Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.7 LAccepted-AOC GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | ₹35.7 L Quoted ₹36.0 L | L1 | Accepted-AOC AOC Accepted |
| 2 | L2₹37.5 L+₹1.5 L (4.14%)Rejected-AOC KRISHNA NAGAR BOOTY RANCHI 835217 | RANCHI | JHARKHAND | 835217 | ₹37.5 L+₹1.5 L (4.14%) | L2 | Rejected-AOC AOC not accepted |
| 3 | L3₹38.4 L+₹2.4 L (6.77%)Rejected-AOC SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | ₹38.4 L+₹2.4 L (6.77%) | L3 | Rejected-AOC AOC not accepted |
| 4 | L4₹38.6 L+₹2.7 L (7.37%)Rejected-AOC VIKASH NAGAR RAMGARH CANTT WARD NO 06 PO PS DISTT RAMGARH JHARKHAND PIN 829122 | RAMGARH | RAMGARH | JHARKHAND | 829122 | ₹38.6 L+₹2.7 L (7.37%) | L4 | Rejected-AOC AOC not accepted |
| 5 | L5₹38.8 L+₹2.8 L (7.87%)Rejected-AOC | ₹38.8 L+₹2.8 L (7.87%) | L5 | Rejected-AOC AOC not accepted |
Tender Value
₹34.5 L
EMD Value
₹69,900
Closing Date
29 Sept 2021, 6:00 pmClosed
GE RAMGARH CANTT
GE RAMGARH CANTT, JHARKHAND PIN 829122
Provn of Medical Gas pipe line sytem for HDU ICU and emergency at MH Provn of Lightning conductors at Museum P 131 Vivekananda Hall P459 PAO
2021_MES_471644_1
8300/3012/E8
Open Tender
Civil Works
Item Rate
120 days
GE RAMGARH
Class D a i b i
7 documents required · 7 mandatory
₹500
Yes
GE RAMGARH CANTT
₹69,900
Yes
1 Nov 2021
31 Aug 2021
1 Oct 2021
31 Aug 2021
29 Sept 2021
23 Sept 2021
Amount
Supply, installation, testing commissioning and maintenance of the following Medical Gas Pipe Line System conforming to the specification and relevant Indian Standards, the work not any civil and other electrical works the warranty period for the system will be 12 months for the date of handing over same. Note: (i) Demo for training to the medical staff for operating the system will be responsible by the contractor (ii) The comprehensive maintenance for a period of one year from the date of handing over to the user will he held responsible by the contractor and the complaint received the same shall be rectified within 24 hours without any reason (a) OXYGEN (i) control panel semi automatic alongwith Non-return valve, bar line pressure as per standard suitable for 4+4 Oxygen manifold system, complete all as specified and as directed. Make: Mediland Engineering/Life Care Device/Swastik/Hindustan.
(ii) 3 + 3 oxygen manifold Make: V-tech/PCL/Amico.
(iii) Surface S bracket assist valve oxygen gas outlet points. Make: Amiko/Varsha/Active
(iv) Oxygen flowmeter 0-15LPM with humidifier bottle. Make: GHL/Varsha/Active
(v) 1 + 1 size emergency supply system for oxygen with regulator (without cylinder) make: V - tech/Amiko/Varsha/Active.
(vi) Supplying, installation, testing and commissioning of Area alarm (3 gas), complete all as specified and as directed make: V-tech/Ingersoll/Ahuwalia.
(b) VACUUM (i) Vacuum System of the IR vacuum pump model 0.1 No with fly wheel, motor slide rails, V-Belts and Motor Pully complete with electricals No.cylinders, two piston displacement 58 CFM (approx) Base Frame with 5 HP motor, Vacuum receiver of 500 liters capacity filters Make:Indoair, Make: INGERSOLLRAND/Ahu Walia/Akash.
(ii) Surface S bracket SS valve vacuum/suction gas outlet points Make: Amiko/Varsha/Active.
(iii) Ward vaccum unit with regulator. Collection jar of 600 Ml with bracket. Make: Hariom/Mehta/Sharma.
(iv) Vacuum HP antistatic rubber tube.
(v) Vacuum probe
(vi) Low pressure rubber tube. Make: Hariom/Mehta/Sharma.
(c) Compressed Air: (i) Supplying, installation, testing and commissioning of oil free base mounted air compressor of capacity 58CFM, fully automatic mounted with 5HP motor including 500 Ltr Capacity of air receiver tank and electrical connections, complete all as specified. Make: INGERSOLLRANG/Ahuwalia/Anestiwata/INDO AIR.
(ii) Surface S bracket SS valve outlet points Make: Hariom/Mehta/Sharma.
(iii) Air Probe, Make: Prime Medical/SMC/Tridyent
(iv) Air Dryer, Make-Prime Medical/SMC/Tridyent.
Copper pipes: Supplying, installation, testing and commissioning of Medical gas pipe line of grade EW 53348 with imported fitting. Solid drawn, seamless di-oxide, non arsenical, half hard tempered and degressed, manufactured as per the BS 2871 Part I table - X of 1971 or similar ISI standard and chemical MEX flow, complete all as specified and as directed. (a) 15mm to 16 mm OD x 0.9 mm thick.
(b) 12mm OD x 0.9 mm thick.
OXYGEN ALARM AND VALVE SYSTEM: (i) Oxygen alarm with low pressure gauge, Make: Hariom/Mehta/Sharma.
(ii) Floor Isolation Valve 10mm to 12 mm, Make: Hariom/Mehta/Sharma.
(iii) Floor Isolation Valve 15mm to 16 mm, Make: Hariom/Mehta/Sharma.
M & L XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 Volts grade, cross-sectional area 10 Sq. mm 4, core, complete all as specified and as directed.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out in any type of soil, complete all as specified and as directed.
Excavation in post holes (or similar holes) each not exc. 0.50 cum in any type of soil getting out, and removing surplus soil to a distance not exc. 25 mtr and making good of surfaces all as directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of 0.50 mm thick pre-painted galvalume aluminum zinc coating GI based plain steel sheet of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
M & L for cement concrete type B2, 1:2:4 (using 40 mm graded aggregate) as in foundation filling and mass concrete etc., complete all as specified and directed.
Removing excavated materials n.exc 50 m and depositing, where directed at a level n.exc 1.5 m above the starting point, complete all as specified and as directed
M & L for roof trusses (framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections) including distance pieces, cleats main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates etc., conforming to Fe-410W (Gde E-250 quality A) complete all as specified and directed by Engr-in-Charge.
M & L painting on new steel surfaces of any description not otherwise described over 10cm width or girth applying two coat synthetic enamel paint over one coat of red oxide primer including preparation of surfaces complete all as specified and directed by Engr-In-Charge. (20+42)
Hardcore of broken bricks of gauge n exc 63mm, deposited, spread and levelled in layers not exc, 15cm thick, watered and rammed to a true surface, complete all as specified and as directed.
M & L for 100mm thick cement concrete type D-2, 1:4:8 (40mm graded aggregate) as in sub base for flooring for hard standing and paving complete all as specified and directed.
M & L 40 mm thick plain Cement concrete type B-0, 1:2:4, (using 12.5 mm graded stone aggregate) as in flooring, hardstanding finishing cement concrete surface even and smooth using extra cement in alternate panels of glass dividing strips, complete all as specified and directed. Note:- Glass dividing strips shall be measured and paid for separately.
S & F glass dividing strips 3mm thick, of width 38mm, complete all as specified and as directed.
Cutting out bricks, forming toothing for, and bonding new into old work in cement mortar including value of new materials value of new materials entering old walls and jointing and pointing (measured on vertical face in contact with old wall only).
M & L for RCC, type B2, 1:2:4 (using 20 mm graded aggregate) as in lintel, beams, bends etc., complete all as specified and directed.
M & L for brickwork with sub-class brick 'B', straight or curved on plan exc. 6m mean radius, builid in cement mortar (1:6), complete all as specified and as directed.
M & L for three coat of white wash on newly prepared surfaces on walls, etc., complete all as specified and as directed.
M & L for 75mm thick PCC (1:3:6) type C-2 using 20mm graded stone aggregate including finished surface even and fair without using extra cement as in plinth protection including necessary formwork of edge, all as specified and directed. Note: 10mm wide and 75mm deep joints shall be made at 3 mtr interval and at each corner and the same shall be filled with using bitumen 85/25 and sand in the ratio (1:3).
S & F Collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets, complete all as specified and as directed.
S & F steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded, complete all as specified and as directed.
S & F framed work such as grill grating etc wit end of bars shoudered and/or revated or forged into spikes framed guard bars barred iron doors and similar works conforming to Fe-410-0 or Fe 310-0 including all necessary welding complete all as specified and as directed by Engr-in-Charge.
S & F 3mm thick sheet glass ordinary quality and glazing with oil putty in squre n.ex 0.5 Sqm in each pane, complete all as specified and as directed.
S & F mild steel TMT bars 10mm dia and over, as in stirrups, cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.
S & F mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping, hooking ends and binding with mild steel wire (annealed) not less than 0.90 mm dia or securing with clips, complete all as specified and directed.
M & L for rendering 15mm thick in cement mortar (1:6) on fair faces of brickwork or concrete surfaces, finished even and smooth (without using extra or cement), complete all as specified and directed.
M & L for aluminium strip 25x3.15 mm with saddles, DNB insulator and fixing screws etc., for roof conductors and down condutors, complete all as directed. (2030+431.21)
M & L for Thermoplastic cable junction box IP-66 halogen free and weather proof with terminals suitable for 10 Sq mm dimension 167mm x 125mm x 82 mm (Cat part No. KF 5105 of Make Hensel), complete with all fixing accessories including testing all as specified and as directed. (62+15=77)
M&L ,for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to GI earth strip of size 25x4 mm (upto 7.5 metre in length from earth plate) by means of bolts, nuts check nuts & washers of galvanised iron or steel, protected by GI pipe 40 mm bore (light grade) and watering pipe 20 mm bore GI pipe (light grade) and PCC of chamber and coping shall in 1:3:6 type C-1 using 20 mm graded stone aggregate including excavation and earth work and removal of surplus soil and filling with black cotton soil upto ground level complete all as shown in electrical plate No 3 of SSR Pt-I, 2009 with CI cover 10mm thick of size 300x300mm with charcoal dust and common salt complete and earth lead connected to panel including testing complete all as specified and directed. Note : Earth test result should not less than one ohm. (62+15)
M & L for Air termination, single pointed aluminium rod 12mm dia and 300 mm long, with DNB insulators. complete all as specified and directed. (186 + 60=246)
Design, supply, installation, testing and commissioning of Hybrid Solar power plant 02 kWp, roof top including Solar Panel, Solar inverter, Module mounting structure complete and comprising of the following:- (a) Polycrystalline Solar Modules, MNRE approved- 02 KW, 250 Wp or above: Make Exide/WAREE/TATA. (b) Hybrid Solar PCU (MNRE Approved), 02 Kw/48V 1 phase- 01 Unit. Make: Statcon Energiaa/WAREE/TATA. (c) Solar Battery, Lead Acid Tubular 150 Ah/12V- 04 Units. Make: Exide/Luminious/WAREE. (d) MC 4 Connectors (DC cable Connection), IP 65, units as per requirement: Make Elmex/Sunclix. (e) DCDB, “DC Fuses+ DC SPD+ 1P65 Box as required”- 1 Unit: Make Fuse-Mersen or equivalent SPD-Phoenix. (f) ACDB, “AC MCB/MCCB+ AC SPD + IP65 Box- 1 Unit: Make: MCB-Schneider or Equivalent + SPD Pheonix. (g) DC Solar Cable (Input), 4 Sqmm DC cable Type-1, as required: Make: Polycab/Mescab/KEI. (h) AC Cable (Output), as per requirement: Make: Polycab/Mescab/KEI. (j) Nut bolts + Fasteners + Lugs & Thimbles +UV protected cable ties, “A Stainless steel nut bolts only): Make: Standard. (k) Bi Directional Meter, Unit- 1 No, 01 Phase net meter: Make: SECURE/INDOTECH/HBL. (k) Check Meter, Unit-1 No, 01 Phase Net Meter: Make: SECURE/INDOTECH/HBL.
M/S OMANIA ENTERPRISES
M/S ABHAY KUMAR AND BROTHERS
M/S ROHIT CONSTUCTION
m/s sheo kumar singh & sons
Vp sanjiv
Associated Engineers
BUILDCON ENTERPRISES
Kunwar Constructions Private Limited.
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .