Executive Engineer
PH Division Muvattupuzha
StatePlan RWSS to Thirumarady State plan 2026 27 Supply and erection and commissioning of new submersible pump set in Oliyapuram Pump house in Thirumarady Panchayath Under Elanji P.H.Section General Civil Work
2026_KWA_883961_1
29/2026-27/EE/PHDN/MVPA
Open Tender
Civil Works - Water Works
Percentage
Thirumarady Panchayath
Please refer Tender documents.
7 documents required · 7 mandatory
₹640
₹7,246
19 Nov 2026
30 Oct 2026
20 Nov 2026
30 Oct 2026
19 Nov 2026
30 Oct 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1APP H:Supply and erection of open well submersible pump set having discharge 6 LPS and total head of 120 m at Olyapuram pumphouse in Thirumarady Panchayath-pumping to Oliyapuram | |||||
| 1.001 | OD258165/2025-2026:Supply and erection of open well submersible pump set with the following specification 1. Pump -Supply, erection, testing and commissioning of KWA per-qualified, bronze impeller SS shaft CI pump case total head 120 M discharge 6 lps 2. Motor Supply , erection, testing and commissioning of KWA per-qualified reputed make vertical solid shaft submersible induction motor suitable for the above pump working 3 phase 50 Hz Ac supply, working voltage 415. Th motor shall confirm to EEF1/IS 325 . Starter Supply , erection ,testing and commissioning of suitable rating Fully automatic star delta starter with air break contact .Starter suitable for the above motor with over voltage and under voltage protection , single phase preventer, over load, phase unbalancing with motor protection relay as per IE rules and code of practice etc. complete. 4. Panel board (Suitable for operating two pump sets but one pump set at a time) Supply , erection, testing and commissioning of cubical type wall mounted MS fabricated dust and vermin proof common control panel board consisting of 1 No. 100A ,36ka rating motor protection MCCB as incomer and two nos 100A 35ka MCCB outgoing (two MCCB interlocking each other) and providing correct size Aluminum bus bar to interconnect the above MCCBs and fitted with 3 Nos of indicator lamps,1 No. volt meter with selector switch ,1 No. Ammeter with selector switch for measuring current in each phase etc. Complete and provided with a common earth bus for the entire panel and inter connect with the MCCBs as per IE rules and code of practice. The panel shall be fitted on a common base frame on suitable foundation. 5. Cabling Supply, laying testing and commissioning of suitable size XLPE copper cables for the above pump set from panel board to starter and from starter to motor considering energy conservation. 6. Earthing Supply of all materials and providing suitable earthing by using suitable size pipe /plate earthing GI/copper strip buried in ground and giving double earthing to motor, starter , panel board etc. as per IE standards.7. Capacitor Supply, erection testing and commissioning of heavy duty APP capacitor for the motor to get a power above 0.95. Capacitor connected to external contact, The capacitor shall confirm to IS 28348. 8.Valves supply of suitable size best quality heavy duty ISI marked CI double flanged sluice and non return valve with suitable pressure rating . Fitting of valves shall included proper RCC support especially for non return valves . In case of positive suction 9. Suction and delivery pipe connection Supply and fittings of suitable size best quality GI/MS pipe of shell thickness not less than 8 mm for a total of 10 M. suitable for the above pump set and suitable size foot valve and connecting the suction pipe and valve with suitable flanges, nut &bolt IR sheet etc. complete and connecting the delivery side of the pump with the valves and suitable specials to connect with the pumping main. | 1 | no | 2,84,422.31 | ₹2,84,422.31 |
| 1.002 | OD258166/2025-2026:Supplying and fixing commissioning Mobile operated GSM based module for operation of starters and controller from anywhere using mobile phone with design tested to perform reliably even in extreme environmental conditions, suitable for single phase and three phase installations, communication with IVRS in local languages, 3 user can control the operation, power fail and feed back SMS in regional languages, four different "time of day" can be set in a day for pump operation, controls daily operations of a pump for pre-defined periods and ease of operation with advanced facilities such as auto switch off while dry run with in fraction of seconds, low voltage preventer, phase change preventer, low voltage cut off, online monitoring system,including water level controller, etc,, of reputed make. | 1 | no | 5,410.03 | ₹5,410.03 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
KWAGeneralConditionsforeTenderingV5.pdf
PDF • 0.69 MB
Tendernotice_1.pdf
PDF • 1.69 MB
BOQ_1505751.xls
BOQ • 0.31 MB
NITe.pdf
Tender Documents • 1.05 MB
Circularsordersandconditions.pdf
Tender Documents • 13.07 MB
29EXTENSIONII.pdf
PDF • 0.20 MB
Tenderextension1.pdf
PDF • 0.18 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .