Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
₹2.2 L
EMD Value
₹4,400
Closing Date
12 Feb 2025, 6:00 pmClosed
EE(C), CD-I, Hyderabad
Executive Engineer (C), BSNL Civil Division-I, Room No. 703, VII floor, BSNL Bhawan, Adarsh Nagar, Hyderabad - 500063
Dismantling and transportation of BTS shelter from Thimmajipet, Nagarkurnool SDCA to TE compound Rajoli, Gadwal SDCA, including providing foundation etc at Rajoli, Gadwal SDCA,Mahabubnagar OA, MEDAK BA
2025_BSNL_225781_1
NIT No. 17 /NIT/CECTSCZ/HYD/2025
Open Tender
Civil Works
Item Rate
30 days
Thimmajipet
Please refer Tender documents.
4 documents required · 4 mandatory
₹590
Accounts Officer (Cash), O/o GMT, BSNL Medak BA
₹4,400
14 Feb 2025
4 Feb 2025
14 Feb 2025
4 Feb 2025
12 Feb 2025
4 Feb 2025
4 Feb 2025 - 12 Feb 2025
Amount
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand).
Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) upto plinth level with :
Cement mortar 1:6 (1 cement : 6 coarse sand).
20 mm cement plaster of mix :
1:6 (1 cement: 6 fine sand)
Providing and fixing plain lining/ flooring with necessary screws/nuts & bolts/nails fixed on wooden /steel frame work, complete as per direction of Engineer-in-charge.
a) 12mm thick Marine ply (BWP) grade conforming to IS : 710:2010
Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer in- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
Assembling/Erection of BTS shelter of size 3.13X2.14X2.75 m including jointing the panels with pop up rivets, injecting the silicon sealant at panel joints and fixing to the bottom runners with SS nuts. Cost includes all labour charges , materials like Silicon sealant, pop up rivets and ss nuts * bolts of size M6X75mm etc all complete.
Dismantling of BTS shelter of size 3.13X2.14X2.75 m including stacking of shelter panels in good condition for re-erection etc all complete as directed by Engineer-In-Charge.
Mechanical transportation of BTS shelter(3.13X2.14X2.75) materials from BTS site Thimmajipet Nagarkurnool SDCA, to TE compound Rajoli, Gadwal SDCA Kollapur including, unloading and shifting to third floors etc all complete . Aprroximate lead of 140.0Km
Providing and laying of 2.00 mm thick Antistatic polyvinyl chloride sheet of approved brand TUSKER or equivalent on a smooth and damp proof base using rubber based adhesives (viz. Dunlop 8753 or equivalent) including rolling with light wooden roller weighing about 5 kg all complete including providing 40 mm wide copper strip fixed to floors with rivets / nails where ever required as per manufacture specifications. The copper strip shall be provided along the periphery of the room leaving 200mm border and under all pvc sheet joints. The copper strip shall be exposed at required locations. The rate includes all materials specified above.
Providing and fixing anchor fasteners (expansion fasteners) of approved quality including drilling holes in RCC and fixing complete
a) 12 mm dia and 100mmm length
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .