Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹35.0 LAccepted-AOC 11 4 INDER BAWA MARG KISHAPUR RAJPUR ROAD RAJPUR DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹35.0 L | L1 | Accepted-AOC AOC accepted. |
| 2 | L2₹35.5 L+₹50,898 (1.46%)Rejected-AOC 137 3 STREET NO 4 RAJINDER NAGAR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | ₹35.5 L+₹50,898 (1.46%) | L2 | Rejected-AOC AOC rejected. |
| 3 | L3₹35.8 L+₹82,028.90 (2.35%)Rejected-AOC 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | ₹35.8 L+₹82,028.90 (2.35%) | L3 | Rejected-AOC AOC rejected. |
| 4 | L4₹37.5 L+₹2.5 L (7.28%)Rejected-AOC | ₹37.5 L+₹2.5 L (7.28%) | L4 | Rejected-AOC AOC rejected. |
| 5 | L5₹41.6 L+₹6.6 L (19.0%)Rejected-AOC 36A 60 CIVIL LINE TELIYAR GANJ ALLAHABAD UTTAR PRADESH 211004 | PRAYAGRAJ | UTTAR PRADESH | 211004 | ₹41.6 L+₹6.6 L (19.0%) | L5 | Rejected-AOC AOC rejected. |
Tender Value
₹47 L
EMD Value
₹94,000
Closing Date
4 Jul 2022, 6:00 pmClosed
GE Dehradun
GE (MES) Dehradun, Garhi Cantt, Mall Road, Tele - 01352750580
Repair/replacement of Sanitary/bath fittings, plumbing, flooring, plastering, joinery, false ceiling and wall paneling etc at 3 GARH RIF under AGE B/R-I of GE Dehradun.
2022_MES_530624_1
8477/A/E8
Open Tender
Civil Works
Item Rate
120 days
GE Dehradun
Class D Cat a (i)
8 documents required · 8 mandatory
₹500
GE Dehradun
₹94,000
Yes
10 Oct 2022
13 Jun 2022
6 Jul 2022
13 Jun 2022
4 Jul 2022
27 Jun 2022
Amount
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws and profile should match with galvalume sheet complete all as specified and as directed..
Dismantling of framed or unframed timber scantlings 40 sq. cm and over in section, in any position complete all as specified and directed
S&F Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors, post, pipes; fixed with angle cleats or other connecting plates Fe-290 (Gde E-165 complete all as specified and directed
Taking down and re-fixing the existing shutter in same opening after & including necessary easing/repair etc. exc. 1 Sqm but n. exc. 2 Sqm each complete.
Taking down and re-fixing the existing shutter in same opening after & including necessary easing/repair etc.of size n exc. 1 Sqm complete all as specified
Taking down shutter of any description, n. exc. 1 Sqm each and removing from site complete all as specified
All as per item No 8 here-in-above but exc. 1 Sqm but n. exc. 2 Sqm each and removing from site complete all as specified
Taking down chowkhats or frames with shutter n. exc 1.5 sqm each without taking off shutter from the frame complete all as specified.
All as per item No 10 here in above but exc. 1.5 Sqm and not exceeding 4 Sqm each complete all as specified.
S&F Pressed steel frames of size 105x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete all as specified (Note: framed filled with cement concrete1:3:6 type C0 12.5 mm stone aggregate to be included in the quoted rate).
S&F Pressed steel frames of size 125x60 mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete, as specified (Note: framed filled with cement concrete1:3:6 type C0 12.5 mm stone aggregate to be included in the quoted rate).
S & F 35mm thick second class hardwood (Golden Teak) glazed and Skelton factory made door shutters, open rebated and prepared to receive glass/gauze etc divided into squares with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plain, chamfered, fitting with cut and rebated beads for securing glass/ gauge complete all as specified in SSR Pt I-2009 section 8 clause 8.24 (a) and as directed.
S&F 30mm thick flush shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides including provision of suitable blocks for taking mortice locks, latches or other fittings complete all as specified Make :- Kitply/centuryply
S&F 30 mm thick moulded WPC factory made 100% solid door (conforming as per IS-4020) made from 100% lead free single extruded with 2, 4 or 6 raised panel design on the front side with 10 mm deep mould on single side with wood grain texture and back side palin with density not less than 600 Kg/cum. Manufactured by an ISO : 9001-2015 certified company. The door should be water proof, termite proof, fire etardant and having screw holding capacity complete all as specified. Make : ECHON/Sintex/Rajshree
S&F factory made 100 % solid wood plastic composite (WPC) door frame 75x50 mm made from wood plastic composite (single extruded process) material with density 780 Kg/Cum from ISO certified company door should be water proof, termite proof, fire retardant and having good screw holding capacity all as per specification and drawing as directed by Engineer-in-Charge Make : ECHON/Sintex/Rajshree
M&L mild steel framed work as in doors or gates of angle or other section with gusset plates, rails, braces, ball bearing and other similar works etc, complete, drilled for fixing of steel sheeting or other covering. Doors, etc to be prepared for hanging or sliding complete all as specified
S&F mild steel, plain, black sheet 0.80 mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitered angles, etc. as required complete all as specified
S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay,tower bolt etc. complete with glazing bars, dovetailed or welded complete all as specified
S&F factory made steel window with side hung shutters including box type hinges with steel handle, steel peg stay, tower bolt etc.complete without glazing bars, dovetailed or welded complete all as specified
S&F factory made steel ventilator with top hung shutters including hinges with steel handle, steel peg stay, tower bolt etc.complete all as specified
S&F in repair aluminum alloy powder coated door made out of hollow extruded aluminum section as mentioned below. Each door having 02 Nos Disc or D type handle, 02 Nos aluminum tower bolt 200 mm size, one brass mortice lock of six lever with key in duplicate regulated by double action hydraulic floor spring heavy duty (Make:- Sandhu/Ritz) shutter to be partly glaze with 5mm thick tined coloured glass in upper pannel and partly pannelled with 12mm thick both side laminated particle board in lower pannel fixed with glazing clip, rubber beading/gasket, anodised aluminum beading screw complete all as specified and directed at site. Chowkhat Frame:- 101.60x44.45x1.60mm Shutter verticle style :- 85x44.45x1.56mm shutter middle Rail :- 83.50x44.45x1.54mm Shutter Top Rail and bottom Rail :- 114.30x44.45x1.55mm Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F in repair powder coated Aluminium partition (Fixed) made out of aluminium powder coated section 83 x 44.45 x 2.00 mm including 5 mm thick glass/ACP Sheet complete with rubber packing/aluminum beading etc including dismantling of exixting structure complete all as specified and directed. Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F in repair aluminum alloy powder coated standard hollow section as mentioned below window frame (Bombay sliding) with two glazed shutter and one nos wire gauged shutter sliding type, with aluminum sections as per Series-A(15mm) 3 track of Jindal section numbers for sliding windows, and glazed with tinted glass coloured glass 4mm thick, fixed with glazing clips, rubber beading / gasket anodised beading, screw and lock type handle of size 75mm, 2 Nos aluminum tower bolt 150mm long etc complete all as specified and directed. Shutter Top & bottom size : 37.50x15x1.60mm Shutter inner lock size 37.50x15x1.60 mm Shutter side (Handle) size 37.50x15x1.36 mm Chowkhat bottom size : 50.30x26x1.20mm Chowkhat top & sides size: 50.30x26x1.00mm . Make: (i) Anodised aluminum section : Jindal / Hindalko / Indalco. (ii) Particle board: Navipan / Puratuff / Kitlam (iii) Glass: Saint gobain / Modi guard / Tata
S&F in repair Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and directed.
S&F in repair Aluminium (Die Cast body) Door closer hydraulically regulated designation No 1 universal type suitable for door shutters up to 1000mm in width and of weight between 61 to 80 kg and fixed complete all as specified & directed.
S&F in repair Brass Mortice lock, four levers vertical type, size 100 mm size complete all as specified.
S&F in repair of Aluminium body door cill at bottom part of door to stop entry of insect inside the room complete all as specified and as directed.
S&F 0.56 mm dia stainless steel wire cloth with average width of aperature 1.18 mm and fixed with tinned tacks or galvanised wire staples complete all as specified and directed.
Hacking out old broken glass (any thickness, size, quality or description) from wooden frames or stone, concrete or brick surrounds, glazed with putty or fixed with beads complete all as specified
S&F 4 mm thick sheet glass ordinary quality and glazing with oil putty or wooden beads in square area n. exc. 0.5 Sqm in each pane complete all as specified
S&F mild steel framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 including necessary welding, drilling hole complete.
S&F factory made 100 % solid wood plastic composite (WPC) flush type shutter of 18mm thickness one side laminate consisting of panel of PVC profile of 18mm (+ 0.7mm) thick of denisity 600 kg per cum manufactured by ISO-9000 certified company using for shutter cillicia ply 18mm thick and fixed with frame. The thickness of shutter is edges painted by matching colour of PVC lining of plain/prelim coloured PVC sheet using etc complete as per manufacture specification.Make : ECHON/Sintex/Rajshree
S&F magnetic catcher and striking plate including letting in and fixed complete all as specified.
S&F Continious (PIANO) hinges, mild steel, bright finish or electrogalvanised. 30 mm width of flaps (when open) complete all as specified as directed.
S&F stainless steel barrel tower bolts Gde-204 150 mm long one piece and fixed complete all as specified.
S&F stainless steel butt hinges, medium weight Gde-204 100 mm long one piece and fixed with screws/welded to frame ,complete all as specified.
S&F stainless steel handles Gde-204 150 mm long one piece and fixed with screws/welded to frame ,complete all as specified.
S&F Hasp and staple 75mm safety type, stainless steel Gde-204 with hinge pin including bolt to hinge plate and fixed with screws complete all as specified.
S&F 300 mm long stainless steel sliding door bolt (bolt not less than 12 mm dia) Gde-204 with hasp & staple and fixing clips of SS sheet, and SS fixing bolts and fixed complete all as specified.
S&F floor door stopper of aluminium alloy body and tongue, anodized with hard drawn steel spring, fixed to floor of size 140 mm complete all as specified.
S&F in repair stainless steel grade 204 drapery rod 20mm dia including decorative brackets, decorative finals at both ends complete all as specified.
Demolition of Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified.
M&L for 75mm thick PCC 1:3:6 type C-1 using 20 mm graded stone aggregate as in plinth protection or similar work/places, laid in alternate bays and filling the joints with & including bitumen and sand 1:3 by weight, surface finished even and fair without using extra cement complete all as specified
M&L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in flooring, laid in alternate bays, surface finished even and smooth with using extra cement complete all as specified
Supply only for Glass dividing strips 38mm wide, 3 mm thick, inserted in position, conform to design complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8 type D-2 using 40 mm graded stone agg as in sub base etc complete all as specified and as directed.
M&L factory made prepolished rubber moulded vibromatic Chequred cement concrete tiles 30cmx30cmx22-25mm thick, set jointed and pointed in neat cement slurry with grey cement and colour pigment to match over and including 15mm thick screed bedding layer in CM (1:6) and dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified.
M&L non skid / mat finish ceramic colour tiles of size 300 mm x 300 mm and 6- 7 mm thick, in floors etc, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 including dismantling of old tiles complete all as specified and directed.
M&L glazed ceramic colour tiles size 300 mm x 450 mm x 6-7 mm thick on vertical surfaces such as dado, skirting etc set and jointed in neat cement slurry and pointed in coloured cement to match over and including 10 mm thick rendering in cement mortar 1:4 and dismantling of existing wall tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified
M&L non-skid / mat finish designed coloured joint free ceramic tiles of size not less than 400 mm x 400 mm x6- 7 mm thick in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed in cement mortar 1:6 and dismantling of existing tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified.
All as per item No 52 here in above but as in skirting over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified.
M&L vitrified light shade ceramic coloured tiles 10 mm thick (square/rectangular) polished,area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified
All as per item No 54 here in above but as in skirting over and including 10 mm thick rendering in cement mortar 1:4, complete all as specified
M&L heavy duty endura ceramic coloured parking tiles 10 mm thick dark shade (square/rectangular) polished,area of each tiles not exceeding 0.36 sqm, in floor etc. Set and jointed in neat cement slurry and pointed in coloured cement to match over and including 15 mm thick screed bed in cement mortar 1:6 and dismantling of existing floor tiling including cement mortar bedding (but not backing) and rubbish off the premises complete all as specified.
Demolition of Stone slabs and tiles laid, bedded in any mortar of any description or thickness in floors, aprons etc complete all as specified and directed. .
M&L for granite stone 18 to 20mm thick glazed (table rubbed and polished) fixed as in staps, window cills, cooking plateform and the like set in cement mortar 1:4 and pointed with white cement (1:2) using marble dust with admixture of pigment to match and exposed edges rounded with and including screed bed or bedding layer of mortar 15 mm thick in cement mortar 1:4 for laying floor finishes complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 18-20mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 15 mm thick screed bed in cement mortar 1:6 complete all as specifeid
M&L for Machine cut kota stone as in skirting 15-18 thick laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing over and including 10 mm thick rendering in cement mortar 1:4 complete all as specifeid.
S&F in repairs PVC connection 15 mm dia 450 mm long with brass fly nut at both ends complete all as specified.
S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including cantilever brackets of suitable angle iron,CP brass waste coupling ,superior quality PVC waste pipe and connecting union to pipe overall size 915mm x 460mm bowl size 410mm x 330mm x 160mm complete all as specified.
S&F in repair sinks made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar to dwarf wall or including cantilever brackets of suitable angle iron,CP brass waste coupling ,superior quality PVC waste pipe and connecting union to pipe overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified.
S&F in repairs, vitreous china wash down water closet pedestal pattern white (excluding flushing cistern and flush pipe) with CI ‘P’ or ‘S’ trap including plastic white sheet cover, CP jet spray with 1.0 metre long PVC pipe, connecting to stack pipe and flushing pipe and complete including making good to floor complete all as specified.
S&F in repair vitreous china squatting pan “ORISSA PATERN” of size 580 mm x 440 mm, white, with integral foot rest (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, anti syphonage pipe etc and making good to floor complete all as specified.
S&F in repairs Plastic water closet seat, white, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device complete all as specified.
S&F in repair 10 litre capacity PVC low level flushing cistern ‘ white’ with inlet, float valve including brackets with 32 mm dia PVC pipe/bend 600 mm long complete all as specified.
S&F in repair vitreous china wash hand basin white, flat back of size 550mmx400mm fixed on and including cast iron cantilever bracket, 32mm dia brass waste coupling and 32 mm dia PVC waste pipe including fixing of waste fitting etc complete all as specified. Make : Jaquar cat part No (CNS-WHT-301) and equivalent in Hindware/ Parryware.
S&F in repair CP brass 3 in 1 hot & cold 15 mm dia wall mixer for mixing hot and cold water with telephonic shower with connecting legs &flanges complete all as specified and directed. Make : Jaquar Model No CON 281KN, HSH 1929 & OHS 1989/Marc ES547A & ES 531 (Telehone shower) ES 549 (shower) ES 536 (Shower) or equivalent in Hindware/ Parryware.
S&F in repair 15mm dia brass chromium plated centre hole wash basin/ sink mixer with accessories in wash basin for mixing hot and cold water, screwed down for 15 mm dia bore GI Pipe complete all as specified and directed. Make : Jaguar CAT Part No SOL-6001B/Hindware CAT Part No F450009/Parryware CAT Part No G0665A1
S&F in repair brass chromium plated ovehead shower with shower arm complete all as specified and directed. Make : - Parryware Cat Part No T9985A1(Shower) & T-9999A1(Arm)/Hindware Cat Part No F160054 (Shower) & F190016(Arm)/Jaquar Cat Part No OHS 1999 (Shower) & SHA479L300 (Arm).
S&F in repair 15 mm bore Angle cock/stop valves, cast copper alloy, fancy type chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions complete all as specified. Make : - JAGUAR Cat Part No FON-40053/Hindware Cat Part No F160017/Prayag Cat No 9410
S&F in repair 15mm bore Bib taps long body cast copper alloy fancy type chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. Make : - JAGUAR CAT Part No ALI-85037/Hindweare CAT Part No F-370004/Prayag CAT Part No S9906
S&F in repair CP Health Faucet with 1.20 mtr metalic expandable tube & hook complete all as specified. Make : Jaquar Cat No.ALE-ESS-585/Parryware Cat No. T9941A1 or equivalent in Hindware.
S&F in repair CP grating 100mm to 125 dia round fix on floor/ nahani trap with hole/without fixed with cement mortar, complete all as specified and directed.
S&F in repair looking mirror mounted on decorative type PVC frame of size 600 x 450 mm x 5 mm thick to wooden plug with CP brackets screw complete all as specified .
S&F in repair 20 mm dia brass chromium plated towel rack of 3 sets type 60cm long between flanges including pair of fixing brackets complete all as specified and directed. Make: Jaquar Cat Part No AKP-35781PS/CAN-1181FHS or equivalent in Hindware / Parryware.
S&F in repairs brass chromium plated towel ring complete all as specified. Make : Jaquar Cat No.AQN-7721 or equivalent in Hindware / Parryware..
S&F in repairs chromium plated Toilet paper holder complete all as specified. Make : Jaquar Cat No.ACN -1151N or equivalent in Parryware/ Hindware.
S&F in repair brass spindle for bib tap, pillar tap, stop cock,angle valve, wall mixture and basin mixture of any description etc, complete all as specified and directed.
S&F in repair 32 mm Waste fittings/coupling, brass, chromium plated for sinks, basins, etc. with long screwed shanks and fly-nuts complete all as specified
S&F in repair 32 mm dia PVC waste pipe for WHB and sink 90 cm long with union, complete all as specified and directed. equivalent).
Taking up or down steel tubing and connection incl removal from site of 15mm bore pipe complete all as specified
Taking up or down steel tubing and connection incl removal from site of 20mm bore pipe complete all as specified.
Supply, fixing, laying & testing 15 mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as flanges, unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors and testing complete all as specified and directed.
Supply, fixing, laying & testing 20mm dia (Nominal bore) galvanised iron water tubing 'medium grade' with and including all GI fittings such as unions, reducer sockets, socket reducing bends, elbows, tee, checknuts, caps, plugs etc. fixed complete to walls and ceilings or laid in floors complete all as specified and directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc.; and cutting chases for concealed water tubing or concealed conduit wiring, etc. and making good, cutting not exceeding 20cm girth complete all as specified.
S&F in repair 75 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall / laid in trenches complete all as specified
S&F in repair 110 mm bore UPVC (SWR) pipe pressure 4kgf/cm2 single socketed in any length with rubber ring, fixed on wall/ laid in trenches complete all as specified
S&F in repair 75 mm bore UPVC (SWR) bend with oval acess door ,'T'socket reducer etc complete
S&F in repair 110 mm bore UPVC (SWR) bend with oval acess door ,'T'socket reducer etc complete
S&F in repairs heavy duty thread type PVC water tank cover with fixing frame fixed on PVC tank with 4 Nos of screws for 500/1000 litres tank complete all as specified and directed by the Engr-in-Charge.
M&L cleaning of water storage tank capacity exceeding 250 litres but not exceeding 500 litres, mechanically using pressure pump with disinfectant chemical including cleaning & removing all scale & dirt etc from existing tanks, mouths of circulating pipes and outer surface of any description & washing down in the manner complete all as specified and directed.
M&L cleaning of water storage tank capacity exceeding 500 litres but not exceeding 1000 litres, mechanically using pressure pump with disinfectant chemical including cleaning & removing all scale & dirt etc from existing tanks, mouths of circulating pipes and outer surface of any description & washing down in the manner complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks Capacity of tank 500 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, complete all as specified and directed.
S&F rotational moulded polyethylene water storage tanks Capacity of tank 1000 litres tripple layer, white colour, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-2009 including dismantling of existing unserviceable tank and removing from site, complete all as specified and directed.
S&F ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe and fixed for 15 mm bore size (Minimum weight 142 gms), complete all as specified.
S&F in repair ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe for 15 mm bore size (Minimum weight 142 gms), complete all as specified.
Demolition of Brickwork or stone/bou-lder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles complete all as specified
M&L brick work with fly ash brick straight or curved on plan exc. 6 m mean radius built in cement mortar 1:6 including demolition of existing old brick work or stone masonary built in cement mortar including all quoins, arches, pillars etc complete all as specified
M&L brick work with fly ash brick straight or curved on plan to any radius built in cement mortar 1:4 as in half brick thick wall complete all as specified.
Taking down cement or cement lime plaster on walls any description including racking out joints hacking for key, scrubbing down with water etc. and removing rubbish complete all as specified and directed.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surface in cement mortar 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on other than fair faces in cement mortar 1:4 including finishing the surface even and smooth without using extra cement complete all as specified and directed.
M&L for rendering 10mm thick on ceiling in cement mortar 1:3 including finishing the surface even & smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coats of oil bound distemper over a coat of primer complete all as specified in SSR Part I and directed by Engr-in-Charge.
M&L for preparation of newly plastered surface of wall and applying two coat of cement base paint over a coat of primer complete all as specified
M&L for preparing of old plastered and unplastered surfaces of wall and applying one coat of cement based paint complete all as specified & directed by the Engr-in-Charge.
M&L for preparing of old plastered and unplastered surfaces of wall and applying one coat of distemper oil emulsion complete all as specified & directed by the Engr-in-Charge.
M&L for preparing of old plastered and unplastered surfaces of ceiling and applying one coat of distemper oil emulsion complete all as specified & directed by the Engr-in-Charge.
M&L for complete removal of existing treatment from plastered surfaces of walls using steel wire brushes and hand held electrical grinder complete all as specified.
M&L for preparing of old decorated surfaces and applying two coats of cement based paint on walls complete all as specified & directed by the Engr-in-Charge.
M&L for preparing of old plastered and unplastered surfaces of wall and applying two coats of distemper oil emulsion complete all as specified & directed by the Engr-in-Charge.
M&L for preparation of old decorated surfaces and applying one coat of weather proof paint any colour external finish on wall/chajja,roof facia (projected portion) complete all as directed by Engg-in-Charge.
M&L for preparation of old decorated surfaces and applying one coat of interior plastic emulsion paint on wall/ceiling complete all as directed by Engg-in-Charge.
M&L for complete removal of existing treatment from plastered surfaces of ceiling using steel wire brushes or hand held electrical grinder complete all as directed.
M&L for preparing of old plastered and unplastered surfaces of ceiling and applying two coat of distemper oil emulsion complete all as specified & directed by the Engr-in-Charge.
M&L for two coats of synthetic enamel paint on new or previously untreated steel surfaces of any description over 10 cm width or girth over a coat of red oxide primer including preparation of steel surfaces complete all as specified.
M&L for one coat of synthetic enamel paint on old steel surfaces of any description over 10 cm width or girth including preparation of steel surfaces complete all as specified.
M&L for two coats of Synthetic enamel paint on new wooden surfaces of any description over 10 cm width or girth over a coat of pink primer including preparation of surfaces complete all as specified
M&L preparation of old painted surfaces of wood & wood based material of any description over 10 cm width or girth and applying one coat of synthetic enamel Paint complete all as specified
Taking down carefully copper/Aluminum point wiring (light, fan socket and power) complete including switches, ceiling rose lamp holder and regulator etc and removing from site and making good disturbed surfaces of walls/floors etc complete all as specified and directed by Eng-in-charge.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in and including concealed PVC conduit medium duty 20 mm dia or higher and heavy grade conduit fittings and heavy duty accessories with suitable size of sunk type cast iron or pressed steel terminal box 1.6mm thick for mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed for following. Note: The wiring to be done as per IE rule and maintain colour code accordingly.
One light point point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
All as per item No 123 above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sq mm complete all as specified.
M&L for point wiring with 1.5 Sqmm. (nominal area) FRLS, single core PVC insulated 1100 Volts, grade multistranded copper conductor unsheathed in existing PVC / Steel, concealed and existing MS boxes, mounting of switches, sockets, fan regulator etc with 3 mm thick plastic laminated sheet as top cover, one green colour FRLS cable of same size as earth wire up to common earth and connected to earth dolly compete all as specified and directed by Eng.-in-charge of following. Note: The wiring to be done as per IE rule and maintain colour code accordingly
One light point point /bell buzzer point controlled by one-one way switch.
One ceiling fan/Exhaust fan point controlled by one-one way switch through Regulator.
One three pin 5 Amp socket on same board with other switches.
One three pin 5 Amp socket on independent board
One light point controlled by two No two way switch
All as per item No 125 here-in-above but one 3 pin socket outlet 15 Amp independent, with cable 2.5 Sq mm size, with earth continuity coductor of size 1.5 Sq mm complete all as specified.
S&F switch piano flush, button type 5 Amp SP 250 V AC complete all as specified & directed.
S&F switch piano flush button type 15 Amps SP 250 V AC complete all as specified & directed.
S&F socket outlet multipurpose 3 Pin 5 Amp and 2 Pin 5 Amps 250 V AC complete all as specified & directed.
S&F socket outlet two in one three pin 5 Amp and 15 Amp 2 module 120 W flush type complete all as specified.
S&F Bell switch paino flush button type 5 Amp complete all as specified.
S&F ding dong bell AC 230 V single pole complete all as specified and directed .
S&F switch paino flush button type 5 Amp SP 2 way 250 V AC complete all as specified and directed.
S&F step type regulator socket type double module 5 step for ceiling fan 1200/1400 mm size 230 volts 6 Amp 400 watts complete all as specified.
S&F ceiling rose, 3 terminal/PVC/polycarbonate, isolated body 250 V AC complete all as specified.
S&F lamp holder,pvc/polycarbonate type with back platesuitable for batten fittings including 9w LED bulb complete all as specified & directed.
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 10 Sq.mm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 10 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. (Note: Two run 10 Sqmm cable and one run 10 Sqmm cable and one run conduit shall be measured as one run)
M&L in replacement sub main wiring with 2 Single core PVC insulated unsheathed FRLS cable 1100 Volts grade heavy duty copper conductor multistranded of size 6 Sqmm. (nominal area) drawing in and including 20 mm. dia or higher PVC conduit medium duty concealed, conduit heavy duty accessories and fittings. Insulated unsheathed FRLS cable copper conductor multistranded of size 6 Sq. mm. as earth wire upto common earth and connected to earth dolly complete all as specified & directed. (Note: Two run 6 Sqmm cable and one run 6 Sqmm cable and one run conduit shall be measured as one run)
S&F in replacement sheet metal enclosures 240 volt with 200 Amp rated bus bar for double door 8 way DB,s IP-43 IK 09 metal door suitable for one MCB SPN as incoming and 06 MCB SP as out going complete all as specified and directed.
M&L for service cable 10 sqmm twin core weather proof aluminium conductor cable PVC sheathed PVC insulated round suspended with No. 8 SWG GI wire and reel insulators at distance of 0.1 mtr duly connected with earthing and clamp etc from pole to pole complete.
All as per Item No 140 but 6 sqmm x 2 core cable complete all as specified.
S&F in replacement sheet metal enclosures Triple pole and neutral double door 415 Volt 4 way DBs IP-43 IK- 09 Vertical type suitable for 200 Ams rated bus bar & one MCCB 100 Amp as incoming and 12 MCB SP as outgoing complete all as specified and directed.
S&F MCB double pole 240 Volt 10 KA 40 Amp 'B' series conforming to ISI marked complete all as specified & directed.
S&F MCB single pole and 240 volt 10 KA 5-32 Amp 'B' series conforming to ISI marked complete all as specified and directed.
S&F in replacement MCCB 415 Volt 16 KA 4 pole 63 Amp magnetic trip release & setting as incoming with fixing arrangement complete all as specified and directed.
S&F in replacement wall mounted LED tube light fitting 1x20/22 watts extruded aluminium polycarbonate covers PF 0.9 and above operating voltage 140V-270V colour temp 6500K & lumen input output 95 Lumen per watt and connected to ceiling rose with required length of two core flexible copper cable 23/0.0076 fixed on wall/roof complete all as specified and directed. Make: Philips cat part No TMC 501P1xT LED 22WP-3241(Tube Batten) and MAS LE$D 1200mm 18W-865-T-81 (Tube) / Wipro Cat part No WI0922208 (Tube Batten) LL13-181-65SE (Tube)/ Havells Cat Part No LUMILINEPLUSBS20WLED865SPCSS (Tube Batten) CRYSTAL1213T8DSTL20WLED865SGLASS(TUBE DOUBLE SIDE)
S&F in replacement mirror light decorative compact luminarious with decorative ends caps 9/10 Watt LED with all accessories and including connecting up with three core flexible copper conductor cable of suitable size . Make Havells Cat No Edgelite or equilent in Philips/Wipro./ Eveready/ crompton
S&F in replacement LED light fitting 1x10 w bulk head fitting complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size Make:WIPRO CAT PART NO-LW07-141-XXX-57XXor equivelent , HAVELLS/CROMPTON/ EVEREADY
S&F in replacement LED light fitting decorative wall mounting SS brush finish fixture with frosted glass suitable for upto 1x40 watt mini glass lamp with and including one no 12 watt LED lamp. complete with accessories and including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as specified.
S & F high efficiency LED bulbs 1 X 12 watt that can be used as a ready replacement for existing GLS ad CFL direct fit in holder complete all as specified and directed.
S&F in replacement air ventilation fan matalic body 300mm, 900 RPM, single phase, 230V AC including necessary, M&L for making hole fixing arrangement on wall with frame holdfastner, bolt, washer etc including connection with twisted white three core flexible copper multistranded conductor cabl from ceiling rose to connector all a directed by Engineer-in-charge. Make:- Havells cat part No. Ventil Air DXWHT, CG cat No. BRISKAIR or equivalent Orient.Note: old unserviveable fan shall be deposite in E/M yard.
M&L for making hole fixing arrangement on wall with frame holdfastner, bolt, washer etc (stone/brick wall cutting in circular shape, grouting or suitable bolts) suitable for 300 mm exhaust fan and making disturbed surface good plastering and distempering etc complete all as specified and directed.
Supply and Fixing Integral LED Bldg security Light Luminaire comprising of pressure die cast aluminum housing heat resistant toughened glass with frame IP-65 protection road way luminaries with high power LED 40/45 watt with efficiency 100 lumen/watt at system level, CCT>5700K, with average life class 50,000 burning hours, complete all as specified and directed. Make:- Crompton model No. LSTP-45-CDL/Havells model No. ENDURAPEARLNEOSL 40WLED757PASYTOPC /Philips Cat Part No BRP409LED CW036MRFGIPSUGRand syska SSK-ST-40W including taking out old unserviceable street light.
Supply and fixing of LED tube rod 18/20 Watts single or double sided connections polycarbonate complete incl making connection alteration in existing tube light fitting complete all as specified.
S&F in replacement of U/S Tamper Proof electronic single phase whole current energy meter (LCD Display) 10 Amp to 60 Amp, 240 volt class 1.03 and class 2.05 AC supply including cable connection, proper sealing with lead. The meter shall comply with the latest version of IS-13779 with atleast 2 anti tamper LED indication of line load reversal and earth loading indication including electrical connection with existing system and sealing properly including push fit type pvc box complete. The meter shall work satisfactory with guarantee accuracy as per limit of IS-13779. The meter shall be fixed on existing steel boxes on wall complete all as specified and directed. (Note: Old U/S Meter shall be deposited to E/M store yard). Make:- L&T/ Legrand/Secure/BHEL.
S&F in replacement of ceiling fan 1200 mm sweep single phase 230 volts double ball bearing with down rod , canopy, blades etc BEE 5 star rated including connecting with twisted three cord flaxible copper conductor cable (23/.0076 ) from ceiling rose to connector of fan comlete all as specified and directed.( Note: Old unserviceable ceiling fan will be deposited in E/M store yard. )
S&F in replacement of 3 core PVC insulated copper cable of size 40/0.0076 multi standard in repairs complete all as specified and directed by Engineer-in-Charge. Make Plaza, National, Shalimar.
S&F copper flexible wire hoisted twin cord 23/0076 for connection of ceiling fan etc.complete all as specified.
Supply only fan capacitor 2.5/3.15 mfd make universal / Asian/Epcos .complete all as specified and directed.
Supply only fan capacitor 4 mfd complete all as specified and directed make universal / Asian/Epcos
Supply only heating element any type/size as per site requirement of capacity 2 KW ISI Marked. Make:-Theta/Newton/Dasmesh/Bajaj
Supply only thermostat for geyser long type 11" in length as per site requirement temp setting on 60 degree centigrade ISI Marked, long type complete all as specified and directed. Make: Dashmesh/Indofors/Donfoss/Bajaj
S&F in replacement of water supply PVC flexible connection Nylon braided with suitable threaded check nut with washer complete suitable for hot/ cold water 15mm dia alongwith threaded Brass nuts and washers 45 cm long complete all as specified and directed. Make:- POLO/Havells/Prayag
Supply only syphon assembly for geyser any type of hole (6/7/9) all complete as per existing make & size as per site requirement all complete all as directed by Engr-in-Charge. Make:- Dashmesh/Theta/Newton/Bajaj.
Supply only pressure release valve as per existing make and size geyser spring loaded 15 mm dia complete all as specified and directed.
Supply only rubber Gasket as per existing make/size site requirement suitable for 25/50 Ltr capacity geyser complete all as specified and directed.
S&F in replacement of Geyser vertical mount type 25 Ltrs capacity five star rated , shockproof and rust proof metal body compact size including two nos PVC connection heavy duty and connecting with all fixing arrangement of nuts & bolts and fixing on wall complete all as specified & directed . ( Note: old unserviceable Geyser will be deposited in E/ M store yard )
S&F in replacement Sheet metal enclosure with socket plug and MCB single pole and neutral enclosure with two pine and earth plug and socket complete with one single pole MCB 240 volts 20 Amp all as specified and directed by Engineer-in-Charge.
S&F plug top 3 pin 15 Amp in repair. ISI marked complete all as specified. Make Anchor/ Cona/ Plaza
Materials and Labour for earthing complete with galvanized steel earth plate electrode 600 mm x 600 mm x 6.0 mm thick buried directly in ground end vertically to a depth not less than 2.25 meter deep below ground level with top edge of the earth plate at a depth not less than 1.5 M below normal ground level connected to galvanized steel earth wire 4 mm dia by means of bolts, nuts check nuts and washers of galvanized steel and connected to main switch board or main control board as directed and including provision of concrete pit in PCC (1:3:6) type C1, pre-cast RCC (1:2:4) type B1, cover slab 54 cm x 54 cm x 5 cm reinforced with 8 mm dia. TMT bars @ 150 mm c/c both ways, and with one handle for lifting made out of 10 mm dia MS round bar, provision of funnel, wire mesh, 20 mm bore galvanized steel tubing (Medium grade) for watering, charcoal or coke and salt in alternate layers, 15 mm bore galvanized steel tubing (light grade) for protection of earth lead connection, including necessary excavation and earth work in any type of soil and necessary testing complete all as shown on electrical plate No 3 of SSR Part –I (2009) and as directed.
Supply, laying, jointing and testing in replacement underground XLPE insulated, armouredheavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 25 Sqmm 4 Core laid in trenches/ducts/along poles/through pipe under road etc with new aluminium lugs of cable size all as specified and directed.
All as per Item No 171 here-in-above but 16 Sq mm x 4 core complete all as specified.
M&L for excavation in trenches n. exc. 1.5 mtr wide and n. exc. 1.5 mtr in depth for laying of underground cable, foundation of pole and getting out in any type of soil complete all as specified and directed.
M&L for returning, filling in excavated soil in trenches including spreading, levelling, watering and well ramming in layers n. exc. 25 cm thick complete all as specified and directed.
M&L for Removing of excavated soil to a distance n. exc. 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed.
M&L for laying local dry clean sand filling for cushioning in trenches around under ground cable complete all as specified and directed.
M&L for laying well burnt brick, old size in trenches, as protection of under ground cable complete all as specified and directed.
Supply and lay in replacement in trenches fixed to poles, wall, laid in floor GI steel tubing medium grade 50 mm bore with fitting GI clamps made out of 50 x6mm flat iron 02 Nos, bolt, nut & washers etc or wooden rubber bushing at the ends of complete all as specified and directed.
M/s Anil Kumar
Saurav Enterprises
M/S C S AITHANI
PRAGATI ENTERPRISES
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .