| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.7 LAccepted-AOC WZ 409 0 B 1ST FLOOR PLOT NO 12 JANAK PARK HARI NAGAR NEW DELHI 110064 | NEW DELHI | WEST DELHI | DELHI | 110064 | L1 | Accepted-AOC L1 | |
| 2 | L2₹25.4 L+₹96,683 (3.96%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹26.8 L+₹2.4 L (9.72%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹28.1 L+₹3.7 L (15.1%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
Refer Docs
EMD Value
₹58,000
Closing Date
1 Mar 2021, 6:00 pmClosed
CWE AF Borjhar
Commander Works Engineers AF Military Engineer Services Borjhar PO Borjhar Airport Guwahati 15 Assam Pin 781015 Tele 0361 2841626
REPAIR MAINT OF AC PLANT OF VARIOUS CAPACITY AND OTHER CONNECTED MISC WORKS AT AFS TEZPUR
2021_MES_416049_1
CWE (AF)/TEZ/TOKEN-45 OF 2020-21
Open Tender
Electrical and Maintenance Works
Works
365 days
Tezpur
As per tender documents
8 documents required · 8 mandatory
₹500
GE AF Tezpur
₹58,000
Yes
9 Apr 2021
25 Jan 2021
3 Mar 2021
25 Jan 2021
1 Mar 2021
9 Feb 2021
Amount
Complete overhauling & servicing of existing Package Type A C Plants of capacity 8.75 TR x2,Air cooled type for Parachute Bldg complete including cleaning of prefilters, condensor cleaning with coil cleaner, cleaning of all dampers for optimum cooling in every room, duct inspection and cleaning from inside, checking and rectification of control wiring (cost of control wiring included), greasing of blower motor, checking of all safety measures, topping of gas and compressor oil, balancing of blower etc by trained and qualified Mechanics of (OEM) including replacement of unserviceable Spare parts, leak test by nitrogen gas and charging the refrigerant as required at site & including testing with test run for 24 hrs to achieve satisfactory service and designed condition in presence of Engr-in-Charge complete all as specified and directed. (Make of AC Plant : Blue Star)
Description all as per item No 1 above but capacity of AC Plant 5.5 TR X 3, Air-Cooled type for Transmitter Bldg. (Make of AC Plant : Blue Star)
Description all as per item No 1 above but of capacity of AC Plant 11 TR X 3, Air-Cooled type for PTT Simulator Bldg. (Make of AC Plant : Blue Star)
Description all as per item No 1 above but of capacity of AC Plant 11 TR X 3, Air-Cooled type for Base Opss Bldg. (Make of AC Plant : Blue Star)
Description all as per item No 1 above but of capacity of AC Plant 16.5 TR X 6, Air-Cooled type for 267 SU (MPR) Bldg. (Make of AC Plant : Blue Star) Note for Item nos 1 to 5 :- (i) Nitrogen gas required for the above AC Plants are deemed to be included in the unit rate quoted. (ii) Supply only Spare Parts required for theabove AC Plants shall be measured and paid separately under relevant Items Nos 6 to 15.
Supply Only Liquid Line Gas Filter of Size 5/8".
Supply Only Charging Valve 1/4".
Supply Only R - 22 refrigant gas.
Supply Only R - 407 refrigant gas.
Supply Only Three Phase Contactor 8-16 Amp rating.
Supply Only Air filters 20 microns with MS/PVC frame and washable PVC filter suitable for package type AC plant of cap 8.75 / 10/ 5.5 TR .
Supply Only Liquid line valve 5/8"
Supply Only Fan blade suitale for blower motor of cap 1HP for outdoor unit.
Supply Only Connector assembly 4 pole suitable for control panel of AC plant, 3 phase, 440V
Supply Only Indoor unit blower motor bearing for motor of cap 2HP
Supply and fix as in repair blower motor cap 1 HP 1420 RPM 50Hz Single phase for package type AC plant capacity as per existing size. ( For outdoor unit) complete all as specified and directed.
Taking out unserviceable and burnt out blower motor of capacity 2 HP ,1420 RPM ,50 Haz, strip opening and removing complete winding wire and rewinding with required gauge of super enamelled copper winding wire including insulating ,varnishing ,baking to the required temprature including testing, complete all as specified and directed.
Supply and fix in repair Power Contactor of rating 9 to 18 Amps including NO/NC auxiliary contacts, complete all as specified and directed.
Supply and fix in repair Power contactor of rating 32 amps incl NO/NC auxillary contacts, complete all as specified and directed.
Supply and fix in repair Single phase preventor VSP-2/3, complete all as specified and directed.
Supply and fix in repair Digital type 3 phase ammeter 0-100A rating flush mounting of size 96mm x 96mm, complete all as specified and directed.
Supply and fix in repair Digital type voltmeter 0-500 V, 96mm x 96mm, complete all as specified and directed.
Supply and fix in repair Analogue type 3 phase ammeter 0-100A rating flush mounting of size 96mm x 96mm, complete all as specified and directed.
Supply and fixing in repair Analogue type voltmeter 0-500 V, 96mm x 96mm complete all as specified and directed.
Supply and fixing in repair LED indicator lamp RYB complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole 63 Amps with fixed thermal magnetic release and breaking capacity 16KA complete all as specified and directed.
Supply and fixing in repair MCCB 4 pole 100 Amps with fixed thermal magnetic release and breaking capacity 25KA complete all as specified and directed.
Supply and fixing in repair Thermal overload relay for relay range between 0.2 to 16 Amps complete all as specified and directed.
Supply and fixing in repair MCB TPN 63 Amps , C curve complete all as specified and directed.
Supply and fixing in repair MCB TP 6-32 Amps , C curve complete all as specified and directed.
Supply and fixing in repair MCB TPN 6-32 Amps , C curve complete all as specified and directed.
Supply and fixing in repair MCB SP 6-32 Amps , C curve complete all as specified and directed.
Replacement of all worn out wiring of LT panel and rewiring with suitable size single core PVC insulated, unsheathed multi stranded 1100 volts grade copper conductor cable of required sizes from bus bar to outgoing feeders/ starters, properly lugged at end terminals , cleaning of panel board , tightening of all connections including replacement of worn out lugs etc complete all as specified and directed.
Supply and fixing in repair strip heater of capacity 3KW including removal of existing unserviceable heater complete all as specified and directed. Make Dasspass or its equivalent approved make.
Supply, Laying, testing & commissioning in replacement of XLPE insulated, unarmoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectionalarea 16 Sqmm 4 core laid in duct, or fixed on walls/poles complete all as specified and directed.
Supply, Laying, testing & commissioning in replacement of XLPE insulated, unarmoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross- sectionalarea 25 Sqmm 4 core laid in duct, or fixed on walls/poles complete all as specified and directed.
Supply only digital hygro thermometer for monitoring temperature & humidity at AC plants.
De-Scaling of Condensers of AC Plant complete unit of capacity 7.5 TRX 3 Units installed at (DB-6) by using dilute de-scaling agents, filling it for 24 Hours, removing the de-scalings by Mechanical wire brush after opening the side plates,cleaning thoroughly including replacement of gaskets, refixing the end plates of plant complete all as specified and directed.
Description all as per srl item No 38 above but air-Conditioning Plant complete unit of capacity 15 TRX3 Units Installed at WWR Building.
Description all as per srl item No 38 above but air-Conditioning Plant complete unit of capacity 26 TRX 3 Units Installed at SC.
Description all as per srl item No 38 above but air-Conditioning Plant complete unit of capacity 26 TRX 2 Units Installed at CRRW.
Description all as per srl item No 38 above but air-Conditioning Plant complete unit of capacity 26 TRX 2 Units Installed at V K Hall.
Overhauling of complete Compressor unit of Capacity 7.5 TR installed at (DB-6) after disconnecting all mechanical and Electrical connections, removing from foundation complete including replacement of suction reed, discharge reed, connecting rod, crank shaft, piston and Piston rings, oil Pump assembly, bearings, Oil seal, replacement of compressor Oil, Gaskets Including charging of Compressor oil upto the required level including testing complete all as specified and as directed. Note for item No 43 to 47 :- Supply only Spare parts shall be measured and paid separately under respective items of this Schedule .
Overhauling of complete Compressor of Capacity 15 TR installed at WWR Building after disconnecting all mechanical and Electrical connections, removing from foundation complete including replacement of suction reed, discharge reed, connecting rod, crank shaft, piston and Piston rings, oil Pump assembly, bearings, Oil Seal, replacement of compressor Oil, Gaskets Including Compressor oil charge including testing complete all as specified and as directed.
Overhauling of Air-Handling Unit of AC Plant of capacity 15 TR installed at WSA Bldg including coil changing, cleaning of AHU drain, replacement of hessian cloth with chain, heat vernishing, baking, connecting plates, checking of all electrical connections (removing of any carbon deposits), pre-filter and micro filter cleaning & greasing of all rotary bearings all complete including testing complete as specified and as directed.
Description all as per srl item No 45 above of capacity 30 TR installed at WWR Bldg.
Description all as per srl item No 45 above of capacity 26 TR installed at CRRW Bldg.
Overhauling of Air-Handling Unit of AC Plant of capacity 52 TR installed at Signal Centre including coil changing, cleaning of AHU drain, replacement of hessian cloth with chain, heat varnishing, baking connecting plates, checking of all electrical connections (removing of any carbon deposits), pre-filter and micro filter cleaning & greasing of all rotary bearings including testing complete all as specified and as directed. Note :- Supply only Spare parts shall be measured and paid separately under respective item of this Schedule .
Overhauling of Air-Handling Unit of AC Plant of capacity 52 TR installed at VK Hall including coil changing, cleaning of AHU drain, replacement of hessian cloth with chain, heat vernishing, baking, connecting plates, checking of all electrical connections (removing of any carbon deposits), pre-filter and micro filrter cleaning & greasing of all rotary bearings including testing complete all as specified and as directed. Note :- Supply only Spare parts shall be measured and paid separately under respective item of this Schedule.
Overhauling of Air-Handling Unit of AC Plant of capacity 66 TR x 4 Nos installed at Annx I & II Service Bldg including coil changing, cleaning of AHU drain, replacement of hessian cloth with chain, heat varnishing, baking connecting plates, checking of all electrical connections (removing of any carbon deposits), pre-filter and micro filter cleaning & greasing of all rotary bearings including testing complete all as specified and as directed. Note :- Supply only Spare parts shall be measured and paid separately under respective item of this Schedule.
Overhauling of Air-Handling Unit of AC Plant of capacity 75 TR x 2 Nos installed at Annx III Service Bldg including coil changing, cleaning of AHU drain, replacement of hessian cloth with chain, heat varnishing, baking connecting plates, checking of all electrical connections (removing of any carbon deposits), pre-filter and micro filter cleaning & greasing of all rotary bearings including testing complete all as specified and as directed. Note :- Supply only Spare parts shall be measured and paid separately under respective item of this Schedule.
Supply only suitable thermostate for AC Plant.
Supply only suitable humidistate for AC Plant.
Supply only suitable AHU ball bearing.
Supply only suitable AHU V-Belt of any size.
Supply only suitable canvas cloth of any size.
Disconnecting unservicable condenser/Chiller/Hot water generator pump of capacity 3 HP (3 Phase), transporting to local workshop for checking, segregating serviceable and unserviceable parts, cleaning the serviceable parts thoroughly by approved method (Parts like stator, rotor, terminal box, bearings shaft, key etc) and replacing the unserviceable parts and refixing the same to original position including testing on full load complete all as specified and directed. Note :- Supply only Spares parts shall be measured and paid separately under respective item of this sch .
Description all as per items No. 57 here-in-before but pump of capacity 5 HP (3 Phase).
Description all as per items No 57 here-in-before but pump of capacity 7.5 HP (3 Phase).
Description all as per items No 57 here-in-before but pump of capacity 20 HP (3 Phase).
Description all as per items No 57 here-in-before but pump of capacity 25 HP (3 Phase).
Supply only ball bearing size 6205 ZZ to 6209 ZZ.
Supply only ball bearing size 6210 ZZ to 6213 ZZ.
Supply only ball bearing size 6305 ZZ to 6309 ZZ.
Supply only ball bearing size 6310 ZZ to 6313 ZZ.
Supply only impeller of pump (material GM/cast iron/bronze according to the existing material) suitable for pump of capacity up to 7.5 HP.
Supply only impeller of pump (material GM/cast iron/bronze according to the existing material) suitable for pump of capacity of 20 HP.
Supply only suitable pump mechanical seal set upto 7.5 HP.
Supply only oil seal, lock nut & lock washer set upto 7.5 HP.
Supply only oil seal, lock nut & lock washer set of 20 HP.
Supply only suitable coupling with rocker assembly 7.5 HP to 20 HP.
Supply only gland packing.
Taking down unserviceable shaft from various type /capacity of pump set/ motor/ monoblock and welding / spraying & turning of shaft to lathe machine fitted to bearing and testing to the entire satisfaction of engr in charge.
Disconnecting unservicable water motor of capacity 1.5 HP, transporting to local workshop for rewinding by cutting, removing unservicable burnt winding wire and rewinding starter of the same with original gauge of copper winding wire, varnishing, insulating, refixing the same with pump assembly including testing on full load complete all as specified and as directed. Note :- Supply only spare parts shall be measured and paid separately under respective item of this schedule.
Disconnecting unservicable condensor/Chiller/Hot water motor 3 HP, transporting to local workshop for rewinding by cutting, removing u/s burnt winding wire and rewinding stator of the same with original gauge of copper winding wire, varnishing, insulating, refixing the same with pump assembly, replacing of bearings including testing on full load complete all as specified and as directed. Note :- Supply only spares parts shall be measured and paid separately under respective item of this schedule .
Description all as per items No 74 here-in-before but motor of capacity 5 HP 3 Ph.
Description all as per items No 74 here-in-before but motor of capacity 7.5 HP 3 Ph.
Description all as per items No 74 here-in-before but motor of capacity 20 HP 3 Ph.
Description all as per items No 74 here-in-before but motor of capacity 25 HP 3 Ph.
Supply only various size/ capacity of electrical terminal including terminal plate for monoblock/ motor/ pump motor.
Supply only cooling fan vanes of different size of motor.
Material and Labour for carrying out the Leak test by nitrogen gas filling for desired pressure, testing for 24 hrs, arresting the leakages, removing the entire Nitrogen gas after testing, evacuating the system by vaccum Pump and charging the new refrigerant to the entire capacity of 15 TR plant for smooth functioning at WSA AC Plant complete all as specified and directed.Note: Supply only new gas for charging will be measured and paid separately under relevant items.
Description all as per item No. 82 above but for plant at WWR of capacity 30 TR.
Description all as per item No 82 above but for plant at CRRW of capacity 26 TR.
Description all as per item No 82 above but for plant at Signal Section of capacity 26 TR.
Description all as per item No 82 above but for plant at Akash of capacity 80 TR.
Description all as per item No 82 above but for plant at VK Hall of capacity 26 TR.
Description all as per item No 82 above but for plant at Annx I & II of capacity 66 TR.
Description all as per item No 82 above but for plant at Annx III of capacity 75TR.
Description all as per item No 82 above but for plant at New Tech Flight of capacity 80 TR.
Painting with recommended method to Air-Conditioning Plant machinaries, Motors, Condensers, Pipe Lines ,pumps,air handling unit, etc. all as per the colour code with enamel paint for AC plant of capacity 26 TR X 2 (DB6) after preparation of surfaces by dusting/ dirting at complete all as specified and directed.
Description all as per item No 91 above but for plant of capacity 66 TR X 2 (Annx - I & II) (WWR).
Description all as per item No 91 above but for plant of capacity 75 TR X 2 (Annx - III) (CRRW).
Description all as per item No 91 above but for plant of capacity 80 TR X 3 ( Signal Sec).
Supply and fix in repair Pressure gauge round shape for discharge line (0-300 PSI).
Supply and fix in repair Pressure gauge round shape for liquid line (0-150PSI).
Supply and fix in repair Water Temprature Thermometer Round type 100 mm dia 0-100 Degree centigrade.
Supply and fix in repair Water flow switch.
Supply and fix in repair Water Pressure gauge round type 100 mm dia 0-150 psi.
Supply and fix in repair V Belt B-68.
Supply and fix in repair V Belt A - 32.
Supply and fix in repair V Belt B-112.
Supply and fix in repair V Belt B - 72.
Supply and fix in repair Oil Pressure Gauge.
Supply and fix in repair Fan blade suitale for blower motor of cap 3 HP for outdoor unit.
Supply and fix in repair Solonoid Valve size 1/4" 5.5 TR to 7.5 TR.
Supply and fix in repair Solonoid Valve size 1/4" 15 TR to 80 TR.
Supply and fix in repair Safety Valve 350 PSI -discharge line.
Supply and fix in repair Three Phase Contractor ML - 2.
Taking out unserviceable and worn out blower motor of capacity 3 HP, 2800 RPM , 50 Haz, strip opening and removing complete winding and rewinding with existing gauge of super enamelled copper winding wire including insulating ,varnishing ,baking to the required temprature including testing complete all as directed and specified.
Supply and fix in repair new Power Circuit Board 5.5/8.75/11TR (Air cooled AC Plant).
Supply and fix in repair LWT / HWT Sensor for 26 TR .
Supply and fix in repair LWT / HWT Sensor 52 TR to 80 TR .
Supply & fixing of cooling tower sprinkler assy with Gear box, driver shaft, FRP fan suitable to motor assembly, base, bearings and arms stay supports etc suitable for 52 TR AC plant,including taking down unserviciable sprinkler assy, complete all as specified and as directed.
Maintenance ,overhauling and servicing central type water cooled AC plant of capacity 80 x 3TR and descaling of AHU,cleaning of all AHU Filters, descaling of air cooled condenser unit with appropriate cleaning agent,soap wash and by using dilute de-scaling agents, removing the de-scalings by pump & motor mechanism and cleaning agent including leakage testing of seal system by nitrogen pressure and vaccuming for 24 hour and descaling of Chiller Condensers unit, maintenance of blower motor unit and maintenance of referigerant gas filter and water pipe line valve including testing complete all as specified and as directed. Note (i) Overhauling / Maintenance / Servicing shall be carried out through trained and qualified employees of (OEM)
Maintenance ,overhauling and servicing central type water cooled AC plant of capacity 80 X 3 TR and descaling of AHU,cleaning of all AHU Filters, descaling of condensor unit, descaling of cooling tower with appropriate cleaning agent,soap wash and by using dilute de-scaling agents, removing the de-scalings by pump & motor mechanism and cleaning agent including leakage testing of seal system by nitrogen pressure and vaccuming for 24 hour and descaling of Chiller Condensers unit, maintenance of blower motor unit and maintenance of referigerant gas filter and water pipe line valve including testing complete all as specified and as directed. Note (i) trained and qualified employees of (OEM) :For New Tech Flight
Supply and fixing strip heater of Capacity 25 KW including removal of existing unserviceable heater complete all as specified and directed.Make Dasspass or its equivalent approved make
Maintenance of Hot water system, heating element complete all as specified and as directed Note :- trained and qualified employees of (OEM): Note. Replacement of heating element will be measured and paid seprately under relevant item.
Material and labour for Gas Charging(R-22) of AC plant 80 x3 TR AC Plant.
Material and labour for Gas Charging(R-134a) of AC plant 80 x3 TR AC Plant. For New Tech Flt & Annx I & II & Annx III ).
Overhauling of Chiller Condensers unit of capacity 80 TR installed at AM AC Plant by using dilute de-scaling agents, removing the de-scalings by pump & motor mechanism and cleaning agent including leakage testing of seal system by nitrogen pressure and vaccuming for 24 hours and make ready for gas charging including testing complete all as specified and directed.
Supply and Fix in repair scroll type sealed compressor of capacity 13 TR with all accessories fixing of base mounting accessories liquid line and discharge line valve and safety valve including gas charging and oil charging and make good for satisfactory cooling effect including testing complete all as specified and directed. Note. Old unserviceable compressor will be deposited to AGE E/M store yard.
Material and labour for repair /cleaning of cooling tower 7.5 TR( DB-6) FRP type including draining out water from bottom tray ,descaling with hydrochloric acid,including brushing bottom tray and honey comb fins by disconnecting and refixing complete for silt free / algea free and replacement of unservicable float valve and unservicable pvc nozzles for complete fins bottom tray all as directed.
Description a as per item No 123 above but of Cap 15TR (WWR).
Description a as per item No 123 above but of Cap 26 TR (Signal Sec & CRRW).
Supply and fixing as in repair Air filters 20 microns with MS/PVC frame and washable PVC filter suitable for Central type AC plant of cap 15 TR .( For DB-6/WWR)
Supply and charging Compressor (capillary) oil grade B-63.
Supply and fixing in repair 25 mm bore galvanized steel tubing, medium grade used for watering purpose in cooling tower/overhead tanks in AC plants including required joints/welding including necessary fitting as per site requirement complete all as specified and directed.
Supply and fixing in repair 32 mm bore galvanized steel tubing, medium grade used in AC plants including required joints/welding including necessary fitting as per site requirement complete all as specified and directed.
Supply and fixing as in repair 40 mm bore galvanized steel tubing, medium grade used in AC plants including required joints/welding including necessary fitting as per site requirement complete all as specified and directed.
Supply and fixing in repair 25 mm dia gate valve heavy duty, ISI marked complete all as specified and directed.
Supply and fixing in repair suitable oil heater for screw compressor complete all as specified and directed.
Supply and fixing in repair Oil filter kit for Chiller Model KAS 070.14.
Supply and charging Lube oil (FC170) for Chiller Model KAS 070.14.
Supply and fixing in repair Drier core filter kit for Chiller Model KAS 070.14.
Supply and fixing in repair Gasket Filter drier top flange kit for Chiller Model KAS 070.14.
Supply and fixing in repair PGD 120X32 Display for Chiller Model KAS 070.14.
Supply and fixing in repair pressure transducer 44.8 bar for Chiller Model KAS 070.14.
Supply and fixing in repair pressure transducer 10 bar for Chiller Model KAS 070.14.
Supply and fixing in repair pressure transducer cable for Chiller Model KAS 070.14.
Supply and fixing in repair crank case heater for Chiller Model KAS 070.14.
Supply and fixing in repair CT card AC to DC convertor for Chiller Model KAS 070.14.
Supply and fixing in repair Expansion model K-smart controller for Chiller Model KAS 070.14.
Supply and fixing in repair Current transformer 100/0.2A for Chiller Model KAS 070.14.
Supply and fixing in repair EVD evalution LAN protocol for Chiller Model KAS 070.14.
Supply and fixing in repair field card for Chiller Model KAS 070.14.
Supply and fixing in repair RS 485 Modbus board for Chiller Model KAS 070.14.
Supply and fixing in repair Electronic expansion valve, E6V for Chiller Model KAS 070.14.
Supply and fixing in repair cable for EXV 6M long, shielded (E2VCABS600) for Chiller Model KAS 070.14.
Supply and fixing in repair Voltage protection unit 415V for Chiller Model KAS 070.14.
Supply and fixing in repair winding protection unit 230V for Chiller Model KAS 070.14.
Supply and fixing in repair Solenoid Valve Kit CXH0 for Chiller Model KAS 070.14.
Supply and fixing in repair anabond paste for Chiller Model KAS 070.14.
Supply and fix in repair temperature sensor for chilled water/condenser/oil/discharge referigerant suitable for AC plant Make: DAIKIN, Model PFS11010DBRY
Supply and fix in repair pressure transducer for Evaporator/suction/discharge/condenser suitable for AC plant Make: DAIKIN, Model PFS11010DBRY
Supply and fix in repair oil heater suitable for AC plant Make: DAIKIN, Model PFS11010DBRY
Supply and fix in repair loader and unloader coil suitable for AC plant Make: DAIKIN, Model PFS1101D0BRY
Supply and fix in repair Solenoid coil for oil discharge line suitable for AC plant Make: DAIKIN, Model PFS1101D0BRY
Supply and fix in repair antifreezing switch suitable for AC plant Make: DAIKIN, Model PFS1101D0BRY
Supply and fix in repair electronic Timer CT-SDE suitable for AC plant Make: DAIKIN, Model PFS1101D0BRY
Supply and fix in repair Convertor AC to DC (220 to 24 DC) suitable for AC plant Make: DAIKIN, Model PFS1101D0BRY
Supply and fix in repair Thermal Relay CM-MSE suitable for AC plant Make: DAIKIN, Model PFS1101D0BRY
Supply and fix in repair fuse 32 A suitable for AC plant Make: DAIKIN, Model PFS1101D0BRY
Supply and fix in repair 3 pole power contactor rated current AC1 100A and AC3 85A with auxiliary contact block, 3 phase 415 volts, with coil voltage 220 volts suitable for 120 TR AC plant Make: DAIKIN, Model PFS1101D0BRY complete all as directed. Make : Siemens/L&T/Schenider/Havells/ABB/C&S
Supply and fix in repair 3 pole power contactor rated current AC1 80A and AC3 45A with auxiliary contact block, 3 phase 415 volts, with coil voltage 220 volts suitable for 120 TR AC plant Make: DAIKIN, Model PFS1101D0BRY complete all as directed. Make : Siemens/L&T/Schenider/Havells/ABB/C&S
Material and labour of repairing of ducting pipe insulation of pipe duct bore 100 mm complete all and specified as directed.
Material and labour of repairing of ducting square insulation of duct size 3ft x 3ft complete all as specified and directed.
Supply and fixing in repair 15 KW 20 HP 3 phase variable frequency drive complete all as specified and directed.
Supply and fixing in repair 3.7 KW 5 HP 3 phase variable frequency drive complete all as specified and directed.
M/S LAKSHMI COOLING CENTRE
M/S TRADE CENTRE
M/S L N ENTERPRISE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .