Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Accepted-Technical VILL GALYAN PO GHUMARWIN TEHSIL GHUMARWIN DISTT BILASPUR HP 174021 | BILASPUR | HIMACHAL PRADESH | 174021 | Accepted-Technical Accepted |
| 2 | Accepted-Technical HAMIRPUR ROAD NEAR BUS STAND UNA DISTT UNA HP | UNA | HIMACHAL PRADESH | 174301 | Accepted-Technical Accepted |
| 3 | Accepted-Technical | Accepted-Technical Accepted |
| 4 | Rejected-Technical | Rejected-Technical Rejected due to not fulfil the eligiblity. |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
22 Aug 2026, 5:00 pmClosed
Executive Engineer Jal Shakti Division Ghumarwin
Executive Engineer Jal Shakti Division Ghumarwin
Restoration of Rain Damages of LWSS Kot Dehra Hatwar in Tehsil Ghumarwin Distt Bilaspur HP SH Replacement Supply of mono submersible Pump and other electrical and mechanical accessories Under PDNA
2026_HPIPH_141164_1
GMR-BLP02-737(5820-60)Kotdehra
Open Tender
Civil Works
Item Rate
BHARARI
Please refer Tender documents.
6 documents required · 6 mandatory
₹350
₹5,000
2 Sept 2026
13 Aug 2026
24 Aug 2026
13 Aug 2026
22 Aug 2026
13 Aug 2026
13 Aug 2026 - 22 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply / fixing mono submersible pumping set of KSB/Crompton/ Amrut make comprising to latest relevant BIS Code. The pump should be fitted with bronze im peller of suitable alloys as per BIS 8034-1976 latest suitable for Clear cold water having greased packed bearings and shaft with wound stator on motor side and with soft protection sleeve on pump side ensuring better life for shaft coupled to a submersible squirrel cage electric induction motor (water proof type) suitable for operation on 430 volt three phase 50 CPS AC supply of required HP, RPM 2880 of KSB / Crompton/Amrut make conforming to BIS 9287-1979 latest with upto date amendments, totally dust and water proof for submersible duty isolated from the pump by intermediate casing with double mechanical seal in oil chamber and grease packed lubricated bearings and provided with stainless steel thrust bearing plate to with stand non vertical loads with minimum wear and tear. It should also be fitted with a device to take up expansion of water with the heating of motor. The pump set should include water level guards, erection clamps, cable clips and depth gauge etc. Total Head 29.74 mtrs Discharge 18.53 LPS | 12.5 | P/HP | - | - |
| 2 | LWSS KOT DEHRA HATWAR 1ST STAGE Supplying and fixing of MS fabricated control panel L&T make for submersible pump set of 25 HP complete with internal wiring and comprising of suitable volt mter, Amp mtr., Indicator, MCB switch gear, single phase preventer Star delta starter etc. a required complete in all respect i/c all lead and lift as per direction of Engineer in charge. | 1 | Each | - | - |
| 3 | Providing and fixing heavels standard / L&T make three pole 63 Amp switch disconnector HRC Fuse with base in SS encloser. | 1 | Each | - | - |
| 4 | Supplying of M/oil for various schemes under hatwar section | 15 | P/Ltrs | - | - |
| 5 | Providing and fixing complete set of Pin Rubber Bush 17 No complete in all respect. | 36 | Each | - | - |
| 6 | LWSS DIARA Providing and fixing LED street light of 50 watt having indivisual lences and IP66 protection of reputed make complete in all respect. | 1 | Each | - | - |
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.40 MB
Form6.pdf
Tender Documents • 0.32 MB
Form8.pdf
Tender Documents • 1.10 MB
Condition.pdf
Additional Documents • 0.34 MB
BOQ_209518.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .