Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹7.8 L+₹100 (0.01%)Rejected-Finance | L2 | Rejected-Finance Higher Bid | |
| 3 | L3₹7.8 L+₹140 (0.02%)Rejected-Finance | L3 | Rejected-Finance Higher Bid |
Tender Value
Refer Docs
EMD Value
₹15,623
Closing Date
25 Sept 2024, 4:00 pmClosed
EE, South 24 Pgs. Elect. Divn.
57/2 Diamond Harbour RoadKolkata- 700 023
Urgent Electrical Installation work for Implementation of RATTIRER SATHI at Nurses Rest Room, Doctors Rest Room with adjust Toilet area of Main Hospital Building under Kakdwip S.D. Hospital, kakdwip under Kakdwip Electrical Sub Division, PWD
2024_WBPWD_755557_1
WBPWD/EE/S24PED/eNIT72/2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
7 days
Kakdwip
Please refer Tender documents.
4 documents required · 4 mandatory
₹15,623
30 May 2025
21 Sept 2024
27 Sept 2024
21 Sept 2024
25 Sept 2024
21 Sept 2024
Amount
Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish as per direction of EIC .(Avg. run 8 mtr.)
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire -- Do--Do---- On Board
S&F 415 V, Horizontal type, TPN MCB DB (6-way) with SS enclosure double-door with IP-42/43 protection, with cable-end box at both ends & Four Pole Isolators as incomer and SPMCBs ('C' Curve, 10 KA) as outgoing, concealed in wall after cutting the wall & mending good the damages to original finish incl. Interconnection with suitable size of copper wire and neutral link & provision for earthing attachment as per GS. Incoming 63 A FP Isolator -1 No, Outgoing 6-32A SPMCB-12 no. (Make:Legrand/ L&T/ABB/ Simens) .
Supply & Fixing 240 V, 6A, plug socket with separate 6 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required as per direction of EIC.
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & nsheathed copper wire (Brand approved by EIC) in 20 mm size PVC rigid conduit 'FR' (Precision make) incl. necy. fittings as required. a) 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC ( For Separate Board)
2x356/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm)
Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. [PWD/GS Page: F-5 Item: 9]
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) ECC
2x356/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm)
Supply and delivery of 1.1 kv grade 4 core 35 sq mm XLPE/PVC Ar Al cable, as per direction of EIC. [Make - Polycab/Havells/RR Kabel/Gloster]
Laying of above cable on wall/surface incl. S & F MS saddles with earthing attachment in 2x10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting, as per GS.
S&F compression type gland complete with brass gland, brass ring & rubber ring for dust & and moisture-proof entry of 4Cx35sqmm XLPE/PVC armoured cable, as per GS.
S/F Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket for 4 core 35sqmm XLPE-armoured AL. cable(Dowels make), tapes, anticorrosive paste & jointing materials :as per GS.
Supply and delivery of Twin LED Fitting (20Watt, 230VAC, 50hZ, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 2 nos LED Tube, as directed by EIC. [Make: Philips TMC 501 P 2xT-LED, Havells, Bajaj, CG, or as per EIC]
Supply and delivery of Single LED Fitting (18Watt, 230VAC, 50hZ, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 1 nos LED Tube, as directed by EIC. [Make: Philips Havells, Bajaj, CG, Wipro or as per EIC] (Luminous efficiency > 105 & <120 Lumen/watt. The LED Luminaries & accessories shall have BEE certification)
Fixing only above single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length, as per GS.
Supply & delivery of 1400 mm sweep 230 volt AC Ceiling fan incl. Blades, canopy etc. With 18" down rod(14SWG), Fork(10SWG), Heavy type insulator, 3/8th inch bolt with nut, heavy type split pin etc., as directed by EIC [Make-Orient - / Crompton/Usha]
Supply & fixing two pieces type fabricated beam to beam clamp (approx. length 2mtr.) made with 50X6mm MS strip suitable for fixing of special type of Fan Clamp and also tube light fitting to maintain uniform spacing, including S&F 4nos. Nut-bolts for fixing of clamp on Iron 'I' -section. as per direction of EIC
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire as per direction of EIC.
Supply and delivery of 230V 230mm (9") Exhaust fan with all necessary accessories, as directed by EIC. [Make: EPC Heavy Duty, Usha, CG, Bajaj or equiv Make]
Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: a) 23cm (9")
Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) a) 23cm (9")
S & Fixing 3-blades, 450mm full metal AC wall bracket fan (Orient: Tornado Wall -II - Gun Metal / Crompton / EPC) on wall by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) on 150mmX300mm best quality vernished wood or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length as per direction of EIC.
Supply & Delivery of High-wall Split-type Air-Conditioner having following specification: Cooling Capacity - 6.6 kW (Minimum) Minimum ISEER - 3.8, BEE level - 3-Star(min)[1st July22 to 31st December 2024] IS Compliance - IS-1391(Part-I & Part-II) with all amendment Refrigerant - R410A/R32 Compressor - Rotary/Scroll Evaporator & Condenser Coil - Copper Operating outdoor temperature - 50ºC and above Power supply -230V, 50Hz (±tolerance asper applicable standard), as directed by EIC. The scope of work is also includes supply of following (i) Necessary refrigeration copper line with nitrile rubber insulation and wrapping tape - 3 mtr (ii) Necessary 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster) - 3mtr and suitable plug top(Anchor/North West/Legrand/Havells) [Make: General/Mitsubishi Electric/Zamil/Daikin]
Installation, Testing & Commissioning of Indoor & Outdoor unit of above Hi wall split AC machine after making hole in wall etc. as per direction of EIC including Supply of required Refrigerant, S&F of necessary fixing arrangement for indoor and 40 x 40 x 5 mm MS angle iron frame for outdoor unit (or arrangement recomended by Manufacturer), duly painted, laying and making connection of refrigeration pipe, power cable, drain pipe etc. as per direction of the EIC.
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. (i) Supply & Fixing of extra refrigerant pipe (as requisite dia) with nitrile rubber insulation and wrapping tape [each mtr Refrigerent pipe will include cost of 1 metre liquid pipe line and 1 mtr gas pipe line of required dia and other accesories as required].
S&F of additional following items for length exceeding 3 mtr for complete installation and commissioning of aboove AC machines. i) 2.5 sqmm, 3/4 core copper cable (FRLS type - make : Finolex/RR Kable/Polycab/Havells/Gloster)
Supply & laying Soft Drawn PVC Drain Pipe 19mm dia with proper supports & brackets as per direction EIC. (Make: Suprime/Oriplast)
Hiring charges for scaffolding arrangement including dismantling at the end of work and carriage, for LC installation, per storey of building per vertical run
S&F of 250V double door Timer DB [equivalent of 2+8 way SPNDB] with sheet steel enclosure, pnosphitised powder coated neutral bar, DIN rail with IP-43 potection comprising with 1 no. 25A DPMCB ('C' curve 10KA), 2 no. 16A SPMCB ('C' curve 10KA), 1no. Programmable time switch-24 hrs with minimum switching of 15 minutes and 1 no. 18A/25A 2-Pole power contractor with inner-outer plate & internal wiring by suitable size of cu. wire incl. 1 no. Auto-Manual bypass toggle switch and provision for earthing attachment, incl. LED indication light for running condition with mechanical locking arrangement, as directed by EIC. [Make-ABB/L&T/Crabtree]
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of commissioning. 2) Total is rounded off to the nearest rupees.
M/S PRITAM ELECTRICALS AND ELECTRONICS (BID ID -5627611)
JANA ELECTRICALS (BID ID -5627557)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .