| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.1 LAccepted-AOC | L1 | Accepted-AOC AOC | |
| 2 | L2₹40.0 L+₹1.5 L (3.93%)Rejected-Finance | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹40.4 L+₹2.0 L (5.14%)Rejected-Finance | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹40.6 L+₹2.1 L (5.49%)Rejected-Finance | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹42.0 L+₹3.5 L (9.19%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
Tender Value
Refer Docs
EMD Value
₹80,000
Closing Date
4 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (NORTH) AMBALA CANTT
GE (NORTH) AMBALA CANTT
CA NO GE(N)AMB-63(P)/2020-21 PROVN OF CERTAIN SANCTIONED WORKS UNDER AGE B/R-II AND AGE E/M OF GE (NORTH) AMBALA CANTT
2020_MES_405416_1
GE(N)Amb-63(P)/2020-21
Open Tender
Civil Works
Item Rate
182 days
GE (NORTH) AMBALA CANTT
As Per Tender Documents
7 documents required · 7 mandatory
₹500
GE (NORTH) AMBALA CANTT
₹80,000
Yes
15 Feb 2021
8 Jan 2021
6 Feb 2021
8 Jan 2021
4 Feb 2021
22 Jan 2021
8 Jan 2021 - 22 Jan 2021
60 days
Amount
Schedule 'A' part-I ie B/R items
M & L taking down cement or cement lime plaster of any description on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed by the Engineer-in-Charge
M&L 15 mm thick cement plaster on fair faces of brick or concrete walls in CM 1:6, finished even and fair with out using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M & L rendering 15 mm thick on fair faces of brick work or concrete wall surfaces in cement mortar 1:4 and including mixing water proofing compound @ 2% by weight of cement or as per manufacturer's instruction and finished fair and even without using extra cement complete all as specified and as directed by the Engineer-in-Charge. (WPC shall be measured and paid for separately)
Supply only integral water proofing compound complete all as specified and as directed by the Engineer-in-Charge.
M&L 10 mm thick cement plaster on brick or concrete ceiling surfaces in CM 1:3, finished even and smooth with out using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L rough cast plaster 15 mm thick in cement motar 1 :3 complete as specified in SSR Part-I, clause 14.22 shall consisting of following:- firstly apply under coat in cement mortar 1:3 not less than 10 mm thick and while still it is in plastic state the rough cast mixture consisting of crushed stone or fine gravel agg. which is generally of size between 6 to 12 mm depending on texture required mixed with coarse sand and cement in the ratio 1:1 shall be applied, complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of newly plastered/ unplastered surfaces of walls and applying two coats of oil bound distemper with painting roller over a coat of primer over and inlcuding 1mm to 2mm thick wall care putty in two or more coats to achive smooth surface complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of new plastered/ unplastered surfaces of concrete ceiling and applying three coats of white lime wash complete all as specified and as directed by the Engineer-in-Charge.
M&L preparing new plastered surfaces and applying two coats of cement base paint on surfaces of walls complete all as specified and as directed by the Engineer-in-Charge.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing servicable tiles to store and rubbish off the premises complete all as specified and as directed by the Engineer-in-Charge
M & L 25mm thick plain cement concrete 1:2:4, type B-1 using 20mm graded crushed stone aggregate as in sub base, finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L vitrified ceramic dark shade tiles 1st quality (square/rectengular) 10mm thick, area of each tile exc 0.42 sqm but not exc 1.00 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L glazed ceramic coloured tiles joint free1st quality in vertical surfaces/skirtings/dados of size 450x350x7mm thick, set and jointed in neat cement slurry and pointed in white or coloured cement mixed with pigment to match over and including 10mm thick rendering on fair faces of brick / concrete surfaces in cement mortar 1:4 complete all as specified and as directed by the Engineer-in-Charge.
Dismantling wall and ceiling boards (fiber pulp, insulation etc) or insulation boards/ slabs/blankets any thickness including cover fillets and false ceiling frame /gird of any type/any description, fixed in position,complete all as specified and as directed by the Engineer-in-Charge.
S & F of fixing GI OREO Metal Suspended ceiling of approved materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main “T” runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross “T” of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main “T” at 600 mm center to center to form a grid of 1200x600 mm and secondary cross “T” of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main “T” runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, and as directed by Engineer-in-charge. GI Metal Ceiling laying perforated Tegular edge global white colour tiles of size 595x595 mm and 0.5 mm thick with 8 mm drop; made of GI sheet having galvanizing of 100 gms/sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC (Noise Reduction Coefficient) of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation, and backed with a black Glass fiber acoustical fleece.
M & L preparation of new steel and iron surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed by the Engineer-in-Charge.
Taking down chowkhats or frames with shutters (without taking off shutter from the frames) area n. exc 1.5 Sqm each and removal from site complete all as specified and as directed by the Engineer-in-Charge
Taking down chowkhats or frames with shutters (without taking off shutter from the frames) area exc 1.5 Sqm and n. exc 4.00 Sqm each and removal from site complete all as specified and as directed by the Engineer-in-Charge
Supply and fixing steel window box type using ERW hollow 'P' section comprising double frame for and including gauged and glazed skelton shutter 30mm thick, jointed internally with flat iron 25x3mm complete including hinges, handle, tower bolts, stops, lugs, guard bars and painting etc. all as shown on drawing No. TD-219 sheet 1/3 to 3/3 and TD-220 sheet 1/3 to 3/3 as applicable complete all as specified and as directed by engineer in charge. Note: (i) For the purpose of measurement and payment double shutter both glazed and gauzed with frames shall be considered as one unit. (ii) Unit rate quoted against this item shall also include the iron mongery and grill as shown on drgs. (iii) Glazing, wire mesh shall be measured and paid for separately. complete all as specified and as directed by the Engineer-in-Charge.
S&F mild steel wire cloths 0.56 mm nominal dia of wire and average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and as directed by the Engineer-in-Charge
M & L sheet glass 4.0mm thick, ordinary quality and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and as directed by the Engineer-in-Charge
S&F powder coated aluminium door made out of hollow extructed aluminium section of size 101.60 x 44.45 x 1.55 mm for chowkhat, 85 x 44.45 x 1.56 mm for vertical style of shutter, 83.5 x 44.45 x 1.54 mm for middle rail of shutter , 85 x 44.45 x 1.54 mm for top rail of shutter and 150 x 44.45 x 1.54 mm for bottom rail of shutter including neccessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as aluminium tower bolts 200 mm long (2 Nos.), hinges type B-21, 125 mm long (4 Nos.), 150 mm long aluminium handle D or disk type (2 Nos.) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 100 mm size brass mortice lock, vertical type, 6 levers with duplicate key complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, govering pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing 5.5 mm thick tinted glass to aluminium door with glazing clips, rubber etc complete all as specified and as directed by the Engineer-in-Charge.
M & L providing 75 mm thick cement concrete 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in plinth protection laid in alternate bays (n exc 2 Sqm each ) and finished even and smooth without using extra cement and providing joints throughout the thickness of the plinth protection filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight including form work complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of brick tiles single layer laid on roofs etc up to the height of 12 metre complete all as specified and as directed by the Engineer-in-Charge.
Demolition of mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) complete all as specified and as directed by the Engineer-in-Charge. ( up to the height of 12 metre )
Disconnecting existing tanks of any capacity from bldg No. 50 of HQ to corps, setting aside (or lowering if required), taking down carefully old tar felt from roof and removal from site and refixing the tanks in position after carring out roof treatment complete all as specified and as directed by the Engineer-in-Charge.( up to the height of 12 metre )
M & L roughening surfaces of old concrete roof slab by picking, sweeping clean and washing down with water to remove dust, etc and applying neat cement slurry @ 3Kg per Sqm complete all as specified and as directed by the Engineer-in-Charge. ( up to the height of 12 metre )
M & L PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate as in padding, filling in roof deprerepstion, mud stops, roof kerbs on roof slab including fromwork whereever required complete all as specified and as directed by the Engineer-in-Charge. (up to the height of 12 metre )
M & L cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting, grouting with cement and sand slurry 1:3 complete all as specified and as directed by the Engineer-in-Charge. (up to the height of 12 metre )
Material & Labour for providing and laying 3mm thick APP (atactic polypropylene polymer) modified prefabricated five layer weight not less than 3.60 kg /Sqm water proofing membrane black finish reinforced with non woven polyster matt and consisting of a coat bitumious primer @ 0.40 ltr /Sqm by the same membrane manufactures of density 0.87 to 0.89 kg/ltr at 25 degree centegrate temprature and viscosity 70-160 cps over the primer coat with overlap of 100mm at the side and 150mm at the end, the layer membrane shall be laid using butane gas torch and sealing all joints etc after preparing the surface complete as per standred practice as per manufacture's instructions . The vital physical and chemical parameters of the membrane shell be under ;- (i) Joint strength in longitudinal and transverse direction at 23 degree centegrate at 650/ 450 N /5 cms (ii) Tear strength in longitudinal and transverse direction at 300/250N/5 cms. Softing point of membrane not less then 150 degree centegrate when tested in accordance with ASTM (d-5147) (iii) The laying of membrane shell be got down through the authorised applicator of manufactures of membrane only complete all as specified and as directed by the Engineer-in-Charge. (iv) The work shall be carriout at a height upto 12 metre.
M & L cement concrete tiles 25cm x 25cm x 22mm thick, machine pressed, set, jointed and pointed in neat cement slurry with grey cement and no pigments in roof over and including 15mm thick screed bed (1:4) up to 12.00metre height complete all as specified and as directed by the Engineer-in-Charge
Surface excavation (not exceeding 30cm deep) and averaging 15 cm deep, getting out in soft/loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc or for shafts, wells, manholes etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/dense soil complete all as specified and as directed by the Engineer-in-Charge.
M & L PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed by the Engineer-in-Charge.
M&L broken stone hardcore of gauge not exc. 63mm, deposited , spread and levelled in layers n exc 15cm thick, watered and rammed to a true surface complete all as specified and as directed by the Engineer-in-Charge.
Returning, filling in, including spreading, levlling ,watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing surplus excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M&L machine pressed rubber moulded precast concrete interlocking paver block, any shape and size conforming to IS 15658-2006 of 80 mm thickness grade M-40 with grey cement and no pigments over and including a layer of sand cushioning, 25 mm thick complete all as specified and as directed by the Engineer-in-Charge
M&L for brick work with sub class 'B' old size bricks straight or curved on plan exceeding 6 metre mean radius built in cement mortar 1:6 complete all as specified and as directed by the Engineer-in-Charge.
M & L providing cement concrete 1:2:4 Type B1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by the Engineer-in-Charge.
M & L RCC 1:2:4 type B1 using 20mm graded crushed stone aggregates as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed by the Engineer-in-Charge.
M&L TMT mild steel bars 10mm dia and over cut to length, bent to shape reqd incl cranking, bending, spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less than 0.9mm dia complete all as specified and as directed by the Engineer-in-Charge.
M & L mild steel TMT bars 5mm dia and over upto including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and as directed by the Engineer-in-Charge
M&L form work to soffits of suspended slabs such as roof slabs, , floor slabs, landings and similar work n exc 200mm thick, finished rough surfaces of concrete flat complete all as specified and as directed by the Engineer-in-Charge.
M & L formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for roughed finished surface of concrete complete all as specified and as directed by the Engineer-in-Charge
M & L plain cement concrete 1:3:6 type C1 using 20mm graded crushed stone aggregate as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating including formwork for rough finished surfaces of concrete complete all as specified and as directed by the Engineer-in-Charge.
M & L providing precast cement concrete 1:2:4 type B1 using 20mm graded crushed stone aggregate as in window or door cills, lintels, bressumers, steps, quoin blocks (for use with masonry),string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks, ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, including chamfers, weatherings, throating etc. and setting in cement mortar 1:4 complete with joints to match complete all as specified and as directed by the Engineer-in-Charge.
M & L 75 mm thick PCC 1:4:8 type D2 using 40mm graded crushed stone aggregate as in sub base of floor/ hard standing etc and finished even and fair without using extra cement complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in floors, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including screed bed or bedding layer 15 mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
M&L Non-skid ceramic coloured tiles joint free 1st quality (square/rectengular) 7 to 8 mm thick, area of each tile exc 0.11 sqm but not exc 0.18 sqm as in skirting/ dado, set and jointed in neat cement slurry and pointed in coloured cement to match the surface over and including rendring 10 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick with Az-150 coating of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws with neoprene and EPDM washers and laps to be sealed, HDPE fillers to close gap between raised portion or structural steel with roof complete all as specified and as directed by the Engineer-in-Charge.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick Az-150 coating of any colour having tensile strength 550 Mpa as in roof covering , fixed with self tapping screws with neoprene and EPDM washers and laps to be sealed, HDPE fillers to close gap between raised portion or structural steel with roof complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S. 1161-1979 grade St-240 complete all as specified and as directed by the Engineer-in-Charge.
M&L preparation of old decorated steel surfaces of any description, not otherwise described, over 10 cm width or girth and applying two coat of synthetic enamel paint complete all as specified and as directed by the Engineer-in-Charge.
M&L rolled mild steel framed work as in door or gates of angle or other section with gusset plates, rails braces etc. complete. drilled for fixing for steel sheeting or other covering doors, etc to be prepared for hanging or sliding with and including either hooks and hinges and hanging ,door fitting (exclusive of steel sheeting or other covering, running rails and guides) also fastening and fixing including one shop coat of zinc chromate primer conforming to Fe-410-(Gde E-250) quality 'A' complete all as specified and as directed by the Engineer-in-Charge.
M&L 2nd class hard wood 35 mm thick plain framed panelled shutter( two panel) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on boths face . The size of rail and style as per IS:1003 (Part-1) kiln seasoned and chemically pressure treated complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium anodised barrel tower bolts of extruded section and fixed complete all as specified and as directed by the Engineer-in-Charge.
S & F mild steel butt hinges 100 mm long medium weight old rolled stainless steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
S&F 150 mm long aluminium handle cast type anodised complete all as specified and as directed by the Engineer-in-Charge.
S&F, aluminium alloy anodised sliding door bolts , of 250 mm long with hasp,staple(bolt type) and fixing clips of sheet, cast or extruded section , fixing bolts and sliding bolts of extruded section and fixed, complete all as specified and as directed by the Engineer-in-Charge.
S & F 2nd class hardwood small fittings such as brackets of any type, latch and hinge blocks, shapped door and window stops and the like, including all necessary labours; articles n exc 200 cu. cm each complete all as specified and as directed by the Engineer-in-Charge
Supply only mild steel butt hinges 50 mm long medium weight old rolled mild steel and fixed complete all as specified and as directed by the Engineer-in-Charge.
M & L preparation of new wooden surfaces of any description, not otherwise dscribed, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix solid PVC wall lining consisting of 5mm thick wood grain printed PVC sheet inclusive of solvent cement and fixing at site on PVC frame as per specifications and drawing given on page No. 162 of SSR -2010 (Part II- rates) complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC frame as per specification and drawing. given on page No. 162 of SSR -2010 (Part II- rates) complete all as specified and as directed by the Engineer-in-Charge.
Schedule 'A' part-II ie E/M items
Taking down carefully copper/aluminum point wiring (light, fan, socket or power) complete including all fittings and fixtures such as switches, pendant, lamp holder, regulators, switch, socket outlet, bulk head fittings, tube light fittings, calling bell etc and removing unserviceable materials from site of work and making good disturbed surfaces of walls, floors with cement mortar and white/colour wash to match with existing surfaces etc complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets,modular fan regulators etc. and making smooth the disturbed surfaces as per existing for one light/fan/exhaust fan point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Description same all as per item No. 2.02 but for One 3 pin, 5 Amps, socket outlet controlled by one switch on independent board, complete all as specified and as directed by Engineer-in-Charge.
Description same all as per item No. 2.02 but for One 3 pin 5 Amps socket outlet controlled by one switch on same board, complete all as specified and as directed by Engineer-in-Charge.
Material and labour for Point wiring with 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall surfaces and on surface on ceiling surfaces and incuding provision of 4.00 Sqmm single core PVC insulated , unsheathed cable FRLS-H, 1100 volt grade with multi stranded copper conductor green colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer both internally and externally including provision of new covered plate over sunken box for housing the modular switches , modular socket outlets, etc. and making smooth the disturbed surfaces as per existing for 3 pin, 15 Amp socket outlet point controlled by one way switch, complete all as specified and as directed by Engineer-in-Charge. Note :- a) .All chases will be cut by chase cutter only b) Switch, socket outlet and fan regulators to be measured and paid for separately .
Supply and fix modular switch 1 module, single pole, one way 6 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & Fix modular socket outlet 2/3 pin, 6amp, one way, two module, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply and fix modular switch 1 module, single pole, one way 16 Amps flush type, 230 volts complete all as specified and as directed by Engineer-in-Charge.
Supply & fix TV modular socket outlet 2/3 pin, one way, two module complete all as specified and as directed by Engineer-in-Charge.
S&F of electronic Fan regulator modular 120 watt 2 module 230 volts , 50 Hz, AC supply suitable for ceiling fan any type/make/sweep complete all as specified and as directed by the Engineer-in-Charge.
S&F ding dong bell, 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S&F modular bell push 6 Amp 1 way 2 module 230 volts complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing lamp holder, PVC/polycarbonate type with back plate suitable for batten fittings, complete all as specified and as directed by Engineer-in-Charge.
Supply and fix LED Bulb, pin type 12 watt, energy efficient complete all as specified and as directed by Engineer-in-Charge.
Supply and fix MCB single pole, 240 volt, 6 to 32 amps, 10 KA 'C' curve complete all as specified and as directed by Engineer-in-Charge.
Taking down MCB DB SPN or TPN alongwith MCCBs/MCBs and MCB DB plug & socket boards alongwith MCBs of any description and making good the disturbed surfaces of walls and paint touch up to match with existing finishes as per site requirement complete all as specified and as directed by Engineer-in-Charge.
Fixing only servicable MCB DB SPN or TPN alongwith MCCBs/MCBs of any description obtained from item No. 2.18 here in above and making good the disturbed surfaces of walls and paint touch up to match with existing finishes as per site requirement complete all as specified and as directed by Engrin-Charge.
Supply and fix sheet metal MCB DBs 12 way, single pole and neutral, double door, IP 43, as per IS 8623 with 100/200 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing reversible doors, PAN assembly for essy installation fixed on wall duly grouted in solid block wall or on wooden board and including copper lugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix sheet metal MCB DBs 8 way, single pole and neutral, double door, IP 43, as per IS 8623 with 100 Amps fully insulated copper bus bar, insulated neutral bar, earth bar, door earthing reversible doors, PAN assembly for essy installation fixed on wall duly grouted in solid block wall or on wooden board and including copper lugs/thimbles duly crimped for connection, necessary PCC work and making smooth the disturbed surface complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix RCBO 40 Amps, 2 Pole, 2 module 300 mA (HI immunity) sensitivity 230 volts 50 Hz, complete all as specified and as directed by the Engineer-in-Charge.
Supply and fix over and low voltage release 230 volts, single phase in one module, suitable for (1 Ph+n) AC, adjustable for 170volts to 230 volts complete all as specified and as directed by the Engineer-in-Charge.
S & laying as in repair sub main wiring with two run of 6 sqmm PVC insulated , unsheathed cable FRLS-H,1100 volts grade ISI marked with multi stranded copper conductor and one run of 6 sqmm PVC insulated , unsheathed cable FRLS-H, 1100 volt grade ISI marked multi stranded copper conductor as earth continuty conductor connected to common earth dolly including concealed on wall and surface on ceiling in PVC conduit medium grade ISI marked of 25 mm dia for housing the wires complete all as specified. Note: (i) Thimble/lugs of rating of MCB should be used with wire for fixing in the MCB. (ii) Three runs of cable and one run of PVC conduit shall be measured and paid as one unit length.
Supply and fixing indoor decorative LED tube light fitting box type 1x18/20 W with opal diffuser, high efficient aluminium housing body in CRCA body suitable for LED tube, high efficient, AC 220-240 volts, 50 Hz and including 1x18/20 W LED tube rod luminaries (Warm/Cool as per site requirement) environment friendly, high efficient, with aluminium extrusion heat sink connecting with copper conductor flexible cable from ceiling rose to connector of the light including disconnecting and taking down existing light fitting and removal complete all as specified and as directed by the Engineer-in-Charge.
Supply and fixing recess mounted indoor decoraative, vertically/horizontally mounting, top opening, LED light fitting 2'x2' box type with a unique drop down opal diffuser, leading to uniform lighting experience illuminating high efficient aluminium housing body in CRCA body suitable for LED, high efficient, AC 220-240 volts, 50 Hz and including 33 watt LED luminaries (Warm/Cool as per site requirement) environment friendly , aluminium extrusion heat sink and connecting with copper conductor flexible cable from ceiling rose to connector of the light complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing in repair 10 watt LED plastic batten fitting 2 ft with rod, driver and all accessories, prewired upto terminal block including connecting with 3 core copper conductor flexible cable from terminal box to the ceiling rose or connector of the light point complete all as specified and as directed by Engineer-in-Charge.
S&F LED Bldg Security Light Fittings of capacity 40 -45 watt made up of die cast aluminium housing with black epoxy powder coating with cover heat resistance glass safety input voltage range 170 to 270 volts, industrial model with IP-65 protection and other connected accessories including service bracket of GI pipe 32 mm bore medium grade of length 1.60 mtr with MS clamps, bolts, nuts, and washers and suitable reducer for connecting fitting to GI pipe as required at site including two coats of synthetic enamel paint over a coat of red oxide primer on mild steel work and making electrical connection, including disconnecting and taking down existing old Unserviceable fitting complete all as specified and as directed by the Engr-in-charge.
Supply and laying XLPE insulated, armoured heavy duty electric cable 25 sqmm cross sectional area 3.5 core with multi stranded aluminium conductor, 1100 volts grade, including disconnecting and taking down old U/S existing cable complete all as specified and as directed by the Engineer-in-Charge.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for laying of cables. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and as directed by Engineer-in-Charge.
Returning, Filling in excavated soils including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and as directed by the Engineer-in-Charge.
M & L for dry sand as cushioning to cable 8 cm before laying cable in trenches and 15 cm after laying the cable and compacting, complete all as specified and as directed by the Engineer-in-Charge. Note:- for measurement, punned thickness shall be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class LV, type 1 flat, size 250 mm x 150mm x 40mm complete all as specified and as directed by Engineer-in-Charge.
S&F light grade GI Tubing of size 40 mm dia for cable protection and fixed with clamp to pole and wall with nut bolts, including complete all as specified and as directed by the Engineer-in-Charge.
Taking down ceiling fan, sealing cable end, dismantling blades and applying one coat of painting on ceiling fans with synthetic enamel paint by spraying incl filling cavaties with filler after cleaning all dust etc.and reassembling the same complete all as specified and as directed by the Engineer-in-Charge.
Fixing only the ceiling fan and connecting up including provision of flexible cable cable 23/.0076 from ceiling rose or connector to fan complete all as specified and as directed by the Engineer-in-Charge.
S&F single pole and neutral enclosure with a two pin and earth plug and socket 20 Amp complete with and including one single pole MCB.20 Amp, 10 KA 'C' curve complete all as specified and as directed by the Engr-in-charge.
M & L rigid non-metallic 20mm dia PVC conduit inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.complete all as specified and as directed by the Engr-in-charge.
Supply and fix exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, 1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Material and labour making hole of suitable size in existing one brick thick masonry wall suitable for fixing exhaust fan of size 300mm sweep and making good the disturbed surfaces as per existing specification and paint touch up etc to match with existing surface complete all as specified and as directed by Engineer-in-Charge.
S & F 15mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F 20mm bore cast copper alloy chromium plated stop valves, screwed down, high pressure with butterfly handle, scrwed both ends for iron pipe or for unions complete all as specified and as directed by the Engineer-in-Charge.
S & F in repairs galvanised iron tubing 20 mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
S & F in repaire galvanised iron tubing 15mm bore medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and as directed by the Engineer-in-Charge.
Supply & Fix Water heater (Geyser) storage type electric of capacity 25 Ltrs , BEE 5Star rated, ABS body, metal tank with glasss lined coating, multiple heating option, shock safe plug, puf insulation, incoloy glass coated anode rod / copper heating element of capacity 2KW with ISI mark , adjustable knob for temp setting with minimum 8 MPa high working pressure, multi functional safety valve & whirl/Swirl flow technology, thermostat electronic type, thermal cutout capillary type complete including superior quality copper connection pipe heavy duty 15mm dia 450mm long, brass adopter for water connection with nikhel coated ISI marked with fastner, nut bolts, washers duly grouted, giving shape to hole as suitable and plastering including making good of disturbed surface as per existing surface, connecting to inlet and outlet valves, testing complete all as specified and as directed by Engineer-in-Charge. Note :- Warranty certifcate to be produced by the Contractor from OEM for the following components before processing the bill. a) for Product - 02 Years b) for Heating element - 03 Years c) for metal tank - 07 Years
Supply & fix chromium plated Brass wall mixer, external fixed type for hot and cold water supply including required fixtures and fittings suitable for 15mm bore pipe complete all as specified and as directed by Engineer-in-Charge.
Supply & fix copper strip 20 x 3.15mm thick with saddles and fixing screws etc. for roof conductors and down conductors above ground with insulators at a distence of 50 cm on wall complete all as specified and as directed by Engineer-in-Charge.
Supply & fix aluminium strip 25 x 3.15mm thick with saddles and fixing screws etc. for roof conductors and down conductors above ground with insulators at a distence of 50 cm on wall complete all as specified and as directed by Engineer-in-Charge.
Supply and laying GI strip of size 32 x 6mm thick and buried in the ground complete all as specified and as directed by Engineer-in-Charge.
Supply and fix air termination, single pointed, copper rod 12mm dia and 300mm long with insulator complete all as specified and as directed by Engineer-in-Charge.
Supply and fix air termination, single pointed, aluminium rod 12mm dia and 300mm long with insulator complete all as specified and as directed by Engineer-in-Charge.
M & L test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw including insulator complete all as specified and as directed by Engineer-in-Charge.
S& F PVC rectangular block for mounting and fixing horizontial, vertical & down conductors on roof and wall to provide insulation from lighting thunder current of size 100 x100 x 50 mm including fastner such as screws, nuts, bolts and washers etc complete all as specified and as directed by Engineer-in-Charge.
S& F PVC rectangular block for strong base on old vintage PCC sheet roof and fixing horizontial, vertical & down GI strip on it to provide insulation from lighting thunder current of size 175 x100 x 50 mm including fastner such as screw, nuts, bolts and washers etc complete all as specified and as directed by Engineer-in-Charge.
Material & labour in repair earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised iron strip earth lead of 25x 3mm thick size by means of bolts, nuts, check nuts and washers of galvanised iron, earth strip protected by GI pipe 40mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . Note :- GI strip 25x3 mm thick upto 7.5 mtr length to be considered as one unit and cost thereof shall be included in the quoted rate.
M & L for earthing complete with Copper earth plate electrode 600 x 600 cm x 3.15 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connecting to copper strip size 20x 3mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel and earth strip protected by 25mm dia GI pipe medium grade and connected to distribution board/earthing test point all as shown in electircal plate No. 3 of SSR Part-I(2009) and testing on completion complete all as specified and directed including taking down unserviceable earthing. (a) Note :- The unit rate quoted shall also include for excavation, earth work in any type of soil, plain cement concrete 1:3:6 mix, Type C1 pit, 40mm thick RCC 1:2:4 mix type B1 cover reinforced with 8mm dia TMT bras @ 150mm C/C both ways, GI funnel with watering pipe, wire mesh,protection pipe for earth lead upto 7.50m long complete in addition to item No. 1(a) to (e) of preamble (Notes) under sub heading earthing, specified in SSR Part II. (b) Note :- Copper strip 20x3mm thick upto 7.5 mtr length to be considered as one unit andcost thereof shall be included in the quoted rate.
Supply & fix mild steel iron of size 75mm x6mm thick or as required at site for providing strong base and structure to fabricate the shape and size as per ground requirement to fix the roof conductor on it with all necessary accessories/attachment including to coats of synthetic enamel paint over a coat of red oxied primer complete all as specified and as directed by Engineer-in-Charge.
Material & labour earthing complete with galvanised steel earth plate electrode 600x600x6 mm thick buried directly in ground (earth pit not less than 2.25m deep below the ground level) with top edge of the plate not less than 1.5mtr below the normal ground level connected to galvanised earth lead of 4mm dia GI wire by means of bolts, nuts, check nuts and washers of galvanised iron.Earth wire protected by GI pipe 15mm bore(medium grade) and connected to main switch board or main control board as directed and as specified and shown in electrical plate No. 3 of SSR Part I (2009) including necessary concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1 cover slab 40 cm x 40cm x 5cm reinforced with 8mm dia TMT bars @ 15cm c/c with one handle for lifting made out of 8mm dia bar, funnel, wire mesh, 20mm dia GI pipe medium grade for watering, charcoal or coke and salt in alternate layers including necessary excavation and earth work in any type of soil and testing complete all as directed by Engineer-in-Charge and earth testing on completion . Note :- GI wire 4mm dia upto 7.5 mtr length to be considered as one unit and cost thereof shall be included in the quoted rate.
Ashwani Kumar
Karishan Kumar goel
bhagwandasswazirchand
Swami Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .