SE EDC RAMPUR
office of the SE, EDC, RAMPUR
40/2023-24/EDCR Releasing new connection/ shifting of lines/increasing capacity etc. under deposit scheme in future for the period 01-10-2023 to 30-09-2024 jurisdiction of EDD-I, Rampur.
2023_PVVNL_837925_1
40/2023-24 (EDCR)
Open Tender
Electrical Works
Lump-sum
30 days
office of the SE, EDC
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
SE EDC RAMPUR
₹5,000
Yes
21 Dec 2023
14 Sept 2023
29 Sept 2023
14 Sept 2023
29 Sept 2023
14 Sept 2023
Amount
Safe carriage of following material from Store Centre to site / JE store with loading & unloading at both ends respectively distance with in 60 Kms.
PCC Pole 8.5 Mtr. Long
PCC Pole 9 Mtr. Long
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
11 KV CT/PT Unit
11 KV Pilfer Proof Metering Cubical
11/0.4 KV 25 KVA T/F
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
33 KV Line Isolater
11 KV TPMO
Loading & safe carriage & unloading of heavy other line material (other than pole) such as ACSR Weasal/Dog Conductor, M.S. Angle, M.S. Channel, Stay Rod, Earthing Rod, 11 KV Cable, L.T. Cable etc. from Store Centre to site / JE store distance with in 60 Kms. and back cartage of material if required.
The excavation of foundation pit in mix. Soil / normal soil / soft & hard rock and its back filling and leveling etc. The size of the pit will be (750 x 450) mm and having depth of 1/6th of the full length of the support, erection of support complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as and fabrication work if required. (Single Pole)
PCC Pole 8.5 Mtr. Long
PCC Pole 9 Mtr. Long
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
The excavation of foundation pit in mix. Soil / normal soil / soft & hard rock and its back filling and leveling etc. The size of the pit will be (750 x 450) mm and having depth of 1/6th of the full length of the support, erection of support complete with providing & fixing of all clamps and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit size as well as and fabrication work if required & fixing of cross bracing sets 2.5 mtr. From M.S. Angle 50x50x6 mm. the work includes cutting holes and providing M.S. Bolt of 16x40 mm. size in the middle of the cross bracing with 01 no. spring washer of proper size as per drawing. (Doube Pole Structure)
PCC Pole 8.5 Mtr. Long
PCC Pole 9 Mtr. Long
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
Grouting of supports in CC 1:4:8 (cement, sand & 40 mm brick ballast). Grouting will be done in the block of size (450x450) mm x 1/6th of full length of the support up to ground level, 300 mm plinth, above the ground level with CC 1:3:6 (Cement, Coarse Sand & Stone Grit) with muffing as per drawing. Work includes back filling and proper ramming. (i) Single Pole
PCC Pole 8.5 Mtr. Long
PCC Pole 9 Mtr. Long
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
(ii) Double Pole
PCC Pole 8.5 Mtr. Long
PCC Pole 9 Mtr. Long
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
Grouting of Stay Rods (16x1800) mm. including all work of excavation, cement, concreting in size (0.60x0.60x0.30) m in ratio 1:4:8 cement, sand, 40 mm brick ballast as per drawing, including back filling of soil and proper ramming etc.
Fixing, tightening & nozzling of stay wire with stay rod with the poles of required tension as per drawing, including providing & fixing of stay insulators of 11 KV and stay clamps.
Earthing of supports with M.S. Earth Rod of (20x2500) mm long including excavation of pit and driving M.S. Rod 3-0 M apart from support and 0.5 m below the ground level and connecting below the earth electrodes with the help of G.I. Wire No. 8 SWG and earthing lugs.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Weasal Conductor in accordance with line chart including binding and fixing of all accessories in conductor conductor in parallel in 11 KV / L.T. Line.
Laying, spreading, lifting and final sagging of 3 phases of ACSR Dog/Rabbit Conductor in accordance with line chart including binding and fixing of all accessories in 03 Nos. conductor in parallel.
Guarding between two poles single poles, double poles etc. to guard L.T. Line, telephone and river crossing, road crossing etc. with G.I. Wire No. 6 & 10 SWG.
Removal of old existing transformers from double pole/ plinth after dismantling H.T. & L.T. Connections along with back cartage from work site to store centre includng loading & unloading at both ends distance with in 60 Kms.
11/0.4 KV 25 KVA T/F
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
11/0.4 KV 400 KVA T/F
Mounting of following transformers of different capacities, on Double Pole / Plinth alongwith fixing of clamps and nuts & bolts with proper binding / jumpering etc.
11/0.4 KV 25 KVA T/F
11/0.4 KV 63 KVA T/F
11/0.4 KV 100 KVA T/F
11/0.4 KV 250 KVA T/F
11/0.4 KV 400 KVA T/F
Safely laying of 11 KV AB Cable size of cable 3x50 sq. mm.
Safely laying of 11 KV AB Cable size of cable 3x95 sq. mm.
Safely laying of 11 KV AB Cable size of cable 3x120 sq. mm.
Safely laying of 11 KV Cable size of cable 3x120 sq. mm.
Safely laying of 11 KV Cable size of cable 3x150 sq. mm.
Safely laying of 11 KV Cable size of cable 3x185 sq. mm.
Laying of underground 11 KV Cable (3x35/3x70/3x150/3x185) after digging of trench including cost of sand & brick complete in all respect.
Dismantling of old CT/PT Unit from D/P.
Mounting of CT/PT Unit on Double Pole.
Dismantling of old metering cubical.
Mounting the metering cubical on foundation & grouting with rag bolts.
Mounting the 11 KV TPMO
Installation of 33 KV Line Isolater(In yard)
Filling & fixing of 11 KV Cable Jointing Kit
Filling & fixing of 33 KV Cable Jointing Kit
Fixing of G.I. Pipe 6" dia on double pole with providing & fixing Clamps and Bolts & Nuts complete in all respect.
Back Cartage of dismantled CT/PT Unit from work site to Store Centre Rampur with loading & unloading at both ends distance with in 60 Kms.
Back Cartage of dismantled metering cubical from work site to Store Centre Rampur with loading & unloading at both ends distance with in 60 Kms.
Providing & fixing of danger board at each location as per specification of the drawing.
Wrapping of barbed wire on 11 KV SP-55 S.T. Poles / 8.5 Mtr. PCC Poles, as anti climbing device for a length of 0.9 mtr. Wire pitch / gap 13 mm. and fixing upper and lower end keeping, lower end at a height of 2.75 mtr. From the ground complete with providing and fixing of lower end & upper end clamps made of M.S. Flat 40x5 mm. complete with nuts & bolts.
Dismantling of old existing supports with all accessories for shifting of line complete in all respect. (Single Pole.)
PCC Pole 8.5 Mtr. Long
PCC Pole 9 Mtr. Long
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
Double Pole Structure
PCC Pole 8.5 Mtr. Long
PCC Pole 9 Mtr. Long
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
Fixing of X-Arm of 11 KV line with nuts & bolts & washers as per RESPO norms complete in all respect. (Provided by department for shifting of line)
Construction of plinth for 250 KVA Transformer 2x2x1.5 M with fencing as per RESPO Norms and as per direction of Supervising Engineer (Material for plint and fencing will be provide by the Contractor)
Fixing of Insulators (Provided by department):
11 KV Pin Insulator with Pin
11 KV Disc Insulator with Fitting
Painting of Pole
S.T. Pole 11 Mtr. Long
S.T. Pole 13 Mtr. Long
Providing & fixing of Insulators & Clamps:
Clamp for T-Off with Bolts & Nuts
Clamp for D/P (Top, Dropper etc.) with Bolts & Nuts
Guarding / X-Arm Holding Clamp with Bolts & Nuts
F-Bracket with Bolts & Nuts
E-Bracket with Bolts & Nuts
P.G. Clamp for Weasal Conductor
P.G. Clamp for Dog Conductor
L.T. Shackle Insulator with Bolts & Nuts
L.T. Clamp with Bolts & Nuts
G.I. Pipe 6" dia
Stay Insulator with Bolts & Nuts
Stay Clamp with Bolts & Nuts
PVC LT Seprator.
Red oxide paint with painting
Aluminium paint withh painting
Krishna Electricals
munfad electricals
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .