Loading…
Loading…
Tender Value
₹6.4 L
EMD Value
₹12,800
Closing Date
12 Mar 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
SRDEEGTVC
12 conditions · 1 needing a document upload
For electrical works, the contractor should have a valid electrical contractor license from the concerned statutory authority of any state of India. The electrical license should be in the name of the firm's or in the name of any authorized person of the tenderers firm. It must be ensured that the validity of electrical license should be valid during the entire contract period duly renewing at appropriate time for extending validity. If the tenderer hired the electrical license, authorization of the same should be submitted. 2) In case of other than Company/ Proprietary firm, Annexure - V(A) shall also be submitted by each member of a Partnership Firm/ Joint Venture (JV) / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. as the case may be. Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self-attested /digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
13 conditions · 1 needing a document upload
All the tenderers/Contractors have to deposit full earnest money and tender document cost as stipulated for the tender, through online modes as permitted in IREPS application through multiple banks net banking, debit and credit cards . All documents related to Partnership deed/Joint venture/ Consortium/ MOU, duly signed by the notary public, should be uploaded failing which offer will be summarily rejected.
I/We also hereby agree to abide by the Indian Railways Standard General Conditions Of Contract, with all correction slips up-to- date and to carry out the work according to the Special Conditions of Contract and Specifications of materials and works as laid down by Railway in the annexed Special Conditions of contract , General Instructions and conditions , explanatory notes of schedule of work and Annexures.
I/We hereby Confirm that the rates, rebates and/or other financial terms, if any, quoted by us in the relevant fields of the Financial Bid page will only be the ruling terms for deciding the inter-se ranking, and any such condition having financial repercussions, if quoted by us anywhere else including attached documents shall not be considered for deciding inter-se ranking
However, Railways shall have the right to incorporate any such condition quoted by us, in the contract, at their discretion, if contract is placed on us.
Manual submission of EMD and cost of tender form cannot be entertained/Considered and hence no need of uploading the scanned copy of financial instruments
Whether GST registration available or not?
The contractor has to submit the EPF Code as per the EPFO Act and also has to submit a statement in this regard before signing the contract agreement.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
The bidder has to fill in his quoted rate against each item in the Bid rate / Unit rate column. The bidding rate is Rs./ unit, the bidder has to quote his rate for the individual item only
Subsequent to the enforcement of GST Act, the modifications to Para-(a),clause 6, part I of Indian Railways Standard General condition of contract, July 2014 vide Railway Board letter No: 2017/CE/CT/4/GST(a) of 23/6/2017 is as detailed below: Clause No.6 - Care in submission of Tenders: (a)(i) Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer. (ii) Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017 (CGST)/ Integrated Goods and Services Tax Act, 2017 (IGST)/Union Territory Goods and Services Tax Act, 2017 (UTGST)/respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt & as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. iii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to Railway immediately after the award of contract, without which no payment shall be release to the contractor. The contractor shall be responsible for deposition of applicable to the concerned authority. iv) In case the successful tenderer not able to be registered under CGST/IGST/UTGST/SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority. The contractor is liable to pay the taxes as stipulated in the GST Act and Rules and also should furnish the details of GST to deduct from the contractor's bill.
Provision of FOB at Kayamkulam Rly station under ABSS - Electrical arrangement
V-EGSU-OT-06-2025-2026
V-EGSU-OT-06-2025-2026
Open
Works - General
180 Days
Thiruvananthapuram, Kerala
₹0
₹12,800
12 Mar 2026
19 Feb 2026
26 Feb 2026
49 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 6,39,335 | ||
| — | 110.00 | — | — | ||
| Transportation & Clamping of LTUG cable 4 core x 70 sq.mm along PF shelter/FOB/Cable tray etc complete with 25 x 3 mm GI fixing hardware including termination on looping boxes/Kiyosk/ switch room. (Cable will be supplied free, departmentally at TVC and transportation will be provided by railway. Loaidng and un-loading operation has to be arranged by contractor) | — | — | — | 9,020 | |
| — | 180.00 | — | — | ||
| Supply & laying of HDPE pipe of 75 mm dia, pressure rating up to 4 PN (Material grade PE 63) conforming to IS 4984 /1995 in the excavated cable trench /Existing trench/duct and threading of LTUG cable and termination at either ends with suitable size heat shrinkable sleeve (Cable will be supplied free, departmentally at TVC and transportation will be provided by railway. Loading and un-loading operation has to be arranged by contractor). | — | — | — | 66,240 | |
| — | 15.00 | — | — | ||
| Supply & Threading of LTUG cable of 4 core x 35 sq.mm through HDPE Pipe 50 mm dia pressure rating up to 4 PN (Material grade PE 63) as per IS 4984/1995,and laying the same in the excavated cable trench/existing trench. The cable should be with heat resisting insulation suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005. Acceptable make of cables: KEI, V-Guard, POLYCAB, AVO CAB, FINOLEX, HAVELS, RR KABEL, TORRENT, KEC(RPG), CCI, APAR. Termination of cable shall be done with suitable size heat shrinkable sleeve | — | — | — | 7,125 | |
| — | 30.00 | — | — | ||
| Supply of LTUG cable of 4 core x 35 sq.mm & clamping along building wall/PF shelter/FOB etc complete with suitable fixing hardware and termination in a standard manner as required at site. The cable should be with heat resisting insulation suitable for rated voltage at 1100 volts grade and conforming to IS: 7098 Part-1 1988 with amendment number 1 and 2 and 3 Reaffirmed 2005. Acceptable make of cables: KEI, V-Guard, POLYCAB, AVO CAB,FINOLEX, HAVELS, RR CABLES, TORRENT, KEC(RPG), CCI Termination of cable shall be done with suitable size heat shrinkable sleeve | — | — | — | 11,580 | |
| — | 6.00 | — | — | ||
| Supply And fixing of cable gland suitable for LTUG cable 4 core x 70 sq.mm and termination using aluminium socket duly crimped with suitable size heat shrinkable sleeve. | — | — | — | 2,022 | |
| — | 4.00 | — | — | ||
| Supply And fixing of cable gland suitable for LTUG cable 4 core x 35 Sq.mm and termination using aluminium socket duly crimped with suitable size heat shrinkable sleeve. | — | — | — | 1,220 | |
| — | 1.00 | — | — | ||
| Supply and fixing and commissioning of IS/IEC certified 1 No. 125 A 25 KA 4P MCCB in existing supply bunk | — | — | — | 14,744 | |
| — | 61.00 | — | — | ||
| Excavation of cable trench 0.3 m wide x 1.0 m deep (preferably) in ordinary soil, back filling of the excavated cable trench (After laying of cables) , ramming & consolidation properly | — | — | — | 28,914 | |
| — | 0.50 | — | — | ||
| Excavation of cable trench 0.3 m wide x 0.1 m deep (up to the depth of tarr/concrete) in tarred/concreted surface back filling of the excavated cable trench After laying of cables), ramming & consolidation properly. | — | — | — | 978.5 | |
| — | 0.50 | — | — | ||
| Concreting the top portion of the cable trench excavated in tarred/concreted surface to a depth of 10.0 cm, using 1:2:4 mix with M sand | — | — | — | 4,396.5 | |
| — | 45.00 | — | — | ||
| Fabrication painting (one coat of red oxide and two coat of black enamel), supply and fixing of 400mm width cable tray made out of 40x40x6mm L angle on both sides and 2Nos.of 25x6mm flat at an interval of 400-600mm with proper fixing arrangements at wall /PF shelter etc. as per site condition | — | — | — | 1,03,500 | |
| — | 60.00 | — | — | ||
| Supply & fixing of 16 SWG GI hot dip perforated cable tray of size width 150 mm& height 50 mm with suitable fixing arrangements in the FOB /PF shelter. | — | — | — | 35,520 | |
| — | 3.00 | — | — | ||
| Manufacture, supply and fixing of looping box of approximate size of 600X450X300 mm fabricated using 14 SWG CRCA sheet powder coated with hinged cover and locking arrangements and fitted with(1) 1 No. 100 A MCCB 25 KA (2) 4 Nos 40 x 6 mm copper bus bar of approximate length 250 mm each having opening at bottom for 2 Nos. of cable glands suitable for 4 core 70 sqmm XLPE cable | — | — | — | 66,699 | |
| — | 30.00 | — | — | ||
| Supply & drawing of PVC insulated FRLS copper cable of 10.0sq.mm four runs & 10 sq mm one run as earth wire conforming to IS 694, through PVC conduit mentioned including termination in a standard manner as required at site (termination box to Lift & Esc control DB) | — | — | — | 15,480 | |
| — | 30.00 | — | — | ||
| Supply & fixing/concealing of ivory colour ISI marked PVC pipe 32 mm dia x 2/2.5 mm thick conforming to IS 9537 (PART-3), in a open manner complete with bend, Ts, etc with fixing hardware (Clamping to be done at a spacing not more than 75 cm on the building wall/roof) | — | — | — | 4,680 | |
| — | 6.00 | — | — | ||
| Supply, erection testing and commissioning of MCB Distribution Board, 12 way IP-43 protected, CRCA sheet enclosure powder coated with suitable internal wiring to incorporate the following accessories (1) One No. 63 A 4P MCB (2) One No. 63 A 4P RCCB 100 mA (3) One No 25 A DP MCB (4) One No. 25 A 30 mA RCCB in a concealed/open manner as required at site ( for Lifts & Escalator) | — | — | — | 93,474 | |
| — | 450.00 | — | — | ||
| Supply and Wiring to fan & light points by using 3 runs of 1.5 Sq.mm copper cable ( in RGB color code , 3 runs of 1.5 sq.mm cable will count as 1 meter length) through existing PVC pipe in standard manner.(PF/FOB shelter wiring) | — | — | — | 38,250 | |
| — | 225.00 | — | — | ||
| Supply &fixing/concealing of ivory colour ISI marked PVC pipe 19/20mm dia x 1.4 mm thick conforming to IS 9537 (PART-3), in a open manner complete with bend, Ts, etc with fixing hardware (Clamping to be done at a spacing not more than 75 cm on building wall where ever applicable) | — | — | — | 16,425 | |
| — | 2.00 | — | — | ||
| Supply and fixing of polycarbonate box similar to Hensal model No.Mi 0600/0601 in the PF shelter for cable termination with 25x3mm , (approximate length 200mm) copper bus bar-4 Nos, SP MCB 2-4 A rating -10Nos.with all internal wirings complete by using 2.5sqmm copper wire | — | — | — | 49,000 | |
| — | 25.00 | — | — | ||
| Fabrication, supply and fixing of 16 SWG MS painted sheet steel box of size 150 x 100 x 53 mm with 3.0 mm thick phynolic laminated sheet top and fitted with 1 No. ceiling rose, 1 No. 5 A flush type fuse unit completely pre-wired | — | — | — | 11,300 | |
| — | 25.00 | — | — | ||
| Supply & fixing of 18 watts LED battern similar to Crompton model No. 1GP161LT8-16 or Bajaj Cat No. BLRB-DB118 with tube light similar to Bajaj BLRB18wCW LED or Crompton LTT8-16, wall mounting tube light complete with integral driver unit complete (detachable tube type) including extension of supply connection by PVC insulated copper cable with replacement warranty period of 5 years | — | — | — | 15,825 | |
| — | 60.00 | — | — | ||
| Supply and laying of 8 SWG GI wire and termination on either end as required at site | — | — | — | 1,440 | |
| — | 30.00 | — | — | ||
| Supply and laying/fixing of GI earth strip of size 25X3 mm and termination as required at site | — | — | — | 4,200 | |
| — | 6.00 | — | — | ||
| Provision of earthing arrangements as per drg No.V/E.G. 362 and connecting with earthing terminals by means of 2 runs of 6 SWG G.I wire | — | — | — | 37,302 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Tenderdocument.pdf
ATTACHMENT
Earthing.pdf
ATTACHMENT
AnnesureIII.pdf
ATTACHMENT
GCCApril-2022withACS_2.pdf GCCApril2022
ATTACHMENT
GCCApril-2022withACS_2.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .