Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.9 LAccepted-AOC | ₹5.9 L | L1 | Accepted-AOC L1 bidder |
| 2 | L2₹6.5 L+₹65,448 (11.2%)Rejected-Finance | ₹6.5 L+₹65,448 (11.2%) | L2 | Rejected-Finance L2 Bidder |
Tender Value
Refer Docs
EMD Value
₹9,400
Closing Date
16 Feb 2022, 3:00 pmClosed
The Chief Engineer, Sports Kerala Foundation
Jimmy George Indoor Stadium, Vellayambalam, Thiruvananthapuram
Supply and installation of 50 HP Monoblock Pump set and 15 HP Submersible Pump and Allied Electrical works.
2022_SKF_471382_1
08/SKF/CE/2021-22
Open Tender
Electrical Works
Item Rate
60 days
Thiruvananthapuram
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,300
Yes
₹9,400
Yes
5 May 2022
31 Jan 2022
19 Feb 2022
31 Jan 2022
16 Feb 2022
31 Jan 2022
Amount
Electrical Works
90.12.1.27 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3.5 core 25 sqmm
90.12.1.30 : Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)..3.5 core 70 sqmm
90.12.7.27 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required..3.5 core 25 sqmm with factory made clamp
90.12.7.30 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required..3.5 core 70 sqmm
90.12.41.8 : Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured copper power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3. core 16 sqmm with factory made clamp
90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required. 3.15 mm Copper Conductor (10 SWG)
90.16.1.6 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required 6 mm Copper Conductor (4 SWG)
9.1.20 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X25 sq.mm (28mm)
9.1.23 : Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
od51246/2021_2022 : Supply and installation of 125A, 4 pole On-Load Change Over Switches In SS Enclosure with all accessories complete as required
od51369/2021_2022 : Supply and installation of 100A, 4 pole On-Load Change Over Switches In SS Enclosure with all accessories complete as required
Supply and Installation of Motor,Pump with Starter
od51367/2021_2022 : Supplying, Installation, testing and commissioning of 50HP Three Phase Squirrel Cage Foot Mounted Induction Motor with starter panel with copper winding,Body Material/ Housing/ Casing<br>Cast Iron, electronic controller etc or equivalent, Control panel suitable for pump set having panel box made of CRCA sheet of 2mm thickness and fixed along with start/ stop push buttons, Ammeter, Single phase preventor, Voltmeter, Indicating lamps, MCB, Dry level guard sensor with control cable,etc. making connection suitable for existing lines with accessories as specified by Engineer in charge. The job includes connecting necessary guage PVC/HDPE pipe,installation of complete fittings and accessories with riser.Rate inclusive of all materials,fittings,labour,transportation complete. [KSP/Kirlosker, Texmo, CRI or approved equivalent make) with panel
od51368/2021_2022 : Supply,conveyance,erection, testing and commissioning of 3 phase 12 KW /15 HP Open well Motor Pump set working at 50 Hz 415 v AC Supply having Head Range (meters) : 51-78 MtrsSuction X Delivery (mm) : 80 mm X80mmPhase : Three Phase Type of Product : open well conforming to IS capable standard accessories ,Starter fixed along with start/ stop push buttons, Ammeter, Single phase preventor, Voltmeter, Ind ,etc. Work has to be executed as per the approved drawings and as per the direction of Engineer in charge.Rate inclusive of all materials,fittings,labour,transportation complete. [KSP/Kirlosker, Texmo, CRI or approved equivalent make) with starter
S.UnnikrishnanNair
Bidder Name
S.UnnikrishnanNair
SREEJITH S G
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_675865.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .