| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC C O MALAY DUTTA MADHYAPARA OPP DARRANG COLLEGE GIRLS HOSTEL P O TEZPUR DISTT SONITPUR ASSAM 784 001 | SONITPUR | ASSAM | 784001 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹39.7 L+₹9,603.60 (0.24%)Rejected-AOC | L2 | Rejected-AOC Become L2 | |
| 3 | L3₹45.3 L+₹5.7 L (14.4%)Rejected-AOC HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L3 | Rejected-AOC Become L3 | |
| 4 | L4₹49.4 L+₹9.7 L (24.5%)Rejected-AOC | L4 | Rejected-AOC Become L4 |
Tender Value
Refer Docs
EMD Value
₹95,400
Closing Date
14 Jan 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE SOUTH TEZPUR
GE SOUTH TEZPUR MISSION CHARALI
PROVN OF CERTAIN LBW, REV AND MINOR WORKS AT MISA CAMP UNDER GE (S) TEZPUR
2020_MES_404671_1
8545
Open Tender
Civil Works
Item Rate
180 days
GE SOUTH TEZPUR
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE SOUTH TEZPUR
₹95,400
Yes
9 Feb 2021
18 Dec 2020
16 Jan 2021
18 Dec 2020
14 Jan 2021
1 Jan 2021
60 days
Amount
S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction but welded tubes conforming to IS- 1161-1979 grade St-240 complete all as specified and directed
M & L framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc, n.exc 10Kg each brackets, conforming to 290 Gde-E-165(Brackets over 10 Kg each to be measured under "Structural Steel " complete all as specified and directed.
S&F Mild steel screw bolts (machine made), diameter of neck 16 to 20mm, length of bolt exc 22.5cm and n exc 30cm longwith hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
S & F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified
All as per item no. 4 above but plain in ridges complete all as specifed and directed.
M&L preparation of new steel surfaces and apply two coats of synthetic enamelled paint over a coat of red oxide primer over 10cm width or girth
Excavation in trenches n exc 1.5 mtr depth and n exc 1.5 m wide in soft/loose soil and getting out.
M&L PCC (1:4:8) type D-2 using 40 mm graded stone agg as in fdn filling mass concrete.
M&L for RCC 1:1.5:3 using ( 20 mm graded agg) as in foundation, base for column , plinth beam etc.
S&F 10mm dia and over TMT bars as in reinforcement cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90 m dia.
S&F TMT bar 5 mm dia and over upto including 10 m dia in stirrups, spacers and binder etc,cut to length bent to shape etc as required incl binding with MS wire annealed not less than 0.90m dia.
M&L brick work using sub class B brick (old size) curved or straight in plan exc 6 mtr mean radius in cm (1:6)
M&L for PCC 1:2:4 type B1 (using 20mm graded agg) as in cooping /benchingcomplete all as specified and directed.
M&L 15 mm thick rendering in CM 1:4 on wall, finished the surface even and fair complete all as directed
M&L for applying two coats of weather coats (Apex) paint on exterior wall oer a coat of damp shield primer includings preparation of new plastered surface complete all as directed.
M&L PCC 1:3:6 type C-2 75 mm thick as using 40mm graded aggregate as in plinth protection /pavement/bedding of footpath even and smooth without using extra cement.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in hard/dense soil complete all as specified and directed.
Removing excavated materials n.exc 50 mtrs and depositing where directed at a level n exc 1.50mtrs the starting point complete.
Returning/Filling in trenches in layer n exc 25 cm thick including watering well ramming etc.
M & L for Hard core of broken stone or boulders 150 mm thick spread thickness of gauge n. Exc 63mm deposited spread and levelled in layers n. exc 15 cm thick watered and rammed to a true surface
M&L for 150 mm thick cement concrete in sub base of floor in cement mortar (1:3:6) type C-2
M&L for 100 mm thick cement concrete 1:2:4 type B 2 using 40mm graded stone aggregate as in sub base of foooing complete all as specified and directed..
Forming 12mm thick expansion joints for 150mm thick concrete slab filled with pre-formed bituminous filler and top 30 mm primed and sealed with sealing compound, Grade'A'.
Surface dressing n.exc 15 cm deep in soft/loose soil complete all as specified and directed.
M&L for RCC M-25(Design Mix) ( 20 mm graded agg) as in foundation, base for column , plinth beam etc complete all as specified and directed
M&L for RCC M-25(Design Mix) ( 20 mm graded agg) as in column, post etc complete all as specified and directed
M&L for RCC M-25(Design Mix) ( 20 mm graded agg) as in roof slab supported on wall, beam, landing, desk slab etc complete all as specified and directed
M&L for RCC M-25(Design Mix) (20mm gradded agg) as Lintel/chajja etc complete all as specified and directed
M&L for RCC M-25(Design Mix) (20mm gradded agg) as Beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
Use & waste of form work to the side of the concrete foundation, footing, base of column rough finished flat surface.
Use & waste of form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick ( Horizontal or sloping) of rough finished flat concrete surfaces
Use & waste of form work to the side of the column , rough finished flat surface area.
Use & waste of formwork to side and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, verhangs etc also plays between floors and beams etc.
Use & waste of form work to edge of concrete flats, breks in flooors, openings in concrete walls , floors and roofs and sides of RCC/PCC bands in walls, horizontal or loppin and similar work all exceeding 20 cm wide(Where RCC/PCC band in walls spanning and opening , the formwork soffit only shall be paid for under item 7010 of SSR Part-II
M&L brick work using sub class ‘B’ bricks (old size) straight or curved on plan to any radius in half brick work built in CM 1:4 complete all as specified.
M&L 15 mm thick plastering on other than fair faces of wall surfaces in cm (1:6) complete all as specified and directed
M&L 5 mm thick plastering on ceilling concrete surface in cm (1:3) even and smooth w/o using extra cement.
M&L for sand filling under floor or in foundation incl watering as reqd.
M&L for 75 mm thick cement concrete in sub base of floor in cement mortar (1:3:6) type C-2
M&L for Polythene film,150 micron thick, laid on a coat of bitumen primer, @ 0.30 to .50 kg per sq. m
M&L for rendering 20mm thick in cement mortar 1:4 in two layers of 10mm each using WPC in finishing layer on brick or concrete surfaces finished even & smooth ( WPC for finishing layer will be measured and paid seperately as supply only).
Supply only integral water proofing compound.
15 mm thick screed bed or bedding layer of mortar in CM 1:6 fixing of tiles in floor.
M&L 10 mm thick rendering in CM 1:4 on brick or concrete surfaces for fixing of tiles in wall.
M & L for Non - skid Ceramic tiles (joint free, coloured) 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed
M & L for non skid ceramic coloured tiles 300x300x7 to 8 mm thick in floors set and jointed in neat cement slurry and pointed with whie/coloured cement to match
S&F for colour Glazed ceramic tiles 450x350mm of 7 to 8mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Forming Constrution (Dummy) joints 30 mm deep x 10 mm wide, filled with sealing compound grade A
M&L for preparation of new plastered surface of ceiling and applying three coats of white wash
M&L applying two coats of oil bounded distemper over a 3mm thick wall care putty on walls complete all as directed
M&L for preparation of new plastered surface of wall and applying three coats of white wash
S&F MS Hold fast confirming to Fe-290 Gde E-165
M&L PCC (1:3:6) type C-1 as in bed block of hold fast using 20 mm stone agg steps etc.
S&F Steel window side hung shutters including box type hinges with steel handle and steel pegs stay complete with glazing bars and fly proofing completed.
S & F 3mm thick figured glass n exc 0.5 sqm in each pane glazing with oil putty complete
M&L for two coats of synthetic enamel painting to new wooden surfaces over a coat of pink primer including preparation of surfaces area exc 10cm width & girth.
S&F 3 mm thick ordinary quality sheet glass in squares n exc 0.5 sqm in each pane glazing with oil putty complete.
M&L for galvanised mild steel wire cloth of 0.56mm dia and average aparure of 1.4mm and fixed in position
S & F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified, supplied and fixed
S&F 2nd class hard wood shutter 35mm thick plain framed, panalled shutter (two panel) with lock rail and panel of 9mm B.W.P commercial ply or 12mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part-I), kiln seasoned and chemically pressure treated.
S&F 35mm thick glazed and skeleton shutters open rebated and prepared to receive glass gauge etc. Divided into squares with plain chamfered or rounded, rebated sash bars, sizes of the members of the shutters as specified in SSR Part I, section 8, clause 8.23(a).
S & F Factory made solid panel pvc door shutter with chowkhats 30mm thick (style) consisting of frame made out of M.S.tubes for top & bottom rails.M.S.frame shall be covered with heat moulded plain colour PVC "C" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S.frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined to gether with solvent cement, suppling & fixing in the frame at site as per specification & drawing.
S & F PVC door with chowkhats frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, supply & fixing in opening as per specification & drawing.
S & F vitreous china white wash hand basin flat back of size 550 x 400 mm including brackets CP waste coupling 32 mm and PVC waste pipe and 15mm PVC connection complete.
S & F for 20 mm stop valves, cast copper alloy screwed down high pressure with crutch 01 butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed
S & F 15 mm stop valves, fancy type chromium plated for iron or for unions and fixed in position
S&F 15mm bore fancy type chromium plated bib tap with crutch or butterfly handle screwed down for iron pipes.
S&F 15mm bore 125mm size type brass chromium plated shower rose, complete all as specified.
S & F 15 mmdia pillar tap, cast copper alloy with capstan heads, fancy tube, chromium plated, screwed down high pressure, with long screwed shanks and fly nuts, screwed for iron pipe and fixed complete all as specified and directed
S&F 500 Ltrs capacity rotational moulded polythene water storage tank (cylindrical vertical with closed top) hoisted and fixed in position
S&F ball brass valve high pressure with polythene float & flynut screwed for iron pipe and fixed of size 20mm bore complete all as directed at site.
S&F 15mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors
S&F 20mm bore medium grade galvanished tube with all fitting & fixed complete to walls or ceiling & laid in floors
S&F 300 mm Aluminium alloy anodised sliding door bolt, plate type and fixing clip of sheet cast of extruded section and fixing bolt and sliding bolt of extruded section and fixed in position complete
S&F 200 mm aluminium anodised barrel tower bolt, of extruded section and fixed in position
M&L for extruded aluminium alloy handle fabricated type of 150 mm long
M&L for extruded aluminium alloy handle fabricated type of 100 mm long
S&F 125 mm aluminium anodised barrel tower bolt, of extruded section and fixed in position
S&F 100 mm Butt hinges medium weight cold rolled mild steel and fixed.
S&F 75 mm Butt hinges medium weight cold rolled mild steel and fixed.
S& F 110 mm dia PVC (SWR) bends any radius fixed in any position, complete all as specified and directed
S& F 110 mm dia PVC (SWR) junction single 'T' equal or unequal fixed in any position, complete all as specified and directed
S& F 75 mm dia PVC pipes single socketed in any length with rubber ring joints, laid in trenches/floors or fixed to wall complete all as specified and directed
S& F 110 mm dia PVC pipes single socketed in any length with rubber ring joints, laid in trenches/floors or fixed to wall complete all as specified and directed
S/F 110 mm bore PVC (SWR) vent Cowl.
S & F connection 15 mm size with PTMT nuts of length 450 mm complete all as specified and directed
M&L High density polyethylene pipes(HDPE) of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc.
S & F vitreous china squatting pan, 'Orissa' pattern, size 580 x 440mm white, with integral foot rests,including trap set in and including concrete, connection to trap, and to flushing pipe, anti-syphonic pipe, etc complete including making good of floor (Excluding fixing bolts, flushing cistern and flush pipe).
S & F PVC valveless, syphonic action type, flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets , long bend including flush pipe of PVC 32mm dia and connection to pipes etc complete all as specified and directed .
S & F Towel Rail 600mm long of PTMT fixed with and including Chromium plated brass screws and wooden/plastic cleats. (Minimum weight 190gms)
M&L providing pre-cast RCC 1:2:4 type B-1 using 20mm graded stone aggregate as in manhole cover slabs, set in cm 1:4 including necessary form work complete all as specified and directed by the Engineer-in-Charge
Preparation of concrete roof surfaces applying roof treatment as under:-(a) Applying bitumineous primer @ 0.30 litre per Sqm of surface (Shalitex Primer of STP Limited or equivalent as approved by GE (b) Applying coat of hot applied bitumen 85/25 @ 1.20 Kg/Sq m of surfaces (Make : STP Ltd or equivalent as approved by GE) (c) Laying of APP Modified water proofing membrance with non-woven polyster Reinforcement on hot applied bitumen with 100mm over lap at joints by torching on the transverse direction and 75 mm on longitudinal directional all as per manufacturer's instructions (Make : SUPER THERMOLAY OF STP LTD OR EQUIVALENT IWL/TEXSA) (d) Applying a coat of bitumineous aluminium paint @ 0.10 litre/SM (Super Silver sheild of STP Ltd or equivalent as approved by GE)
M&L for 15 mm thick screed bed in cm 1:3 mixed with WPC as per manufactures instruction finished even and smooth over RCC roof slab without using extra cement (WPC shall be measured seperately)
S&F Floor door stopper of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor overall length 140mm complete all as specified
S&F for MS 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified
S &F chequered cement concrete coloured tiles (glossy finish) 20cm x 20cm x 25 mm thick set, jointed and pointed in neat cement slurry with grey cement and pigment complete all as specified and directed.
Excavation over area n exc 1.50 mtr in depth and getting out in hard/dense soil complete all as specified and directed
M&L for PCC 1:2:4 type B1 using 20 mm graded aggregate as in concrete bed to septic tank
M&L for Brickwork, with subclass ‘B’ bricks in one brick thick honey comb work, built in CM(1:4) complete all as directed.
M&L for RCC (1:2:4) type BI (using 20mm graded stone aggt) as in precast slab set in CM (1:4).
M&L 10mm dia and over MS Round bar cut to length bent to shape required, including cranking, bending for Rungs.
M&L Loose filling with broken bricks aggregates of gauge 80 to 150 mm in soakage pits, soakage wells complete all as directed
M&L for supply, laying, jointing and testing salt glazed stone ware drain pipe, grade 'A' 150mm bore (internal dia) laid in trenches on concrete bed to required slope jointed and tested complete all as specified and directed by the Engineer-in-Charge. (Note:- Excavation/earth work and concrete bed shall be measured and paid for separately)
M&L plain cement Concrete 1:3:6 type C2(Using 40mm graded agg) for concrete bed to drain pipes of 150mm bore, under and haunching against the sides of pipes after they are laid and tested in complete all as specified and directed by Engineer-in-Charge
Supply and fixing Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium non integral IP66 highbay light fitting 180 Watt suitable for high mast application, highlighting architectural facade and general purpose complete all as specified and directed.
S&F 1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 4 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire complete all as specified and directed.
S&F 1100 Volts grade heavy duty cable PVC insulated standred twin core flat or circular aluminium conductor of size 10 Sqmm, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm suspension wire complete all as specified and directed.
Supply and fix SPN double door MCB distribution board sheet steel, powder coated 6 way fitted with bus bar Neutral link, earth bar and din rail complete all as directed.
S & F MCB SPN 240 Volts, 6-32 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
S & F MCB SP 6-32 Amps, 240 V, 50 HZ,breaking capacity 10KA, C series all as specified and directed.
Material and labour for sub main wiring complete with two runs of 6.0 sqmm single core FRLS grade PVC insulated unsheathed cable 1100 volt grade multistranded copper conductor drawn in and including PVC concealed conduit of suitable size(not less than 20 mm width/bore) and accessories surface on wall, roofs etc with two run of PVC insulated copper conductor 6 sqmm single core as earth continuity conductor connected with earth dolly and mains all as specified . (Note;- (i) 2 runs of 6 sqmm cable and 1 run of 4 sqmm single core copper cable and 1 run of non metalic PVC conduit shall be measured as single run. (ii) Cost of cutting chases shall deemed to be included in unit rate.)
M & L for point wiring with 1.5 Sq mm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLSH cable 1100 votls grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal box fixed with brass screws complete for housing the switches, socket outlets, fan regulators etc. for the following (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
(a) one light/fan point controlled by one, one way switch.
(b) one socket outlet 5 pin 6 amps on independent board.
(c) one 5 amps socket outlet on same board with other switch.
M & L for point wiring with 2.5 Sq mm (nominal area) PVC insulated and unsheathed single core FRLSH copper cable 1100 volts grade with multi-stranded copper conductor in and including PVC concealed conduit and conduit accessories alongwith continuous earth wire 1.5 Sq mm PVC insulated and unsheathed single core FRLSH cable 1100 votls grade with stranded copper conductor and connected to common earth dolly, with and including 1.6 mm thick cadmium plated sunk MS pressed steel terminal box fixed with brass screws complete for one socket outlet 6 pin 15/16 amps on independent board (Rate deemed to be inclusive of cutting chases and making good disturbed surface).
Supply and fix Modular switch one way 6 Amp.
Supply and fix modular socket outlet 2 in 1, 3 pin 6 A.
Material and labour for ceiling rose polycarbonate isolated body 3 ways terminals.
Supply and fix modular type electronic fan regulator.
Supply and fix switch outlet 6 pin,16 Amps
Supply and fix Socket 6A/16A - 2in 1, 3 pin combined 2 module,
Supply and fixing modular white cover plate with frame 1 modules complete all as specified and as directed. Make: Havells/Anchor or equivalent make as approved by GE.
Supply and fixing modular white cover plate with frame 3 modules complete all as specified and as directed. Make: Havells/Anchor or equivalent make as approved by GE.
Supply and fixing modular white cover plate with frame 6 modules complete all as specified and as directed. Make: Havells/Anchor or equivalent make as approved by GE.
Supply and fixing modular white cover plate with frame 12 modules complete all as specified and as directed. Make: Havells/Anchor or equivalent make as approved by GE.
Supply and fixing in replacement of wall mounted LED fitting 20 watts making all connection to ceiling rose complete all as specified and directed.
Supply and fix in replacement of SPN double door MCB distribution board sheet steel, powder coated 8 way fitted with bus bar Neutral link, earth bar and din rail complete all as directed.
S & F in replcement of MCB SPN 240 Volts, 50-63 Amps, 50 Hz, breaking capacity 10KA, C series all as specified and directed
Supply, install, testing and commissioning of ceiling fan 1200 mm sweep complete all as specified and directed. Make :Havells Model Spark Deco or equivalent in crampton, Bajaj
Supply and fix exahust fan Single phase 230/240 V of size 300 mm sweep metal body heavy duty turbo HHDEF 900 RPM all as specified and directed.
Supply and fix energy efficient 5 star rating electrical geyser, 25 liters capacity along with inlet outlet hot & cold water connection pipe complete all as directed.
M & L for earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25m deep below ground level ) with top edge of the plate not less than 1.5 m below normal ground level , connected to galvanised earth lead iron wire 4mm dia by means of GI bolts nuts and washers of galvanised iron or steel etc all as shown in electrical plate No.3 including earth work PCC pit and RCC pit cover, funnel with watering pipe ,wire mesh ,alternate layer of salt and charcoal, GI protection pipe light grade and testing on completion all as specified and directed by Engr-in-charge.
Excavation in post holes (or similar holes) each n exc 0.5 Cum getting out , returning , filling in and ramming earth or broken rubble mixed with earth around in layers not exceeding 25 cm.
M & L for 75 mm thick PCC (1:4:8) type C-2 using 40mm graded aggregate as in sub base of hardstanding/footpath
M&L for 100mm thick .Cement Concrete 1:2:4 type B2 using 40mm graded aggtregate as in floor finshed even and smooth without using extra cement including filling of construction joint with Cm(1:6) complete all as directed.
M& L for R C C 1:1.5:3 (,20mm gradded agg) as Lintel/chajja etc.
M & L flat formwork to chullah hoods, chajjas, troughs and similar items including edges complete all as directed.
S&F for colour Glazed ceramic tiles 350x250mm of 7 to 8mm thick, in dado/skirting set and jointed in neat cement slurry and pointed in white or coloured cement to match.
Supply and fix Plate rack made out of Stainless steel sheet 0.5 thick overall size 800(H)x800(W)x3000(D) including brackets or fitted with existing shelves in repair complete all as specified and directed
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core complete all as speified.
Supply and fix GI pipe of dia 32mm to wall/Pole of light grade with required clamping arrangements to fix with the pole complete and connecting to the existing pipe line all as specified Make : JINDAL/TATA
S&F steel tubes medium grade galvanised 25 mm bore with all fittings laid in trenches complete all as directed.
S&F Gun-metal, globe or gate valves,with iron wheel head, screwed both ends for iron pipe and fixed 25 mm bore complete all as specified and directed. Note:-The contract sum shall be arrieved at after deducting amount of schedule of credit from the total quated amount.
M/S SEWAK SINGH
Chinmay Traders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .