 sq. mm
DSR1.17.3 3X1.5 sq mm
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
DSR 1.21.1 20 mm
DSR 1.21.2 25 mm
DSR1.32 Supplying and fixing suitable size GI box with modular plate and cover in front on recess including providing and fixing 6 pin5/6 A 15/16 A modular switch and 15/16 A modular socket, connection etc. as required.
Supplying and fixing following way SP&N sheet steel MCB distribution board 240 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
DSR 2.3.1 16 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR 2.10.1 Single pole
DSR 2.10.3 double pole
DSR 2.10.4 Triple pole
DSR 2.10.5 Triple pole and Neutral
Supply nd fixing sheet steel TP MCB enclosure
DSR 2.11 Supply and fixing single pole blanking plate in the existing MCB DB complete etc. as required
DSR 2.14.2 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
DSR 2.15.2 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 30 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supply, conveyance installation testing and commissioning of LED tube light(4 ft) along with driver system wattage mzximum of 20W lumen out put of lamp greater than 1500 lumens, power factor >0.9 rated life of hours 15000 hr,system efficiancy 75 lumen/watt including aii necessary accessories as required complete.
20W LED light fittings
DSR 19.1 Supply,Installation,testing and commissioning of 1200 mm sweep BEE 5 star rated, ceiling fan with Brush less direct current(BLDC) motor, class of insulation B,3 no. blades,30 cm long down road,2 nos. canopies,shakle kit, safety rop,copper winding,power factor nt less than .9, service value(CM/M/W)6.00,air delivery minimum 210 CUm/Min,350 RPM(tolerance as per IS:374-2019), THD less than 10%,remote or electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temerature rise+75 degree C(max), Insulation resistance <2Mohm ,suitable for 230 V,50 HZ,single phase supply,earthing etc. complete as required.
1200 mm sweep -
Supplying and fixing modular blanking plate on existing modular plate and switch board excluding modular plate as required
Supplying and fixing following way horisontal type three pole and neutral, sheet steel MCB distribution board 415 volts on surface/ recess complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/ RCCB/ Isolator)
DSR 2.4.3 8way(4+24),Double Door
DSR 5.3 Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps, GI funnel with weld mesh, filling required quantity of charcoal including construction of inspection chamber with a bed concrete of 1:4:8 PCC using 40 mm broken stone (10 cm thick), brick work in cement mortar 1:6, plastering the surface of brick masonry and the exposed surface of PCC bed with cement mortar 1:4, 12 mm thick, (the finished inside dimension shall be 300 x 300 x 300 mm) but excluding test joint, earth continuity conductor to the plate, and covering at the top. (in hard soil)
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 2.00 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
DSR 5.9 Supplying and laying 25 mm X 5 mm GI strip at .5 meter below ground level as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required.joining shall be done by overlapping and with 2 sets of brass nutbolt and spring washer spaced at 50 mm
DSR 5.17 providing and fixing 4 mm dia copper wire on surface for loop earthing as required
Supplying and fixing3 HP DOL starter 3 phase 415 V L&T or equivalent.
supplying and fixing 3 phase heavy duty capacitor bank of suitable including all accessories and giving connection.(for different motors)
supply and fixing 100A MCCB with earth leakage relay in the existing panel board
service charges for preparing necessary drawings, documents,and skechs of the site and electrical installation to submit at KSEBL for the regularisation of aditional load 31 KW
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1051005.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .