| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.8 LAccepted-AOC 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹33.9 L+₹21,690.20 (0.64%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹37.8 L+₹4.1 L (12.1%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | Rejected-Technical 200 NAVAGAM NAVAGAM TA SAYLA SURENDRA NAGAR GUJARAT 363430 | SURENDRANAGAR | GUJARAT | 363430 | - | Rejected-Technical Contractor is not enlisted in catergory b (ii) hence Rejected |
Tender Value
₹35 L
EMD Value
₹70,000
Closing Date
1 Feb 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Chiloda
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
REPAIR AND MAINTENANCE OF HT ELECTRIC SUPPLY AND ALLIED WORKS AT VSN GANDHINAGAR
2022_MES_571513_1
82137/CHL/E
Open Tender
Electrical and Maintenance Works
Item Rate
335 days
Gandhinagar
As per tender documents
7 documents required · 7 mandatory
₹500
Yes
GE (AF) Chiloda
₹70,000
Yes
20 Feb 2023
27 Dec 2022
7 Feb 2023
27 Dec 2022
1 Feb 2023
18 Jan 2023
28 Dec 2022 - 10 Jan 2023
Amount
Dismantling old unserviceable bending/broken PCC, RCC & steel tubular pole of any size with necessary disconnection of electric wire, demolition of concrete foundation including excavation and earth work as required and removing the same from site complete all specified and directed.
Taking down / out underground cable of aluminium conductor up to 300sqmm of any core after disconnecting from sheet metal encloser / panel board or from OH line from trenches including taking out brick/PCC cable cover, protection pipe etc complete Note:-Excavation, earthwork, will be measured and paid separately under respective items of this schedule.
Taking down / out underground cable of aluminium conductor of 95 to 300 Sqmm of any core after disconnecting from sheet metal encloser / panel board or from OH line from trenches including taking out brick/PCC cable cover, protection pipe etc complete Note:-Excavation/ earthwork will be measured and paid separately under respective items of this schedule.
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as directed.
M&L Dry sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
Removal of excavated material at a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point in soft / loose soil complete all as directed.
Supply and spreading of aggregate of size 40 mm to 80 mm graded at electric supply sub stations including MAP Sub Stations complete all as specified and directed
M&L PCC 1:3:6 Type C-2 (using 40mm graded stone aggregate) as in foundation of pole, stays etc. complete.
M&L PCC 1:2:4 Type B-1 with 20 mm graded aggregate for coping of pole complete all as directed.
Supply and laying Burnt brick old size sub class 'B' laid in trenches a butting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified .
Laying only un-reinforced pre cast flat concrete cable protection cover retrieved from excavation, laid in trenches as cable protection complete
Supplying & Laying un-reinforced pre cast flat concrete cable protection cover of class HV, type I, size 450mm x 180mm x 40mm, factory made, complete as in repairs all as specified
Laying only bricks (old size) retrieved from excavation, laid in trenches as cable protection complete
M&L 40 mm bore GI tubing light grade including all fittings as in protection of cable complete all as specified
M&L 50 mm bore GI tubing light grade including all fittings as in protection of cable complete all as specified
M&L 80 mm bore GI tubing light grade including all fittings as in protection of cable complete all as specified
Supply and laying Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 35sqmm 3.5 core complete all as specified. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sqmm 3.5 core complete all as specified. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 120 sqmm 3 core complete all as specified. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm3 core complete all as specified. Note:- Excavation / earth work will be measured and paid separately.
Supply and laying Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 300 sq mm3 core complete all as specified. Note:- Excavation / earth work will be measured and paid separately.
Re laying of serviciable HT/LT XLPE under ground cable (4x10sqmm to 3.5x300sqmm) 1100 volt grade obtained from taking down complete all as specified. Note:- Excavation / earth work will be measured and paid separately.
Labour only for boring under road/drain by manual method for inserting the light grade pipe GI tubing up to 80 mm dia cable protection all as specified and directed by Engineer In Charge.
S&F Cable route Indicator made out of 150 mm round disc of cast iron duly written with HT/11 KV cable properly fixed with nut bolts to angle iron 40X40X5 mm length 60 cms properly grouted in ground at a depth 25 cms with PCC 1:2:4 type B1 using 20 mm graded stone aggregate Size 10X10X10 cm underground, including necessary excavation earthwork complete. Angle iron shall be painted with two coats of synthetic enamelled paint over a coat of red oxide primer complete as in repairs all as specified and directed.
M&L Rectification of defect in HT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 sqmm 3 core, complete all as specified and as directed by Engineer-in-Charge. Note: (a) The fault locatting equipment will be brought at site within 02 hours of Instruction received from Engineer-in-charge otherwise penalty shall be imposed at the rate of Rs 2000/- per hour with the approval of GE
M&L Rectification of defect in LT 11 KV cable laid in trenches by locating fault with the help of electronic fault locator machine comprising of surge generator pulse ECHP fault location with high frequency distance calculator etc. including excavation in any type of soil strata exposing the cable fault removal of deteriorated position of cable treating of cable and keeping the same ready for jointing work for cables of size upto 300 sqmm 3 core, complete all as specified and as directed by Engineer-in-Charge. Note: (a) The fault locatting equipment will be brought at site within 02 hours of Instruction received from Engineer-in-charge otherwise penalty shall be imposed at the rate of Rs 2000/- per hour with the approval of GE
S&F Cable jointing kit for 11000 volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm 3 core as in repairs complete all as specified.
S&F Cable jointing kit for 11000 volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 Sqmm to 185 Sqmm 3 core as in repairs complete all as specified..
S&F Cable jointing kit for 11000 volts grade cable for straight through joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 Sqmm to 400 Sqmm 3 core as in repairs complete all as specified
M & L Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skulls and bones in single red colour and fixed with MS Clamps, bolts and nuts of approved of size for LT 20 X 15 cm as in repairs complete all as specified
S&F Cable jointing kit for 11000 volts grade cable for Indoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm 3 core complete as in repairs all as specified.
S&F Cable jointing kit for 11000 volts grade cable for Outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 sqmm 3 core as in repairs all as specified.
S&F Cable jointing kit for 11000 volts grade cable for Outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 240 sqmm to 300 sqmm 3 core as in repairs all as specified.
S&F Cable jointing kit for 11000 volts grade cable for Outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 120 sqmm to 185 sqmm 3 core as in repairs all as specified.
S&F Cable jointing kit for 11000 volts grade cable for indoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable up to 300 sqmm 3 core as in repairs all as specified.
S&F Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 185 to 300 Sqmm 3.5 core as in repairs all as specified.
S&F Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size 70 to 150 Sqmm 3.5 core as in repairs all as specified.
S&F Cable jointing kit heat shrink type for 1100 volts grade cable for straight through joints with jointing material and accessories suitable for LT armoured aluminium conductor cable of size up to 50 Sqmm 3.5 core as in repairs all as specified
M&L Preparation of old painted surface of four pole structure of steel tubular pole (11 meter long above coping) and applying one coat of aluminium paint, making of strip of 20 cm width (sky blue and white in alternate band) upto 1400 mm height with one synthetic enamel paint, rewriting pole No by painter/digital stickers with making of pole No with enamel paint, and painting the existing MS clamp with one coat of aluminium paint complete all as specified and directed
S & F MCCB FP 63 amp adjustable type 16 KA. Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCCB FP 100 amp adjustable type 25 KA. Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCCB FP 125 amp adjustable type 25 KA. Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCCB FP 160 amp adjustable type 36 KA. Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCCB FP 200 amp adjustable type 36 KA . Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCCB FP 250 amp adjustable type 36 KA . Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCCB FP 400 amp adjustable type 36 KA . Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCCB FP 630 amp adjustable type 50 KA . Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCB TPN 63A, C Curve Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F MCB TP 40 A,C curve Including terminal connections complete with required size of aluminium lugs etc as in repairs complete all as specified
S & F ACB 4 Pole, 415 V, with Thermal Magnetic Release (Manual Fixed type) of capacity 800 Amps complete as in repairs all as specified and directed.
M&L Chemical earthing complete with copper plate electrode (98 percent conductivity when annealed) 900 mm x 600 mm x 5 mm thick buried directly in ground ( Earth pit not less than 2.25 Meters deep below normal ground level and 1.3 mtr wide) with top edge of the plate not less than 1.5 mtr below ground level earth plate connected to copper strip (98 percent conductivity when annealed) 32 x 6mm (drawn in and including earth lead protection pipe light grade GI of size 50 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in Plate No 2 of SSR Part I connected to earthing lead , filling with Charcoal 400 KG , dust and common salt 325 KG and Magnesium sulphate 100 KG, necessary excavation and earth work in any type of soil, perforated watering pipe , funnel with wire mesh, earth lead protection pipe light grade PCC Chamber 1: 3 :6 type C1 ( for even finish on both the faces ) and RCC cover 1:2:4 type B1, 550 x 550 x 50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 nos of handles of 10 mm dia Steel rod 500 mm Long all as specified and directed and testing on completion and connected to equipment with lugs and screw nuts etc complete all as specified and as directed. Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead . Any variation in length shall be adjusted through deviation order (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost
M & L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtr below normal ground level, connecting to the Galvanised iron earth lead 32 x 6 mm size by means of bolts, nuts check nuts and washers of galvanised iron and 32 x 6 mm dearth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.3 of SSR1Part I and connecting to earth test point all as specified or indicated including testing on completion
S&F Aluminium strip of existing size 32 x 6 mm with saddles and fixing screws etc for earthing connection to bus bar trunking system of existing LT Panels complete as in repairs all as specified at MAP power stations
S&F Copper strip of existing size 32 x 6 mm with saddles and fixing screws etc for earthing connection to bus bar trunking system of existing LT Panels complete as in repairs all as specified
S&F Steel tubular, swaged poles with cast iron base plate of size 300mm x 300mm x 6mm, finial taper plug, bolts, nuts & screws for type-410 SP-31 (9.0 mtrs long) including painting with two coats of aluminium paint over one coat of red oxide primer on all exposed surfaces and tarring with black bituminous paints to embedded portion in PCC and providing of 3 Nos of 30cm wide circular bands with black & yellow paint staring from plinth level at a gap of 30 cm in between 2 bands and numbering of poles, in yellow paint over black painted back ground at a height of 2m from bottom of pole with 3 cm large bold letters 2” (inch) wide complete all as specified and directed. Note : Excavation earthwork, PCC in foundation and coping shall be measured and paid separately under relevant item
Comprehensive Maintenance / Servicing of existing VCB, 3 phase, 11 KV, 630 / 400 Amps by authorised dealer. The scope of work includes : (a)Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr in Charge. The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/resetting required. (b) Checking of heater mechanism, IR value,14 KV hypo test at site, replacement of locking arrangement & testing for smooth functioning at rated voltage. (c) Making all indicator bulbs and push buttons functional at no additional cost (d) Making all electrical connections to voltmeter and ammeter good and ensure the proper functioning of ammeters and voltmeters with proper calibration/adjustment of voltage and current of outgoing VCB,s with main Incomer VCB Note: (1) The contractor should ensure the proper functioning of VCB's and should approach with authorised dealer for carrying of servicing of breaker periodically & when fault /breakdown occurs. (2) Contractor shall produce all Purchase Vouchers and test certificate before submitting RAR. (3) The contractor shall be responsible for serviceability of VCB for the entire contract period (4) Unserviceable Spare Parts will be paid and measured separately under respective items of schedule. (5) Contractor shall arrange the transport VCB trolley to manufacturer workshop and refix after repair as directed by Engr-in-Charge. Cost for transportation deem to be included in this item. (6) Contractor shall arrange required parts and make serviciabililty as per direction of JE/ Engr in Charge within 48 hours otherwise penalty shall be imposed at the rate of Rs 5000/- per hour with the approval of GE
(a) Supply only 1 Amp PT fuse (set of three fuses)
(b) Supply only tripping coil and close coil for smooth / healthy functioning of HT VCB complete all as specified and directed by Engr in charge.
(c) Supply only gear assembly for healthy functioning of HT VCB complete all as specified and directed by Engr in charge.
(d) Supply only raking rack out assembly for healthy functioning of HT VCB complete all as specified and directed by Engr in charge.
(e) Supply only Potential transformer for VCB's 11000/110 volt, 3 phase, as CG, ABB & C&S including making all electric connections good and making the meters functioning well all as specified and directed by Engr- In-Charge
(f) Repair and servicing of KWH meters for VCB's including making all electric connections good and making the meters functioning well all as specified and directed by Engr- In-Charge
(g) Supply only battery backup for VCB as required. Make: CG/ABB/C&S
(h) Supply only Motor charge spring mechanism with all necessary coils complete
(j) Supply only Master trip relay 11 KV suitable for VCB
(k) Supply only Thermostat 52 degree to 90 degree suitable for VCB
(l) Supply only Annuceator MLD-02 with hooter with short circuiting rating 1.8 KA, 400Amp, 250MVA for VCB
(m) Supply only HRC fuze 6 to 10 amp with maximum short circuiting rating 1.8 KA, 400Amp, 250MVA for VCB
(n) Supply only Self power relay for VCB
(o) Supply only HT insulator 11 KV for VCB
(p) Supply only CT epoxy type of raing upto 400/200/5 amp SET OF THREE complete for VCB
M & L Opening the HT 11 KV, Bus bar chamber of HT panel/VCB , cleaning the HT bus bar , inspect the nuts, bolts, bus bar insulator and fighting/replace with new one if required and heating up for removal of moisture , record its IR value with the help of 5 KV megger and applying thick coating of Z931 strippex B and Z955 Strippex (SL) of stanvac product for preventing from flush over and fire hazard , including replacement of 3/2 mm thick gasket, closing of all holes and charging the same complete all as directed by Engineer -in- Charge .
Disconnecting the existing Unserviceable over current and earth fault relay from the VCB Panel and Supply and fixing of new digital microprocessor Base 3 over current +1 earth fault relay complete all as specified and directed by Engineer -in- Charge
Comprehensive Maintenance / Servicing of existing RMU's SF 6, 3 phase, 11 KV, 630 / 400 Amps by authorised dealer of the Manufacturer. The scope of work includes: (a) Calibration of metering system, checking, setting, adjustment of over current relay, earth fault and tripping relay complete all as specified and directed by Engr in Charge. The contractor should immediately approach mechanic of authorised dealer as soon as fault occurs/resetting required. (b) Checking of all incoming and outgoing HT Terminals for any looseness and ensuring the proper tightness for all terminals. (c) Checking the nominal operating gas presssure as per manufactures standard of RMU and testing for any leakage of insulation gas and rectify the same if found (d) Operating gas pressure should be suitable to satisfy the rated dielectric strength (e) Testing for CT's, PT's, Relays , Breakers and cable glands. (f) Anti oxide greasing should be done at all connections of cable and bus bars Note: (1) The contractor should ensure the proper functioning of RMU's and should approach with authorised dealer dealer of the Manufacturer for carrying of servicing of breaker periodically & when fault /breakdown occurs. (2) Contractor shall produce all Purchase Vouchers and test certificate before submitting the RAR. (3) The contractor shall be responsible for serviceability of RMU's for the entire contract period by authorised dealer. (4) Unserviceable Spare Parts will be paid and measured as in repairs separately under respective items of Schedule. (6) Contractor shall arrange required parts and make serviciabililty as per direction of JE/ Engr in Charge within 48 hours otherwise penalty shall be imposed at the rate of Rs 5000/- per hour with the approval of GE
(a) Supply only epoxy CT up to 200/100/5 Amp 3 set all as specified directed
(b) Supply only over current relay for RMU 14 S as per sample all as specified and directed
(c) Supply only indicating lamp for RMU as per sample all as specified and directed.
(d) Supply only Hydraulic mechanism for door of RMU as per sample all as specified and directed.
(e) Supply only Self power relay for RMU as per sample all as specified and directed.
Compressive repair and maintenance of Air Circuit Breaker up to capacity 2000 Amps by cleaning of interphase barriers, Draw out contacts on the circuit breaker and stationary contacts in the cubicle should be cleaned and inspected for overheating, alignment and broken and weak springs. Coat contact surfaces with contact lubricant to ease mating, ensure lubrication is done according to the manufacturer specification, protective relays and circuit breaker trip devices should be inspected and tested according to manufacturer specifications including testing complete.
Servicing of transformer 1250/1000/630/500 /400/315/200/100 KVA carrying out insulation resistant test(HT-LT,HT-E & LT-E), BDV of Oil (top & bottom sample), Filtration & topping up of oil, test, quarterly resistance check of earth pits, arresting of leakage by proper tightening of terminals& joints, replacement of loose or burnt out gasket nut & bolt, & proper sealing of valves etc as directed by Engineer-in-Charge. Note:- (i)The cost of oil filtration & new oil will be measured & paid separately. (i) The contractor should produce all testing certificates immediately after testing, Testing should be carried out by authorized rep of OEM only
Dehydration / filtration of transformer oil of transformers of various capacities installed in different locations under GE ( AF ) Chiloda, by recirculation of existing transformer oil with trolley mounted filtration plant till dielectric strength is up to 40 KV to 50 KV. Note- Quoted rates shall deem to include for following :- (i) Oil shall be tested after filtration and test result will be recorded before & after filtration of oil. (ii) Contractor should make his own arrangement for oil filtration including transportation complete.
Supply only transformer oil for topping during and after filtration as approved by GE
S&F HT terminal with bush ( brass spindle with ceramic bushing) of existing size for transfomers upto 1250 KVA capacity to arrest leakage by opening top cover and refing the same with replacement of worn out gasket complete as in repairs all as specified
S&F LT terminal with bush ( brass spindle with ceramic bushing) of existing size for transformers upto 1250 KVA capacity to arrest leakage by opening top cover and reefing the same with replacement of worn out gasket complete as in repairs all as specified
S&F Synthetic rubberized cork sheet /gasket of 6mm thick, fixing top cover and HT / LT side bushes suitable for 63-200KVA transformer complete as in repairs all as specified
S&F Synthetic rubberized cork sheet/gasket of 6mm thick, fixing top cover and HT / LT side bushes suitable for 250-630 KVA transformer complete as in repairs all as specified
S&F Synthetic rubberized cork sheet/gasket of 6mm thick, fixing top cover and HT / LT side bushes suitable for 700-1250 KVA transformer complete as in repairs all as specified
S&F Breather with accessories of transformer as existing including filling of silica jel complete as in repairs all as specified
Disconnecting all incoming and outgoing cables, removing the transformer from the platform / two pole structure / floor and loading it in the vehicle carefully using crane and transporting it to the contractor's workshop, carry out the required repairs and transport the transformer back to the site , install it, reconnect all the incoming and outgoing cables by properly crimping using lugs of suitable size lugs, taping the bushes / bus bars, using insulation tape and testing of capacity up to 1250 KVA including draining out all the transformer oil ,dismantling and inspection of transformer core and winding including taking out burnt out winding/insulation of HV/LT strips/coils complete all as directed by Engr-in-Charge :-
Rewinding of HT coils with super enamelled copper wire / strips DPC / super enamelled matching with existing gauge and insulating material of high class as per manufacture's recommendation with packing / insulation material in each layer of winding, Baking the core assembly with the help of oven duly varnishing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT / LT bushing studs & lead extension(replacing studs if damaged) and closing the tank top cover by fixing nuts, bolts and washers (Top cover gasket will be measured and paid for separately) complete all as specified and as directed by Engineer-in-charge.
Rewinding of LT coils with super enamelled copper strips DPC / super enamelled matching with existing gauge and insulating material of high class as per manufacture's recommendation with packing / insulation material in each layer of winding, Baking the core assembly with the help of oven duly varnishing the coils to improve IR valve and to eliminate moisture and Inserting the core assembly after repair the core and making connection with HT / LT bushing studs & lead extension(replacing studs if damaged) and closing the tank top cover by fixing nuts, bolts and washers (Top cover gasket will be measured and paid for separately) complete all as specified and as directed by Engineer-in-charge.
M&L Tap changer with tapping arrangement 5% and 7.5% on normal tapping complete as in repairs all as specified and as directed by Engineer-in-Charge
M&L Gun metal gate valve with iron wheel head of 25/20 mm dia heavy duty ISI marked complete including providing necessary rubber packing to stop leakage complete as in repairs all as specified and as directed by Engineer-in-charge
M & L Machine spray by alkyd paint painting of transformers of capacity upto 1250KVA by rubbing, scraping of old paints with emery paper, cleaning and preparation of smooth surfaces complete including writing MES/SM No etc. with approved quality paint all as directed by Engr in Charge
M & L Machine spray by alkyd paint painting of LT Distribution Panels and APFC Panels by rubbing, scraping of old paint with emery paper, cleaning and preparation of smooth surfaces complete including writing MES/SM No etc. with approved quality paint, all as directed by Engr in Charge
Repairs and maintenance of APFC panel of capacity 90KVAR to 200KVAR includes replacement of wiring with copper conductor cable with lugs etc calibration of relay, digital meter including testing complete. Note : Unserviceable Spare Part will be paid and measured separately under respective items
S&F Red/Yellow/Blue LED indicating lamp (Set of three lamp), 240 volts, AC complete as in repairs all as specified
S&F Red luminous push button with LED indicating lamp and 1NC Element complete as in repairs all as specified and directed by Engr in Charge.
S&F Green luminous push button with LED indicating lamp and 1NC Element complete as in repairs all as specified and directed by Engr in Charge.
S&F Cylindrical capacitor capcity of 5 KVAR to 50 KVAR ,440 volts 3 phase , 50HZ complete as in repairs all as specified
S&F APFC controller for contactor switching with 1 CT complete as in repairs all as specified
S&F 50 KVAR capacitor duty contactor , 240 volts, AC coil complete as in repairs all as specified and directed by Engr in Charge.
S&F 40 KVAR capacitor duty contactor , 240 volts, AC coil complete as in repairs all as specified and directed by Engr in Charge.
S&F 25 KVAR capacitor duty contactor , 240 volts, AC coil complete as in repairs all as specified and directed by Engr in Charge.
S&F 12.5 KVAR capacitor duty contactor, 240 volts, AC coil complete as in repairs all as specified and directed by Engr in Charge.
S&F Digital voltmeter 0-500 volts of size 96x96mm complete all as specified as in repairs and directed by Engr in Charge.
S&F Digital Ampere meter 0-500 volts of size 96x96mm complete as in repairs all as specified and directed by Engr in Charge.
S&F Motorised mechanism of capacity 400 to 630 Amps with MCCB 630 Amps including wiring and connected items complete as in repairs all as specified and directed by Engr in Charge.
M&L Servicing of Servo controlled voltage stabilizer up to 1250 KVA , 415 Volt including setting of Input and Output voltage complete all as specified Note:- Spares required for replacement if any will be measured as in repairs and paid separately
(a)Supply only Shunt Trip coil of any size
(b) Supply only Cut out PCB,3-phase
(c) Supply only Micro-controller PCB with connector
(d) Supply only Control cabling with glass fuse
(e) Supply only Indication lamp, 22.5 mm dia, R - Y- B
(f) Supply only Push button,12.5 dia,R -Y-B
(g) Supply only Single phase , Synchronise AC motor, 10 KG
(h) Supply only RC network for 10 KG motor
(j) Supply only Sensing Transformer for Digital/analog control
(k) Supply only Aluminium Busbar of any size and any capacity.
(l) Rewinding of Stabiliser buck boost transformer/Variable voltage transformer, single phase. I/P -0-144 VAC,O/P- 0 -85 VAC with super enamelled copper wire / strips DPC / super enamelled matching with existing gauge and insulating material of high class as per manufacture's recommendation with packing / insulation material in each layer of winding,
(m) Supply only Stabiliser carbon Brush for Dimmer
S&F Cage of wire mesh suitable for covering the outdoor transformers for monkey protection with all the four corners and top bottom angle iron framing of size 3.0 x 3.0 x 1.8 m suitable to be mounted on plinth of transformer and wire mesh net wire size 2.0 mm dia and wire mess square gap 20 mm with arrangement of hinged door on one side for opening and closing of the cage for maintenance of transformers with four no ring of size 25 mm dia and thickness 5.0 mm and made 10 mm hole for inserting the stud of size 5 cm long and 10 mm thick with suitable size bolt also welded in the bottom outer side for holding the casing including PCC 1:2:4 of 20 mm aggregate of size with one coat of red oxide primer and one coat blue colour paint complete as in repairs all as specified and directed.
Repairing of LT panel of size 2.0 m x 1.5 m x 0.5 m by welding of door replacement of hinges wherever required and re-arrange the internal fitting/fixture including replacing of nut bolt and locking arrangement , replace of door sheet thickness 3.15mm size, bottom plate including cable gland upto size 150mm cable (1+4) one incoming and four outgoing cables and disconnection of unserviceable internal cables of any size rewiring/reconnection by suitable size of wire/cable including fixing of panel in PCC 1:2:4 type B-2 using 20 mm graded stone aggregate complete including one coat of red oxide primer and one coat smoke gray colour paint all as specified and directed.
S&F Glow sign board of size 1.5 m x 0.9 m x 0.20 m made out of 1.0 mm thick tin sheet all sides except front side aluminium beading "L" shape at all boarder exterior and interior side, front should be acrylic cover 2.0 mm thick of blue colour and written the subject matter as given by the Engr-in-Charge in English capital letters in white colour with twin tube light fitting 1x 20 watt (2 nos) including all electrical connection with surface conduit wiring 1.5 Sqmm ((length not exceeding 8 meter) copper wire with drilling and necessary required arrangement for fixing of board including testing complete as in repairs as all specified and directed.
S&F RCC cable trench covers of size 1000x500x50mm with lifting handle arrangement covering the open trenches at MRS, Sub Stn No.1 and 2 and all other electric supply installations as in repairs all as specified and directed by Engineer -in- Charge.
M & L Painting of shutters, Xmer Gate and plinth of transformer at E/S Sub stations with white paint all as specified and directed by Engineer-in- Charge
M & L Wall painting of safety instructions from electric shock and fire hazards written in white colour in red back ground of size 2000 mm x 1200 mm all as specified and directed
Supply only safety instruction charts from electric shocks and SOP,s for fire fighting all as specified and directed
M & L Writing the numbers on LT/HT Distribution Panels and the names of area being feeded through the panel, capacity of transformers and associated details written in black colour with white background /or plastic radium sticker complete all as specified
M & L Making foundation of LT Distribution panels with rectangular boundary of specified size made of bricks and cement covering the area all around the panel upto 0.5 m distance and the inner area filled with loose filling aggregates of size upto 80 mm, bricks along the boundary should be painted in white and blue colours alternately all as specified and directed by Engr In Charge
S&F PVC insulated copper conductor wire of 3 core 1.5 sqmm from existing syntex box to light fitting complete as in repairs all as specified.
Supply and fix electric shock proof mat, colour blue 25 mm thick 1 mtr width complete all as specified and directed.
Shifting of serviceable transformer- upto 400 KVA from MES store yard / sub-stn (indoor / outdoor) for installation in place of unserviceable transformer and back after replacing with repaired transformer upto 800 KVA complete all as specified and as directed by Engineer-in-charge.
M & L Construction of earthing chamber any type and making of earthing chamber with operable CI cover as per direction electrical plate No 3 of SSR Part -I 2009 complete including demolition of existing chamber all as specified and directed.
Dighard Electricals
Electricals India
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .